ACCESSION i(BR FAC IL: 50-;'244 AUTH.INANE KOBERi RP W.

REC IP. NAME STAHLEI C.

REGULA Y INFORMATION DIBTRIBUTI SYSTEM (BIDS) 8712220166 DQC. DATE: 87/12/15 NOTARIZED:

NO DOCKET 0 Robert Emmet Ginna Nuclear Planti Unit iI Rochester G

05000244 AUTHOR AFFILIATION Rochester Gas 5, Electric Corp.

RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

ProJect Directorate I-1

SUBJECT:

Expresses appreciation For time NRC spent w/members oF util staff on 871210. Believes discussions were helpFul in reaching agreement on steam generator snubber replacement program scheduled to begin in Feb 1988 outage.

DISTRIBUTION CODE:

ADDIO COPIES RECEIVED: LTR I ENCL g SIZE:

TITLE:

OR Submittal:

General Distribution NOTES: License Exp date in accordance with 10CFR2> 2. 109(9/19/72).

05000244 RECIPIENT ID CODE/N*NE PD1-3 L*

BTAHLEiC INTERNAL'RN/DAF/LFNB NRR/DEBT/CEB NRR/DEST/RSB NRR/PNAS/ILRB 01 EXTERNAL:

LPDR NSIC COPIES LTTR ENCL 1

1 "1

1 1

RECIPIENT ID CODE/NANE PDi-3 PD NRR/DEBT/ADS NRR/DEBT/NTB NRR/DQEA/TSB OGC/HDS2 RES/DE/EIB NRC PDR COP IEB LTTR ENCL TOTAL NUNBER OF COP IEB REQUIRED:

LTTR 20 ENCL

,r

,t 1

it

e i

t t

//I///I/////I

/I//I///II

'la t Oafish

/

EE/////ll llllllllllll ZZ.::

ROCHESTER GAS AND ELECTRIC CORPORATION o 89 EAST AVENUE, ROCHESTER, N.Y. 14649-QQQI ROGER Wr KOBER VKEPRCSlDENT ELECTRIC PRODVC7lON December 15, 1987 TCLCPNONC

  • RC~ CODD Tie 546.2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Mr. Carl Stahle PWR Project Directorate No.

1 Washington, D.C.

20555

Subject:

Management Meeting Steam Generator Snubber Replacement R.E.

Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Stahle:

Rochester Gas and Electric appreciates the time that mem-bers of the NRC management spent with members of the RG&E Staff on December 10, 1987.

Thank you for arranging the meetings amid the many other activities requiring your attention.

RG&E believes that, these informal discussions are a valuable means for each of us to develop an understanding of our priorities and objectives.

Of course, the RG&E Staff is available to you at any time.

The discussions held with Messrs.

Boger, Kuo, Hartzman and you were particularly helpful in reaching agreement on the steam generator snubber replacement program scheduled to,begin in the February 1988 outage.

Although our submittal (the latest revision was submitted November 20, 1987) only addresses at-power condi-tions as the limiting conditions for the support design, we axe prepared to discuss less limiting conditions at cold shutdown with you in another meeting.

Although small gaps of less than one half inch may be present in the steam generator upper support system transverse to the remaining snubbers, reactor coolant system integrity is maintained during and following a seismic event at these conditions.

A second area of understanding was developed concerning the location of breaks to be assumed in the analyses supporting the snubber replacement.

RG&E is applying section B.l.c.(2)(b)(ii) of MEB 3-1, issued as part of Standard Review Plan 3.6.2 with Generic Letter 87-11, which revised the criteria for arbitrary intermediate break locations.

The Ginna main steam and feedwater lines have been analyzed and the stresses determined to be such that breaks need. be postulated only at the terminal ends.

aFRrFfWO = P~>> ~74 V~/

PDR

'ADDCK 05000244 8712220166 871215!

P PDR'

Finally, the terminal end breaks have been a part of the licensing basis and the design basis for the Ginna model 44 steam generators.

The revised criteria for pipe break loca-tions has changed the loads controlling the design of the steam generator

supports, however, the break locations controlling the loads on the internals are unchanged.

Thus, for the purposes of the proposed support modification, the internals need not be reanalyzed.

Xf the adequacy of the design of steam generator internals is a concern to the. Staff, it should be addressed as a separate generic issue unrelated to the snubber replacement modification.

RG&E will work to resolve questions concerning steam generator internals if that becomes a generic concern.

Again, we appreciate your efforts to meet with us and discuss high priority issues.

Ver truly yours,

.~Q Roger W. Kober

DEC 10 1987 Distribution: z Docket 50-244 ~

PD I-3 Reading M. Rushbrook RE(NKtlKNXN R. Stahle DOCKET NO(S).

50<<244 Nr. Roger H. Kober, Yice President Electric and Steam Production Rochester Gas 8 Electric Corporation 89 East Avenue Rochester, Hew York 14649

SUBJECT:

R. E. Ginna Nuclear Power Plant The following documents concerning our review of the subject facility are transmitted for your information.

Notice of Receipt of Application, dated Draft/Final Environmental Statement, dated Notice of Availability of Draft/Final Environmental Statement, dated Safety Evaluation Report, or Supplement No.

dated Environmental Assessment and Finding of No Significant Impact, dated Notice of Consideration of Issuance of Facility Operating License or Amendment to Facility Operating

License, dated g] Bi-Weekly Notice; Applications and Amendments to Operating Licenses Involving No ligifi d

C id i,d d~l22 7

f W3 Exemption, dated Construction Permit No.

CPPR-

, Amendment No.

dated Facility Operating License No.,

Amendment No.

dated Order Extending Construction Completion Date, dated Monthly Operating Report for transmitted by letter dated Annual/Semi-Annual Report-transmitted by letter dated

Enclosures:

As stated Office of Nuclear Reactor Regulation cc:

with enclosure See attached Sheet 0FStCSP SURNAME(

DATE/

NRR/..

.3 MRus.h o k 1Z/to/ 7

""'RC FORM 3f8 IIOIBOINRCM 0240 OFFICIAL RECORD COPY

I(

Mr. Roger W. Kober Rochester Gas and Electric Corporation R.

E. Ginna Nuclear Power Plant CC:

Harry H. Voigt, Esquire

LeBoeuf, Lamb, Leiby and MacRae 1333 Nes( Hampshire
Avenue, N.W.

Suite 1100 Washington, D.C.

20036 Ezra Bialik Assistant Attorney General Environmental Protection Bureau New York State Department of Law 2 World Trade Center New York, New York 10047 Resident Inspector R.E. Ginna Plant c/o U.S.

NRC 1503 Lake Road

Ontario, New York 14519 Stanley 8. Klimberg, Esquire General Counsel New York State Energy Office Agency Building 2 Empire State Plaza Albany, New York 12223 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Supervisor of the Town of Ontario 1850 Ridge Road
Ontario, New York 14519 Jay Dunkleberger Division of Policy Analysis 8 Planning New York State Energy Office Agency Building 2 Empire State Plaza
Albany, New York 12223

l I

c

~

r I