Order Modifying License,Implementing Tech Specs Requiring Periodic Surveillance Over Life of Plant & Specifying Limiting Conditions for Operation of Primary Coolant Sys Pressure Isolation Valves
ML17258A997
Person / Time
Site: Ginna 
Issue date: 04/20/1981
From: Eisenhut D
Office of Nuclear Reactor Regulation
To:
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17258A998 List:
References
NUDOCS 8105040094
Download: ML17258A997 (8)


Text

7590-0'1 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of ROCHESTER GAS

& ELECTRIC CORP.

R. E. Ginna Nuclear Power Plant

)

)

)

)

Docket No. 50-244 ORDER FOR MODIFICATION OF LICENSE I

The Rochester Gas and Electric Corporation (the licensee) holds Provisional Operating License No. DPR-18, which authorizes'the licensee to operate the R.

E. Ginna Nuclear Power Plant (the facility) at power levels not in excess of 1520 megawatts (thermal) rated power.

The facility, which is located at the licensee's site in Wayne County, New York is a pressurized water reactor (PWR) used for the cormercial generation of electricity.

The. Reactor Safety Study (RSS),

WASH-1400, identified in a PWR an inter-system loss of coolant accident (LOCA) which is a significant contributor to risk of core melt accidents (Event V).

The design examined in the RSS contained in-series check valves isolating the high pressure PrimaryCoolant System (PCS) from the Low Pressure Injection System (LPIS) piping.

The scenario which leads to the Event V accident, is initiate'd by,the failure of these check valves to function as a pressure isolation barrier.

This causes.

an overpressurization and rupture of the LPIS low pressure piping which results in a LOCA that bypasses containment.

7590-01 In order to better define the Event U concern, all light water reactor licensees were requested by letter dated February 23, 1980, to provide the following in accordance with 10 CFR 50.54(f):

l.

Describe the valve configurations and indicate if an Event V isolation valve configuration exists within the Class I boundary of the high pressure piping connecting PCS piping to low pressure system piping; e-g.,

(1) two check valves in series, or (2) two check valves in series with a motor operated valve (NOV);

2.

If ei ther of the above E vent V configurat ions exi st, indicate whether continuous surveillance or periodic tests are being performed on such valves to ensure integrity.

Also indicate whether valves have been kno'wn, or found, to lack integrity; and

3. If either of the above Event V configurations exist, indicate whether plant procedures should be revised or if plant modifications should be-made to increase reliability'n addition to the above, licensees were asked to perform individual check valve leak testing prior to plant startup after the next scheduled outage.

By letter dated March 14, 1980, the licensee responded to our February letter.

Based upon the review of this response as well as the review of previously docketed information for the facility, I have concluded in con-sonance with the attached Safety Evaluation (Attachment

1) that one or more valve configuration(s) of concern exist at the facility.

The attached Tech-nical Evaluation Report (TER) (Attachment

2) provides, in Section 4.0.,

a tabulation of the subject valves.

7590-01 3

The staff's concern has been exacerbated due not only to the large number of plants which have an Event V configuration(s) but also because of recent unsatisfactory operating experience.

Specifically, two plants have leak tested check valves with unsatisfactory results.

At Davis-Besse, a pressure isolation check valve in the LPIS failed and the ensuing investigation found that valve internals had become disassembled.

At the Sequoyah Nuclear Plant, two Residual Heat Removal

{RHR) injection check 1

valves and one RHR recirculation check valve failed because valves jammed open against valve over-travel limiters.

It is, therefore, apparent that when pressure isolation is provided by two in-series check valves and when failure of one valve in the pair can go undetected for a substantial..length of time, verification of valve integrity is required.

Since these valves are important to safety, they should be tested periodically to ensure low probability of gross failure.

As a result, I have deter~ined that periodic examination of check valves must be undertaken hy the licensee as provided in Section III below to verify that each valve is seated properly and functioning as a pressure isolation device.

Such testing will reduce the overall risk of an inter-system'OCA.

The testing mandated by this Order may be accomplished by direct volumetric leakage measurement or by other equivalent means capable of demonstrating that leakage limits are not exceeded in accord-ance with Section 2.2 of the attached TER.

