Rev 1 Summary Exam Rept for 1990 Steam Generator Eddy Current Insp
ML17250B176
Person / Time
Site: Ginna 
Issue date: 05/08/1990
From: James Smith, Wachter K
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17250B173 List:
References
NUDOCS 9005310500
Download: ML17250B176 (142)


Text

Docket 0 o-a~

Accession 0 oo~

o a Date

/ /

of Ltr Regulatory Docket File ROCHESTER GAS AND ELECTRIC CORPORATION 89 EAST AVENUES ROCHESTERI NY 14649 MATERIALS ENGINEERING AND INSPECTION SERVICES

SUMMARY

EXAMINATIONREPORT FOR THE 1990 STEAM GENERATOR EDDY CURRENT INSPECTION AT R. E.

GINNA NUCLEAR POWER STATION REVISION 0 APRIL 25, 1990 REVISION 1 MAY 8,

1990 PREPARED BY:

DATE:

evi

. Wachter Mat ials Engineering and Inspection Services Level III Eddy Current Examiner REVIEWED/

APPROVED BY:

Jo n F. Smith, Manager Materials Engineering and Inspection Services DATE:

5 ~

0 9005'3 g 0500 5000244 0 90am<8 7

PDP ADOCK 0 PDC 9

II 1

r

TABLE OF CONTENTS 1.0 2.0 3.0 4.0

5.0 INTRODUCTION

DATA ACQUISITION PROGRAM DATA, ANALYSIS RESULTS

SUMMARY

OBSERVATIONS CORRECTIVE ACTIONS 10 40

J t

1.0 INTRODUCTION

The following is a

summary report of the results of the multifrequency eddy current examination performed during the April 1990 Annual Refueling and Maintenance Outage at the recirculating steam generators which Series-44 design.

Each generator contains 3260 Inconel 600 are Westinghouse Mil Annealed U-Bend tubes having an outside diameter of 0.875" and a nominal wall thickness of 0.050".

R. E. Ginna Nuclear Power Station in Ontario, New York. The examination was performed in both the "A"

and "B"

The purpose of the eddy current examination was to assess any I

corrosion or mechanical damage that may have occurred during the cycle since March 1989. Particular attention was given to the detection of:

1)

Intergrannular attack (IGA) and intergrannular stress corrosion cracking

'(IGSCC) within the inlet tubesheet crevice region.

2)

Intergrannular attack (IGA) and intergrannular stress corrosion cracking (IGSCC) within the outlet tubesheet, crevice region (none detected).

3)

.Primary water stress corrosion cracking (PWSCC) at the inlet tubesheet roll transition.

4)

Primary water stress corrosion cracking (PWSCC) at the outlet tubesheet roll transition (none detected).

Page 1 of 69

q1

5)

Pitting and wastage between the tubesheet and first support plate.

6)

Wear at the antivibration bar to tube intersections in the U-bend region.

7)

Denting at all tube support intersections.

8)

Primary water stress corrosion cracking (PWSCC) in the 9)

Row 1 and Row 2 U-bend area (none detected).

Intergrannular attack (IGA) and intergrannular stress corrosion cracking (IGSCC) at the g1 tube support plate region on the inlet side (none detected).

The examination was performed by personnel from Rochester Gas and Electric'(RG&E) and Allen Nuclear Associates, Inc.

(ANA).

All personnel were trained and qualified in the eddy current examination method and have been certified to a minimum of Level I for data acquisition and Level II for data analysis.

In addition, all acquisition personnel were trained and qualified to site specific procedures and all analysis personnel were trained and qualified to the site specific "Steam Generator Data Analysis Guidelines 1

Station".

These analysis guidelines were RG&E Ginna prepared is

'll accordance with Revision 2 of the Electric Power Research Institutes (EPRI)

"PWR Steam Generator Inspection Guidelines".

Page 2 of 69

r. s

~

I'

The data analysis was performed by two independent teams.

One team utilized the ZETEC Computer Data Screening (CDS)

System with a

manual review of the CDS calls.

The other team performed their analysis manually utilizing the Zetec DDA-4 Digital Data Analysis System.

The results of these two analyses were compared for discrepancies using the TUBAN computerized data management system.

The typical data flow chart is shown on Figure 1

(Page 5).

The following list describes some typical discrepancies between analysis teams requiring resolution by the Level III resolution team.

o Any indication that is reported as

>204 by either team 0

0 and is not reported by the other team or is sized at >104 indifference.

Any indication spanning the repair limit, (394 vs.

41%).

Any difference of >1 inch in the axial location of a 0

0 0

flaw.

Any tube which was analyzed by one team but not the other.

Any difference in the reported test extent.

All indications identified as IGA and/or SCC regardless of whether one or both parties have reported it.

0 0

Any tube reported as obstructed by one team but not the other.

Any tube for which a retest was requested by one team but not the other.

Page 3 of 69

o AllRoll Transition Indications (DRT/DRI) reported by one P

team but not the other.

In addition to the above, all tubes requiring repair whether reported by one or both teams were reviewed by the resolution team (usually consisting of two Level III individuals).

In all cases, the removal of a repairable indication from the data base required the concurrence of two Level III individuals.

Page 4 of 69

Dace Tape Coopucer Data ScreeninS v/ Hanual Review Kanual Analysis Data ManaSeaent Coaparison Do Results YES ASree 2

Resolucion YES epairable Indications 2

N Data ManaSeaent Eddy Curzenc Leal III S ceaa Caneracor Croup Figure 1

Page 5 of 69

I J

e

2.0 DATA AC UISITION PROGRAM The eddy current examination of the "A"

and "B"

steam generators was performed utilizing the Zetec Miz-18 Digital Data Acquisition System.

The frequencies selected were 400,

200, 100 and 25 kHz.

The selected frequencies were all operated in the differential and absolute modes.

The examination was performed primarily with a standard 0.740" or 0.720" O.D.

bobbin coil probe with smaller diameter probes used to traverse the smaller radius U-bends and dented regions.

Prior to examination of the steam generators, an inspection program was established for the inlet and outlet sides of both the "A" and "B" steam generators.

The inlet or hot leg examination program plan was generated to provide the examination of 1004 of each open unsleeved steam generator tube from the tube end to the first tube support, along with 204 of these tubes being selected and examined for their full length (204 random sample as recommended in the Electric Power Research Institute (EPRI) guidelines).

In addition, 204 of each type of sleeve was examined and the remaining tube examined full length. All previous tubes with indications greater than 204 through wall (TW) depth were examined as a

minimum to the location of their degradation.

All Row 1 and Page 6 of 69

Row 2 U-bend regions selected as part of the 204 random sample were examined with the Motorized Rotating Pancake Coil (MRPC) between the N6 TSP H and the N6 TSP C from the cold leg side.

Table 1 is a

breakdown, by steam generator, of all tubes examined and to the extent inspected.

Page 7 of 69

STEAM GENERATOR iiAn 1990 EDDY CURRENT INSPECTION EXTENTS PRIOR TO CORRECTIVE ACTION Total Tubes Out of Service Sleeved Tubes Open Unsleeved Tubes 3260 173 172 2915 REQ'D MIN Sleeves 35 Hot Leg to 41 TSP 2915 Full Length (20% Random) 583 Previous Ind.

> 204 9

NUMBER PROGM'D 2915 586 36 NUMBER INSPT'D 2915 585 35 COMPLETE 100.04 100. 34 100- 04 100.04 Table 1

'er Appendix B requirement.

Complete

= Tubes Inspected/Required Minimum.

Page 8 of 69

STEAM GENERATOR "B 1990 EDDY CURRENT INSPECTION EXTENTS PRIOR TO CORRECTIVE ACTION Total Tubes Out of Service Sleeved Tubes Open Unsleeved Tubes 3260 340 642 2278 Hot Leg to gl TSP Full Length (20% Random)

~

~

Previous Ind.

> 204 Sleeves Deplugged Tubes (F/L)

REQ'D MIN'278 456 19 129 28 NUMBER PROGM'D 2278 461 19 131 28 NUMBER INSPT'D 2278 460 19 131 28 COMPLETE 100.0%

100.94 100.04 101.64'00.04 NOTE:

15 additional tubes were examined from CTE to H6.

Table 1 (Cont'd)

'er Appendix B requirement.

Complete

= Tubes Inspected/Required Minimum.

'ne plugged tube listed on examination plan was not examined.

Page 9 of 69

l

3. 0 DATA ANALYSIS RESULTS

SUMMARY

The data analysis was performed using the Zetec DDA-4 Digital Data Analysis System and Edition 18.6 Revision 5 software with the CDS (Revision 27) and MRPC (Revision 13) supplements.

All data was reviewed by displaying the 400 kHz data on the CRT along with the vertical component of the differential and absolute mix outputs in strip chart form (where applicable).

Other frequencies and their components were selected as necessary for the evaluation of indications.

All recordable indications were logged into the computer and stored on floppy disk.

The final report form summarizing all indications

>204 TW (including IGA and PWSCC which is assumed to be >204) for each generator can be found in Table 2.

An explanation of the abbreviations and nomenclature used on these lists has been compiled for ease of interpretation.

Table 3 has been compiled to show a list of the total number of dents at each axial elevation.

The dent indications on this table are only those with signal amplitudes that exceed the 5.0 volt (approximately 0.0025" diametric dent) recording criteria.

Page 10 of 69

c<

LIST OF >20 INDICATION AND CREVICE INDICATION NOMENCLATURE To of List Information ROW COL OUTAGE ROW number from the tube identification.

Column number from the tube identification.

Year examination was performed.

INDICATION.

Type of damage mechanism.

VALUE VOLTS LOCATION INCHES Percent through wall depth or code for non-measurable indications.

Amplitude of the measured indication signal response.

Reference point from which the indication was measured.

Axial distance from reference point.

Information Under Value XX% TW The measured percent TW depth of the indication..

ADI Absolute DriftIndication Signal which is indicative of IGA.

ADS

Absolute Drift Signal which may be indicative of IGA.

DRT Distorted Roll Transition may be indicative of PWSCC.

DRI Distorted Roll Indication indicative of PWSCC.

RTI Roll Transition Indication MRPC verified DRT Page 11 of 69.

4 W

LIST OF >204 INDICATIONAND CREVICE INDICATIONNOMENCLATURE CON'T Information Under LOCATION HTS PF

Primary face. of inlet tubesheet.

HTS SF

Secondary face of inlet tubesheet.

CTS TSP Tube Support Plate PF Primary

. face of outlet tubesheet.

CTS SF AVB

-XX.X Secondary face of outlet tubesheet.

Antivibration Bars Axial distance below the secondary face of the tubesheet or support plates where the indication is located.

+XX.X H

Axial distance above the secondary face of the tubesheet or support plates where the indication is located.

Hot Leg (inlet side)

Cold Leg (outlet side)

Page 12 of 69

J

~

Plant-'utage-R.

E. Binna Station 199!3 Resolution Generator:

A 1 1 Repov tab le Indi cat ions (2!4/tw and greater)

RQW COL INDICAT ION VALUE VOLTS LOCATION lNCHES 6

9 1<3 1

4.

67g6 5

778 14 2489 18 1!3 11 13 14 15 15 17 28 28 388 1!d 11 12 16 18 27 27 27ig 1<3 14 14 23 18 11ilil 1 N 22 13 17 47 12, 12 13 14 16 16 17 17 18

'8 18 19 19 2g8 2g 2g 2< j 2g 21 21 21 21 21 21 21 2 4 23 23 23 24 24 24 24 24 25 ROLL TRANS OD (genej.al

)

ROLL TRANS ROLL TRANS DISTORT ROLL ROLL TRANS OD SCC ROLL TRANS ROLL TRANS OD WASTAGE DISTORT ROLL OD WASTAGE ROLL TRANS DISTORT ROLL DISTORT, ROLL ROLL TRANS OD WASTAGE OD NASTAGE QD WASTAGE OD (general)

OD IGA OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE QD NASTAGE OD WASTAGE QD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE QD IGA OD SCC OD (general)

OD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE QD WASTAGE OD WASTAGE OD IBA QD SCC OD SCC OD WASTAGE OD WASTAGE OD WASTAGE QD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE OD NASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD NASTABE OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE 26 2g 28 2?

2g 24 AD 24 25 24 22 25

. 26

'23 34 AD 73 24 22 n2 2<3 AD 73 89 38 34 34 25 nS 21 34

~ 28 22

~ 26 21 24 28 2jrj e///

I//

/

/I

/

//

I//

e/

/

0//

I//

/

0/

0///

//////

/I TN TW TW TW TW TN TN TW TW TW TN TN TN TW TW TW TW TW TW.

TW TW TN TW TW TW TN TN TN TW TW TW TN TW TW TW TW TW TW TW TW TW TW TW TN TW TW TN TN TW TW TW

8. 58
2. 79

!d. 67

.1. 87 S ~ 34

<3. 67

g. 39 1.17 1.14
8. 63 3'9

!3. 93

1. 48
3. 82 3 ~ 49 1

~ rjj2 3'8

~.41 1

~ 94

8. 54 1

~ 28 1.. 45

1. 58
4. 47 4.!d 1 1

~ 35

1. 42 8.72
6. 47
1. 86 4, 21
1. 67 6 ~ 84
1. 88
3. 62 1

~ 53

!3. 61

1. 87 8.92
2. 25 2 ~ 91
4. 33
2. 81 4 ~ 42
1. 31 8 ~ 36 rd ~ 55 1

~ g8 1.'96

14. 24 1

~ 96

6. 66
1. 11
2. 64
1. 16 4 ~ 42
1. 51 1

~ 35 7.!33

4. 63
7. 43 2 ~ 68

%.89

5. 47
7. 82
4. 12 HTS PF AVB2PF PF SF PF SF PF PF HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF PF SF SF PF SF SF SF SF PF SF SF SF SF HTS HTS HTB HTS SF SF SF PF SF HTS HTS HTS HTS HTS AVB3 HTS HTS HTS HTS HTS HTB HTS HTB HTS HTS MTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF.

SF SF SF SF SF SF SF SF SF BF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF HTS SF HTS SF HTS SF HTB SF HTS SF HTS'F HTS BF

+

~.84 8 gg

+ 2 ~ $8

+ 2. 8!d

-19

~ 3<3

+ 2 ~ 73

-12.58

+ '2.55

+ 2.53

+

1. 6!3 19'8

+ 1.88

+ 2 ~ 46

-19. 6!3

-19.58

+ 2.59

+ 1. 83!

2 ~ 4!4 2 ~ 1!4

+ 1.18

+ 5. 4<3

+ 1.78

+ 1. S!3

+ 2.18'

=. 7r4

+ 3 ~ 38

+ 2.88

+ 2.58

+ 2 ~ r48

1. 98

+ 2.38

+ 1.48 1 38 2, 1<3

+

1.!i><3

+ 5.

~ 4

-14.38

8. 88

+ 1.68

+ 3. 1(j 2 ~ 5g

+ =. 4rd

+ 1. 5<3

+

1

~ 88

-17.48 7'g

-12.48

+

1. 3!3

+ ~.18

+ 3 ~ 88

+ 1.68 9<4

+ 1. 3<3

1. 88

+

1

~ 48

+ 2.!ij<8

+

~. 4!4

+ 2.18

+ 2.98 2 ~ 4!4

+ 3.88

+ 1.78

2. 18

+ 1.78 Table 2 Page 13 of 69

Plant:

Outage:

R ~

E.

Ginna Station 1 99!!3 Reso 1 ut ion Generator:

All Reportable Indications (28%tw and greater)

ROW 17 24 26 26

~8 9

24 17 17 23 23 24 25 27 3<d 38 34 48 48 48 14 23 24 25 15 15 34 11 24 25,

.8 28 24 28 28 2f 23 26 27 19 19 19 25 26 26 27 27 27 27 27 27 27 27 27 27 27 27 28

~8 28 28 28 28 29 3!d 3<8 38 38 313f 31 32 32 32

&2 33 33 33 33 34 34-34 OD OD OD OD OD DS OD OD OD OD OD OD OD OD OD OD OD OD OD QD DIS ROL ROL QD OD OD OD OD OD OD OD ROL OD OD RQL OD OD OD OD OD QD OD OD OD OD OD OD OD OD OD OD QD OD QD OD OD OD OD OD OD OD OD OD OD OD OD NASTAGE WASTAGE IGA BCC IBA IGA WASTAGE NASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE IGA IGA TORT ROLL L TRANS L,TRANS IGA SCC SCC WASTAGE WASTAGE NASTABE WASTAGE NASTAGE L TRANS WASTAGE WASTAGE L TRANS IGA WASTAGE WASTAGE NASTAGE WASTAGE WASTAGE WASTAGE NASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE NASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE WASTAGE IGA WASTAGE WASTAGE NABTABE SCC CQL INDICATION VALUE TW TW TW 24

%/

ADI 44 /

ADI ADI.

