Reactor Vessel Head Vent System Piping Plan,Elevation & Details at El 250 Ft 6 Inches & Above
ML17256A895
Person / Time
Site: Ginna 
Issue date: 09/05/1980
From:
CATALYTIC, INC. (SUBS. OF AIR PRODUCTS & CHEMICALS
To:
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17256A898 List:
References
CON-37276 A-13651, NUDOCS 8205110430
Download: ML17256A895 (1)


Text

ONOl DESCRIPTIVE NORTH EXIST. ~NEW 23/,~h (REF)

ZLOr4 3'/2

+45 45 45 SV-591 O SV-593 7/NOTE 12~)

l SV-590 r

O SV-592 L ((VOTE /8)

F 4'-0/2r

\\

45

~(REF) 29 r24 14 (REF II 356 I "'I i-8/

35

> 3-6

(

(THIS DWG.)

RE'AC TO/

CONTAIN)v(EAT PLAN@ EL. Z52-6 4 AB)VE SCALE: 3/g 01-0 DE.TA,IL I

51 51 l4-O'C)42F)

~REAC7OR

~ ~

I fS

/4 Dl A DLIFELLL THRU-(SEE NOTE "12B)

RHL/-lOO-~f4-K3NI

~ EL.258-'ll //4 (REF) 3'- 6" VI"

)OI" o~

~()0

~l gl Hi&

('.0 qb'5 g5 2

DWG D-13652 SPECIAL FITTING-(S' NlOTE. 12)

DETAlL z

SCALE FULL 51 51 TYP. 2-PLACES (SEE. NOTE 12 )

R HV-LOL-W+-K4N2 RHV-102-3/74, K4N2 (SEE VOrE WR(2C)

GRIND CONCAVE.

C'&ED NOTE FIOA)

CONTAIN I/LENT KEY PLAN I '.

~OOO~

L(;

IppLp 60 1.

DIMENSIONS NOTED AS "REFERENCE" DIMENSIONS ARE INTENDED TO DEFINE EXISTING PLANT FEATURES AND ARE FOR INFORMATION ONLY.

2.

DIMENSION NOTED AS "APPROXIMATE" MAY BE VARIED TO SUIT.

3.

UNLESS OTHERWISE NOTED, ALL DIMENSIONS (OTHER THAN "REFERENCE" OR "APPROXIMATE") SHALL BE HELD WITHIN THE FOLLOWING LIMITS DIMENSION ALLOWABLE DEVIATION 2'- 0" OR LESS

+- 1" GREATER THAN 2' 0"

+

I/2" PER FOOT 4.

UNLESS OTHERWISE NOTED, HORIZONTAL RUNS OF PIPE SHALL BE KEPT HORIZONTAL TO WITHIN 1/16" PER FOOT OF RUN OR 1/4 OF THE NOMINAL PIPE SIZE WHICHEVER IS LESS.

IF A SLOPE IS SPECIFIED THE SPECIFIED SLOPE SHALL BE CONSIDERED A MINIMUM. THIS NOTE DOES NOT APPLY IF BOTH ENDS OF THE PIPE CONNECT TD EXISTING EQUIPMENT OR PIPE 5.

RISERS SHALL BE KEPT TO WITHIN 1/16" OF THE VERTICAL PER FOOT OF VERTICAL LENGTH.

6.

ALL MATERIALS TO BE IN ACCORDANCE WITH CATALYTIC, INC. SPECIFICATION 37276-1300-00-7(3 7.

ALL FABRICATION AND ERECTION OF PIPING TO BE IN ACCORDANCE WITH CATALYTIC, INC, SPECIFICATION 36720 13OP-76 6.

ALL PIPE CAPS TO BE THREADED 9.

'DENOTES 3" LONG NIPPLE 10.

'"DENOTES 6" LONG NIPPLE 11.

LINE NUMBER LEGEND XXXXX"(XX)L SPECIFICATION SIZE SEQUENTIAL NUMBER (OPTIONAL)

SERVICE DESIGNATION (OPTIONAL)

EXAMPLE G-101-1"-G IN2 12.

SEQL)ENCE OF CONS'TRUcTION FOR DETAIL*2 A,. WELD SPECIAL FITTING'5 DWCF D-13652 TO LINE.

RHV-IOO- /4-KSNI AS SHOWN DRILLPUT I/3 PILOT HOLES TO I/4 DIA DRILL THRU SPECIAL CITT INGS DVVGT P-IB(c)52 )TOP OF LINE RHL/-)OO-V4-K3NI AS SHOWN.

C. WELD LINE>> RHV-LOL-0'44-K4N2 ID RHV-102- /4LK4N2 Ill SOCKET OF SPECIAL FLTT IN GS DWG+ D-1365'2 AS SHOWN.

13 ALL INSTALLED PIPING SHALL l)/LEET I HE. CLEANLINESS REQUIRFN(tNTS OF ANSI-N-45.2.1 CLASS C.

14, MODIFICATIONS SHOWN ARE. SE.ISMIC CATEGORY T, AND REQUIRE. A IOCCR50 APPENDIX B QUALITYASSURANCE PROGRAM.

