594'$9 seep CATALYTIC, INC.

Engineerine Department PLANT. GINNA NUCLEAR POWER PLANT CL)FNT ROCHESTER GAS

& ELECTRIC CORP.

LOCATION.

ONTARIO, NEW YORK CATALYTICCONTRACT NO.

36720 SPECIFICATION NO.

7276-1 00-00-78 SP EC I FICATION for PIPING MATERIALS IIeIerence CONSISTING OF CON,~ TAUCTION Vr%'MIreIARYI'IO'OR OOr!STRUOTION L!I4ITED CO!'~ST ~UC'. IO rl:

AS NOTFD T

T fta 2ND LEVEL REVIE'll COMPLETED FORM bl03 eI r"

P

~I S REV.

EN G R.

DATE DATE REL.ASED FQR ENG+.

Item Number Description Safety Related XX Nonnuclear Safety 0

Approved Approved Approved Prepared By PROJC T MA CR

~ R C

NG INC CR VANITY A55URANCE ENGINEER eP AO C

CINCCR Date Date Date 8d Date 82051 1'0436-: 820507 PDR.'DOCK 05000244

-..PDRI Amendment A proved 2- &to o

Data Lead Eel!neer a-w-&

Oate

~. Eaiieeer er'ae /+r Approved Date

>eIect Esp!neer Approved Date

I c 'y 1

E.

\\

('8010'57451' CATALYTIC, INC.

ENGINEERING DEPARTMENT PIPING MATERIALS SPECIFICATION NO. 37276-1300-00-78 LIST OF REUISIONS

~

~

o I

o I

o I

o I

I

~,

08010'374SP I

PIPING MATERIALS

~

CATALYTIC, INC.

ENGINEERING DEPARTMENT SPECIFICATION NO. 37276-1300-00-78 Page 2

LINE CLASSIFICATION: K3N1 CODE:

ASME Sect. III, Class 1

Stainless Steel Primary Rating 2500 lb.

Pressure and Temperature Limitations:

2485 psig (I 650 F.

MATERIAL SIZE DESCRIPTION Pipe

~ 2" and smaller ASME SA-376,

TP316, Seamless, Schedule 160, plain ends (ANSI B36. 10).

Fittings 2" and smaller ASME SA-182, F316, Socket weld, 6000 lb (ANSI B16.11).

Flanges 2"I and smaller ASME SA-182, 'F316, 2500 lb., R.F.,

Meld neck, bore to Schedule 160 (ANSI B16.5).

Bolting All sizes ASME SA-453, Grade 660 stud bolts threaded full length, with two heavy hex nuts to ASME SA-453, Grade 660.

C Gaskets All sizes Asbestos filled, spiral wound, 304 stainless steel, Flexitallic Type CG or equal.

NOTES 1)

All branch connections shall be full reinforcement fittings (e.g.,

"Sockolet") or tees.

I

~

~

~

II II

~ I II

~

~

~

y

~

~

~

~

sl

~

I

~

I o I I I

~

I

~

a il o

~ ~

~

I ~

~

~ i I

~

~ ~

~

~

~

~

~ I

~

~

~

~

~

ll

~

~

~

~

I

0 ~ 0 I 0'114SP PIPING MATERIALS CATALYTIC, INC.

ENGINEEAINQ OEPARTMENT SPECIFICATION NO. 37276-1300-00-78 Page 4

LINE CLASSIFICATION: K5 CODE:

ANSI B31.1 Stainless Steel Primary Rating 2500 lb.

Pr'essure and Temperature Limitations:

2485 psig (I 650 F.

MATERIAL SIZE DESCRIPTION Pipe Fittings II Flanges Bolting 2" and smaller 2" and smaller 2" and smaller I

All sizes ASTM A-376, TP316,

Seamless, Schedule 160, plain ends (ANSI B36.10).

ASTM A-182, F316, Socket weld, 6000 lb.

(ANSI B16.11).

ASTM A-182, F316, 2500 lb., R.F.,

Weld neck, bore to Schedule 160 (ANSI B16.5).

ASTM A-453, Grade 660 stud bolts threaded full length, with two heavy hex nuts to ASTM A-453, Grade 660.

Gaskets Unions

'I All sizes 2" and smaller Asbestos filled, spiral wound, 304 stainless steel, Flexitallic Type CG or equal.

3000 lb. unions, socket weld, ASTM A-182, F316, metal to metal

seats, unions to comply with wall thickness and other applicable requirements of ANSI B16.11, body and seat to be rated for design conditions of 2500 psig (I 650 F.

NOTES:-

1)

All branch connections shall be full reinforcement fittings (e.g., "Sockolet") or tees.

~

gr I