24 /

24, /

28 29 //

25 26 /

35 /

25 ADI

.,ADI TW TN TW TN TW T,N TW TW TW TW TW ADI 55 73 28 /

29 /

26 /

28 /

31 TN TW TW TN TW'W TN ADI 36 /

34 //

29 /

26 /

23 /

23 /

36 /

31 /

27 /

29 /

31 /

24

'24 28 /

'28 /

28 27 /

28 /

28 /

26 /

32 ADI 34

- 28 /

83 /

TW TW TW TW TW TW TW TW TW TW TW TM TW TM TW TN TW TM TW TW TN TW TW TW TW TW TW TW TN 28 /

TW 38 /

TM

9. 49
8. 88 6 ~ 74 8.3

~

6. 83
8. 35
4. 88 4 ~ 46
2. 13
6. 75 2, 58
7. 74
9. 81
l. 17

<d. 78

3. 35 2 ~ 37
4. 35 3 ~ 42
2. 91 1

~ 44

2. 85
1. 16
8. 56 8 ~ 58
1. 97 3 ~ 29
1. 79
7. 54
1. 21
2. 9!i>

4, 29

1. 66 3 ~ 88
3. 88 5 ~ 72
8. 82 3 ~ 72 9 ~ 47
7. 89 8 ~ 39
3. 68
3. 6!d
8. 98
5. 96
3. 51
12. 72
2. 84
9. 12 18 ~ 15
6. 41
1. 94
1. 94 5 ~ 84
2. 58
11. 39
4. 73
6. 59
8. 18
1. 34
4. 58
2. 69
2. 15
8. 72 1.!d8 HTS SF HTS SF HTS SF HTS SF HTS SF Hi HTS SF HTS SF MTS SF HTS SF HTS SF HTS SF MTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTB SF HTS SF HTS SF HTS PF HTS PF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF Hi HTS PF HTS SF HTS SF MTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF CTS SF CTS SF HTS SF HTS SF HTS SF HTS SF HTS SF

HTS SF HTS SF HTS SF CTS SF CTS SF HTB SF, HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF MTS SF HTS SF HTS SF HTS SF

+

+ 8.87

-18.>5

-16.85.

-18.24 8.88

14. 8>

+ 8.88

+ 1.48,

+

~

~ 48

+ 3.86

+ 1.37

+ 2 ~ 16

+ 2.67

+ 1.83 2 ~ 44

+

1

~ 64

+ 1.18

6. 53

-14.16

-19.48

+ 2 ~ 27 2 ~ 42

+ 3.87 17 ~ 52

-17.97

+ 2.33f2

+ 2.48

+

1

~ 48

+ 1.31

+ 2 ~ ~ 7

+ 3.88

+ 3.41,

+ 2 ~ 46

-18. 48

+ f.36

+ 1.69

+ 1.63

+ 1.47

+ 1.8>

2 ~ 43

+ 1.48

1. 48

+ 2 ~ 59

+ 2.84

+ 1.47

+ 2 ~ 88

+

1

~ 94

+ 2 ~ 49

+ 1.66

+ !d.78

+ 8 ~ 78

+ 8 ~ 78 2 ~ 89

+ 1.31 2 ~ 22

+ 2.67

+ 1.76

+ 1.59

-15. 48

+ 2.14

+ 2.58

+ 3.19 18.!i>3 VOLTS LOCATION INCHEB Table 2 (Cont'd)

Page 14 of 69

Plan t:

Outage-R.

E. Ginna Station 1998 Reeolution Steam Gener ator:

Al1'eportable Indications (28</tw and greater)

ROW 25 26 27 38 18 2g 21 25 25 27 39 15 2f 26 18 18 212f 24 25 25 4

16 23 25 25 26 18 18 28 25 25 26 28 7

17 18 18 22 24 24 26 27 27 34 34 34 34 34 34 34 35 35 35 35 55 35 35 35 35 35 35

&5 35 D5 36 36 36 36 37 37 37 37 37 37 37 37 37 37 37 37 38 38 38 38 38 38 38 iS 38 39 39 4</

4g 48 48 48 4g 4

4g 4<i'd 4g OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE ROLL TRANS OD IBA OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE QD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD (general)

OD (gener'a 1 )

DISTORT ROLL OD WASTAGE OD WASTAGE OD WASTAGE OD IGA OD WASTAGE DISTORT ROLL OD WASTAGE OD NASTAGE OD WASTAGE QD NASTABE OD WASTAGE OD WASTAGE OD NASTAGE QD WASTAGE OD WASTAGE OD WASTAGE OD IBA OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD, WASTAGE OD'ASTAGE OD NASTAGE OD WASTAGE OD WASTAGE QD WASTAGE OD WASTAGE OD WASTAGE DISTQRT ROLL ROLL TRANS OD NASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE CQL INDICATION 21 24 /

29 27 21 /

37 /

TW TM TW TW TW TW ADI 29 24 /

23 23 /

28

-2> //

0/

38 26 /

35 I 23 39

~ 8 /

22 /

31 /

ADI/

/

26 /

26 //

2g /

24 I 24 /

28 /

21 /

24 /

ADI 23 /

24 2g /

29 /

28 /

26 I 21 /

22 /

24 //

21 //

24 I 21 23 /

28 /

TW TW TN TW TW TN TW TW TW TM TW TW TN TM TW TW TW TW TW TW TW TW TW TW TM TN TW TW TN TW TW TN TW TW TW TW T.N TW TW TW TW TW TN TW 21 25 28 I

~ 25 24 21 21 24 /

TN TW TN TW TW TW TN TW VALUE

1. 48 2, 12

~.76

9. 74 6 ~ 52
g. 75 1..5
4. 18
4. 58
1. 83 1

~ 94

6. 49 5 ~ 37

~

~ 83

6. 48
6. 27
3. 52 5 ~ 76

<3. 79 3 ~ 97

6. 78
3. 54
2. 85
5. 34
2. 19
7. 15
i. 75
3. 46 6 ~ 59
4. 75
8. 88
5. 65
1. 44
7. 43
8. 92
6. 12 4 ~ 77
3. 93 8 ~ 92 1. 58
1. 96 1

~ 71

8. 99
6. 74 5.'5
9. 83
5. 87
8. 61
1. 98
5. 52 6 ~ 84
3. 81 2 ~ 87 6 ~ 15
11. 29
7. 36
2. 14
2. 77
1. 37
1. 68
l. >8
1. 38
1. 58
6. 63
8. 75
6. 13 CTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF SF SF SF PF SF SF SF SF SF SF SF SF SF SF SF SF SF AVB3 HTS HTB HTS HTS HTS HTS HTS CTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS CTB CTS HTB HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS CTS HTS SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF BF SF SF SF SF SF SF SF SF PF SF SF SF SF SF SF SF SF

+ =.88

+ 1.99

+ 2.41

+

1

~ 68

+ 1.37

+ 1.37 2 ~ 26

3. 91

+

~.45

+ 2.26

+ 1.99

+ 2,23

+ 1.44

+ 1.26

+ 1.62

2. 8%

+ 1.53

+ 2.68

+ 1.29

8. 88
8. 88

-19. Sg

+ 1.94

+ 8.92

+ 1.43

-15. 98

+ 2.93

-19.32

+ 2 ~ 38

+ 2 ~ 85

+.1.67

+ 8.95

+ 2.15

+

1 ~ 28

+ 2.28

+ 1.58 2, f2

+ 8.42

-11. 3<9

+ 1.Sg

+ 1.88 2'g

+ 1.44

+ 1..38

+ 2 ~ 3&

+ 1.62

+ 2.14

+ 2.64 2 ~ 2g

+ 2.18

+ 1.43

+

1

~ 83

+ 2 ~ 15

+ 2.57

+ 1.93

, -19. 38

+

a

~ M%I

+ 2 2g

+ 2.59

+ 1.68

+ 1.27

+ 1.91

+ 2.19

+ 8.68

+ ~ ~

VOLTS LOCATION INCHES Table Z (Cont'd)

Page 15 of 69

4 0

Plant:

Qutage-R.

E.

Ginna Station 1998 Resolution Generator:

All Reportable Indications (28/tw and greater)

RQW 27 ZS 3Q 18 24 25 26 26 28 28 3g 24 27 37

. w7

&7 3?.8 28 24 24 27 27

~8 286 15 15 17 18 18 22 27 28 f2 13 14 15 19 21 27 28 28 28 38 14 19 31 13 18 COL 48 48 48 4g 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42r 42 42 43 43 43 43 43 43 43 43 44 44.

44 44 44 44 44 44 44 44 44 44 44 44 45 45 45 45 45 45 45 45 45 45 45 45 45 46 46 46 46 46 47 47 47 INDICATION OD WASTAGE OD NASTABE OD IGA OD IGA OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE QD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD (general)

OD (general)

OD (general)

QD (general)

OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE DISTORT ROLL OD NASTAGE OD SCC QD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD NASTABE OD WASTAGE DISTORT ROLL OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD SCC OD SCC OD'ASTAGE OD WASTAGE OD WASTAGE OD NASTAGE OD WASTAGE QD WASTAGE OD WASTAGE OD WASTAGE QD WASTAGE ROLL TRANS OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE ROLL TRANS ROLL TRANS OD WASTAGE VAL AD AD 36 24 2S 24 27 28 24 29 II/I/

/II//

/

I//

22 2g 24 35 27 23 25 2f 34 //

/

28 24 96

~4 2g 36 29 27 32 24 w34 28 2!d 64 81

~ w6.8

~ 22 Uf I/I

/

r/I I//I

////

e//

I I.I

/

>8 28

/

/

27 w -g4 26 TW TW TW TN TW TW TW TN TW TN TN TM TN TM TW TM TW TW TN TN TN TN TW TW TW TW TN TW TW TN TN TW TW rW TW TN TW TW TN TM TW TN TW TN TW TM TW TW TN TW TN TW TW TW TW T(J TW TW TW

6. 58
6. 38
2. <93 2, 32

<9. 96

1. 27
4. 27
8. 28 4 ~ 31 4 ~ 62
4. 71

=. 5S 3.!d5

2. 19 3 ~ 81
6. 87
2. 81
5. 75
8. 63 5 ~ 41
3. 82
3. 37 1 ~ 23 8 ~ 71

~.26

8. 68
4. 18 1

~ 89

4. 19
8. 88 1. 52
1. 18

!d. 57 8 ~ 76 8 ~ 79

8. 48
1. 45
1. 63
8. 88 6 ~ 34
8. 85
18. 41
8. 46
5. 69
4. 38
1. 49 rd. 58 3 ~ 86
8. 79

=. 96

7. 62
3. 38
1. 69
6. 98
3. 94
2. 54 f.66
18. 78
8. 56
8. 73
7. 39 2 ~ 38
2. 99
7. 85
8. 75 HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF AVB1 AVB2 AVB3 AVB4 HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS BF CTS SF HTS SF HTB SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTB SF HTS SF HTS SF HTS SF HTS PF HTS PF HTS SF VOLTS LOCATION INCHES 2 ~ 62

+ 2.14

6. 94

=13. 69 2 ~ 12

+ 1.83

+ 1.93

+ 1.8$

+ 2.13

+ 2.75

+

1

~ 77

+ 2.65

+ 2.19 1.2g

+

1

~ 82

+ 1.73 2r

~ td f

8. 88

<3. 8!d

8. 88 8 ~ gr f ~ 2g

+ 1.58

+ 2.53

+ 2.83

+ 2.58

+ 1.17

-f9. 9!d Sg

2. jr'

.w ~ 37

+ 2.18

+ 2.88 2,gg

+ 2.18

-19. 29

1. 48

+ 2 ~ 83

+ 1.28

+

1

~ 65

+ =.11

1. 87
4. 48

-11. 4!i>.

+ 3.68

+ 1.36

+

!d ~ 87

+ 8.95

+ 1.32

+ 1.88

+ 8.67

+ 1.68

+

1

~ !d4 2 ~ 48

+ 9.85

+ 1.23

+ 1.28

+

+ 2.43

+ 2.48

+ 2.78 Table 2 (Cont'd)

Page 16 of 69

1

Plant:

Outage:

R ~

E.

Ginna Stat ion 1998 Resolution Steam Generator:

All Reportable Indications (2!ij/tw and greater)

ROW 2f 22 3!d 34 1

14 14 19 26 28 286 16 2g 24 27 27 37 19 24nj 1

1 16 13 18 16 17 19 13 18 27 88 13 15 16 17 16 17 19 28 38 34 18 24 24.

28 34 17 19 2g

~<d 24 47 47 47 47 48 49 49 49 49 49 49 49 49 58 5!d 58 5!3 5<3 59 58 58 51 51 51 51 52 52 52 5=

'53 53 53 5>

54 54 54 54 54 55 55 55 55 55 55 55 56 56 56 56 56 56 57 57 57 57 57 57 57 58 588 58 58 ROLL TRANS OD WASTAGE OD WASTAGE ROLL TRANS OD SCC OD WASTAGE OD IGA OD WASTAGE OD IGA OD NASTAGE OD WASTAGE QD WASTAGE OD WASTAGE ROLL TRANS OD WASTAGE OD NASTASE QD WASTAGE OD NASTAGE OD WASTAGE OD WASTAGE OD (general

)

OD WASTAGE ROLL TRANS OD WASTAGE QD NASTASE OD SCC OD SCC OD SCC ROLL TRANS OD NASTAGE QD WASTAGE OD SCC OD WASTAGE QD WASTAGE OD WASTAGE QD SCC OD WASTAGE OD WASTAGE ROLL TRANS OD WASTAGE OD SCC OD SCC OD SCC OD WASTAGE OD WASTAGE OD NASTABE OD WASTAGE OD SCC OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD SCC OD ISA OD WASTAGE DISTORT ROLL OD WASTAGE ROLL TRANS OD WASTAGE OD SCC OD NASTABE OD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE CQL INDICATION VALUE TN TW TN TW TW TW TW TW TW 35 2g 27 28 2g 2g 27 3g 22 45 58 21 8!ij 26 34 28 77 32 2f 39 32 I~

2<3 31

-32 23 25 95 ADI

//

//

//

/

/

I 0/

y

/I/I

/

e//

/

/

///

TW TN 7N TN TW TN TN TW TN TW TW TW TW TW TW TW TW TW TW TN TW TM TW TW TW TN TN TW TN TW TW TW TW TW TN TW TN 31 96 28 24 35 22 0/

/

//

TW TW TN TW TW TW TN TW 22 /

78 /

32 ADI 31 ADI 34 21 /

24 /

25 /

5. 68

<3. 99

9. 82
1. 44

!d. 53

!3. 69 5.!ij4

8. 59
2. 54
8. 83
5. 87
9. 35 8 ~ 48
24. 36
1. 27
1. 16
i. 88
2. 11 2 ~ 8g
4. 99
8. 13
3. 81 1.!35
1. 84
8. 39
8. 55
8. 45
7. 48
4. 25
8. 44
2. 17 f, 22
2. <36
8. 46 2 ~ 8 9 ~ 29

!3. 69

!d. 64

8. 28
8. 38
1. 84

!d. 79

6. 58
1. 88
g. 31
1. 14 1.61
8. 85
1. 74 4 ~ 61
8. 43
4. 67
18. 85
8. 28
8. 78
5. 82
1. 34

!d. 65

8. 71
8. 51
1. 84
1. 83 2 ~ 42 HTS PF CTS SF HTB SF HTS PF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF CTB SF HTS SF HTS SF HTS SF HTS SF HTS SF AVB3 HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTB SF HTS SF HTB SF HTS SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF HTS SF

+ 2.49

+ 1.88

+ 8.95 2 ~ 27

-19. 58

+

<3. 5!3

5. <3!d

+ 3.68

-11. 52

+ 1.1!3

+ f.4rd

+ 8.4<3

+ 1.48

+

1. 9!d 2 ~ 2<3

+ 1.98

+ 1.48

+ 2.88 8'g

!3. 88

+ 1.78

+ 1.58

+ f.

