ML17258B163

From kanterella
Jump to navigation Jump to search
Submits Page Changes to 810601 Safety Evaluation for Environ Qualification of safety-related Equipment.Changes Result from Inconsistencies Between Safety Evaluation & Technical Evaluation Rept
ML17258B163
Person / Time
Site: Ginna Constellation icon.png
Issue date: 06/23/1981
From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Maier J
ROCHESTER GAS & ELECTRIC CORP.
References
LSO5-81-06-081, LSO5-81-6-81, NUDOCS 8107090039
Download: ML17258B163 (7)


Text

o Docket No. 50-244 LS05-81-06-081 Nr. John E. ttaier, Yice President Electri c and Steam Product ion Rochester Gas and Electric Company 89 East Avenue Rochester, New York 14649

Dear t<r. Haier:

D IS tffION:

cket NRC PDR LPDR TERA NSIC ORB g5 RF GLainas DCrutchfield HSmith RSnaider OELD OISE (3)

ACRS (10)

BScharf (10)

GDeegan (4)

RDiggs Gray File Xtra Cy (4)

RSchaffsa~al; KNC SUMECT:

Administrative Changes to the Safety Evaluation on Equipment gualification for R. E. Ginna Plant Reference (a):

NRC letter of June 1,

1981, transmitting the Safety Evaluation for the Environmental gualification of Safety-Related Electrical Equipment This letter transmits page changes to Reference (a).

These changes are the result of our identification of inconsistencies between the Safety Evaluation Report (SER) and the Technical Evaluation Report.

Please replace the effected pages with those attached to this letter-Sincerely, 0>iSina1 RLgnod by DenQXS M. CrutChfield Dennis N. Crutchfield, Chief Operating Reactors Branch 85 Division of Licensing

Enclosures:

As stated above cc w/enclosures:

See attached il

'DR ADQCK 05000244)

PDRL OFFICE P SURNAME/

DATEQ DL,'.0

.9.QL HS

r oooo'

~

~ ~ os

~

~ os os

~

~

oloOoo (o

~ oology

.s. RB..SKI.P, RS aider

\\ ~ ~ os

~ o ~ ~ ~

oge

~ o ~ ooo ~

........Z;...281..

..0.'

5J.C DC el

........(.~S/ISl

~

~ ~ ~ ~ o ~ o ~ o

~ ~ ~ ~ o ~ ~ ~ o

~ ~

~

~

~ ~ ~ ~ ~

NRG FORM 3I8 t10-80) NRCM 0240

.OFFlCIAL RECORD COPY USGPO1 1981~5.960

, I

'I 1

~f I II P

1 II I

~ <<,<<) $ l'PQ r

N 4

g 'if I

s

~p.8 AE'CII s

~C<

Wp

+

0*

,~44( is UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 June 23, 1981 Docket No. 50-244 LS05-81-06-081 Mr. John E. Maier, Vice President Electri c and Steam Production

,Rochester Gas and Electric Company 89 East Avenue Rochester, New York 14649

Dear Mr. Maier:

SUBJECT:

Administrative Changes to the Safety Evaluation on Equipment gualification for R. E. Ginna Plant Reference (a):

NRC letter of June 1,

1981, transmitting the Safety Evaluation for the Environmental gualification of Safety-Related Electrical Equipment This letter transmits page changes to Reference (a).

These changes are the result of our identification of inconsistencies between the Safety Evaluation Report (SER) and the Technical Evaluation Report.

Please replace the affected pages with those attached to this letter.

Sincerely,

Enclosures:

As stated above Dennis M. Crutchfse d, Chi Operating Reactors Branch 5

Division of Licensing cc w/enclosures:

See attached

Hr. John E. Maier

~ ~ June 23, 1981 cc w/enclosure:

Harry H. Yoigt, Esquire

LeBoeuf, Lamb, Leiby and MacRae 1333 New Hampshire Avenue, N.

W.

Suite 1100 Washington, D. C.

20036 Mr. Michael Slade 12 Trailwood Circle Rochester, New York 14618 Ezra Bialik Assistant Attorney'General Environmental Protection Bureau New York State Department of Law 2 World Trade Center New York, New York 10047 Jeffrey Cohen New York State Energy Office Swan Street Building Core 1, Second Floor Empire State Plaza

Albany, New York 12223 Director, Technical Development Programs State of New York Energy Office Agency Building 2 Empire State Plaza
Albany, New York 12223 Rochester Public Library 115 South Avenue Rochester, New York 14604 Supervisor of the Town of Ontario 107 Ridge Road West
Ontario, New York 14519 Resident Inspector R. E. Ginna Plant c/o U. S.

NRC 1503 Lake Road

Ontario, New York 14519 Mr. Thomas B. Cochran Natural Resources Defense Council, Inc.

1725 I Street, N.

W.

Suite 600 Washington, D. C.

20006 U. S. Environmental Protection Agency Region II Office ATTN:

EIS COORDINATOR 26 Federal Plaza New York, New York 10007 Herbert Grossman, Esq.,

Chairman Atomic Safety -and Licensing Board U-S. Nuclear Regulatory Coamission Washington, D. C.

20555 Dr. Richard F. Cole Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. Emmeth A. Luebke Atomic Safety and Licensing Board U. S. Nuclear Regulatory Coranission Washington, D. C.

20555

APPENDIX 8 List of Equipment in Section 4.2 Equipment Requiring Additional Information And/Or Corrective Action LEGEND:

DESIGNATION FOR Deficiency NOTE:

(R) Licensee has commi tted to replace equipment R - Radiation T - Temperature QT - Qualification Time RT - Required Time P - Pressure H Humidity CS - Chemical Spray A - Material Aging Evaluation, Replacement

Schedule, Ongoing Equipment Survei llance S

Submergence M Margin I - HELB Evaluation Outside Cont ainment Not Completed QM Qualification Method RPN - Equipment Re locat ion or Rep lacement, Adequate Schedule Not Provided EXN - Exempted Equipment Justification Inadequate SEN Separate Effects Qualification J ustification Inadequate QI - Qualification Information Being Developed RPS Equipment Relocation or Replacement Schedule Provided TER Item No.

Equipment Description Manufacturer Model/

Type Deficiencies (R) 1A (R) 18 15A 158 16A 17A 178 17C (R)19 SOV Operator SOV Operator Cables Cables Cables Cables Cables Cables Level transmitter AS CO AS CO Kerite Kerite Coleman Coleman Rome General Cable Barton LB 8300 86IU LB 8300 864RU Type HT Type HT UNK UNK UNK 289 QI ~QM~A~T~P ~QT QI ~QM~A~T~P ~QT A~R A~R A~R A~R A~R A~R QI~A 8-1

h

APPEiVDIX C

List of Equipment in Section 4.3, Equipment Considered Acceptable or Conditionally Acceptable Legend:

A - Naterials Aging Evaluation TER ITEM NO.

Equipment Description Manufacturer Node l/

Type Defici enci es 13A Electrical Penetrations Crouse-Hinds (R) 18 (R) 23 25 8B 8C 8H 15C 5A 8A 8F 8G Level Transmitters Pressure Transmitter Level Transmitter NOV NOV NOV Cable SOV Operator Damper NOV NOV NOV LINITORQUE Foxboro Foxboro Foxboro LINITORQUE LINITORQUE LIMITORQUE LIMITORQUE Kerite AS CO LIMITORQUE LIMITORQUE LINITORQUE SNB-000 611-G N-ASI 611-G N-DSI 613"DN-MSI SNB-00 SNB-00 SNB-00 SNB-1 Type HT SMB-2 SNB-00 SNB-00