UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, O. C. 20555 ROCHESTER GAS AND ELECTRIC CORPORATION DOCKET NO. 50-244 R.

E.

GINNA NUCLEAR POMER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

29 License No.

DPR-18 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Rochester Gas and Electric Corporation (the licensee) dated February 8, 1988 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.c(2) of Facility Operating License No.

DPR-18 is hereby amended to read as follows:

(2)

Technical S ecifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 29, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

8807120447 880b23 PDR ADOCK 05000244 P

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Richard H. l!essman, Director Project Directorate I-3 Division of Reactor Projects I/II

Attachment:

Changes to the Technical Specifications Date of Issuance:

June 23, 1988

ATTACHMENT TO LICENSE AMENDMENT NO.

29 FACILITY OPERATING LICENSE NO.

DPR-18 DOCKET NO. 50-244 Revise Appendix "A" as follows:

Remove Paqes 3.5-2 3.5-4 3.5-20 3.5-21 3.5-22 4.12-2 Insert Pa es 3.5-2*

3 5

2a**

3.5-4*

3.5-4a+*

3.5-4b 3.5-20 3.5-20a**

3.5-21 3.5-22 4.12-2

  • No Change - Repositioned on page
    • Indicates new page

3.5.3.2 3.5.3.3 3.5.4 When required by 3.5.3.1, with the number of operable accident monitoring instrumentation channels less than the Total Number of Channels shown in Table 3.5-3, either restore the inoperable channel(s) to operable status within 7 days, or be in at least hot shutdown within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

When required by 3.5.3.1, with the number of operable accident monitoring instrumentation channels less than the Minimum Channels Operable requirements of Table 3.5-3 either restore the inoperable channel(s) to operable status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in at least ho4 shutdown within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

The radiation accident monitoring instrumentation channels shown in Table 3.5-6 shall be operable, 3.5.5 3.5.5.1 whenever the reactor is at or above hot shutdown.

With one or more radiation monitoring channels inoperable, take the action shown in Table 3.5-6.

Startup may commence or continue consistent with the action statement.

Radioactive Effluent Monitoring Instrumentation The radioactive effluent monitoring instrumentation shown in Table 3.5-5 shall be operable at all times with alarm and/or trip setpoints set to insure that the limits of Specification 3.9.1.1 and 3.9.2.1 are not exceeded.

Alarm and/or trip setpoints shall be established in accordance with calculational methods set forth in the Offsite Dose Calculation Manual.

3;5-2 Amendment No. g, gP, 29

3.5.5.2 If the setpoint for a radioactive effluent monitor alarm and/or trip is found to be higher than required, one of the following three measures shall be taken immediately:

3.5.5.3 the setpoint shall be immediately corrected without declaring the channels inoperable; or immediately suspend the release of effluents monitored by the effected channel; or (iii) declare the channel inoperable.

If the number of channels which are operable is found to be less than required, take the action shown in Table 3. 5-5.

Exert best efforts to return the 3.5.6 3.5.6.1 instruments to OPERABLE status within 31 days and, if unsuccessful, explain in the next Semiannual Radio-active Effluent Release Report why the inoperability was not corrected in a timely manner.

Control Room HVAC Detection Systems During all modes of plant operation, detection systems for chlorine gas, ammonia gas and radioactivity in the control room HVAC intake shall be operable with setpoints to isolate air intake adjusted as follows:

3. 5-2a Amendment No.

29

The radioactive giseou5 effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents.

The alarm and/or trip setpoints for these instruments are calculated in accordance with the ODCM to ensure that alarm and/or trip will occur prior to exceeding the limits of 10 CFR Part 20.

This instrumentation also includes provisions for monitoring the concentra-tions of potentially explosive gas mixtures in the waste gas holdup system.

The operability and use of this instrumentation is consistent with the require-ments of General Design Criterion 64 of Appendix A to 10 CFR Part 50.

Control Room HVAC detection systems are designed to prevent the intake of chlorine, ammonia

'and radiation at concentrations which may prevent plant operators from performing their required functions.

Concentra-tions which initiate isolation of the control room HVAC system have been established using the guidance of several established references (2-4).

The chlorine isolation setpoint is 1/3 of the toxicity limit of reference 2 but slightly greater than the short term exposure limit of reference 4.

The ammonia setpoint is established at approximately 1/3 of the toxicity limit for anhydrous ammonia in reference 2

and equal to the short term exposure limit of reference 4.

The -setpoints for radioactivity correspond to the 3.5-4 Amendment No. P, gP, 29

maximum permissible concentrations of reference 3 for Cs-137, I-131 and Kr-85.

The mini-purge system is connected to the plant vent.

10 CFR Part 100 type releases via mini-purge are limited by an isolation signal generated from SI.

10 CFR Part 20 releases from mini-purge are considered to be similar to other plant ventilation releases and are monitored by R-lOB, R-13, and R-14.

R-14A may be a

substitute for R-10B.

Automatic isolation of mini-purge for 10 CFR Part 20 type releases is considered unnecessar due to the low flow associated with mini-purge and ~

continuous monitoring.

However, the automatic isolation provisions using Rll or R12 provide additional margin for 10 CFR Part 20 type releases.

Therefore, R-11 or R-12 is required to sample containment during mini-purge operation.

To ensure the containment sample monitored by R-11 or R-12 is representative of the containment atmosphere, at least one recirculation fan is required to be in operation during mini-purge operation.

Should R-ll and/or R-12 become inoperable, a

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> limit is chosen to be consistent with the generally accepted time for prompt action.

3.5-4a Amendment No.

29

References 1)

Updated FSAR Section 7.2.