8'16.18

-17. 3!d

-17.98

+ 2.48

+

1.8<3

+ =.88

-16. 78

5. 5!3

+ 3.98

+

.28

-15. 7<3

+ 2.88

+ 2.68

+ 2.58

+

1. 5<3

-17. 1!d

-17. 6<3

-18. 48

+ 1.58

+ 4 ~ 58

4. 1!3

+ 4.38

16. 2<3

+ 4. 2!3

+ 3.54

+ 1.25

+ 8.61

-18. 58

-17. 87

+ 1.45

-19. 44

1. 48

+ 2.38

+ !3. 75

-1j. 35

+ 3 ~ 98

+ 1.83

+ 1.91 Q4

+ 1.37 VOLTS LQCATION INCHES Table 2 (Cont'd)

Page 17 of 69

4

%)

Plant:

Outage-R ~

E. Binna Station 1998 Resolution Generator:

All Reportable Indications (28/tw and Sveatev)

RON COL 25 58 59 17 59 INDICATION OD WASTAGE QD WASTAGE OD WASTAGE 9

2g 59 68 6!3 OD WASTAGE QD WASTAGE OD WASTAGE 2g 73

~f "13 13 14 15 17 19 28 25 12 18 198 13 17 2g 21 25 13 13 a4 14 16 17 18 19 9

1!3 11il 15 18 f<3 2

114 15 18 19 28 2f 31 7

9if 11 13 19 2f 38 38 68 OD WASTAGE 68 QD WASTAGE 6!3 OD WASTAGE 6!d ROLL TRANS 61 QD NASTAGE 61 OD WASTAGE bl 'D WASTAGE 61 OD WASTAGE 61 QD NASTABE 61 OD WASTAGE 61 QD WASTAGE 61 QD WASTAGE bl OD NASTAGE 62 OD WASTAGE 62 OD WASTAGE 62 OD WASTAGE 63 QD WASTAGE 63 OD WASTAGE 63 OD WASTAGE 63 OD WASTAGE 63 ROLL TRANS 63 'D IGA 63 ROLL TRANS 64 OD WASTAGE 64 OD WASTAGE 64 OD NASTABE 64 OD NASTAGE 64 OD WASTAGE 64 OD NASTABE 64 OD WASTAGE 64

, OD NASTAGE 64 OD WASTAGE 64 OD WASTAGE 65 OD WASTAGE 65 OD WASTAGE 65 OD WASTAGE 65 OD WASTAGE 65 OD WASTAGE 65 OD NASTAGE 66 OD NASTAGE 66 OD WASTAGE 66 OD WASTAGE 66 OD WASTAGE 66 OD WASTAGE 66 QD WASTAGE 66 OD WASTAGE 66 OD WASTAGE 66 OD WASTAGE 66 DISTORT ROLL 67 OD WASTAGE 67 OD IGA 67 QD WASTAGE 67 OD WASTAGE 67 OD WASTAGE 67 OD WASTAGE 67 OD WASTAGE 67 OD WASTAGE 67 OD (Senegal) 67 OD (general) 68 OD WASTAGE VAL 28 2f 21 28 n3 2g

/////

/I/

TW TW TW TW TW TW TW TW TW 28 25 nS 22 24 ni 2<i!

23 21 2&

ADI

/

0/

0///

//////

//

TW TW TW TN TW TW TW TW TW TW TN TW TW TW TW TM 23 /

26 /

29 /

23 /

24 /

.4 /

26 /

28 /

24 /

21 /

28 /

"3!3 /

26 26 /

25 28 /

26 /

27 26 /

2g /

29 /

26 /

28 /

ADI 23 /

.24 /

TW TW TW TW TW TN TN TW TW TW TW TN TW TW TW TW TW TW TW TW TW TW TW TW TN TM TN 29 TW 26

%,TW 21 /

TN 25 38 /

2!3 /

TW TW TW 22 TW 24 /

TN 1

~ 25

i. 61
3. 72
2. 31
1. 27
2. 28
8. 75

!d. 94

3. 46
1. 94
2. 51 1.3a
7. 1<3 7

1!d 4 ~ 23

5. 31
4. 38
2. 98
i. 88
4. 61
3. 91
7. 28 1.!d2 2 ~ 92
18. 53 3 ~ 18
2. 57

!3. 41

1. 73
6. 28
l. 91 7 ~ b9
l. <34
5. 34
7. 84
6. 18 9 ~ 25 4 ~ 68 8 ~ 66,
6. 98
7. 27 2 ~ 91 4 ~ 72
6. 64
5. 49 4 ~ 58 4 ~ 64 8 ~ 61
6. 28 8 ~ 34
5. 95 18.86 3.38
7. 66
1. 69
1. 87
5. 22 7 ~ 95
5. 85
5. 86
6. 18 5 ~ 51
2. 39
2. 99
4. 8>

5,!jf3 HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF SF SF SF SF SF SF PF SF SF SF SF SF SF SF SF SF SF SF SF SF SF PF PF PF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF HTS SF HTS SF HTS HTS HTS HTS HTS HTS SF SF SF SF SF SF AVB3 AVB4 HTS SF

1. 34

!d. 47

2. 38 1

~ 89

8. 33
i. 17 f ~ 42
1. 89 1'. 5a
2. 34 1. 55 1. 94 2 ~ 19
2. 25
1. 72
1. 58
1. 67 1. 69 8 ~ 89
1. 82
i. 44
i. 71
8. 47 2 ~ 47
1. 47
1. 39 2 ~ 34
3. Sf
2. 34
1. 48
2. 1<3
1. 7!d 2 ~ gg 1. 2!3
l. 4<3 1. 5!i>
l. 1!3
1. 28 i.

8

8. 5<!

<3. 6<3

8. SQ>
1. 8<3
1. 78
1. 58
8. 9<3 f.48
1. 4<3
1. 88
1. 78 1

~ 5!3

i. 78
1. 38
1. 48

-19.58

+ 8. 4!i>

-16.78

8. 88 1. 2<3
1. 6<3
1. 78
1. 98
8. 6!d 8.!dg
8. 88

=. 88 VOLTS LQCATION INCHES Table 2 (Cont'd)

Page 18 of 69

I

~

~

Plant:

Outage-R.

E. Ginna Stat ion 199!3 Resolution Steam Generator:

A All Reportable Indications (2<3/tw and greater)

RON COL INDICATION VALUE VOLTS LOCATION INCHES f2 14 165 f!i!

11 14 1566 1356 13688 128f2 13 16 17 185 16 11 68 68 68 69 69 69 7!d 7<3 7g 7g 78 71 71 71 71 72 7Q 72 73 73 73 74 74 74 74 74 74 76 87 91 OD WASTAGE OD 'WASTAGE QD SCC OD SCC OD WASTAGE OD WASTAGE OD NASTAGE OD SCC OD NASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD NASTAGE QD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE QD WASTAGE OD NASTAGE OD WASTAGE OD NASTAGE OD WASTAGE OD SCC OD IGA OD IGA OD WASTAGE QD WASTAGE OD WASTAGE 26 28 67 78 35 2g

~7 2<3 25 28 23 2<d

-9 f 28 2g 25'5 23 21 26 2g ADI ADI 28 36 2f

//

//

/

/

///

/

////

////

///

TW TW TW TW TW TW TW TN TW TW TW TW TW TN TW TW TW TW TW TW TW TW TW TW TW TN TW TW TW TW 4

9"-

2.

~ 4

l. 69
8. 9!i>
8. 44
1. 67 4 ~ g2
8. 91 1. 94
4. 66
4. 67
1. 15 7'9
8. 71
4. 18
1. 92
2. 65
5. 92 3.!d5
4. 42
l. 18
6. 21
18. 13 5.

8

6. 27
2. 11
8. 92
3. 68
4. 47
1. 11 1

~ 14

~

~

HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF

+ 1.78

+

1. 4~i!

-13. 2<3

19. 9<i!

+ 1.58

+ 2. <3!i>

+ 1.88

-19.38

+ 1.38

+ 1. 1!i!

+ 2. 1!d

+ 1.58

+ l. 1!3 1.43

+ 1.68

+

1

~ 68

+ 8.5!3

+ 8 ~ Bd<

+ 1.48

+ 8.7!d

+ 1. 8<3

+ 1.58

+ 1.38

+ 8.78

+ 1.38

+ 8 ~ 98

18. 9<3

-18. 58

-18. 1!3 8 7g

+12. 13

+ 1.88 TOTAL TUBES FOUND 325 TOTALINDICATIONSFOUND 428 Page 19 of 69

Plant:

Outage:

R.

E ~ Ginna Stat ion 199<8 Resolution Steam Generator-'ll RePortable Indications

(.8/ and greater) 18 18 18 17 il 172 192 7

17 11 17 11 16 24il 17 17 17 li 15 38 1622 2g 24 1

15 16 17 18 19 2g 22 24 2722 13 23 24 24 11 19 41 15 17 17 17 56678 11 13 1~

15 16 16 17 18 19 19 2g 2g 21 21 22 24 25 25 26 26 26 27 27 27 27 27 27 27 27 3g 38 38 3g OD (general

)

QD (general

)

QD (general )

ROLL TRANS OD (general )

ROLL TRANS OD SCC DISTORT ROLL OD IGA OD IBA OD IGA QD IGA ROLL TRANS OD IBA OD IGA DISTORT ROLL ROLL TRANS OD ISA OD WASTAGE OD, IGA OD IGA OD WASTAGE OD IGA ROLL TRANS DISTORT ROLL OD IGA QD WASTAGE DISTORT ROLL OD WASTAGE OD WASTAGE OD WASTAGE OD IGA QD IGA OD, SCC OD IGA QD WASTAGE OD WASTAGE OD IGA OD IGA OD IBA QD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD WASTAGE OD IGA OD SCC OD IGA OD WASTAGE OD WASTAGE OD WASTAGE OD* WASTAGE OD IGA OD ISA OD ISA OD WASTAGE OD IGA OD WASTAGE DISTORT ROLL OD IGA I

OD IGA OD WASTAGE QD !AASTAGE OD WASTAGE ROM CQL INDICATION VALUE

/

35 36 /

TW TW TW ADI ADI ADI ADI ADI ADI ADI 23 /

ADI ADI 2g /

ADI TM TW ADI 28 /

TM 28 25 /

2g /

ADI ADI 59 /

ADI TM TW TM TW

'25 /

TM 28 /

TM ADI ADI ADI 28 /

29 /

29 38 /

21 /

27 /

ADI 93 /

ADI/

24 /

2!d /

2g /

ADI ADI ADI 21 ADI 28 /

ADI ADI 2g 27 /

27 /

TW TM TW TW TW TW TM TW TM TW TW TW TW TW TW TW TW 26 /

TW

/

TW VOLTS

1. 88
2. 39
1. 97

!d. 88

2. 81
1. 54 8 ~ 68
3. 96 5 ~ 42 5.1"
6. 47
2. 89
8. 82
1. 67
8. 47
1. 29
8. 49
2. 58 9.'78
i. 68 1.3

~

8. 26 8 ~ 37
1. Yd6
2. 74 1. 75
1. 85
2. 31
18. 52
1. 74 l.. 23 3 ~ 18
1. 47
8. 77
13. 96
2. 56 11

~ 68

2. 83
2. 43
2. 45
8. 24
18. 81
16. 99
11. 82
6. 81
18. 83 1!d. 78
1. 78 8 ~ 88
7. 66 5 ~ 69 6 ~ 2g
1. 38
11. 94
8. 51 2 ~ g6
5. <39
13. 8!i>

g, 52

8. 61
1. 43
8. Bg 2 ~ 42
8. 78
8. 62
1. 62 HTS HTS HTS SF SF SF LOCATION Cl C2 Ci HTS PF Cl HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTS SF HTS PF HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF INCHES
8. 88
8. 88
8. 88 2 ~ 4g

~3. 88

+ 2.85

18. 5<8

-19.43

-15'5

-17. 88

-15. 49 8 ~ 28

+ 2.96

-16. 88

+ 5.94

-19. 58

+ 3.83

-14.78

+

1

~ 48

15. 88

-18 ~ 88

+ 1.38

+ 4.57

+

~

~ 98

-19.68

-16. 58

+ 8.98 2ig ~ gg

+ 1.48 1. 28

+

1. 3!3

-18. ig8

-12.28

-18 F 88

-16.62

+ l. 1<d

+ 1.18

-17.48

17. 8<3

-17 ~ 28

+ 1.48

+

1

~ 38

+ 1.48

+

1. 3<3

+ 1.>!d

+

1. 5($

+ 1.58

-18. 4!d

-18'8

-15. 35

+ 1.28

+ 1. 5!d

+ 1.68

+ 1.48

4. 88

-17. <gi<>

13. 6<3 1

~ 4g

+ 5.56

+

1

~ 48

-19.68

-15.94 5'8

+ 1. 8!<')

+ 8.5<d

+ 2 ~ 8<8 Table 2 (Cont'd)

Page 20 of 69

Plant:

Outage:

R.

E ~ Ginna Station 1998 Resolut ion Steam Generator:

All Reportable Indications (28/ and greater)

ROW 24 28

~8 17 42 17 19 18 14 2f 212f8 31 31 34 24 41 41 24 a4 35 45 11 24 24

=5 34 36 7

24 28 44 6

6 778 14 31 417.

8'8 14 35 35 41 Z7 "8

48 14 3!3 39 31 33 34 34 34

~4 34 34 35 35 35 35 36 36 37 37 38 38 39 4.g 48 48 48 4!3 4!d 48 41 41 41 41 41 41 42 42 42 42 42 42 42 43 43 43 43 43 43 43 44 44 44 44 45 45 45 OD IGA OD SCC OD SCC OD WASTAGE OD (general)

OD IIA OD IGA QD IGA OD WASTAGE DISTORT ROLL OD BCC OD IGA ROLL TRANS DISTORT ROLL OD IGA OD SCC OD SCC OD IGA OD SCC OD IGA OD WASTAGE OD IGA OD SCC OD (general )

OD.(general)

OD WASTAGE OD WASTAGE OD IGA QD (general)

OD WASTAGE OD WASTAGE OD NABTABE OD WASTAGE OD WASTAGE OD IBA OD SCC OD IGA OD IGA DISTORT ROLL OD NASTAGE OD NASTAGE QD IBA QD SCC OD NASTAGE OD WASTAGE OD IGA OD IGA OD IGA OD IGA QD IGA OD IBA OD 'IGA QD IGA DISTORT ROLL OD WASTAGE OD IGA OD IGA OD SCC OD SCC OD WASTAGE OD IGA ROLL TRANS OD IGA OD SCC OD (general)

OD WASTAGE COL INDICATI QN VALUE ADI 69 TW 69 /

28 25 /

ADI ADI ADI 24 /

TW TW TW TW ADI 55 /

69 /

ADI 17 ADI ADI 82 /

38 /

21 /

ADI 3 /

34 /

23 /

26 /

28 /

2g /

ADI 96 /

ADI ADI 21 38 /

ADI 93 /

23 26 /

ADI ADI ADI ADI ADI ADI ADI ADI 2!i! /

ADI ADI 77 94 29 ADI ADI\\/

28 2<3 /

TN TW TW TN TW TW TN TW TW TW TW TW TW TN TN TW TW TN TW TN TW TN TN TW TN TW TN 81 /

TW ADI VOLTS

5. 98

.2. 84 2-55 g 66

4. 38
4. 94
8. 31
7. 58 2 ~ 23
2. 15
3. 99 1. 69
8. 75 3 ~ 85
3. 83 1. 58 3 ~ 96 4 ~ 49
8. 84
5. 82
4. 79
2. 18
1. 88
4. 84
2. 82
1. 96
4. 78
3. 81
1. 14
1. 3S 7 ~ 86
5. 33
8. '99
g. 83 4 ~ 26
1. 72
5. 38
4. 61
3. 38 3 >4
3. 54
1. 26 2 ~ 64
5. 16
4. 89 5 ~7. 3S
4. 71
3. 98
5. 95 4 ~ 27
6. 81 4 83
3. 26 6 ~ 58 8 ~ 73
3. 43

~ 1. 93

i. 81
1. 35

!3. 37

1. 85
2. 68 8 ~ 63
1. 28
g. 61 HTS SF HTS SF HTS SF HTS SF CTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTB SF HTS PF HTB PF HTS SF HTB SF HTB SF HTS SF HTS SF HTS SF HTS BF HTS SF HTS SF HTS SF HTS PF HTB PF HTB SF HTS BF HTB SF HTB SF HTS SF HTB SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTB SF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTS SF HTB SF HTS BF HTS SF HTS SF CTS SF HTS PF HTS SF HTS-SF HTS SF HTS SF HTS PF HTS PF HTS SF HTS SF HTS SF HTS SF

-15.18

-18.79

-16. 9<d

+ 1.38

+1S.28

18. 2!3

+ 2 ~ 96

-f5. 5<3 8 48

-19

~ 86!