')

l 7590-01 4

In view of the operating experiences described above and the potential consequences of check valve failure, I have determined that prompt action is necessary.to increase the.level of assurance that multiple pressure isolation barriers are in place and will remain intact.

Therefore, the public health, safety and interest require that this modification of Provisional Operating License No. DPR-18 be immediately effective.

Accordingly, pursuant to Section 161 i of the Atomic Energy Act of 1954, as

amended, and the Coranission's regulations in 10 CFR Parts 2 and 50, IT IS HEREBY ORDERED THAT EFFECTIVE INNEDIATELY, Provisional Operating License No. DPR-18 is modified by the addition of the following requirements:

l.

Implement Technical Specifications (Attachment

3) which require periodic surveillance over the life of the plan and which specify limiting:conditions for operation for PCS pressure is ol at i on 'va 1 ves.
2. If check valves have not been (a) individually tested within 12 months preceding the date of the Order, and (b) found to comply with the leakage rate criteria set. forth in the Technical Specifications described in Attachment 3, the NOV in each line shall be closed within 30 days of the effective date of this Order and quarterly Inservice Inspection (ISI), MOV cycling ceased until the check valve tests have been satisfactorily accomplished.

(Prior to closing the MOV, procedur'es shall be implemented and operators trained to assure that the HOY remains cl'osed.

Once closed, the l/OV shall be tagged closed to further.preclude inadvertent valve opening).

3.

The l10V shall not be closed as indicated in paragraph 2 above unless a

supporting safety evaluatio'n has been prepared.

If the HOY is in an I

emergency core cooling system (ECCS), the safety evaluation shall include a determination as to whether the. requirements of 10 CFR 50.46 and Appendix I

K to 10 CFR Part 50 will continue-to be satisfied with the HOV closed.

If the HOY is not in an

ECCS, the safety evaluation shall include a deter-mination as to whether operation with the l]OV closed presents an unreviewed safety question as defined in 10 CFR 50.59(a)(2).

If the requirements of 10 CFR 50.46 and Appendix K have not been satisfied, or if an unreviewed safety question exists as defined in 10 QFR '50.59, then the facility shall be shut down within 30 days of the date of this Order and remain shutdown until check valves are satisfactorily tested in accordance with the Techni-cal Specifications set forth in Attachment 3.

4.

The records of the check valve tests required by this-Order shall be made available for inspection by the NRC's Office of Inspection and Enforcement.

7590-01 IV The licensee or any other person who has an interest affected by this Order may request a hearing on this Order within 25 days of its publication in the Federal

~Re ister.

A request for heari'ng shall be submitted to the Secretary, U.S. Nuclear Regulatory Coranission, Washington, D.C. 20555.

A copy of the request shall also be sent to the Executive Legal Director at the same

address, and to Harry H. Voigt, Esquire,
LeBoeuf, Lamb, Leiby 8
MacRae, 1333 New Hampshire Avenue, N.

W. Suite 1100, Washington, D. C.

20036, attorney for the licensee.

If a hearing is requested by a person other than the licensee, that person shall describe, in accordance with 10 CFR 2.714(a)(2),

the manne'r in which his or her.interest is affected by this Order.

ANY REQUEST FOR A HEARING SHALL NOT STAY THE IMMEDIATE EFFECTIVENESS OF THIS ORDER.

If a hearing is requested by the licensee or other person who has an interest affected by this Order, the Commission will issue an order designating the time and place of any such hearing.

If a hearing is held, the issues to be considered 'at such a -hearing shall be:

(a) Whether the licensee should be required to individually leak test check valves in accordance with the Technical Specifications set forth in Attachment 3 to this Order.

(b) Whether the actions required by Paragraphs 2 and 3 of Section III of this Order nust be taken if check valves have not been tested within 12 months preceding the date of this Order.

7590-01 7

Operation of the facility on terms consistent with this Order is not stayed by the pendency of any proceedings on this Order.

In the event that a need for further action becomes

apparent, either in the course of proceedings on this Order or any other time, the Director will take appropriate action.

R THE NUCLEAR REGULATORY COMMISSION Effective Date:

April 20, 1981

Bethesda, Ma ry 1 a nd Attachments:

1.

Safety Evaluation Report 2.

Technical Evalua'on Report 3.

Technical Specifications Darrell G.

enhu, Director Division of icensing