Monthly Operating Rept for May 1988 for Re Ginna Nuclear Power Plant
ML17251A126
Person / Time
Site: Ginna 
Issue date: 05/31/1988
From: Mcnamara A, Snow B
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8806220098
Download: ML17251A126 (9)


Text

ACCEL'ERATED IHSI'BUTION DEMONSTRAfiON SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) g,

)V ACCESSION NBR:8806220098 DOC.DATE 88/05/31 NOTARIZED: NO DOCKET g

FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

05000244 AUTH.NAME AUTHOR AFFILIATION MCNAKQK,A.E.

Rochester Gas

& Electric Corp.

SNOW,B.A.

Rochester Gas

& Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

Monthly operating rept for May 1988 for RE Ginna Nuclear Power Plant.W/880614 ltr.

DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTR Q ENCL J SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 RECIPIENT ID CODE/NAME PD1-3 LA STAHLE,C INTERNAL: AEOD/DOA ARM TECH ADV NRR/DOEA/EAB 11 NUDOCS-ABSTRACT RGN1 EXTERNAL: EG&G WILLIAMS,S NRC PDR COPIES LTTR ENCL 1

0 1

0 1

1 2

2 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD1-3 PD AEOD/DSP/TPAB NRR/DLPQ/PEB 11 N

PB 10 G FILE 01 LPDR NSIC COPIES LTTR ENCL 5

5 1

1 1

1 1

1 1

1 1

1 1

1 j

A 9

g TOTAL NUMBER OF COPIES REQUIRED:

LTTR 21 ENCL 19

OPERATING DATA REPORT DOCKET NO.

DATE June 4

1 88 COMPLETED BY Andrew E. McNamara

~ OPERATING STATUS TELFPHONE 315-524'=4446 x-3

~inta Station

1. Unit Name:

R.E. 6INNA NUCLEAR POWER PLANT 2 ~ Reporting Period:

Ma 1

3. Licensed Thermal Power (MWt):
4. Nameplate Rating (Gross MWc):
5. Design Electrical Rating (Nct MWe):
6. Maximum Dependable Capacity (Gross MWe):
7. Maximum Dependable Capacity (Net MWe):

Notes The reactor power level was maintained at 100K in the report period.

The exceptions are detailed on page 4.

8. IfChanges Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Rcport, Give Reasons:
9. Power Level to Which Restricted, IfAny (Net MWc):
10. Reasons For Restrictions, If Any:

This Month Yr. to-Date Cumulative 2 629.20 2 564.50 0

1 146 066 70.32K

11. Hours In Reporting Period
12. Number of Hours Reactor Was Critical 744
13. Reactor Reserve Shutdown Hours
14. Hours Gcncrator On.Line 744
15. Unit Rcservc Shutdown Hours 0

e

18. Net Flcctrical Energy Generated (MWH) l9. Unit Service Factor 100K
20. Unit AvailabilityFactor aa-66JMr
23. Unit Forced Outage Rate O.OOX

" 8.21K

24. Shutdowns Scheduled Over Next 6 Months (Type, Dare and Duration of Each):

162 287.00 126 647.67 124 242.88 8.5

  • 57 290 186 54 357 350 76.56K 72.70K 6.54K
25. If Shut Down At End Of Rcport.Period, Estimated Date of Startup:
26. Units In Test Status (Prior to Commercial Operation):

INITIALCRITICALITY INITIALELECTRICITY COMMERCIALOPERATION

  • Cummulative Total Commencing January,l, 1975 8806220098 SQQ531 PDR ADOCK 05000244 R

DCD Forecast Achieved

tq JIB

~lt

/

L 4,

"I il f

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-244 UNIT R.E.

Ginna Nuclear Power Plant DATE June 14 1988 COMPLETED BY Andrew E.

McNamara TELEPHONE 1

315 524-4446 Ext.

301 at Ginna MONTH Ma 1988 DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 491 17.

490 2 ~

492 18.

491 3 ~

4 ~

492 490 19.

20 ~

491 491 5.

492 21.

490 6.

7 ~

492 316 22

'3'92 492 8.

489 24'91 9 ~

10.

490 491 25

'6.

489 490 12.

13

'4

~

15'91 491 490 490 490 27

'8

'9.

30.

31.

490 490 491 491 489 16'90 1NSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

50-244 UNIT R.E. Ginna Nuclear Power Plant DATE June 14 1988 COMPLETED BY

-"yln, Andrew E.

cNamara TELEPHONE 1

315 524-4446 EXT. 301 at Ginna MONTH Ma 1988 The reactor power level was maintained at 1004 for the majority of the report period, with the following exceptions:

On May 4 the reactor power level was reduced to 97% to perform a periodic test on the Auxiliary Feedwater System.

The reactor power level was restored to 1004 after the test.

On May 7 the reactor power level was reduced to 46% to isolate the lA2 Condenser and plug nine tubes.

The reactor power level was restored to 1004 by the end of the day.

On May 17 and May 21 the reactor power level was reduced to 974 to perform a periodic test on the Auxiliary Feedwater System; on May 21 to verify the operability of a repaired steam admission check valve.

DOCKI:.I NO.

SO-244 UN11 NAMi:. R.E. GINNA NUCLEAR POWER PLANT UNIT SHUTDOWN AND POWER REDUCTIONS DATI:.

COMPLlilED BY Andrew E.

McNama a REPORT hlONTH MAY 1988 I ELEPllONE

x-301 Ginna Station No.

Date o4 0P 0

ev C0 00 IX 0

E 00 own 0 0

Cl Licensee Event Report ¹ E~

0 Vl 0 l O C0 Ml c00 l7 E

0 O

Cau s e 8c Correcti ve Action to Prevent Recurrence 88-2 5-7-88 S

24.5 HR HTEXCH Load reduction tube leaks in lA2 Condenser; plugged 9 tubes.

1 F: Forced S:

Scheduled REV. 418$

4949 Reason:

A-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E&perator Training & License Examination F-Administrative G-Operational Error (Explain)

H-Other (Explain) hlethod:

1-hlanual 2-Manual Scram.

3-Automatic Scram.

4-Other (Explain)

Exhibit G - Instructions for Preparatton of Data Entry Sheets for Licensee Event Report (LER) File (NUREG-0161)

Exhibit 1 - Same Source

l

~

Et GINNA STATION MAINTENANCE REPORT

SUMMARY

MAY, 1988 During the month of May, routine maintenance and inspections were completed.

Major safety related work included:

a

~

b.

c ~

d.

e.

Repack "B" Charging Pump and rebuild assemblies removed for spares R-14 Rad. Monitor Pump - PM Inspection SPING Monitor Pump PM Inspection Replace

Gaskets, studs, and nuts on RHR valves 624 and 626 Snubber Inspection per M-40 Overhauled CV-3504B

EIIIIIIIIIIZ 'I//I//////

'/////II///

////////

i ///I//I/i/I ROCHESTER GAS AND ELECTRIC CORPORATION o 69 EAST AVENUE, ROCHESTER, N.Y. 14649-0001 TCLCPHONC ARCA COOC TIC 546-2700 GINNA STATION June 14, 1988 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Sub) ect:

Monthly Report for May, 1988 Operating Status Information R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

Pursuant to our Technical Specification 6.9.1, attached herewith is the monthly operating status report for Ginna Station for the month of May, 1988.

Very truly yours, Bruce A. Snow Superintendent Nuclear Production BAS/eeh Attachments cc:

Mr. William T. Russell NRC (1)

j 4

~