-16.98

+ 4.13

+ 3.13

19. 7<3

-1S. 28

-17.18

-18. 28

-17. 98

-17.48

-15.'98

+ 1.48

-17 ~ 48

8. 4<3

+ 7.21

+ 6.89

+ 1. 1!3

+

1

~ 4<3

-17. 88

+41.68

+ !i!. 3<3

+ 1.78

+ 1.38 g 9g 2 ~ 4g

-18. 68

-18.78

-15.58 15 ~ 3!3

-19. 98 f

7<3 f, 2g

+18. 55 1 8 ~ 7Q>

+ 9.59

+ 8.68

-15.98 f6 ~ ti!!ij

-15. 5<3 5 ~ BS

-18. 3<3

-18.28

-16.!39

-14 ~ 38

-19. 48

+ 1.48

+ 4 ~ -6

-17. 4!d

-18.28

-18.<38

+ 2.5!3

+ 3.6

~

+ 1.74

-17. 38

-17. 98 g 3g

+ 1.38 LOCATION INCHES Table 2 (Cont'd)

Page 21 of 69

0

Plant:

Outage:

R.

E.

Ginna Station Steam 1998 Reeolution All Reportable Indicatione (2!i!/ and Gener ator:

greater) 45 26 45 31 41 2g 27 n7 32 4rd 38 18 32 38 38 8

352 34 35 3?

48 1

468 17 Q3 3g2 18 31 35il 13 24 25 27 38 28 2

f9 1

5 16 19 45 45 46 46 46 46 46 46 46 47 47 47 47 47 47 47 48 48 48 48 49 49 49 49 49 58 58 5!d 58 58 S<8 58 58 58 58 51 51 51 51 51 51 Cg 52 52 52 53 S3 54 54 54 54 54 55 55 55 55 55 OD IGA OD WASTAGE

.OD SCC OD WASTAGE ROLL TRANS OD WASTAGE OD NASTAGE OD IGA OD (general

)

ROLL TRANS OD WASTAGE OD WASTAGE OD IGA OD IGA OD WASTAGE OD IGA OD WASTAGE QD WASTAGE OD SCC OD IGA ROLL TRANS OD IGA QD IGA OD WASTAGE OD SCC OD IGA OD IGA OD SCC OD SCC OD IGA OD IGA OD SCC OD SCC OD IGA OD IGA OD SCC QD IGA OD SCC QD WASTAGE QD SCC OD SCC OD IGA OD WASTAGE OD WASTAGE OD SCC OD SCC OD IGA OD IGA OD IGA OD WASTAGE OD WASTAGE OD WASTAGE OD SCC ROLL TRANS OD WASTAGE OD IGA OD SCC OD SCC OD IGA OD WASTAGE OD WASTAGE OD IGA OD SCC OD IGA OD IGA OD IGA ROW CQL INDICATION ADI 3!d /

5!d 29 /

TW TW TN 38 28 /

ADI/

.8 28 /

ADI ADI 41 /

ADI 2g /

75 ADI ADI ADI 24 84 ADI ADI 54 /

41 /

ADI ADl 69 /

72 /

ADI ADI

~

63 /

ADI 82 /

24 93 /

72 /

ADI 28 /

31 89 /

87 /

ADI ADI ADI

.21 /

26 82 /

2g /

ADI 44 /

45 /

ADI 28 24 /

ADI 48 /

ADI ADI ADI TW TW TW TW TW TN TW TM TW TW TW TW TN TN TW TM TM TN TN TW TM TN TW TM TW TN TW TN TW TN TN TN TW TW VALUE

~.98

8. 99
8. 52
2. 61
2. 18 8 ~ 73
1. 83 g 34
1. 1 f 1. 38 6 ~ 64
l. 16 3 ~ 37
3. 82
8. 77
8. 14
3. 88

!d. 58

8. 83
7. 34
8. 96
6. 74
4. 16
1. 77 8 ~ 82
6. 45 2e 23

<iJ ~ 31 g 48

9. 95 4 ~ 67
8. 62
8. 88
4. 85 42
l. 16
1. 76 8.

8

i. 93

!d. 54 g 58

8. 77
1. 21 2 ~ 24
8. 56
g. 78 3 ~ 84
2. 88 4 ~ 72

!d. 76

!i>. 81 1.28

8. 75
8. 75
8. 56
8. 72
8. 53
3. 88
9. 76
8. 88 9 ~ 51
8. 31

~

2 ~ fg

> ~ 96

3. 76 HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF SF PF SF SF PF SF PF SF HTS'SF HTS SF HTS HTS CTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF SF SF SF PF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF PF SF PF SF SF SF SF SF SF SF SF SF VOLTS LOCATION I

NCHES'16.88

+ 1.88

17. Srd

+

!d. 38

+ 2.35

+ 8 ~ 68

+ 8 ~ 78

+ 6.57

+ 3.48

+ 2.36

+

1.7<3 2 3g

-17. 48

-lb.88

+ 8.68

15. 2!d

+ 1.38 2.rg

-18. 26

+ 2.55

6. 86

-17.25

+ 3 ~ 98

-18.67

8. 83

-17. 18

-17. 13

-18. 47

-17. 19

-17. 88 1 l. 81

17. 14

-15. <8!d 16.88

-18. 4r<.>

9. 6<3

-18. 68

+ 3.45

-18. 14

-15. 87

-13 ~ 96

+ 2.68

+ 3.19

-1S.67 18 ~ 57

-16.88

-17. 8rd

5. 23

+ 3. 5<i!

+ 2.98

2. 69

-18. 27

+ 2.88

+ 4.87

+ 5 ~ f5 12 ~ 89

-1 b. 52

-17. 9<d

+ 2.2S

+ 4.78 17.!i>g

-14. 6!3

-12.88

-lb.98 19.68 Table 2 (Cont'd)

Page 22 of 69

Plant:

Outage:

R.

E.

Ginna Station 1998 Resolution Steam Generator:

All Repovtable lndirations

<2<3% and Sweater)

RON CQL I NDICATIQN VOLTS LOCATION INCHES 12 17 18 27 2

115 2g 22 25 25 31 36 39 485 13 2!8 4

21 58 11 12 14 17 17 17 27 2

15 18 19 27nj 1

16 19 28 22 27 28458 19 55 56 S6 56 56 56 56 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 58 58 58 58 58 58 59 59 59 59 6!d 6!3 6!i) 6!d 6!3 6<3 6!d 6!3 6!d 6g 61 61 62 62 62 62 62 62 63 63 63 63 63 63 63 63 63 64 64 64 64 64 OD WASTAGE OD SCC OD SCC ROLL TRANS OD IGA OD WASTAGE OD (qeneval)

OD IGA OD IGA ROLL TRANS OD WASTAGE ROLL TRANS OD WASTAGE OD,SCC QD SCC OD SCC OD SCC QD SCC OD SCC OD SCC C)D ISA OD SCC OD IGA OD IGA OD WASTAGE OD SCC OD SCC OD SCC OD IGA OD SCC OD SCC OD IGA OD SCC OD SCC OD IBA QD. IBA OD IGA

'D WASTAGE OD SCC OD IBA ROLL TRANS OD WASTAGE OD SCC OD SCC OD IGA OD IGA OD IBA QD SCC OD SCC OD NASTAGE QD IGA OD IGA OD IGA OD SCC QD SCC OD IGA OD SCC OD IGA QD WASTAGE OD WASTAGE QD WASTAGE OD IGA OD IGA OD IGA OD IGA OD WASTAGE 2!i> /

74 /'/

ADI 28 26 I ADI ADI TN TW TN TW TN 21 71 /

79 69 /

79 84 /

79 I 49 ADI 34 /

ADI ADI 23 69 /

86 /

92 /

ADI 82 /

42 /

ADI 86 26 ADI AD'I ADI 28 /

37 ADI 28 64 I 69 I ADI ADI ADI 88 I 25 /

ADI ADI ADI" 59 75 /

ADI 43 /

ADI

~

28 /

21 /

28 /

ADI ADI ADI ADI TW TW TW TW TW TW TW TW TW TN TW TW TW TN TW TM TN TW TW TW TW TW TM TW TW TW TN TW TN TM TW TW 24 I TN

1. 84

!3 ~ 95

2. 11 ga 55 g, 44
8. 98 1

!d5

3. 24
4. 88 2 ~ 24
8. 47 1

~ 59

1. 58
8. 44
8. 59 8 ~ 36
8. 69

!3 ~ 62 g 31

!3. 95 1. 33 8 ~ 68

2. 49 3.!37
3. 15

<3. 41

8. 57
1. 82
5. 67

<3. 67 g7. 74 42 8 ~ 37

1. 93 2 ~ 25 4 ~ 44
3. 51 8.7

~

8. 61
28. 93
1. S5 1

~ 52 Do Sa 4 ~ 85 5 ~ 34 g, 52 g 64

3. 69 6 ~ 3!8 3 ~ 95
4. <3<3
1. 83

!d. 75

6. 68 g, 27
1. 88 1}.36
1. 76 4 ~ 37
1. 65 2, ig
1. 57
8. 88 HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF SF SF PF PF SF SF SF SF PF SF PF SF SF SF SF SF SF SF SF PF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF PF PF SF SF SF SF SF SF SF'F SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF g 96

-17'8

-18.95 67

+ 5.21

+ 3.8!3

+

<3. 4!d 15 ~ 8!d

17. i~id

+ 2 ~ 79 2 ~

+ 2.91

+ 1.68

-17. 8!3

-18.48

-17. 6!d

-14. 82

-14 ~ 59

-17.48

-18. 43

+ 3.38

18. }<3

-14.18

-}6.25

+ 2.35

-}S. 43

-17. 84

-18 ~ 13

-14. 88

18. 2<3

-13. 2!d

5. 8<3

-17. 5!3

-16 ~ 58

-16. 78

-17 ~ 8!3 1 6

!d!d

+ !3. 81

17. 93 4 ~ 2g 2 57

+ 1.68

-18

~ 86

-13 ~ 96

-14. 6<9

-16.88

-12.38

-11.98

-13.17

+ 1.78 4.48 4.48

-16.S8

-18.45

-16.6>

-15.38

-18.5S

-14. }u)

+ 1.98

+ 1..78

+ 1.78

-12.28

-15. 1!d 18 ~ 78

-11.34

+ 1.98 Table 2 (Cont'd)

Page 23 of 69

Plant-'utage:

R.

E ~ Ginna Station 1998 Reeolut ion Generator:

All Reportable Indicatione (28/ and greater) 24 25 64 1227 28 25 25 39 39 39 n<d 2i3 72 16 12 282

?

18 28 332 8

18 172 5

16 18 67 2<d 2

1 2

15574 n4 188 64 65 65 66 66 66 66 66 67 67 67 67 67 67 67 67 67 67 67 68 68 68 78 78 78 71 71 72 73 73 74 74 74 75 75 75 75 75 75, 76 76 76 76 76 77 77 77 77 77 77 78 78 78 79 88 8!d 88 88 81 82 83 83 84 85 OD OD OD OD OD OD OD QD OD OD OD OD QD QD OD OD OD OD OD OD DS QD OD QD OD OD OD OD OD OD OD OD OD OD OD OD OD OD IGA IGA NASTAGE SCC SCC SCC SCC SCC lGA IGA SCC SCC WASTAGE SCC SCC SCC (general

)

(general

)

(general

)

(general

)

SCC SCC IGA SCC WASTAGE SCC SCC IGA SCC SCC IGA IGA SCC IGA SCC IGA WASTAGE DISTORT ROLL OD OD OD OD OD OD QD OD QD OD OD OD OD OD OD OD OD OD OD QD OD OD OD OD OD OD OD IGA SCC SCC IGA IGA IGA IGA SCC IGA IGA SCC SCC SCC IGA IGA IGA SCC IGA SCC SCC IGA IGA IGA SCC SCC SCC IGA ROW COL INDICATION VALUE ADI ADI 23 /

74 /

76 /

68 56 /

65 /

ADI ADI

~

68 /

68 21 /

73 /

93 /

83 /

27 /

27 /

28 /

28 /

65 /

72 ADI 85 /

21 /

78 /

76 /

ADI 86 /

94 /

ADI ADI 72 /

ADI 87 ADI 28 /

ADI 9<9 //

ADI ADI ADI ADI 86 /

ADI ADI 79 /

97 93 /

ADI ADI ADI 94 /

ADI 88 /

96 /

ADI ADI ADI 81 /

91 /

66 /

ADI TN TW TW TN TW TW I'N TW TN TN TW TN TN TN TW TW TW TW TN TW TN TW TW TW TW TW TW TN TN TW TW TN TN TW TW TN TN TN TW VOLTS LOCATION INCH

4. 83
1. 78 SF SF SF SF SF SF SF SF SF SF SF SF SF BF SF SF, SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF BF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF.

BF SF SF SF SF HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTB HTS HTS HTS HTS Ci C3 C3 C3 C2

'HTS HTS HTS HTS HTS MTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS MTS HTS HTS HTS HTS HTS HTS

-18.

-17.

+ 2 0

-18.

15 ~

18.

15.

-16.

16.

-16.

-16.

-17.

+ 8.

16.

-17.6.

<d,g,

<3.

8 ~g,

-16.

-18.

17.

-17.

1

-is.

-16.

16

'16.

-17.

-17.

-17.

-18 ~

-18.

17.

17.g,

-19.

-17.

-18.

-16.

-15 ~

-15.

-17

'17.

-16.

-16 '

7 ~

-18.

-18.

-15.

-18.

-17.

17.

-16 '

18.

17.

-17.

-16.

-16.

18.

-18.

-17

'18.

6. 41
8. 91
8. 88 2 ~ g2
1. 18 1. 94 Ze 77
8. 78
8. 8>
2. 38
1. 63

<if. 52 g 47 2 ~ 38

8. 87
i. 51
1. 36 8.64
l. 16
6. 47
2. 35
2. 96 1

~ 75 2.93 2 ~ 76

2. 41

~.18

2. 55
4. 58 3 ~ 53
6. 84 5 ~ 41
5. 27
1. 76
2. 32
4. 77
2. 18
4. 88
4. 58 4 ~ 17
3. 19
3. 72
i. 81 5.25
5. 58 8 ~i. 17
1. <88
5. 68 6 ~ 43
5. 88
l. 94
5. 27 4 ~ 26
2. 38 7.8

~

3. 75
5. 57
8. 36 2 ~ 24
8. 39
8. 84 ES 48 76 18 32 26 1<3 73 79 18 88 57 41 88 88 5!d fijg 88

+l!3 83

<<d8 51 74 48 88 88 68 1!d 48 78 73

<d <d 38 59 38 81 78 sn 34 g <<<d 1!3 88 55 79 87 88 45 38 88 78 bn 5?

3<3 98 76 n7 2g

<d2 74 83 78 55 58 96 Table 2 (Cont'd)

Page 24 of 69

Plant-R.

