REGULATORV fNFORMATION DISTRIBUTION SV 'TEM (RIDS)

A ACCESSION NOR:8407260254 DOC ~ DATE: 84/07/20 NOTARIZED:,NO DOCKET 0

FACIL;50-244 Robert Emmet Ginna Nuclear PlantR Unit 1E Rochester G

05000244 AUTH,NAME AUTHOR AFFILIATION KOBERER,ji Rochester Gas L

E RECIP ~ NAtlE RECIPIENT AFFILIATION PAULSON H,A, Operating Reactors Branch 5

SUBJECT:

Forwards revised list of installed safety-related hydraulic snubbers.Rey due to addi piping changes.resulting from seismic upgrade program. Updated listing of mechanica'l snubbers will be submitted when NRC review completed, DISTRIBUTION CODE; ABOIS COPIES RECEIVED:LTRl EIOCL j SIZE:

TITL'E:

OR Submittal:

General Distribution NOTES:NRR/DL/SEP 1cy ~

OLS09/19/69 05000244 RFC IP IENT ID CODE/NAME NRR OR85 BC

'01 INTERNAL: ELD/HDS4 NRR/DL DIR NRR ETB REG E

04 COPIES LTTR ENCL 7

7 1

0 1

1 1

1 1

1 RECIPIENT ID CODE/NAME NRR/DE/MTEB NRR/DL/DRAB NRR/DSI/RAB RGN1 COPIES LTTR ENCL 1

1 1

0 1

1 1

1 EXTERNAL: ACRS NRC PDR NTIS NOTES:

09 02 6

1 1

1 1

LPDR NSIC 03 05 1

1 1

1 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 26 ENCL 24

L 4

N W

tt 4

4 4

I h

L

< ~

IL

/

SI A'IC ROCHESTER GAS AND ELECTRIC CORPORATION o a9 EAST AVENUE, ROCHESTER, N.Y. 14649-gggf ROGER W. KOBER VICE PRESIDENT ELECTIIIC&STEAM ILRDDVCTION TCI.EPHDNE AIICACDDE TI6 546-2700 July 20, 1984 Director of Nuclear Reactor Regulation Attention:

Mr. Walter A. Paulson, Acting Chief Operating Reactors Branch No.

5 U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Proposed Technical Specification Safety Related Snubbers R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Paulson:

The NRC is currently reviewing two proposed Technical Specifications regarding safety related shock suppressors, which were submitted on November 24, 1981 and August 1, 1983.

Both were the result of modifications to plant piping systems, principally our piping seismic upgrade program.

The former submittal proposed that the listing of safety related hydraulic snubbers be included in the Inservice Inspection Program and, in response to an NRC

request, proposed adding mechanical snubbers to the list of snubbers.

The latter further updated the list of hydraulic snubbers in the Technical Specifications.

As a result of additional piping changes resulting from our seismic upgrade

program, the list of hydraulic snubbers must again be revised.

The enclosed list itemizes the currently installed safety related hydraulic snubbers.

As suggested on NRC Generic Letter 84-13, this list is being provided in the format of our 1981 submittal as proposed Inservice Inspection Program page changes.

We request that review of our 1981 submittal use the enclosed up-to-date list of hydraulic snubbers.

Should action be taken on our 1983 submittal first, the enclosed list, in the appropriate format, should be used.

Revisions on the list of safety related snubbers from that currently reflected in our Technical Specifications, and repeating the changes requested in our 1983 submittal, are as follows:

Three hydraulic snubbers have been redesignated, for consistency with the identification system in seismic

upgrade, and nine hydraulic snubbers have been removed from service and replaced with mechanical snubbers.

8407260254 840720 PDR ADOCK'05000244 PDR

4l II',)

JI 4 I l k

,i 9, I

I If

.i

)

IB 4

il

4 ROCHESTER GAS AND ELECTRI CORP.

DATE July 20, 1984 Mr. Walter A. Paulson SHEET NO.

2.

The Technical Specification table is being clarified in that. snubbers AFW-25 to 29, 31, 10 and 13 are on the standby auxiliary feedwater lines to the "A" or "B" feedwater, not on the "A" or "B" auxiliary feedwater.

RGSE previously submitted a proposed Technical Specification to incorporate requirements for mechanical snubbers.

An up-to-date listing of mechanical snubbers can be submitted when NRC review is nearing completion.

Submittal at this time would not be fruitful since mechanical snubbers continue to be added.

e truly yours, u./

Roger W. Kober

Table 8.1 Safet Related H draulic Snubbers Snubber Mark No.

SGA-1 S GA-2 SGA-3 SGA-4 SGA-5 S GA-6 SGA-7 S GA-8 SGB-1 SGB-2 SGB-3 SGB-4 SGB-5 SGB-6 SGB-7 S GB-8 FWU-3 FWU-5 FWU-21 FW-25 AFW-25 AFW-26 Pi in S stem "A" Steam Generator "A" Steam Generator "A" Steam Generator "A" Steam Generator "A" Steam Generator "A" Steam Generator "A" Steam Generator "A" Steam Generator "B" Steam Generator "B" Steam Generator "B" Steam Generator "B" Steam Generator "B" Steam Generator "B" Steam Generator "B" Steam. Generator 11 "B" Steam Generator "A" Feedwater "A" Feedwater "A" Feedwater "A" Feedwater SAFW to "A" Feedwater SAFW to "A" Feedwater Accessible or Inaccessible (A or I)

~A AO J

I s

tl I

(

14 t

V

Table 8.1 (Continued)

Safet Related H draulic Snubbers Snubber Mark No.

AFW-27 AFW-28 AFW-29 AFW-31 AFW-49 FW-83 AFW-10 AFW-13 MS U-8 MS-146(Top)

Accessible or Inaccessible (A or I)

Pi in S stem SAFW to "A" Feedwater SAFW to "A" Feedwater SAFW to "A" Feedwater I

SAFW to "A""Feedwater '1 "A" Aux. Feedwater "B" Feedwater A

if 1

f SAFW to "B" Feedwater SAFW to "B" Feedwater "B" Main Steam "B" Main Steam A

If I

MS-146(Bottom)

"B" Main Steam H-1 H-2 H-3 H-4 H-5 H-6 H-7 H-8 PS-2 PS-4 PS-5 PRZR Relief PRZR Relief PRZR Relief PRZR Relief PRZR Relief PRZR Relief PRZR Relief PRZR Relief PRZR Safety 6 Relief Valve PRZR Safety 6 Relief Valve PRZR Safety 6 Relief Valve

'h I

fl N

lj

~'1 1

~ tl Ib 4

t 4

'A

,h d

Table 8.1 (Continued)

Safet Related H draulic Snubbers Snubber Mark No.

Pi in S stem Accessible or Inaccessible (A or I)

PS-6 PS-8 PS-9 PS-10 PS-11 PRZR Safety 6 Relief Valve I

PRZR S'afety 6 Relief

'N 1 h PRZR Safety 6 Relief

Valve, I,,;,~

tl Valve

" 'I PRZR Safety 6 Relief Valve I

PRZR S afety

& Relief Valve I

E g

tI jul

't P j, g n

N II V

J