Monthly Operating Rept for Oct 1991 for Re Ginna Nuclear Power Plant
ML17262A658
Person / Time
Site: Ginna Constellation icon.png
Issue date: 10/31/1991
From: Dodge R, Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9111220277
Download: ML17262A658 (10)


Text

ACCELERATED DJ TRIBUTION DEMONS TION SYSTEM j

REGULATORY XNFORMATION DISTRIBUTION SYSTEM (RIDS)

FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

AUTH.NAME AUTHOR AFFXLIATXON DODGE,R.E.

Rochester Gas

& Electric Corp.

MECREDY,R.C.

Rochester Gas

& Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION DOCKET g

05000244

SUBJECT:

Monthly operati

. for Oct 1991 for RE Ginna Nuclear Power Plant.W 91 115 ltr.

DISTRIBUTION CODE IE24D COPIES RECEIVED:LTR ENCL SIZE:

TXTLE: Monthly Operating Report (per Tech Specs)

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 D

RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A INTERNAL: AEOD/DOA NRR/DL~Q/

B10 PEGp~LE~

1 EXTERNAL WRIER CE 1 J ~ H NSIC COPIES LTTR ENCL 3

3 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DOEA/OEAB RGN1 NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 D

D R

D NOTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LINIS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 14

h

l IIIIIII'WZZ AHO ngrgrz zziuzzz rr rrrrrrr rrrre ROCHESTER GAS AND ELECTRIC CORPORATION ROBERT C MECREDY Vice President Cinna true!ear Production pa r Qe(AA rrte

/

Years stare o

89 EAST AVENUE, ROCHESTER N. K 14649-0001 TELEPNONE ArtEAcceE no 546-2700 GINNA STATION November 15, 1991 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Monthly Report for October, 1991 Operating Status Information R.

E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of October, 1991.

Very truly yours, Robert C. Mecredy RCM/eeh Attachments cc:

Mr. Thomas T. Martin NRC (1) 9i-1-i-220277r 91 i03 i

PDR-,- 'DOCK =05000244

<<R PDR

OPERATING DATA REPORT DOCKET NO.

50.244 DATE Nov r 15 1991 COMPLETED BY Robert E. Dodge OPERATING STATUS TELEPHONE 315 524.4446 ext. 396 2.

3.

4.

5.

6.

7.

8.

Unit Name:

R.E.

GINNA NUCLEAR POWER PLANT Reporting Period:

October 1991 Licensed Thermal Power (MWt):

Nameplate Rating (Gross MWe):

Design Electrical Rating (Net MWe):

Maximm Dependable Capacity (Gross MWe):

Maximua Dependable Capacity (Net MWe):

If Changes Occur in Capacity Ratings (Items Notes:

The unit operated at approximately 97/ reactor power level for the entire report period.

1520 490 470 490 470 Hurber 3 Through 7) Since Last Report, Give Reasons:

9.

Power Level to Which Restricted, If Any (Het MWe):

10.

Reasons For Restrictions, If Any:

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

Hours In Report Period Nunber of Hours Reactor Was Critical Reactor Reserve Shutdown Hours Hours Generator On. Line Unit Reserve Shutdown Hours Gross Thermal Energy Generated (MWH)

Gross Electrical Energy Generated (MWH)

Net Electrical Energy Generated (MWH)

Unit Service Factor Unit Availability Factor Unit Capacity Factor (Using MDC Net)

Unit Capacity Factor (Using DER Net)

Unit Forced Outage Rate This Month 745***

745 745 1

103 223 373 123 354 883 100%

100%

101.35%

101.35%

0%

Yr.-to.Date 7 296 6 127.65 6 073.25 8 694 055 2 929 025 2 781 132 83.24/.

83.24%

81.10%

81.10/

.48/

Cuwiat Ive 192 642.45 151 866.96 1 687.55 149 241.63 8.5 211 044 752 69 591 499 66 050 425 77.63%

77.64/

74.35%

74.35%

6.11%

24.

Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):

Arcual Refuelin and Maintenance Outa e:

Startin March 27 1992 Duration: 40 da s 25.

If Shut Down At Erd Of Report Period, Estimated Date of Startup:

05-10.91 26.

Units In Test Status (Prior to Camercial Operation):

Forecast Achieved INITIALCRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

  • CUMULATIVE TOTAL COMMENCING JANUARY 1, 1975
    • CUMULATIVETOTAL COMMENCING NOVEMBER 8, 1969

"**CHANGE FROM EASTERN DAYLIGHT SAVINGS TIME TO EASTERN STANDARD TIME

t t

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-244 UNIT R.E.

Ginna Nuclear Power Plant DATE November 15 1991 COMPLETED BY Robert E.

Dod TELEPHONE 1

315 524-4446 ext.

396 MONTH October 1991 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 1 ~

470 17

~

475 2 ~

471 18.

475 3

~

471 19

~

475 4

~

471 20.

475 472 21.

476 6 ~

472 22'75 7

~

472 23.

475 8.

473 24.

475 9.

473 25.

475 10'71 472 26

'7'75 476 12.

473 28.

475 13.

473 29'76 14.

474 30.

476 15.

474 31.

476 16'74 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

e

(

r C

DO(:KET NO.

SO-244 UNiTNAMl.. R.E. (slNNA NUCLEAR POWER O'LA)T UNIT SHUTDOWN AND POWER REDUCTIONS D

(:OMPLETED BY bert E. Dodge REPORT MONTH TELEPHONE 315-524-4446

>-396 Ginna station No.

Dote a

.0 e 0

0 o A~

a0Na0 cxl Fl 0

ocvD own a E

0A Licensee Event Report 4

Em 0

0 0

lA 0OIA a

0 0

0 E

0 O

Cause 8a Corrective Action to Prevent Recurrence No unit shutdowns or power reduction this report period.

F: Forced S:

Scheduled REV. 4/8S 4949 Reason:

A-Equipment Failutc (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E&perator Training & License Examination F-Administrative G-Operational Error (Explain)

H-Ocher (Explain)

Method:

1-Manual 2-Manual Scram.

3-Automatic Scram.

4-Other (Explain)

Exhibit G - Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG-0161)

Exhibit 1 - Same Source

C~

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

50-244 UNIT R.E.

Ginna Nuclear Power Plant DATE Novembe 5

1991 COMPLETED BY Robert E.

Dod e TELEPHONE 1

315 524-4446 ext.

396 MONTH October 1991 The unit operated at approximately 974 reactor power level for the entire report period.