Outa8e:

1 Al E.

Ginna Station 998 Resolution I Reportable Indications Steam Gener ator:

8

<28/ and greater)

ROW COL 11 85 14 86 15 86 15 86 1

92 1

INDICATION OD IGA OD SCC OD SCC OD SCC OD WASTAGE OD WASTAGE VAL(JE ADI 89/TW 7

~ /

TW 77 /

TW 27 TW 28 /

TW

4. 46
8. 37
2. 17
8. 96
1. 4Z
l. 84 HTS SF HTS SF HTS SF HTS SF HTS SF CTS SF

-16.87

-15. 98

-17 ~ 69

-18. 29

+11.19

+11.24 VOLTS LOCATION INCHES TOTAL TUBES FOUND:

TOTALINDICATIONSFOUND:

282 336 Page 25 of 69

l 4

R<<L<L TU<<A<<<T<<l

<VCR 5 0) oosooe Tuesday APt' I

24 ~

<991

<2s2<<

P<< oosooo Pa~Je Plant-GINNA Outa8e-1998 Res.

Steam Generator-A VOLTS LOCATION (6. 88

6. 8!ij-11 1=. 8<3-1
18. 88-

~

>8. 88-S

>59. 99 TOTAt.

i.

~

~

z 4 ~

5 ~6.

7 ~

8 ~

9.

18.

11.

1%.

14 ~

15.

16.

17.

18.

19

'<ii~

21 '

Q ~

w4 25.

27.

Zg.ii ~

~2 ~

~~i~ e 34.

w'5 e

>6.

~>7 ~

38.

4!3 ~

41.

HTS PF HTS HID HTS SF HTS-Hi Hl Hl-H2 H2 H2-H ~

H~

H3-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB1

>AVBl AVB2

>AVB2

>AVB ~

AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4-C 5 C~

C3-C2 C2 C2-C 1 Cl Cl-CTS CTS SF CTS HID CTS PF OTHER

!ij 42 2

1 128 18

!3

!ii

'8

~e 87 1

!3

!3 8

g

!3 82 4

<3

<3 gg

!3 88 1

153i g

g 188 15 14 19 g4 1ggg 46 11 1g88g888

!ii 15 12 84 1

1 18

!ij

!3 54 18 188g

!ij 94 4iv "8g 88 8g 688g888g

<3 1<3 8

<<j 1

1 18 18 1

1g 188

<ij 82 45

<3 3g

<3 jij872 12

<jj

<3 8

<ij 8

<3 882'5

!ij 182g 1

128 8

g8 gi 2 <ij 82 25

<ij 1

8

<3 8

tij 6

18

!ii

<3 g

<3 88gg tij 78 1

3<

tij g8

!ii 2g88

<3 8

8 8

2 19

~s

!3

!3

<ii gg 15 19 Qj

<ij

<ij 8g8888g 18g Iij tij

!ij

!ij

<3

!ii

<3 g

!ij g

<ij

!ij

<jj 418 179 12 8

!<j

<3 15 19 62ai

<3 8

<Zi gi Iij tg g

1 1824 2

5 ig8 58

!i'OTALS PERCENTS 148 ia.8 781

35. 4 186
17. 3 199 118 S2 1876 18 ~ 5
18. 2 4 ~ 8 Table 3 Page 26 of 69

'l

ssssss

<<0<<

T<<<<A<<<T<<)

<V<:R. 5.8)ssssss Tussdsy

<<Ss< l

<2 ~ 2<<

<t<< ssssss ssssss Pa< Je 2

Plant:

6INNA Outage-'.99!3 Res.

Steam Generator:

A LOCATION OBSTRUCTED MILS

<618 618-679 68!d-699 7cdg-719 72!3-739

>739 TOTAL 1.

3 ~

5.6.7.8.9.

18

~

11.

13.

14

'5.

16.

17.

18.

19.

2g, 24

'5

'6.

~8 3Igj.

=.'-:':

35 ~

36.

37m 38.

39.

48 ~

41.

HTS PF HTS MID HTS SF HTS-Hl Hi Hl-H2 H2 H>-H3 H3 H3-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB1

>AVB1 AVB2

>AVB2

>AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4-C3 C3 C3-C2 C2 C2-Ci Ci Ci-CTS CTS SF CTS MID CTS PF OTHER TOTALS PERCENT:

!3

!ijg C(j

<3 8gg

'rd g8

<3 8g 8

8g

!3 g

!3 gg8888g8

!ij 88

!dggg8

!3 g

!d. 8 gg8g88 888g8

<ij 888g888g889888gg8ggg888gg8g 8

g g

!3 g

!(j

!3 88gg88

!3

!3 g8

!3

!ij.

gg

<ij 988 rd 88g

!d 8

!ij 88g88

!3 g8 8

8.!ij 888ggg8g r(j

!3 8g rd gg8gg

!d 8988ggg8gg8888

!d

!3 g8 8

rd 8.!3 tij 8889g98

!3 8

!ij

!ij 1

r(j 989g889 g

29

!3 8

td

!ij 89

!ij 98

!3

'!3

!d

!3 g

7 28 ~ 6 e

1

!ij tij 18 18g 8

<d 8

1 1

6g tij 8g888882

!3 18 1

!3

!ij

!d ggg 27

79. 4 1

C(j

!d

<ij 88 1

?89

'r9

!3 g8g862 19 9

!d

'CA g8

!ij ggg

!(j

!d

'Table 3 (Cont'd)

Page 27 of 69

<<<<o<<<<<<

RULC TURA<t<T<t)

!VCR, 5,0)<<oooo<<

Tuosdoy April 2'AS

<2<24 Pr< <<<<<<<<<<<<

oooo*<< Page F'1 an t:

G INNA Outage:

199<3 Res.

Steam Generator:

A BULGES VOLTS LOCATION 19.!dg

18. 88-}

2r3. <d!d-2

39. 8<3-3

>39.99 TOTAL 3.

5 ~

6.7.

8 ~9.

1!3.

1}.

14

~

15.

16

~

17.

18.

28.

22 ~

24

'5

~

26 ~

28.

32 ~

33 ~

34

~

35

~

36.7.

38 ~

39.

48.

41.

HTS PF HTS HID HTS SF HTS-H}

Hl Hl-H2 H

~

H'2-H3 H3 H3-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB}

>AVB}

AVB2

>AVB2

>AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4-C3 C3 C3-C2 C2 C2-Ci Ci Cl-CTS CTS.SF CTS HID CTS PF OTHER TOTALS PERCENT-gij 8

!ij

!iS88 g88

!3

<3

!ij 8

!ij tij 8gg

<3 g

!ij rd 8gg8ggg8g88

<8 8

!ij

!d 37 ~ 5 gg

<3 rji 8

<3 gg8 88ggg tij g

!ij

!ij rij r3 g8 888 tg g8gg

<3

<3

!ij rij g4

!ij8

58. 8 8gg tij g8888g tij 8

<3

!ijg

!ijg ilj U8g8g8g8 rij

!3

<3

!3 g8

<3 g88 1

<3 8

1 12 ~ 5 88 rij 8g' Ig g8 id g

i<j gt gg

<3 gg

<3 td 98 8

!ij 8

<3

<d gg td 8

<3 888 td 8

rd 8.8 g

rd

<d 8

<3 rji

<3 g9

!ij9 rd

!ij 89 rd 888g 8

td

<3 g

rij 0889 rd 8

td 8g E

tij td 9

g g

<3

<8 89 ig tjj ig

<3 g

rij

!3

<3

!S td 8

!ij

!ij

!3

<3 rij g

<ij g

!ij td g

ty id gg rd 8

g88 td Table 3 (Cont'd)

Page 28 of 69

AOLC TUQAM<TH)

(VCR 5 0)osssoo Tuesday APt'll 24m

!090

!212' eeeoeo

~11110 F age Plant:

GENNA Outage:

1998 Res.

Steam Gener ator' LOCATION 1 ~

HTS PF 2.

HTS HID 3.

HTS SF

4. HTS"HI 5.. H1
6. HI-H2 7.

H2 8.

H2-H3 9.

H3 18.

H3-H4 11.

H4 12.

H4-H5 13.

H5 14.

H5-Hb 15.

Hb 16.

>H6 17.

AVBI 1B.

>AVBI 19.

AVB2 28.

>AVB2 21.

>AVB3 22.

AVB3 23.

>AVB4 24.

AVB4 25.

>Cb 26.

Cb 27.

C6-C5 28.

C5 29.

C5-C4 38.

C4

31. C4M 32.

C3 33.

C3-C2 34.

C2 35.

C2"C1 36.

C1 37.

C1-CTS 38.

CTS SF 39.

CTS HID 48.

CTS PF 41.

OTHER OD SCC - /

TM SIlR

<28 28-39 48-59 68-69 78-79 88-89

>89 TOTAL 8

8 8

8 8

4 3

6 4

5 27 TOTALS :

PERCENT:

8 5

8.8 18.5 4

3 6

4 5

27 14 ~ 8 11.1 22.2 14.8 18.5 Table 3 (Cont'd)

Page 29 of 69

1

~

'10000RQ4L TUQ4N!TI1)

<VCR, 5,0)oooooo Tueadag Ate !'!

24'OOO oosoos I 'age F'I an t '

INNA Outage:

199!3 Rem.

Steam Gene..atua:

A LOCATION 1 ~

HTS PF 2.

HTS HID 3.

HTS SF 4.

HTS-H1 5.

H1 6.

H1"H2 7.

H2 8.

H2"H3 9.

H3 18.

H3-H4 11.

H4 12.

M4-H5 13.

H5 14.

H5-H6 15.

H6 16.

>H6 17.

AVBI 18.

>AVB1 19.

AVB2 28.

>AVB2 21.

>AVB3 22.

AVB3 23.

>AVB4 24.

AVB4 25.

>C6 26.

C6 27 ~ C6<5 28.

C5 29.

C5-C4 38.

C4 31.

C4-C3 32.

C3 33, C3-C2 34.

C2 35.

C2-C1 36.

C1 37.

C1-CTS 38.

CTS SF 39.

CTS IIID 48.

CTS PF 41 ~ OTHE OD IGA - ! TM ADI

<28 28-39 8

23 48-59 68-69 78-79 88-89

>89 TOTAL TOTALS :

PERCENT:

8 8

8.8 8.8 8

8 8

8 8.8 8.8 8.8 8.8 Table 3 (Cont'd)

Page 30 of 69

TVQAN<Tt4)

(VCR. 5.1)>>>>>>>>>>>>

Tu>>sd>>Y APe tl 21 ~

I090

~>>>>>>>>>> Page F'I an t:

G INNA Outage:

1 '99!3 Res.

Bteam Genevatov:

A OD NASTASE - / TN LOCATION UDS 1.

HTS PF 2.

HTS MID 3.

HTS SF

4. HTS-Hl
5. Hl
6. Hl-H2 7.

H2

8. H>-H3 9.

H3 18.

H3-H4 11.

H4 12.

H4-H5 13.

H5 14.

H5-Hb 15.

Hb lb.

>Hb 17.

AVB1 18.

>AVB1 19.

AVB2 28.

>AVB2 21.

>AVB3 22.

AVB3 23 'AVB4 24, AVB4 25.

>C6 26'6 27.

C6-C5 28.

C5 29.

C5-C4 38.

C4 31 '4-C3 32.

C3 33.

C3-C2 34.

C2

35. C2-Cl 36.

Cl

37. Cl<TS 38, CTS SF 39.

CTS MID 49.

CTS PF 41.

OTHER

<29 877 9

8 8

8 9

8 8

8 9

8 8

8 8

8 8

8 8

8 9

8 9

8 9

8 8

8 8

161 8

9 8

28-39 49-59 69-69 78-79 88-89 8

8 8

313 8

8 8

8 8

8 8

8 8

9 8

9 8

8 8

8 8

9 8

8 9

8 8

8 8

8 8

8 8

8 8

12 8

9 8

9

>89 TOTAL 9

8 8

1192 9

5 9

8 9

8 8

8 9

8 8

9 9

8 8

9 9

8 9

8 8

8 8

8 9

8 8

8 8

8 8

174 8

9 9

8 TOTALS :

PERCENT:

3 1942 8.2 76.8 326 23.8 8

8 9

8 9.8 8.8 8.8 8.8 Table 3 (Cont'd)

Page 31 of 69

0

I RORIC TUQANITH)

<VCR 5,0)<<<<<<<<<<<<

Tv<<<<d<<Y Ate tl 21 ~

1990

~<<<<<<<<<< Pa'ge Plant:

GONNA Outage:

i998 Res.

Steam Generator:

A LOCATION OD

( eneral) -

% PA (28 28-39 48-59 68-69 79-79 88-89

>89 TOTAL 2.

4.

5.

6.

7.

8.

9.

18.

11.

12.

13

'4.

15.

16.

17.

18.

19.

28, 21.

22.

23.

24, 25.

26.

27.

28I 29 39.

32.

34.

35.

36.

37.

38.

39.

48.

41.

HTS PF HTS HID HTS SF HTS-H1 H1 H1-H2 H2

'2-H3 H3 H3-H4 H4 H4-H5 H5 H5-Hb H6

>H6 AVB1

>AVB1 AVB2

>AVB2

>AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4M C3 C3"C2 C2 C2-C1 C1 C1-CTS CTS SF CTS HlD CTS PF OTHER 8

21 9

1 8

8 8

8 9

8 8

8 8

8 8

9 8

8 8

8 8

8 8

8 9

8 8

8 9

8 9

8 9

2 8

8 9

8 8

8 8

8 8

8 8

8 8

8 8

8 1

8 2

8 8

5

  • 8 8

8 8

9 8

9 8

8 8

8 8

8 8

8 8

8 8

8 21 TOTALS :

, 24 PERCENT:

69.8 4

12 8

19.9 M.9 9.8 8

8 8

8 8.8 8.9 9.8 8.8 Table 3 (Cont'd)

Page 32 of 69

soteLo RN TUBAN<T<t)

<VER 5 0) 4i+OOO Monday'Pe

< 1 25e

< <PO

<<41 27 PH 1041 10 Page P lan t:

G E NNA Outage:

1998 Res.

Steam Generator:

B DENT VOLTS LOCATEON

<6.8!ij 6 gg ll 12.!ij<3 1

18.88-2 3!ij.88-5

>59.99 TOTAL 4 ~

4 ~5.6.7.

8 ~

18.

11.

] 2 ~

13."

14.

15 ~

16.

17.

18.

19.

~~rjj,

~O ~

24

~

25.

27

~

28.

38.

'Tt 34.

~6.

37.

38.

- 39 ~

48.

41.

HTS PF HTS NED HTS SF HTS-Hl Hl Hl-H2 H2 H2-H3 H3 H3-H4 H4 H4-H5 H5 H5-H6 H6

)H6 AVBl

>AVBl AVB2

>AVB2

>AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4-C3 C3 C3-C2 C2 C2-Cl Cl Cl-CTS CTS SF CTS NED CTS PF OTHER g

7<gj 38g 1

13g

<3

<3 182

!ij 11 6

158

!ij

<2$

<3 8

!ij rg 8

?8 1

?!ij48 g

1 4

8588

!ij 2!d6 17 1

1 4

88g8g4 15 17 19 g8, 88

<3 g

36 8

1 18 8

1 188 58 186r 8

!ij 956 1888

<3 8g 18 1

588

!ij ig 88g8 16288 888g 18 185 2gg

<8 8

7848g53 rg rij

!ij 8

rij 3

4 8g 8g

!ij22 18g

<9 8i88 1

v3 g

188 8

252

!ij

'2ll 1

848 8

86 g

!ij8 g

!ij8 897 1

r g8 1

1g 1

<ij 8

tg 8

8

<3 g

4 8g 88

!ij rij 8

1

!3

!9 g

8g88 7

88gg8

<3 8

Iij gj

!ij fcj I/I 88 474 59

"!ij 198 21 5

31 38 g

!iS rij

<3 8

73 2rtj 7

85 12 1

5 14 4

97 jYj 8

TOTALS PERCENT:

315

26. 4 585 42 ~ 4 156 13.

