ML17251A394

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Util Response to IE Bulletin 85-003, Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings. Info Requested within 30 Days
ML17251A394
Person / Time
Site: Ginna 
Issue date: 12/08/1988
From: Bettenhausen L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
References
IEB-85-003, IEB-85-3, NUDOCS 8812230062
Download: ML17251A394 (4)


Text

Docket No. 50-244 DEC ss vasss Rochester Gas and Electric Corporation ATTN:

Mr. Robert C. Mecredy General Manager.

Nuclear Production 49 East Avenue Rochester, New York 14649 Gentlemen:

Subject:

Request for Additional Information Concerning

Response

to IE Bulletin 85-03, "Motor-Operated Valve Common Mode Fai lures During Plant Transierits Due to Improper Switch Settings" During,the NRC review of your response to IEB 85-03, we have identified the need for additional information.in order to provide a thorough evaluation prior to ap-proval of the program to assure valve operability.

The specific information necessary for the completion of our r'eview is enclosed with this letter.

-Please provide the additional information within 30 days of the date or" this letter.

Your cooperation with us in this matter is appreciated.

Sincerely, R1GI SIGNEO B Lee H. Bettenhausen, Chief Projects Branch No.

1 Division of Reactor Projects

Enclosure:

As Stated cc w/encl:

Harry H. Voigt, Esquire Central Records (4 copies)

Director, Power Division State of New York, Department of Law Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector State of New York OFFICIAL RECORD COPY 8812230062 8-gpq>

PClr'DL1CP 0~0(-.i0244 9

PQQ 126/BAUNACK/12/7/88 0001.0. 0 4 ~ l J2/07/88

~~

<t

](I

Rochester Gas and Electric Corporation 2

PPC 08 1988 bcc w/encl:

Region I Docket Room (with concurrences)

Management Assistant,,

DRMA (w/o encl)

DRP Section Chief C. Stahle, PM, NRR R. Kiessle, NRR Robert J.

Bores, DRSS RI:D Ba

/meo 12/7/

RI: DRP Cow ll RI:DRP n ausen r

OFFICIAL RECORD COPY 126/BAUNACK/12/7/88 - 0002.0.0 12/07/88

RE VEST FOR ADDITIONAL INFORMATION RAI RE:

Review of Res onses to Action Item e of IE Bulletin 85-03 Licensee:

Rochester Gas and Electric Corporation 89 East Avenue Rochester, New York 14649-0001

~Unit a:

Ginna Date of Res onse to RAI Issued 9/9/87:

10/9/87

~Rea ondent:

Roger W. Kober Vice President Electric Production The information provided in your. response listed above to Action Item e of IE Bul-letin 85-03 was found to be deficient in some areas.

Provide the additional in-formation necessary to resolve the following comments and questions:

Revise your response of 10/9/87 to guestion 2 about.water hammer to indicate that factors such as valve closure times, piping lengths, flow conditions, procedures, and experience have been considered.

OFFICIAL RECORD COPY 126/BAUNACK/12/7/88 - 0003.0.0 12/07/88

'1~