ML17261A429

From kanterella
Jump to navigation Jump to search
Forwards Summary Exam Rept for 1987 Steam Generator Eddy Current Insp, Summarizing Observations & Corrective Actions from Insp Performed During Feb 1987 Outage
ML17261A429
Person / Time
Site: Ginna 
Issue date: 03/09/1987
From: Kober R
ROCHESTER GAS & ELECTRIC CORP.
To: Lear G
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML17261A430 List:
References
NUDOCS 8703160081
Download: ML17261A429 (4)


Text

ACCESSION NBR FAC IL:50-244 AUTH. NAME KOBERi R. 4l.

RECIP. NAI'IE LEARi Q. E.

REGULATORY

.ORI'IATIQN DISTRIBUTION 'BY

'I (R IDS) 87031b00$ 1 DOC. DATE: 87/03/09 NOTARIZED:

NQ Robev t Emmet Qinna Nucleav Plant.

Unit i. Rochester G

AUTHOR AFFILIATION Rochestev Gas Zc Electric Cov'p.

RECIPIENT AFFILIATION PIIR Pv object Div ectorate 1

DOCKET 05000244

SUBJECT:

Fortoards "Bummav g Exam Rept for 1987 Steam Generator Eddy Cuv rent Inspi " summarizing obsev vations 0 corrective ac+ions from insp performed during 1987 outage.

DIBTRIBUTION CODE:

AO47D COPIEB RECEIVED: LTR J ENCL g BI ZE:

Z TITLE:

OR Submittal:

Inservice Inspec+ion/Testing NOTES: License Exp date in accov dance with 10CFR2> 2. 109(9/ig/72).

05000244 RECIPIENT ID CODE/NAI'1E PWR-A ADTB PIIR-A PD1 LA DIIANNI,D CQPIEB LTTR ENCL 1

1 1

0 1

1 RECIPIENT ID CODE/MANE PMR-A EB PWR-A PD1 PD 04 COF IES LTTR ENCL 1

1 5

5 INTERNAL ADI'I/LFI'IB NRR/DSRO/EIB QGC/HDB2 EXTERNAL: LPDR NBIC 03 05 0

1 1

0 1

1 1

AEOD/PTB B

NRC PDR 01,.

02 1

1 1

1 1

TOTAL NUBBER OF COPIES REQUIRED:

LTTR 18 ENCL 15

434'

~

fl PP 3 I 4 43 it 33 3,

3 K

3 3

II 3 I 4

,c

4. 3 4

I 7I 4

T g

I SlilIIIIIII IIIIIIIIII AND ZZS(Sigh IIIIIII IIIIIIIII IIIIIIII ROCHESTER GAS AND ELECTRIC CORPORATION o

IA ro OA 89 EAST AVENUE, ROCHESTER, N.Y. 14649-0001 ROGER W. KOBER rIICe RResIDEN7 eLecTRlc pRDDUcrroN March 9

1987 rcLepIIDNe

  • RCA COOK 7le 546-2700 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Hr. George E.

Lear< Chief PWR Project Directorate No.

1 Washington, D.C.

20555

Subject:

1987 Steam Generator Tube Inservice Inspection Special Report R.

E. Ginna Nuclear Power Plant Docket No. 50-244

Dear fir. Lear:

In accordance with Section 6.9.2.4 of the Ginna Station Technical Specifications and Appendix B Paragraphs 5.7.1 and 5.7.2 of the Ginna Station Quality Assurance Hanuali we are submitting the 1987 Steam Generator Eddy Current Examination Summary Report for R.E.

Ginna Nuclear Power Plant.

This report summarizes observations and corrective action resulting from inspections performed during the 1987 outage and identifies the tubes inspected>

the location and extent of each indication and the tubes which have been plugged or sleeved.

Si c relyi op N Roger W. Kober xc:

Dr. Thomas E. Hurley Regional Administrator U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussiai PA 19406 Resident Inspector Ginna Station 30~9 87031b00 5 05000244 PDR AQOC

pDR, I

0 t

f (II J P

IS 4

'I II ~

4 4( /

l I

II 1

IL j 4 Nii,

~

1

l