ML17254A403

From kanterella
Jump to navigation Jump to search
Proposed Tech Spec Changes,Revising Section 3.11.3 & Deleting Section 3.11.5,re Restriction on Spent Fuel Shipping Cask Handling W/Auxiliary Bldg Crane,To Allow for Storage of Consolidated Fuel
ML17254A403
Person / Time
Site: Ginna 
Issue date: 06/10/1985
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17254A402 List:
References
NUDOCS 8506180021
Download: ML17254A403 (4)


Text

3.11.2 e.

Charcoal adsorbers shall be installed in the ventilation system exhaust from the spent fuel storage pit area and shall be operable.

Radiation levels in the spent fuel storage area shall be monitored continuously.

3.11.3 A load in excess of one fuel assembly and its handling tool shall never be stationed or permitted to pass over

3. 11.4 3.11.5 storage racks containing spent fuel.

0 The spent fuel pool temperature shall be limited to 150 F.

The restriction of 3.11.3 above shall not apply to the movement of cannisters containing consolidated fuel rods if the spent fuel rack beneath the transported cannister contain only spent fuel that has decayed at least 60 days since reactor shutdown.

Basis:

Charcoal adsorbers will reduce significantly the consequences of a refueling accident which considers the clad failure of a single irradiated fuel assembly.

Therefore>

charcoal adsorbers should be employed whenever irradiated fuel is being handled.

This requires that the ventilation system should be operating and drawing air through the adsorbers.

The desired air flow pathi when handling irradiated fueli is from the outside of the building into the operating floor area>

toward the spent fuel storage piti into the area exhaust ducts>

through the adsorbersi and out through the ventilation system exhaust to the facility vent.

Operation of a 850bi8002i 850bi0 PDR ADOCK 05000244 P

3-11-2 PROPOSED

r P

I 1/

I I

li C

4 Nl If 5

'\\

0 t

'N4 C

ii~ i I

ll

The spent fuel pool temperature is limited to 150 F because if the 0

spent fuel pool cooling system is not at that temperature, sufficient time (approximately 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />) is available to provide backup coolingI assuming the maximum anticipated heat load (full core discharge 6 previously stored fuel)> until a temperature of 180 F is reachedI the temperature at which the structural integrity of the pool was analyzed and found acceptable.

The requirement of 3.11.5 insures that should a handling accident occur during the movement of a consolidated fuel cannister (as described in 5.4) the dose at the exclusion area boundary would satisfy the requirements of 10CFR100.

References (1)

FSAR Section 9.3-1 (2)

ANS-5.1 (N 18.6)I October 1973 3.11-4 PROPOSED

, ~ J I

t