1 128 18.1 71 6.8 25 '192

2. 1 Table 4 Page 33 of 69

~soon'I<

TU<<A<t<Ttl< tvN 5.0)eeoeoo

<<o<<day t<t< i<

25e

<09<<

P 1 an t -

G INNA Outage:

1998 Res.

<<i<27 p<t ooeooe Steam Generator:

B Page LOCATION OBSTRUCTED MILS

<618 618-679 688 699 7i38 719 728 739

)73/

TOTAL

~

~

4 ~5.

6 ~

7.8.

1!3.

11.

12.

14.

15.

16.

17.

18.

19.

2g,

~

~

~

25.

26.

27

'8.

3g.

31.

34 ~

35.

>6.

w'7 ~

38.

48.

41.

HTS PF HTS MID.

HTS SF HTS-H1 Hi Hi-H2 H2 H2-H3 H3 H3-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB1

>AVBi AVB.

>AVB2

)AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5-C4 C4 C4-C3 C3 C3-C2 C2 C2-C 1 Ci C1-CTS CTS SF CTS MID CTS PF OTHER TOTALS PERCENT-rd g8

<ij

!ij8

<3 g

!ij g

<3 gg.g ig 8r 8g8

!ij 8g88gg88 ig gg888 rd 8g88 8.!3 g

gg88g

<3 rij 8g8g8g8888

<3 8g re8 g

!3 88g8 g

<3 g8 88g8

<3 8.8 8

<3 g8

!ij 8

!ij

<ij 88 rd 8

<3 8

r<<j 8

!3 g

<3 gggg8ggg888g8gg8 13 ~ 3 g

g8g

<3 8

rd

<3

!ij

'3

<3 88g888

<3 g

<3 g

<d 2g88888

<3 e i3 8g888g88

13. 3.

td

!3

<3

!3

<3

<3 ig gg re888

<3 8

!if 888

<3

!ij 18.

8

!3 rd gg88

!ij td

<ij 88g88

28. <3 g88'4 1

18g

<ij g8g rd 88g rd 8888828g8 8

!ij g8gg8

<3 rd rd g

53. 3

<3 8

4 1

1 gj

<3 g

<3 rij g,

8

<3 88 tij

!ij 8

1 rd 88888

<3 td

!3

<3 88

<3

<3 ggg

<3 Table 4 (Cont'd)

Page 34 of 69

l

Rrt<C TU<<AN<T<rr

<VCR, 2 rrr>>>>>><<>>>>

Hond>>Y Aria'r t 2Jq t<r<<rr O>><22 rrrr >>>>>>>>>>>>

~>>>>>>>>>> Page Plan t -'

INIjA Outage-1998 Res.

Steam Generator:

B BfJLGES VOLTS LOCATION f18 ~ gg

}tjf ~ !if<if 1

2<if, <3<3

~<3.88-3

> ~V. 99 TOl AL i.

3e 5 ~6.7.8.

9 ~

19.

11.

2 ~

1 ~.

14.

15.

16.

17

~

18.

19.

2g.

21.

22 ~

~~~ ~

24 ~

25 ~

26.

28.

a<3.

O~ ~

~~~~ s

>4.

35.

w6.

Z7 ~

w8.

48.

41.

HTS PF HTS MID HTS SF HTS-Hl Hi Hi-H2 H2 H2-HZ H~

HZ-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB}

>AVB}

AVB2

>AVB2

)AVB3 AVBZ

>AVB4 AVB4

)C6 C6 C6-C5 C5 C5-C4 C4 C4-C3 C3 CZ-C2 C2 C2-C 1 Cl Ci-CTS CTS SF CTS MID CTS PF OTHER TOTALS PERCENT-g8 tif

!dgggg

!ij 8g

!3 8gg 8g rd

!ij

<3 g

g8 888

<3

<3 8

<3 ggg 8g g

8.8 rif g

<3

!ijg

!dg

!ij rd

<3

!ij8g8g g

tif rd cd g88

!dg

!ijg888 gg 8g8 66 ~ 7 g8 988 9

8 rd rd g8

<3 8g

<3 88 rd g

rd 88g8g8 88 g

rif 88g g

!3. 8 88

<d 888g888 tif 8

!d 8888

<8 9

<3

<ij 9g

<3 8889g 89 g

98 8

8 tif, g td

!ij td 1

tg 9

<3 8

g

<3 gg8

<3 888g

<3 88g8

<8 gg9888

!3 g

!t!f tif 8

8 ii) 82tjj 1g8

<3 tif

!ij

!3!

8 td

!cf

!if

<d 89gg88 rd 8888

<3 8

rd 8

9

<3

<d 9g

<3 8

Table 4 (Cont'd)

Page 35 of 69

I

ROLC TUQ4N<TM)

<VCR. 5.0)>>>>>>>>>>>>

Monday 4pwll 22 y lOOO

~>>>>>>>>>> Pao e F'I an t:

6 INNA Outage:

1998 Res.

Steam LTenerator:

8 OD SCC-LOCATION SQR

<28 28-39 48-59 68-69 78-79 89-89

>89 TOTAL 1.

HTS PF 2.

HTS HID 3.

HTS SF

4. HTS-Hl
5. Hl
6. Hl-E?

7.

H2 8.

H2-H3 9.

H3 19.

H3-H4 11.

H4 12.

H4-H5 13.

H5 14'5-H6 15.

Hb lb.

>Hb 17.

AVB1 18.

>AVB1 19.

AVB2 28.

>AVB2 21.

>AVB3 22.

AVB3 23.

>AVB4 24.

AVB4 25.

>C6 26.

C6

27. CbM 28.

C5 29.

C5-C4 38.

C4

31. C4<3 32.

C3 33.

C3-C2 34.

C2 35.

C2-Cl

36. Cl
37. Cl-CTS 38.

CTS SF 39.

CTS HID 48.

CTS PF 41.

OTHER 8

15 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8

,, 8 8

8 8

8 8

8

,8 8

8 8

8 8

8 8

8 8

8 8

8 21 8

8 9

8 8

8 8

8 9

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 9

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 17 8

8 8

8 8

8 9

8 9

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 9

8 8

8 8

8 8

8 8

8 9

TOTALS ':

PERCENT:

8 8.8 1.1 4.4 13 15 21 28 14.3 lb.5 23.1 22.8 17 18.7 91 Table 4 (Cont'd)

Page 36 of 69

sasosa R4Lc TU0ANcTNI (vcR. 5.elssssss Honday Ape 1 l 2$i TO9e Plant-GINNA Outage:

l998 Res.

~40%40 Pa'$e Steam Gener ator:

8 OD ISA X TW LOCATION 1 ~

HTS PF 2.

HTS HID 3.

HTS SF

4. HTS-Hl
5. Hl 6, Hl-H2 7.

H2 8.

H2-H3 9.

H3 18.

H3-H4 11.

H4

12. H4M 13.

H5 14.

H5-H6 15.

H6 16.

>H6 17.

AVB1 18.

>AVB1 19.

AVB2 28.

>AVB2 21.

>AVB3 22.

AVB3 23.

>AVB4 24.

AVB4 25.

>C6 26.

C6 27.

C6-C5 28.

C5 29.

C5-C4 39.

C4 31.

C4-C3 32.

C3 33.

C3-C2 34.

C2 35.

C2-Cl

36. Cl
37. Cl-CTS 38.

CTS SF 39.

CTS HIO 48.

CTS PF 41.

OTHER ADI

<28 28"39 8

126 48-59 68-69 78-79 89-89

>89 TOTAL 126 TOTALS:

126 8

8 PERCENT:

188.9 9.8 9.8 8

8 9

8 126 9.8 9.9 8.9 9.9 Table 4 (Cont'd)

Page 37 of 69

~ooiio ROC TUOAN!TH)

<VCR J.elseosso HOnday Arrll 2J>

iPPQ

~ooses Page Plant -

6 INNA Outage-199!3 Res.

Steam Generator:

B OD WASTAGE " %

TM LOCATION

<28 28-39 48-59 69"69 78-79 8&-89

>B9 TOTAL 1.

HTS PF 2.

HTS HID 3.

HTS SF

4. HTS-Hl
5. Hl
6. Hl-H2 7.

H2 8.

H2"H3 9.

H3 18.

H3-H4 11.

H4 12.

H4-H5 13.

H5 14.

H5-Hb 15.

H6 16.

>Hb 17.

AVBI 18.

>AVBl 19.

AVB2 29.

>AVB2 21.

>AVB3 22.

AVB3 23.

>AVB4 24.

AVB4 25.

>Cb 26.

C6 27.

C6-C5 28.

C5 29.

C5-C4 38'.

C4 31.

C4-C3 32.

C3 33.

C3-C2 34.

C2

35. C2-Cl
36. Cl
37. Cl-CTS 3B.

CTS SF 39.

CTS HID 48 ~

CTS PF 41.

OTHER 9

652 8

9 8

8 8

8 8

8 8

8 9

8 9

8 8

8 8

9 8

9 8

8 8

9 8

88, 8

8 197 8

8 8

9 74 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 9

8 8

8 9

8 9

8 8

8 8

8 8

8 8

8'8 8

8 8

727 118 9

8 9

8 TOTALS :

PERCENT:

8 768 77 8.8 98.7 9.2 1

8,1 8

8 8

9.8 9.8 8.9 8

838 8.8 Table 4 (Cont'd)

Page 38 of 69

i

~sssss RQC 1ESAN<TH)

<VCR. 5.4)ssssss Hondsy

!!sing'4 l QJ!

loSh5 44!25 PH ssssss ssssss Pa'ge Plant -

61NNA Outage-199!9 Res.

Steam Generator:

E!

2.

4.

5.

6.

7.

8.

9.

18.

11.

12.

13.

14.

15.

16.

17.

18.

19.

28.

21

'2.

23.

24.

25.

26 ~

27.

29 ~

38.

32.

'34 ~

35.

36.

37.

38.

39.

48.

41 ~

LOCATlON HTS PF HTS HlD HTS SF HTS"Hl Hl Hl-H2 H2 H2-H3 H3 H3-H4 H4 H4-H5 H5 H5-H6 H6

>H6 AVB1

>AVB1 AVB2

>AVB2

>AVB3 AVB3

>AVB4 AVB4

>C6 C6 C6-C5 C5 C5"C4 C4 C4-C3 C3 C3-C2 C2 C2<1 Cl Cl-CTS CTS SF CTS HID CTS PF OTHER TOTALS :

39 PERCENT:

63.9 OD

( eneral) - / TM (28 28-39 48-59 7

15 8

11.5 24.6 8.8 68-69 78-79 88-89

>89 TOTAL 8

48 8

8 8

8 8

8 8

8 8

8 8

8 8

1 8

8 1

8 8

8 8

8 8

8 2

1 8

4 2

8 1

8 8

8 8

8 8.8 8.8 8.8 8.8 Table 4 (Cont'd)

Page 39 of 69

4.0 OBSERVATIONS The results of the examination indicate that IGA and IGSCC continue to be active within the tubesheet crevice region on the inlet side of each steam generator.

As in the past, IGA/SCC is much more prevalent in the "B" steam generator with 108 new (plus 5 deplugged)

IGA indications and 49 new (plus 23 deplugged)

IGSCC indications reported.

In the "A" steam generator, 16 new IGA indications and 22 new IGSCC indications were reported.

The majority of the inlet tubesheet crevice corrosion indications are IGA/SCC of the mil-annealed 'Inconel 600 tube material.

This form of corrosion is believed to be the result of the tubesheet crevices forming an alkaline environment.

This environment has developed over the years as deposits and active species like sodium and phosphate, have

reacted, changing a neutral or inhibited, crevice into the aggressive environment that presently exists.

Table 5 shows the steam generator IGA/SCC history.

Page 40 of 69

lg

GINNA'S STEAM GENERATORS CREVICE CORROSION INDICATION HISTORY B-Steam Generator A-Steam Generator March 1979 December 1979 April 1980 November 1980 April 1981 February 1982 Not Sizeable 0-254 0

0 19 5

(0)

(0)

(0)

(0) 31 14 13 A-S/G B-S/G 26-504 51-754 76-100%

Total Total 2

0 (0) 2 5

0 (0) 11 October 1982 r

April 1983 1984 March 1985'7 11 (3) 23 3 (1) 15 0 (1) 7,(1) 9 (1) 16 15 27 (1)

(4)

(2) 59 51 69 February 1986 February 1987 February 1988 March 1988 March 1989 April 1990 3 (2) 9 (2) 150 (14) 108 (16) 1(2) 82 (17) 1 22 (3) 0 1

0 8 (1) 8 (3) 14 (1) 16 (3) 7 (2) 35 (2) 8 (6) 25 (5) 52 46 (13)

(34) 153 11 (2) 79 (8)

(7) 41 (0) 6 (24) 268 32 (11)

(38) 157 TOTALS 454 (55) 28 (5) 61 (5) 131 (16) 264 (35)

(116),

938 TABLE 5 Page 41 of 69

4.0 OBSERVATIONS CONT Along with IGA/SCC in the

crevice, PWSCC at the roll transition appears to have a slight increase in growth during the last operating cycle.

This mechanism was first addressed in 1989 and this year there were 23 PWSCC indications in "B" steam generator and 37 PWSCC indications in "A"

steam generator.

These numbers include tubes that may have PWSCC in combination with IGA or SCC in the crevice.

A large volume, typically <204 TW, wastage type condition exists just above the tubesheet secondary face of both generators.

A small percentage of the tubes, generally toward the center of the bundle, have this condition.

Several of the tubes did have penetrations

>204 TW.

One tube in the "B"

steam generator was listed for corrective action from this

~ condition.

These tubes were essentially unchanged from prior inspections.

It is believed that these wastage indications were caused by the original water chemistry when phosphate was used as a buffering medium.

Small indications of probable copper deposits were also found in the tubesheet crevice region randomly located throughout each steam generator.

Page 42 of 69

fl

4.0 OBSERVATIONS CONT Minor denting has been detected at the tubesheet secondary face for many years in both steam generators, primarily on the inlet side.

Denting was also detected at the 1st, 2nd and 6th tube support plates randomly throughout the generator, and in most cases was of greater magnitude on size than that at the tubesheet secondary side face.

In general, minor distortions of most of the tube support signals were seen.

The denting phenomenon and minor distortions at the tubesheet and support plates can be attributed to secondary side corrosion product buildup in the annular region between the tube outside surface and the carbon steel support member.

Comparisons with previous data indicates that a small increase

~in the extent or magnitude of denting has occurred from what has been detected by previous inspections.

Indications were detected at the support plates in the cold leg of the "B" steam generator in tube R39-C67.

A review of the data base and previous data revealed these indications to be present and were recorded.

Examination of these intersections with MRPC indicated shallow indications within the support plates believed to be less than 404 TW.

Due to, a distortion of the signal on the bobbin coil examination, this tube was preventatively plugged.

Page 43 of 69

4.0 OBSERVATIONS CONT Additional MRPC at tube intersections in the Hot Leg of both steam generators showed no indications within the support plates.

This sample included tubes with and without denting at the support intersection.

In summary, the "A" Steam Generator had 75 tubes that were found to have "new" tubesheet crevice indications.

The "B" Steam Generator had 180 "new" tubesheet crevice indications.

a There were six (6) tubes in the "A" Steam Generator and two (2) tubes in the "B" Steam Generator recorded with indications at the anti-vibration bar intersections.

These indications are greater than. 204 but less than the repair limit and have not changed significantly since previous examinations.

These tubes will be reexamined at the next inspection to reconfirm no active fretting wear damage mechanism exists.

In light of the fact that only a small number of tubes exhibit these indications, AVB fretting wear is not considered to be a major concern at this time but will be monitored for any growth during future outages.

Page 44 of 69

AP

5.0 CORRECTIVE ACTION Table 6 has been generated to identify tubes with crevice indications or with indications which exceed the repair criteria.

This table also shows the location and the axial extent of the indication and what corrective action was taken on these tubes.

Tubes requiring repair due to hot leg tubesheet crevice indications were identified by the appropriate codes:

an absolute drift indication signal (ADI) of the Mix-2 Channel along with the IGA designation and/or quantifiable IGSCC indications on the 400 kHz data.

There were 28 tubes deplugged in the "B" generator in an effort to return them to service.

These de-plugged tubes consisted of tubes with tubesheet crevice indications recorded in earlier outages.

