ML17256A647

From kanterella
Jump to navigation Jump to search
Forwards Fracture Mechanics Evaluation of High Energy Piping Lines at Re Ginna Nuclear Power Plant, Per SEP Topic III-5.A.Rept Supports Conclusion That leak-before-break Does Apply to Lines.Present Leak Detection Sys Adequate
Date released: 04/30/2018 Download: ML17256A647


Rev 0 to Fracture Mechanics Evaluation of High Energy Piping Lines at Re Ginna Nuclear Power Plant.
ML17256A648
Person / Time
Site: Ginna 
Issue date: 04/08/1983
From: Copeland J, Wu Y
NUTECH ENGINEERS, INC.
To:
References
TASK-03-05.A, TASK-3-5.A, TASK-RR
Download: ML17256A648 (59)
Forwards Fracture Mechanics Evaluation of High Energy Piping Lines at Re Ginna Nuclear Power Plant, Per SEP Topic III-5.A.Rept Supports Conclusion That leak-before-break Does Apply to Lines.Present Leak Detection Sys Adequate
ML17256A646
Person / Time
Site: Ginna 
Issue date: 04/22/1983
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: CRUTCHFIELD D
Office of Nuclear Reactor Regulation
References
TASK-03-05.A, TASK-3-5.A, TASK-RR
Download: ML17256A646 (3)