ACCESSION NBR F*CIL: 50-244 AUTH. NAME KOBERi R. M.
RECIP. NAME STAHLEz C.
REGULATORY ORMATION DISTRIBUTION SY (RIDS) 8710200339'OC.
DATE: 87/10/14 NQTARIZED:
NO DOCKET 0 Robert Emmet Ginna Nuclear Planti Unit 1
Rochester G
05000244 AUTHOR *FFI LIATION Rochester Gas 5 Electric Corp.
RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Requests NRC concurrence w/application bg 871113 in order to expeditiously pursue design change. Util will assume concurrence 8c proceed as planned iF response not received bg date given.
DISTRIBUTION CODE:
A001D COPIES RECEIVED'TR I
ENCL 0 SIZE:
/
TITLE:
OR Submittal:
General Distribution NOTES: License Exp date in accordance with 10CFR2. 2. 10'P(9/19/72).
05000244 RECIPIENT ID CODE/N*ME PD1-3 LA STAHLEi C COPIES LTTR ENCL REC IP IENT ID CODE/NAME PD1-3 PD COPIES LTTR ENCL INTERNAL: ARM/DAF/LFMB NRR/DEST/CEH NRR/DEST/RSH N
- 8/ILRH REG ILE 01 EXTERNAL:
EGhG HRUSKEi S NRC PDR NRR/DEBT/ADS NRR/DEST/MTB NRR/DQEA/TSB OGC/HDS2 RES/DE/E IB LPDR NSIC TOTAL NUMBER OF CQP IES REQUIRED:
LTTR 21 ENCL
~r e~
f!
///////////I im~zZ aL IO lao III//I///III IIIIIIIII U5NPQ 05 ZE.::
ROCHESTER GAS AND ELECTRfd%MQFQSIOAOlMGAST AVENUE, ROCHESTER, N.K 14649-0001 ROGER W. KOBER VKEPRESIDENT ELECTRIC PRODUCTION October 14, 1987 TELEPHONE AREA CODE TIa 546.2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:
Mr. Carl Stahle PWR Project Directorate No.
1 Washington, D.C.
20555
Subject:
Steam Generator Tube Sleeving R. E. Ginna Nuclear Power Plant Docket No. 50-244
Dear Mr. Stahle:
By letter dated February 7, 1986, the NRC Staff issued an SER approving steam generator tube sleeving using a design by Combustion Engineering.
This SER was based on C-E Report CEN-320-P which addressed sleeve lengths of 27 to 36 inches.
In order to have access for sleeving of tubes closer to the periphery of the steam generator, it is our desire to use a
25 inch sleeve.
This sleeve would be used at those locations inaccessible to a 27 inch sleeve.
Design criteria and analysis to support the shorter sleeve length has been produced as Addendum 1-P to the C-E report referenced above.
The design criteria, installation and inspection techniques are essentially unchanged.
Consistent with previous discussions with the Staff, it is our intention to implement this change in tube sleeve design subject to RGaE's review per 10CFR50.59.
In order for us to expeditiously pursue this design
- change, please provide an indi-cation of your concurrence with this application of 10CFR50.59 by November 13, 1987.
If we do not receive an indication by this
- date, we will assume your concurrence and proceed with the program as planned.
Ve truly yours, Roger W. Kober 500024II'
4 ao"."ma<~
00 C~l A GR T-"0 @Pl Ir I ~
I'
~