IS. REFERENCE DWG 5 (CATALYTICINC. DWCD'S)

A PIPE SUPPORT DWG S

C 18651 )C 18652) C IE)653 ) IR C IB654 B-PIPE SPECIAL F)1TING DWG>> D-13652.

16. THE B- /4ANUTS FOR THE 5/j..2500 FLANGE CONNECTION SHOWN SHALL BE EI THE'R A'SMF-SA-184 GRADE E) (OU'7 OF SPEC)

OR ASME SA-453 GRADE. 660(IN SPEC.).

17 ALL FABRICATIONAND E.RECTION OF 91PE. SU99ORTS TO BE. 1N AC C 0 R DANC E.

W ITH CATALYT I C 1 'INC. SP 'ECI FI CAT I CiN 367 2 0- 1300 - 7 7.

IB. ORIENTATION OF OPERA'TORS FOR VA'LVES SV-590) SV-59L) SV-592)

AND SV-5C33 SHALL BE AS SHOWN IN PLAN.

icI. PiPE. SH)LLL BE. HYDR,OSTP(TLC TEST FP iN I-) C.C.o~PFLNC, E.

vvirH c.FITF(LYTIC-I iree 5pac. 3'7276-l300 -DD-BI E

EL. 272 4j/AQ-RHV-103-I -K5 A EL 265-2 SV-593

~DECL. 2C3

1 x3/4-6000 S.W REO.

RHV -

'I 04-1-K5 SV-590+-L.2, / 2

- SV-592

$ E L. 2 &3 - r~ L~,

I IIX

))0.

E.

II 0 Jl S'

/

'YV./

.I g5

.Io IS),q's I'c Oq

.SP~

D C

q0 9o 2

'-o.

EL. 2SZ - /l//q (REF)

PHV-IOI-3/4-K442 II RHL/-LOO ~/~-K3NI-

~EL 221 REACTOR RHV-102-%4-K4N2

$ EL. 2(P I - l O&2

+,

EL,260-I IZ (REF)

/

6", /

/

/

/

FI /gN S/

D(pF P)

/9 Sj(+ (gYL o (F2

)6 O'-O'/Z 2-0>NI

<gb yS

'4DY)'

I8'g2 O< 8 I

PS -276 -+

7 IT IT 7$ 0 e

I'e" LIMITED CONSTRUCT(ON AS NOTED PRELIMINARY NOT FOR COi'ISTRUCTION BIDDING PURPOSES 1982 FOR INF RM CONSTRUCT(

N RELEASED FOR P R C

'>q~

Tl-llS DW(T CONTAINS SEISMIC

. p,pppTUpp CATEGORY I MODIFICAIONS IYRLE:,. CA R D

+2 A5 BUiLT

< I=H. L=CR 2447 5/I'/

DETAIL ISSUED FOR CLIENT RELEASE BATE STAGE NO.

PTS.

S~CTIO~ W-A SCALF:

/DC I'

'T HIS DW<:.)

I I 1,27 G/Nlr/ITIO~

/(. 244 I -I 3 SC<LF: NONE IUIOVE D UNIONS. APP R,I ISSUED FOR CLIE.NT'ELEASE CLIENT CDA/INLEN1S INCORPOFTAT! u 3g 77'HIS DRAWING IS THE PROPERTY OF CATALYTIC) LNC THE LNFORWATION CONTAINED HEREON NAY NOT BE USED OR COPIED iN ANY WANNER WITHOUT THE WRITTEN PERHISSION OF THE OWNER.

DATE 2//4/6'D r >8o SCALE AS NOTED DRAwN DY R, PAPAL E.

CNECREO OY H.T IZIR',ALLCE.

CATALYTIC APPROVAL PRINT RECORD FOR RDCLLESTER GA>ifELECT RIC CORPORATION ROBT. E. GINNANUCLEAR UNIT'> ONTARIO ) N.Y.

PREPARED DY CATALYTIC, INC.

ENGINEERING DEPARTMENT, PHILADELPHIA, PENNSYLVANIA REACTOR VESSEL HEAD VENT SYSTE.hh P lPLNG PLAN)ELEVATION> IC DETAILS CP EL. P52L 64 OAEBOVE REV. NO.

CONTRACT'672O w-I 365l LET.

IOC.

IITI5IOD II2.

IOC 2 I T

I I I 0 2

IOC OITIIIOD CATAITTIC AFT'D.

DA'TS SIT FOR R,EVICW 4 COnhLVLE.lv RITI5 ION 6

CATACTTIC AFPD.

DATO AFPD CLIO CLIENT APPROVAL JOB NO. 372770 BWTC TIO. 2447 7

.Rhe Si iO'tSn