2)

USNRC Regulatory Guide 1.78, June

1974, Assump-tions for Evaluating the Habitability of a Nuclear Power Plant Control Room During a Postulated Hazardous Chemical Release.

3) 10 CFR 20 Appendix B, Table I.

4)

Threshold Iimit Values for Chemical Substances and Physical Agents in the Work Environment, 1982.

Published by American Conference of Governmental Industrial Hygienists.

3.5-4b Amendment No.

29

2.

TABLE 3.5-5 Radioactive Effluent Monitorin Instrumentation Minimum Channels

~Oerahle Cross Activity Monitors (Liquid) a.

Liquid Radwaste (R-18) b.

Steam Generator Blowdown (R-19) c.

Turbine Building Floor Drains (R-21) d.

High Conductivity Waste (R-22) e.

Containment Fan Coolers (R-16) f.

Spent Fuel Pool Heat Exchanger (R-20) 1 Plant Ventilation a.

Without Mini-Purge Action 2.

3.

Noble Gas Activity (R-14.)

(Providing Alarm and Isolation of Gas Decay Tanks)

Particulate Sampler (R-13)

Iodine Sampler (R-10B or R-14A) b.

With Mini-Purge l.

2.3.

4 ~

Noble Gas Activity (R-14)

Particulate Sampler (R-13)

Iodine Sampler (R-10B or R-14A)

Noble Gas Activity (R-12) or Particulate Sampler (R-11) 1 1

1 1++

5 5

8 3.

Shutdown Purge a.

Noble Gas Activity (R-12) b.

Particulate Sampler (R-11) 3.5-20 Amendment Ho, gg, 29

. Minimum Channels O~erable Action c.

Iodine Sampler (R-10A or R-12A)***

4.

Air Ejector Monitor (R-15 or R-15A)***

5.

Waste Gas System Oxygen Monitor Not, required when Steam Generator Blowdown is being recycled (i.e. not released).

+

Required only during shutdown purges and required to sample the containment stack.

++

Required to sample containment during mini-purge operation

    • Not required during Cold or Refueling Shutdown.
      • See Table 3.5-6 3.5-20a Amendment No.

29

TABLE 3.5-5 Continued Table Notation Action 1-If the number of operable channels is less than required by the Minimum Channels Operable require-ment, effluent releases from the tank may continue for up to 14 days, provided that prior to initiating a release:

1.

At least two independent samples of the tank's contents are analyzed, in accordance with Specification 4.12.1.1.a, and 2.

At least two technically qualified members of the 'Facility Staff independently verify the release rate calculations and discharge line valving; Otherwise, suspend release of radioactive effluents via this pathway.

Action 2 When Steam Generator Blowdown is being released (not recycled) and the number of channels operable is less than required by the Minimum Channels Operable requirements, effluent releases via this pathway may continue provided grab samples are analyzed for gross radioactivity (beta or gamma) at a limit of detection of at most 10-7 uCi/gram:

1.

At least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> when the concentration of the secondary coolant is

> 0.01 uCi/gram dose equivalent I-131.

2.

At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the concentration of the secondary coolant is 5 0.01 uCi/gram dose equivalent I-131.

Action 3 If the number of operable channels is less than required by the Minimum Channels operable requirement, effluent. releases via this pathway may continue provided that at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> grab samples are analyzed for gross radioactivity (beta or gamma) at a limit of detection of at most 10-7 uCi/gm.

Action 4 If the number of operable channels is less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue provided grab samples are taken at least once per 8

hours and these samples are analyzed for isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or R14A is operable and readings are reviewed at least once p6r 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

3.5-21 Amendment No, ~,

29

TABLE 3.5-5 Continued Table Notation Action 5

-Xf the number of operable channels is less than required by the Minimum Channels Operable require-ments, effluent releases via this pathway may continue provided samples are continuously collected as required by Table 4.12-2 Item E with auxiliary sampling equipment.

Action 6 If the number of operable channels is less than required by the Minimum Channels Operable and the Secondary Activity is 5

1 x 10 uCi/gm, effluent releases may continue via this pathway provided grab samples are analyzed for gross radioactivity (beta or gamma) at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

If the secondary activity is greater than 1 x 10 uCi/gm, effluent releases via this pathway may continue for up to 31 days provided grab samples are taken every '8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and analyzed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Action 7

If the channel is inoperable, a sample of the gas from the in service gas decay tank shall be analyzed for oxygen content at least once every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

Action 8 - 'f the number of operable channels is less than required by the Minimum Channels

Operable, or at least one containment fan cooler is not operating, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> terminate the purge.

3.5-22 Amendment No. +, 29

4.12.1.2.a Cumulative dose contributions from liqu'id effluents shall be determined in accordance with the ODCM at.

least once per 31 days.

4.12.2 4.12.2.1 4.12.2.l.a Gaseous Wastes Release Rate The effluent continuous monitors as listed in Table 3.5-6 having provisions for the automatic termination of gas decay tank, shutdown purge or mini-purge

releases, shall be used to limit releases within the values established in Specification 3.9.2.1 when 4.12.2.1.b monitor setpoint values are exceeded.

The dose rate due to radio'active materials, other than noble gases, in gaseous effluents shall be determined in accordance with the methods of the ODCM by obtaining representative samples and performing analyses in accordance with the sampling and analysis

program, specified in Table 4.12-2.

4.12.2.2 Dose (10 CFR Part 50, Appendix I); Gaseous Waste 4.12.2.2.a

4. 12.3 Treatment.

Cumulative dose contributions from gaseous effluents shall be determined in accordance with the ODCM at least once every 31 days.

Waste Gas Decay Tanks The quantity of radioactive material contained in each waste gas decay tank shall be determined to be 4.12-2 A'mendment No.

29