These tubes were inspected full length to insure no indications existed that would prevent them from being returned to service.

The "A" steam generator had a total of 75 new repairable indications.

The "B" steam generator had a total of 183 new repairable indications (not counting the de-plugged tubes).

A Ginna Steam Generator Tube Inspection and Corrective Action History has been tabulated on Table 7.

Page 45 of 69

e" s

PLANT'INNA 1990 Outage Repairable Tubes GENERATOR, A

TOTAL TUBES'260 OUT OF SERVICE (0): i73

~ ~ PNSCC 57) r - SCC tSR) i os IQA (f8)

TOTAL TUBES ASSI6HHL 75

~

~

~

~

~

~

~

~

~

~

~

~ ~

o

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

pY'~ rt

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ o~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~rs

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

J

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

tY Pr 4

~

e O

D I

~ t

~

~

~ t

~

~

~

~

~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o

~

~

~

~

~

~

tott

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ s

~

~ ~ ~ ~

~

~

~

~

~

~

~

~

~

~

~

~

rrr.~M -re wr

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ o

~

~

~

~

~

~

~

~

~

~

t sI'st

~

~

e ~ t

~ r

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

-iW-e

. ~ s

~

's

~

e

~

~

~ ~

~ t

~

~

~

~

~

~

~

~

~

~

F 01

~

~

~

~

~

~

~

~

~

~

~

~

~ t'i

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ ~

~

~

~

~

~ ~ o

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ stot

~

~

~

~

~

~

~

~

~

~

~

~

t

~

~ t t

~ t ~

tttt t ~ tt tet ~

~ set hatt t.t"r

~

~

~

~

~

~

~

~

t

~

~

~

4

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

-o~-s+

~

~

~

~

~

~ k ~

~

~

~

~

~

~

~

~

~

~

~ ~

t ~ ot tt ~

~

tt.t t ~

~

~

~

~

~

~

~

~

~

"rro

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ s

~

~

~

~

~

~

~

~i

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ e ~

~

~

~

~

~

~

~

~

cion o ri t ~

~

~

~ o

~

~

~

~

~

~

~

~ 4 ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

Y'4 s'V s

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

VC

~ ~ ed

~ ~

~

~

t

~

~

~

~

~

~

~.

~ ~

cion

~

~

~

~

~

~

~

~

~"

~

~

~

~

~ ed ~

~

~

~

~

r1

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

ri'

~

~

~

~

~

~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ '1tttt

~ to

~

tttt

~ ed ~

t+-

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ e

~r

~ t ~ 4

~

~

~

~

~

~

~

~

~ ~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~

~

~

~

~

~

o

~

~

~

~

~

~

~

~

~ ~

F 1 rt ri

~

~

~

~

~

~

~

~

~ ed ~

~.s

~

~

sh cion

~

~

~

~

~

~

~ ~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ e

~

~

~

~

~

~

~

~

~

t

~

~

~

t ~ ~

~

~ ~ e

~

~

~

~

I

~ h~

~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~.t

~

~

~

~

~

~ ~

~

~

~ t

~

o

'P Pi

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

i i i

~

~

~

~

~ \\

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o rs

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ r

~

~

~

~

~

~

~

~

~

~ ~ or

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ 'r'\\

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o

~

~

~

~

~

~

~

~

~

~

~

~

~ o

~

~

~

~

~

~

~

~

~

~

~

~

re

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ re

~

e

~

~

~

~

~

~

~, ~

~

~ ot

~

~ ro 1'

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ t.

~

~ t ~

~

~

~

~

rt'

~ ~ ed

~

~

~

~

~ L ~

~

~

~

~

~

~

~

~

~

~

~

~

~

ately

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ +

~

~

~ k

~

~

~ ~

ro

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

t

~

~

~

~

~

~

~ ot

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

rre r

~

~

~

~

~

~

~

~

~

~

~

~

e r's

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ MF e')

~

~

~

~

~

~

0"e

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o ~

o

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

ZHLET tHot Lef)) - h faery Face COLQSS Figure Z

l

<<ssosa RM TllSAN<T<<)

<VCR 5

<<) soaoss

%+day Ar<'< 1 25'904

<<4 ~ 56 Ptl 101101 asooos f a JJe Plant-GINNA Outa8e-199!d Res.

QUERY: Repairable indi cat ians Steam Generatar-'

RON COL OUTAGE INDICATION VALUE VOLTS LOCATION IN( 'HES 28 4

f2 f,3 14 16 16 17 18 18 19

'7g

.8 21 22 25 25 26 27 27 27 1998 199<3 1998 199<3 1998 199!3 199<3 1998 1998 199!3 1998 1998 199!ii 199!i!

199!3 199!3 1998 f99!d 1998 1998 1998 1998 1998 199!3 1998 1998 1998 199!3 1998 199<3 199!3 199<i!

1998 1998 199rd 1998 1998 199<3 199$

199<3 199<3 199!d 199!i!

1998 1998 1998 1998 1998 1998 199!3 1998 1998 1998 1998 1998 199<3 1998 1998 1998 199!3 199rd 199!3 1998 1998 1998 1998 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

TYPE 1

ROLL TRANS PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEE VED TYF'E 1

ROLL TRANS SLEEVED DISTORT ROLL SLEEVED TYPE 1

ROLL TRANS PLUGGED PLUGGED OD WASTAGE OD SCC SLEEVED TYPE 1

ROLL TRANS SLEEVED OD WASTAGE TYPE 1

ROLL TRANS SLEEVED DISTORT ROLL SLEEVED TYPE 1

ROLL TRANS SLEEVED DISTORT ROLL SLEEVED OD WASTAGE DISTORT ROLL PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEEVED OD <general)

OD ISA SLEEVED OD SCC OD ISA SLEEVED OD SCC OD SCC OD IGA SLEEVED OD BCC OD IGA SLEEVED OD IGA SLEEVED OD IGA SLEEVED PLUGGED PLUGGED OD IGA OD IGA SLEEVED DISTORT ROLL ROLL TRANS SLEEVED TYPE 1

ROLL TRANS CE-NECH CE-MECH CE-NELD CE-<AELD CE-MF.'LD CE-NECH CE-NECH ll /

TN 26 TN CE-WELD CE-CRV 11 /

TW CE-MELD CE-MELD CE-CRV CE-WELD 1

~ /

TW CE-NECH CE-NECH CE-NFLD ADB ADI CE-WELD 73 TM ADI CE-MELD 73 /

TN 89 /

TW ADI CE-MP.'LD 44 /

TW ADI CE-WELD ADI CE-WELD ADI CE-NELD CE NLD S CE-NECH ADI ADI CE-MELD CE-WELD

11. 68
8. 58
1. 46

. 67

2. 96
l. 87
5. 34 l.4.
8. 67 1 83
8. 39 3a 57
l. 17 1.24 3.58
l. 14
3. 79
3. 62
1. 48
3. 82 3 ~ 71
3. 49
2. 54
l. 82 2 ~ 6 ">

1.

8

8. 61
1. 53
8. 36
8. 55
l. 31
8. 32
6. 74
6. 83
4. 88
4. 35 3 ~ 42
2. 91
l. 44
3. 49 2 g5 HTS SF HTS PF CTB PF HTS PF HTB SF HTS PF HTB PF HTS SF HTB PF HTS PF HTS SF HTS PF HTS BF HTS PF CTS PF HTS PF HTB BF HTS SF HTB PF HTS SF HTS PF HTS PF HTS SF HTS SF HTS PF HTS PF HTS SF HTS PF HTS SF HTS PF HTS PF HTS SF HTS PF HTS SF HTS SF CTS PF HTB PF HTS SF HTB PF HTS PF HTS SF HTS PF HTB PF HTS SF HTS PF HTS PF HTB BF HTS SF HTB BF HTS PF HTS SF HTS SF HTB PF HTS SF HTB PF HTS SF HTS PF HTS PF CTS PF HTS SF HTS SF HTS PF HTS SF HTS PF HTS PF HTS SF HTS F'F

-19.98

+ 2.84

-1 Y.

!3

+27.!3<i'd

-19. 88

+ 2. E!8

+27.88 1'/. 3!d

+27.!dg

'-1'i. 88

+

~ 73

+ 8 ~ 4!d

-1

~. 58

+27. d<<if

-1 7. 2<3

+ 2.55

+27.!dg g 4g

-19 ~ 88

+ 2.56

+27.88

-19.58

+27. 88

-19.58

+ 2.46

+27

~ 8!d

-19.68

+27 ~ <j!<0 2.:>'rd

-1~.58 19.58

+ 2.59

+27.!d8

16. 6!d

+ 5.4Id

+2/. 88

-14. 38

+ 5 ~ 24

+27. rd<d

7. 7!3 f2, 4rd

-17. 4r<.!

+27 gri!

-16.85

-1 8. 25

+27 ~ gg

-1 8.'>4

+

~ 7. 88

-14. 8'>

+27

~ 88

6. 53

-14. 16

+27. 88

-f9. 48

+27.88

-19.48 2 ~ 42 Table 6 Page 47 of 69

~oosss

<<<<lg T<<<<A<<<T<<>

<VCR, a.elssesos

<<a<i<<ay ~< <1 2J<

<Pate

<<4< JP P<<

0%%0%0 Page Plant:

Outage-B INNA199!d Res.

Steam Generator:

A QUERY: Repairable Indications ROW CQL OUTAGE INDICATION VALUE VQLTB LOCATION INCHEB

'Y,9 38 18 18 16 17 27 28 34 34 35 36 37 37 38 48 48 4!d 1998 199i3 1 99~8 1998 199~<.!

1998 1998 1998 1998 1998 1 99!d 199!3 1998 199!3 199<3 199!d 199g 1 99!3 1998 199!d 1 99!i>

199<d 1990 1998 1998 1 99<3 1998 199!d 1999<

199!i>

199<i!

199!3 199g 199!3 1998 199<3 199<9 1 99<3 1998 199!3i 1998 199!3 1998 1998 199!3 1998 1998 1998 199!d 199<

199!3 199<3 199!3 1998 1998 1 99<i!

199!3 1 99<3 1998 1998 1998 1998 1998 199<d 199<d 1998 Res.

Res.

Res'.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

SLEEVED OD (general)

OD (qeneral)

OD SCC OD SCC OD ISA PLUGGED F'LUGGED TYPE 1

ROLL TRANS SLEEVED TYPE 1

ROLL TRANS SLEEVED OD IGA OD WASTAGE SLEEVED OD WASTAGE OD IGA SLEEVED OD WASTAGE OD iWASTAGE OD WASTAGE QD SCC OD WASTAGE PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEEVED OD WASTAGE OD WASTAGE OD IGA OD NASTAGE OD WASTAGE OD NASTABE OD WASTAGE PLUGGED PLUGGED DISTORT ROLL SLEEVED OD IBA SLEEVED OD WASTAGE DISTORT ROLL OD WASTAGE PLUGGED PLUGGED OD WASTAGE OD IBA PLUGGED PLUGGED DISTORT ROLL SLEEVED QD WASTAGE QD WASTAGE OD WASTAGE TYPE 1

ROLL TRANS OD WASTAGE PLUGGED PLUGGED OD IGA OD IGA SLEE.;',VED DISTORT ROLL SLEEVED CE-CRV ADS ADS 55 /

TN 7" / TN ADI CE-MECH CE-MECH CE-(;RV CE-CRV ADI 14 /

TN CE-NELD 14 /

TN ADI CE-NELD 19 TN 29 TM 24 TN 83 TW 21 /

TN CE-MECH CE-MECH CE-MELD 14 TN 8%

TN ADI 17 TN 19 /

TW 14 /

TN 15 /

TM CE-NECH CE-NECH CE-WELD ADI CE-WELD 26 TW 25 /

TW CE-MECH CE-MECH 16 /

TW ADI CE-MECH CE-NECH LEAKLIM 19 /

TW 15 /

TW 7 /

TW 7 /

TW CE-NECH CE-MECH ADI ADI CE-NELD CE-WELD 2s 27 3.9"

<3. 56 g 58

i. 16
3. 54 2 ~ 98
5. 68
3. BS
3. 88

..77

6. 1<3
4. 58
1. 63
2. 76 2, 12
1. 8!d
1. 48
5. 68
1. 25
i. 41
4. 28
4. 18
1. 58
8. 74
8. 79
i. 88
2. 85 1

~ 75 S. 8!d

6. 59 4 ~ 75 1:34
1. 58
2. 14 1. 36
1. 23
8. 63
4. 61 2 ~ 77
3. <35 2.$ 3 2 ~ 32
l. 52 HTB HTS HTS HTS HTB HTS CTS HTS HTS HTS HTS HTS HTS HTS HTS PF SF BF SF SF PF PF PF SF PF PF SF F'F PF SF CTS SF HTS PF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF HTS SF CTS BF CTS PF HTB PF HTS SF HTS PF HTS PF HTB SF HTS SF HTS BF HTS SF HTB SF HTS SF CTS BF CTS PF HTS PF HTS SF HTS PF HTS SF HTB PF HTS SF HTS SF CTS SF CTS PF HTS PF HTS SF HTS SF CTS PF HTS PF HTb, SF HTS PF HTS SF HTS SF HTS SF HTS SF HTS PF CTS SF CTS PF HTS PF HTB BF HTv SF HTS PF HTS SF HTS PF

+27

~ 8!3

7. 73

-15. 21

17. 52
17. 97

+ 3.87

-19. 37

+ 2 ~ 2?

+27 gg

-19.52 2 ~ 46

+27. 88

- i E! ~ 48

+ 2.78

+27

~ 88

+ !i>.56

-15. 4!d

+27 ~ 8Id

+..69

+ 2.41

+ 1.99

-18'3

+ 2.88

-19. 5V

+27. 88

+ 3.85

+

=..':~a

3. Yi

+ 2.7d

+ 3e38

+ 2.48

+ 3.88

-19. 88

+27.!38

-15.98

+

~ 7 ~ 88

+ 2 ~ 85

-19. ~2 2 ~ 3!3

+ i. 1<3

11. 3!i>

-1'/

+

3

+ g

-192

+

~.,g

. <iS!i$

.69

.28

. '<<8

~ 38

. <dg

6. V4

-13. 6V

+27 ~ 8!ij

-19. 9<3

+27. 88 Table 6 (Contid)

Page 48 of 69

oooo>>>>

<<<<L!

TU<<A<<<T<<<

<VCR I)so>>os>>

<<o<<<<sy <<ps<<

2X<

<<<0<<

OS<50 pH os>>os>>

  • oooo>> Pa8e Plant:

6 INNA OU'tage 199!ij Res.

QUERY: Repaivab le Indicat iona Steam Generator:

A ROW COL OUTAGE INDICATION VALUE VOLTS LOCATION INCHES 15 44 24 44 14 45 15 45 14 46 47 13 47 21 47 34 47 1

48 19 49 6

58 24 51 52 6

52 1998 1999 1998 199!<.j 1998 1998 1998 199<3 1998 199!8 1998 199!3 1 99!ij 1998 1 99<j 1998 19Mj 199<3 199!3 199!3 1998 1998 1998 199!d 199!3 1998 199vd 1998 199<ij 1998 f998 199vd 1998 199<3 1998 1998 1998 1998 1998 1998 1998 199<3 1998 1998 1 99!3 1998 1 99!ij 199<3 1998 1998 1998 1998 199!3 1998 199!3 1999 1998 1998 199<3 199<3 1 99<d 1998 199<3 1998 1998 199vd f 99<ij Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

PLUGGED PLUGGED QD WASTAGE QD SCC PLUGGED PLUGGED OD WASTAGE QD WASTAGE DISTORT ROLL SLEEVED OD WASTAGE OD SCC SLEE VED OD SCC SLEEVED QD WASTAGE OD WASTAGE TYPE f.

