ML17258B132

From kanterella
Jump to navigation Jump to search
Provides Update of Activities Re Containment Purge & Vent Valves.Travel Stops Installed in Containment Purge Valve Actuators Will Limit Valve Opening to Approx 50 Degrees. Structural Integrity Following Closure Verified
ML17258B132
Person / Time
Site: Ginna 
Issue date: 06/16/1981
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
NUDOCS 8106240294
Download: ML17258B132 (5)


Text

REGULATORY ORMATION DISTRIBUTION SY

.M (RIDS)

ACCESSION NBR:8106240290 DOC ~ DATE: 81/06/16 NOTARIZED NO DOCKET' FACIL~:50 244 Robert Emme't Ginna Nuclear-Plant< Unit ii., Rochester G

05000244 AUTH BYNAME AUTHOR AFFILIATION MAIER~J ~ E, Rochester=

Gas 8 Electric Corp'ECIP

~ NAME<,

REC'IPZENT AFF ILIAT'ION CRUTC HF IELD't D ~

Operating Reactors Branch 5

SUBJECT; Provides update of ac valves'ravel stops actuators w)ll,limit St< uctural integri ty DISTRIBUTION CODE:

A03QS COPI TITLE~I Containment Pur ging NOTES:1 copy:SEP

Sect, Ldr.

t:jvities're containment purge L,vent" nstalled in.contajnment purge vylye valve openinp to approx 50 degrees'ollowing closure e verified.

ES RECE'XVED:LTR L E"NCI.'

sIZE:

05000244 RECIPIENT ID CODE/NAME[

ACTION CRUTCHF IELD OLl 05 INTERNAL'. A/D CORE'8 CS EFF TR SYS BR08 ILE 06'R ASSESS BR 10

REEYESgE, 10 SHUMgD ~

15'XTERNAL':

ACRS NSIC COPIES LTTR ENCL>

2 1

1 16 1

1 1

RECIPIENT'D CODE/NAME LPDR 03 CONT SYS BR 12'QUIP QUAL BROS NRC PDR 02'S BR11 REG-FIL 01 COPIES LTTR ENCL"-

1

~

1 1

1 1

JUN 26 198~

TOTAL NUMBER OF COPIES REQUIRED!

LTTR ENCL

11

~

II

'l I

1 "h

I P) l\\

f l

1 1

li'F, II s

1

zwrzz iizzznn Lail ONIAalO+,5'

~l/IE",'balll'q~ j,:,.'sypve, ROCHESTER GAS AND ELECTRIC CORPORATION o

89 EAST AVENUE, ROCHESTER, N.Y. 14649 JOHN E.

MAIER VICE PRESIDENT TELCPHONC AREA COOL'IO 546 2700 June 16, 1981 Mr. Dennis M. Crutchfield, Chief Operating. Reactors Branch No.

5 Division of Licensing U. S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Containment Purge and Vent Valves R.

E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Crutchfield:

In a telephone conversation with Dick Snaider of your staff we were asked to provide an update of our activities regarding containment purge and vent valves.

The following interim actions have been taken to provide assurance of valve operability:

1.

Containment purging and venting will be limited as described in our May 29, 1980 letter.

2.

3.

Travel stops have been installed in the containment purge valve actuators.

These travel stops limit the valve opening to approximately 50'.

Analyses have been performed to demonstrate that the valves will close under design flow conditions.

Detailed stress analysis has been performed for the containment purge valves to verify structural integrity following closure from 50'pen.

In order to comply with your requirements for mechanical operability; and seismic and environmental qualification, we have initiated a complete valve qualification program.

It is planned to replace the existing valve operators with new ones qualified to current standards; and perform structural analyses of the valves and operator assemblies.

/

'<K)f~ "..

JUN g $ 1981@

~n

+"'Wagw8

$98

Ch h

Ih

'I ROCHESTER GAS AND ELECTRIC RP.

June 16 g 19 81 Mr. Dennis M. Crutchfield SHEET NO.

Selection of new operators and completion of the analyses are being scheduled to allow submittal of a final report to you by December 31, 1981.

Delivery and installation of the operators is scheduled for the Spring 1983 refueling outage.

The purge and vent limitations and travel stops will remain in place until the new operators are installed.

Very truly yours,