Text
ACCELERATED D TRIBUTION DEMONS TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9204170010 DOC.DATE: 92/03/31 NOTARIZED:
NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1,'ochester G
AUTH.NAME AUTHOR AFFILIATION DODGE,R.E.
Rochester Gas 6 Electric Corp.
MECREDY,R.C.
Rochester Gas 6 Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000244 R
'U Monthly operating rept for Mar 1992 for RE Ginna Nuclear Power Plant.W/920415 ltr.
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR g ENCL Q SIZE: S TITLE: Monthly Operating Report (per Tech Specs)
NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
D 05000244
/
RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A INTERNAL: AEOD/DOA
~RR/~ PQ/LPEB10 CREG FIL Ol EXTERNAL: EG&G BRYCE,J.H NSIC COPIES LTTR ENCL 3
3 1
1 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DOEA/OEAB RGN1 NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1'
D D
~ /Jo p'd"pg7g (( ~
R D
NOTE TO ALL"RIDS" RECIPIENTS:
A D
D PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LIFfS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 14 ENCL 14
szzsu j zztzsIZ
/
zzjijjrts irerzuz
~ znzEE zznzzu ROCHESTER GAS AND ELECTRIC CORPORATION ROBERT C MECREDY Vice Preaident Cinna Nudear Producrion 89 EAST AVENUE, ROCHESTER N. K 14649-0001 TELEPHONE AREACODE tie 546-2700 GINNA STATION April 15, 1992 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Subject:
Monthly Report for March, 1992 Operating Status Information R.
E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Sir:
Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of March, 1992.
Very truly yours, Robert C.
Mec edy RCM/deb Attachments cc:
Mr. Thomas T. Martin NRC (1) 9204g700~0 R
0>00024@
I'DR, "ADOCl" 9 0~~1 PDR
l b
b k
V
4>
OPERATING DATA REPORT DOCKET HO.
50.244 DATE A r 5 1992 COMPLETED BY Robert ED Dodge OPERATING STATUS TELEPHONE 315 524-4446 ext. 396 1.
2 ~
3.
4.
5.
6.
7.
8.
Unit Name:
R.E.
GIHNA NUCLEAR POWER PLANT Reporting Period:
March 1992 Licensed Thermal Power (MWt):
1520 Nameplate Rating (Gross MWe):
490 Design Electrical Rating (Net HWe):
470 Maximm Dependable Capacity (Gross MWe):
490 Maximus Dependable Capacity (Het MWe):
470 If Changes Occur in Capacity Ratings (Items Nunber Notes:
The unit operated at approximately 97% power level for the entire report period.
The unit was removed from service on 3-27-92 for the Annual Refueling and maintenance.
3 Through 7) Since Last Report, Give Reasons:
9.
Power Level to Which Restricted, If Any (Het We):
10.
Reasons For Restrictions, If Any:
This Month Yr.-to-Date Cwulative
'11 ~
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
Hours In Report Period Hunber of Hours Reactor Was Critical Reactor Reserve Shutdown Hours Hours Generator On-Line Unit Reserve Shutdown Hours Gross Thermal Energy Generated (MWH)
Gross Electrical Energy Generated (MWH)
Het Electrical Energy Generated (MWH)
Unit Service Factor Unit Availability Factor Unit Capacity Factor (Using MDC Net)
Unit Capacity Factor (Using DER Het)
Unit Forced Outage Rate 744 631.30 625.75 293 653 278 439 84.11K 84.11K 79.63K 79.63K 1.5Iy4 2184 2021.47 1938.75 2 756 352 931 728 883 027 90.83K 90.83K 86.02K 86.02K 4.41K 196 290.45 155 343.43 1 687.55 152 689.13 1687.55 215 970 865 71 261 335 67 635 574 77.95K 77.95K 74.69K 74.69K 6.03/
24.
Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):
Annual Refuelin and Maintenance Outa e:
Startin March 27 1992 Duration: 43 da s 25.
If Shut Down At End Of Report Period, Estimated Date of Startup:
05-07-92 26.
Units In Test Status (Prior to Coemercial Operation):
Forecast Achieved INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATIOH "CUMULATIVE TOTAL COMMENCING JANUARY 1, 1975
"*CUMULATIVE TOTAL COMMEHCIHG HOVEMBER 8,
'1969
0 a.
t
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-244 UNIT R.E.
Ginna Nuclear Power Plant DATE A ril 1992 COMPLETED BY Robert E.
odge TELEPHONE 1
315 524-4446 ext.
396 MONTH March 1992 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 54 17 ~
476 2 ~
110 18.
475 3
~
304 19 ~
474 4 ~
475 20'73 5.
476 21.
475 6.
475 22'76 7
~
476 23.
475 8.
476 24.
475 9.
476 25.
475 10'78 26 ~
476 477 27'38 12'77 28'12 13'78 29.
14
'5.
477 477 30.
31.
16.
476 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
4 1
n F
c l)O(:KlT NO.
~0-244 liNITNAMI:.R.E- (siNNA MUCLEAtt POWER PLANT UNIT SHUTDOWN AND POWER REDUCTIONS DATI'-
2
(:OMPLl:.TI(D BY d e REPORT MONTH 15)- 24-4446 Ext 396 Ho.
Date D
t-0
@I h
oP 0
o X a0 VIaD cc Pl OI ~o a v a~D D IIl C o
C1 Licensee Event Report 0
Em D
M O
DIll C
o O
fJ Cause gI Corrective Action to Prevent Recurrence 92-04 3-27-92 The bnit was shutdown on March.;.27 for the Annual Refueling and Maintenance Outage it remained shutdown at the end of the report period.
1 F: Forced S:
Scheduled ICY. 4/$5 4949 Reason:
A-Equipmeat Failure (Explain)
B4haintenance or Test C-Refueling D-Regulatory Restriction'&perator Trainiag gt License Examinacioa F-Administrative
&Operational Error (Explain)
Hither (Explaia) 3
- Method:
14fanual 2-Manual Scram.
3-Automatic Scram.
4cher (Explain)
Exhibit G - Instructions for Preparation of Daca Encry Sheets for Licensee Event Report (LER) File (NUREG-0161)
Exhibit 1 - Same Source
-0
'I e
NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-244 UNIT R.E.
Ginna Nuclear Power Plant DATE A r'5 992 COMPLETED BY Ro ert E.
Dodg TELEPHONE 1
315 524-4446 ext.
396 MONTH March 1992 The unit returned to service on 3-1-92 and operated at.
approximately 974 Reactor Power. On 3-27-92 the unit was removed from service for the Annual Refueling and maintenance outage.