ACCELERATED DI UTION DEMONS ATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9108270089 DOC.DATE: ~~~
NOTARIZED: NO FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G
AUTH.NAME AUTHOR AFFILIATION DODGE,R.E.
Rochester Gas
& Electric Corp.
MECREDY,R.C.
Rochester Gas
& Electric Corp.
RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000244 R
SUBJECT:
Monthly operatin for Jul 1991 for R.E.Ginna Nuclear Power Station.
910815 tr.
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR l ENCL J SIZE:
TITLE: Monthly Operating Report (per Tech Specks NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).
D 05000244 /
RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A INTERNAL: AEOD/DOA RRpZlE'PQ/-
EB10 REG FILE 01 EXTERNAL EG &G BRYCEiJ ~ H NSIC COPIES LTTR ENCL 3
3 1
1 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DOEA/OEAB RGN1 NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 D
D R
D NOTE TO ALL"RIDS" RECIPIENTS:
D D
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 14 ENCL 14
t f
r r
t i
t IIIjiiZin ZZZZZZI j' jtisjr rrrrrrrrr ROCHESTER GAS AND ELECTRIC CORPORATION o
89 EAST AVENUE, ROCHESTER N.Y. 14649.0001 ROBERT C MECREDY trice President Cinna Nuclear Production TELEPHONE AREACODE 7tB 546 2700 GINNA STATION August 15, 1991 US Nuclear Reg'ulatory Commission Document Control Desk Washington, DC 20555
Subject:
Monthly Report for July, 1991 Operating Status Information R.
E. Ginna Nuclear Power Plant Docket, No. 50-244
Dear Sir:
Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report. for Ginna Station for the month of July, 1991.
Very truly,yours, Robert C. Mecredy RCM/eeh Attachments cc:
Mr. Thomas T. Martin NRC (1) 9i082700S5'i073i PDR'"
ADOCK 05000244 R
F'DR
OPERATING DATA REPORT DOCKET HO.
50.244 DATE t 15 1991 COMPLETED BY Robert ED Dodge OPERATING STATUS TELEPHONE 315 524-4446 ext. 396 1.
2.
3.
4.
5 ~
6.
7.
8.
Unit Name:
R.E.
GIHNA NUCLEAR POWER PLANT Reporting Period:
Jul 1991 Licensed Thermal Power (MWt):
Nameplate Rating (Gross M'We):
Design Electrical Rating (Het MWe):
Maxinun Dependable Capacity (Gross MWe):
Maximus Dependable Capacity (Net MWe):
If Changes Occur in Capacity Ratings (Items Hotes:
The unit operated at approximately 100/. reactor power level for the entire report period.
1520 490 470 490 470 Hunber 3 Through 7) Since Last Report, Give Reasons:
9.
Power Level to Which Restricted, tf Any (Net MWe):
10.
Reasons For Restrictions, lf Any:
This Month Yr.-to-Date Cumulative 11.
12.
13.
14 ~
15.
16.
17.
18.
19.
20.
21 ~
22.
23
'ours In Report Period Nunber of Hours Reactor
'Was Critical Reactor Reserve Shutdown Hours Hours Generator On-Lire Unit Reserve Shutdown Hours Gross Thermal Energy Generated (MWH)
Gross Electrical Energy Generated (MWH)
Het Electrical Energy Generated (MWH)
Unit Service Factor Unit Availability Factor Unit Capacity Factor (Using MDC Het)
Unit Capacity Factor (Using DER Het)
Unit Forced Outage Rate 744 744 744 1
100 696 367 365 348 830 100K 100/
99.76'/
.76K 5 087 3 918.65 3 887 5 518 826 1 867 459 1 773 288 76.41K 76.41K 74.17/
74.17K 0.17X 190 433.45 149 657.96 1 687.55 147 055.38 8.5 207 869 523 68 529 933 65 042 581 77.38y.
74.08K 74.08/,
6.18K 24.
Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):
25.
If Shut Down At End Of Report Period, Estimated Date of Startup:
05-10-91 26.
Units In Test Status (Prior to Conmercial Operation):
Forecast Achieved INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION
- CUMULATIVETOTAL CCMMEHCIHG JANUARY 1, 1975
I I
t t
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-244 UNIT R.E.
Ginna Nuclear Power Plant DATE Au ust 15 1991 COMPLETED BY Robert E.
Do e
TELEPHONE 1
315 524-4446 ext.
396 MONTH Jul 1991 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 1 ~
473 17.
464 2 ~
477 18.
464 3 ~
479 19.
463 4 ~
480 20.
462 5.
479 21.
460 6.
479 22.
460 7 ~
479 23'59 8.
474 24.
457 9.
469 25'58 10'68 26.
457 466 12.
464 13'68 27
'8.
29.
459 459 463 14.
467 15.
465 30.
31.
475 466 16.
465 INSTRUCT10NS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
C
p.
DO(:Kl'.T NO.
~0 24" UNlq NAMI:. R.E. GINNA NUCLEAR POWER PLANT.
UNIT SHUTDOWN AND POWER REDUCTIONS
(:OMPLI'.'I'I'.D I3Y E. Dodge REPORT MONTH Tl:Ll.PIIONE 315-524-4446 x-396
'inna Station Ho.
Date
.o e4 o
o C4 C0 sn O
tx 4
eo-0 o
E u 0
own c o
Cl l.icensee Event Report 4
Ew o
EA +
c0 LA c
Q E
0 O
Cause L Corrective Action to Prevent Recurrence No unit shutdowns or gower reductions this regort period.
1 F: Forced S:
Scheduled Rtv. 4/8S 4949 Reason:
A-Equipment Failure (Explain)
B4laintenance or Test C-Refueling D-Regulatory Restriction E&perator Training & License Examination F-Administrative G-Operational Error (Explain)
H-Other (Explain) 3 hlethod:
1-Manual 2-Manual Scram.
3-Automatic Scram.
4-Other (Explain)
Exhibit G - Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG-0161)
Exhibit 1 - Same Source
4 PI V
I
NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-244 UNIT R.E.
Ginna Nuclear Power Plant DATE Au ust 199 COMPLETED BY Robert E.
Dodge TELEPHONE 1
315 524-4446 ext.
396 MONTH Jul 199 1 The unit operated at approximately 1004 reactor power level for the entire report period.
E
~
y P
P l~+