ROLL TRANS SLEEVED QD WASTAGE OD WASTAGE TYPE 1

ROLL TRANS SLEEVED PLUGGED PLUGGED OD WASTAGE OD WASTAGE TYPE 1

ROLL TRANS PLUGGED PLUGGED OD WASTAGE TYPE 1

ROLL TRANS OD WASTAGE OD !AASTAGE PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEEVED OD SCC PLUGGED PLUGGED OD WASTAGE QD IGA PLUGGED PLUGGED OD WASTAGE OD IGA PLUGGED PLUGGED ROLL TRANS TYPE 1

SLEEVED ROLL TRANS OD WASTAGE TYPE 1

SLEEVED OD SCC OD SCC OD SCC PLUGGED PLUGGED ROLL TRANS CE MLD S CE-MECH 24 /

TW 96 /

TW CE-MECH CE-MECH 15 /

TW 7%

TN LEAKLIM 3 /

TW 64 TN CE-WELD 81

% TN CE-MELD 2/

TN 18 /

TW CE-MELD 14 /

TN 11 TW CE-WELD CE NLD S CE-MECH 15 /

TW 8/

TW CE-MECH CE-MECH 17 TW

'19 /

TN 12

% TN CE-MECH CE-MECH CE-MELD 78

% TN CE-MECH CE-MECH

/

TW ADI CE-MECH CE-MECH 19 /

TW ADI CE-MECH CE-MECH CE-MELD 18 TN CE-MELD 62 TN 45 /

TN 58 /

TW CE-MECH CE-MECH

!d. 76

<d. 57

1. 51
3. 68
6. 34 8 ~ 67
8. 58
3. 86
l. 16 i.. 18
4. 53 fg 7g
2. 26 2'15
3. vdl 2 ~ 99
1. 68 1

~ 25

4. 14
7. 85
2. 58
2. 57
5. 68
8. 7>
1. 78
5. B2
i. 44

!3 ~ 53

8. 59
5. 94
6. 18 2, 54
4. 18
3. 81

<9. 88

<3. 39 8 ~ 55 8 ~ 45

7. 48 HTS PF CTB PF HTS SF HTS SF CTS PF HTS PF HTS SF HTS SF HTB SF HTS PF HTS SF HTS BF HTS PF HTS SF HTS PF HTS SF HTS SF HTS SF HTS PF HTS PF HTB SF HTS BF HTS SF HTS PF HTS PF HTS PF CTS PF HTS SF HTS SF HTB SF HTS PF CTS PF "HTS PF HTS SF HTB SF HTS PF CTS SF CTS SF CTS PF HTS PF HTS SF HTS PF HTB PF HTS SF CTS PF HTS PF HTS SF HTS SF CTS PF HTB PF HTS SF HTS SF CTS PF HTS PF HTB'PF HTS SF HTS PF HTS PF HTS SF HTS SF HTS PF HTS SF HTS SF HTS SF CTB PF HTS PF HTS PF

+ 3.3)

2. 79

+ 1.61

+ 1.11

-1 <<. 29

+27 ~ Pljg

+ 3.44 4, 4g

+27. 88

-11. 4!3

+27. 8!ij

+ 3.48

+ 1.5S

19. 98

+ 2.48

+27. 88

+ 1.59

~ 8.8d

-28.88 2 ~ 43

+27. 89

+ 3.11

+ 1.86 19.!32

+ 2 4!d

+ f.14

19. 8

+ 1.7'

g. 7!d

-19. 49

'>7

+27. 88

-19. 59

+ 3.6vd

5. 98

+ 1.66

-11.52

+ 2.46

-28.18

+27 ~ <dg 2 ~ 43 1.98

19. 9<3 7 ~ 88

-16.18

-17. 3' 17 ~ 9<3 2 ~ 4<d Table 6 (Cont'd)

Page 49 of 69

R<<l C TU<<4<<< TH)

<VCR 5 0) It1010

<<Onday 4<< !1 2Ji

<090 04<JAN P<< asosts

'a9e Plant-OUta9e G INNA1998 Res.

Steam Gener a>or A

QUERY: Repairable Indications RON COL OUTAGE INDICATION VALUE VOLTS LOCATION IN(."HEB 27 34 18 34 3f 3f 4 2 16 53 54 54 55 55 56 57 57 57 68 63 63 66 67 6S 68 7<d 74 1998 199i3 199!3 199!3 f99!d 199i<<

1998 199!d 1 99!d 199!d 1998 1998 199!d 199!3 1 99!d 1 99!3 1998 199!3 1 99!d 1998 1 990>

1998 1998 1998 1998 1998 1998 1998 199!8 1998 1998 1998 1998 1998 1 99!d 199!d 1998 1998 f99g 1998 1998 1998 1998 1998 199!i>

199

1998 1998 1998 1998 1998 1998 1998 1998 1 99!3 199<3 1998 1998 f99!d 199<3 f99!3 1998 199q~

1998 1998 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

TYPE 1

SLEEVED OD WASTAGE OD SCC SLEEVED PLUGGED PLUGGED OD SCC SLEEVED ROLL TRANS OD WASTAGE TYPE 1

SLEEVED

~

OBSTRUCTED OD SCC SLEEVED OD SCC QD SCC SLEEVED OD NASTAGE OD SCC SLEEVED OD SCC SLEEVED OD WASTAGE OD WASTAGE OD IGA OD iAASTAGE PLUGGED PLUGGED OD WASTAGE OD WASTAGE OD WASTAGE DISTORT ROLL ROLL TRANS SLEEVED QD SCC SLEEVED PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEEVED OD WASTAGE TYPE 1

ROLL TRANS SLEEVED TYPE 1

OD IGA ROLL TRANS PLUGGED PLUGGED DISTORT ROLL PLUGGED PLUGGED OD WASTAGE QD IGA SLEEVED QD SCC SLEEVED OD (general)

OD SCC SLEFVED OD SCC SLEFVED QD SCC SLEFVED CE-NELD 3 /

TW 88 /

TN CE-WELD CE NLD S CE-MECH 77 /

TW CE-l4ELD 13 I TW CE-MELD 748 I1ILS I Tl4 CE-!AELD 32 /

TW 32 /

TN CE-WELD 4 /

TN 31 /

TW CE-!AELD 95 TM CE-NF.'LD

. 16 /

TW 15 /

TM ADI5%

TW CE-MECH CE-MECH I TN 31 /

T!A 5 /

TW CE-MELD 96 TM CE-WELD

.CE WLD S CE-I'1ECH CE-MELD TW CE-WELD ADI BAREHOLE CE NLD S BAREHOLE CE NLD S 13 /

TW ADI CE-WELD 67 I TW CE-MELD AD&

78 /. TW CE-WELD

/

TW CE-l4ELD 28 /

TM CE-WELD

2. 53 1.!33 S. 44 S. 46
9. 29
1. 55
4. 34
8. 64 g, 2B

!3. 38

8. 89

!3. 31

<3. 43

5. 38 2.!36 HTS HTS HTB HTS HTB HTS CTB HTS HTB HTS HTS HTS HTS HTS HTB HTS HTS HTB HTS HTB HTS HTS HTS HTS HTB HTS
1. 37 S. 7S
4. 81
8. 28
5. 82

!d. 65 2, 54

1. 94 7 ~ 17
2. 56
2. 57
4. 76
8. 41
1. 73
1. 69
2. 6f
5. 22 1

~ 69 5 ~ 4~

S. 98

!d. 91 S. 92 CTB HTS HTS HTS HTS HTB HTB HTS HTS HTS HTB CTS HTB HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS CTS HTS HTS CTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTB HTS HTS

4. 67 HTB
l. 5<d'TS SF PF BF SF PF PF PF SF PF PF SF SF PF SF SF PF SF SF PF SF SF PF BF PF SF PF PF SF SF SF BF PF PF BF PF PF PF SF PF PF SF SF PF PF SF PF PF PF PF SF PF PF SF BF PF BF PF bF SF PF SF PF SF PF

-28. 1!3

+27 ~ 8!d

+ 8.58

16. 7'd

+27. 8!d

15. 7!d

+27.88

+ 2.58

+

1

~ 2

-19

~ 78

+27 ~ !i>8

+34. 4!3

-17.18

+27 egg

-17.68

-fS.48

+27 frigg

+

1

~ 5!3

-16.28

+27 gg

-fB.SS

+27.88

+ 2.81 46

-17. 87

+ 1.71

1. '<<2

+ 1.48

+

1. 8!8 19 ~ 44

+27 ~ SS 17 ~ 35

+27. <dg

- 1'<<. 83

+

'='. 34

+27. 88

+ 1.52

19. 81

++27 ~ 8!d

-19. 32

+ 3.81 2 ~ 34

19. 58 g 58

-16. 78

+2j. <d<d

+.<7

!d<d 1 Et. 2!i>

-19.98

+27.8Ii!

-19..5~d

+2/. ScI

-18. Y<'<

+27 88 Table 6 (Cont'd)

Page 50 of 69

~oosss NLC TUOANCTH)

!VCR 5.0)ooeoae Honday A! ail QJi

!OOO 04sJO PH aaoaae 04110%

I age Plant:

6 INNA Outage:

1998 Res.

QUERY: Repairable Indications Steam Generator:

A RON COL OUTAGE INDICATION 17 74 1998 Res.

OD IGA 1998 Res.

SLEEVED 18 74 1998 Res.

OD IGA 1998 Res.

SLEEVED TOTAL TUBES FOUND TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE TOTAL TUBES INSPECTED VALUE ADI CE-MELD ADI CE-MELD 75 272 75 75 VOLTS LOCATION INCHES

5. 68 HTS SF

-1&. 58 HTS PF

+27.!3!8

4. 47 HTS SF

-18. lid HTS PF

~27.<88 Table 6 (Cont'd) page 51 of 69

PLANT:

6INMA

$990 Outage Repairable Tubes 6ENERATOR 8

TOTAL TUBES:

3260 OUT OF SERVICE(0)l 3i2

~ ~ RCCC 8?S)

X ~ SaataSe 0)

$ >SCC Pg H

Cold Ley Indication 0) a-ISA (ttS) o BN Sleeve 0)

TOTAL TUKS ASSIBHER HX

~

~

~

~

~

~

~

~

~

~

~ ~ at o

~ tt

~ ~ 1 'ed

~

++1+ +t+t t ~ 1

~

~

~

~

~

~

~

~

~ isl

~

~

~

~

~

~

~

~ at ~

~

~

~

~

~

~

~

~

~

~ t

~

~

~

~

t ~

~

~

~

~

~

~

~

~

1

~

~

~

~ ~ ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ e

~

~

~

~

l'1 rl

~

~

~

~

~

~

~

~

~ ~ PE

~

~

~

~

~

~

~

~

~

~

~

PTT"r

~

~

~

~

~

~

~ ~

~

~

~

~

~

~

~

~

~

~

~

~

rl l

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

1

~

~

~

~

~

~

~

~

~

~

~

~

~

~ 1 ~

o

~ o

~

~

~

~

~

~

~

o

~

~

~

~

~

~

~ o

~

~

~

~

~

re

~

~

~

~

~

~

~

~

~ ~ ~ ~

~

~

~

~

1 ~

~

~

~

~

~

~

o rl

~

~

~

~

~

~

~

~

~

~

~

~ rr

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ l V

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

)

~

e b're

~

~

~

~

~

j

~

~

~ ~

~

~

~

~

~

~ ~

~

~

~

~

~ ~ o

~

~

~

~

~

~

~

~

~

~

~

~

~

4 ~

~

~

~

~

~

~

V V lM

~ 4 ~ ~ $

~

~

~

~

l o'

~

4 ~

~

~

t l

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ 4

~

~

~

~

~

~

~

~

~ ~

~ ~

e T

~

~

~

~

~

~

~

~

~ ~ o

~

4

~

~ k

~s-w r-

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ at

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ 4

~ re AJAR

~

~

o ~

~ a

~

~

~ t i +

ot

~ ~

~

~ k ~

Y re't

~

~

~

~

~

~

~

~

~

~

~

~

~

~

'l J

~

~

~

~

e

~

~

~

~

~

~

~

~ ~

e

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

JP A ~

~

~

~

~

~

~

~

~

ll r'%o

~

~

~

~

~

~

~

~

~

~

~

~

t

~ t

~

-e "wr w~e 1-

~

~ 1

~

~ P

~

1 e-M

~

o ~ 1 t ~ ~

o o

~

~

~ ~ to

~

~ ~ ~

~ t ~ ~

~ ' t ~

~

~

~ ~

ates

~

o ~ 1

~-l+P

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ 4

~

~

~ rr e

~

~

~

~

~

~

~

~

~

~

~

~

~

O'C rl

~

~ 1 ~

~ 4 '

~

~ ~ ~

~

~

~

~

~

~

~

~

~

~

~

~

t ~ o

~

bete

~

~

~ted

~ ~

~

~ t ~

~

~ ot ~

~ a

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ oe ~

~ kk ~

kAA ~

'V'l I o"f

~

~

~

~

A ~

~

~

P

~

~

~

~

~

~ t l oo l

~

~

~ t

~

~

~

~

~

~

~

~

~

~ t.

~ e-ar-ette

~

~ ~ ~ t

~

hatt

~ t

~

~

~

~

~

~

~

~

o rr

~ ~ e ~

~o.k-

~

~

~

~

~

~

~

~

e

~ re

~ ~ ~

~ f

~

~

~

~

~

~ ~ ttot

~

~

~

~

~

~

~ o

~

~

~

~

~

~

~

e P.e t.t+

~

~

~

~

~

~ t te

~

~

~

~

~ ~

~

~

~

~

~ ~

~

~

~

~

~

~

stat

~ ~

o Kme-

~

~

~

~

~ PPq tuba]

~

~

~ ~

. ~ P,

~ P

~

~

Me-e

~ t P

~

~

~

~

~

>P

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

+~ ~

~

~ ek

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ t ~

~

~

~

~

~

~

~

~

~

~

~

~

~ k ~

~

~

~

~

~

~ ~ 1'

~ r

~ a,

~

~

~

~

~

~ ~

~

~

tent to

~

~ et

~

ates r\\

o 1r I

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~ ~

~

~

~

~

~

~

~t~r

~

~ ~ o

~

~ 1

'cing

~

~

~

~

~

~

~

~

~

~

~

~

o Wtrl

~

~

~

l*~

~ P4 A ~

~

~

~

~

~ J

~

~r

~

~

~

~

~

~

~

~

~

~

~

~

~ rr 4 ~

~

~

~ kkt

~

~

~

~

"rVl.V-

~ X '

~

~ 41 t

~ ~ t

~

~

~

~

~ 4

~

~

~

~

~

~

~ 4

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

e re

~

~

~

~

~

~

~ <

~ ~

~ P hatt

~

~

~

~

~

~ 4* ~

~

~

~

~

~

~

~

~

~

~

~ ~

~

~

~

~

~

~

~

~

~

~

V'4 < P

~

~

~

~

~

~ k

~ k ~

~

P

~ tt

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

l~o

~ ~

~

~

~

~

~ 4

~

~

~

~

rl"rh'

~

~ k

~ 4

~

~

P

~ ~ ~

,,Pt t

~

~

~

~

~

~

~

'l+V+'f'\\4

~

o

~ 1

~

~

~ k t

~ litt

~

~

~

~

~

o ~

o

~

~

~

~

~

ro-t.r ates F 1 '

~ 1

~ r o

~

~ t

~

l ro

~ ~ ~

~

~

~

~

~

~ ~

o

~

W'l

~ r

~

~

~

~

~

e ~

~

~

~

~

~ '

~

~

'l

~

~

~

~

~

~

~ k ~

r o-W-o

~

~

~

~

~

~

~

~

~

~

~

~

~

o ~

o

~

~

~

~

~

~ ~

~

4

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

A ~

~

~

~

~

~

~

~ l

~

~

~

~

~

~

~

~

~ ~ PP tt

~ 4

~

~

~

~

P-e.P e ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

ates

~ ~

~

~

~

~

~ t

~ 'r

~ l'

~

~

~

~

~

~

~

~

~

~

~

~

~ ~ t

~

~

~

~

~

tent

~

~

~ PE ~

~

~

~

~ PE ~

~

~

~

~

~

~

o ~

V

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

4

~

~

~

~

~ A ~

~

F 4

'+

~ ' '

~

~

~

~ ~ at kk ~

~

~ P

~ ~

~

~

~

~

~

~

~

~

~ to)

~

~

~

~

~

~ ~

o

~

~

~ ~

~

~

~ t P.S-T ~

~

~

~ e

~

~

r

~

~

wrr too ~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

o

~

~

~ 1 '

to

~ 1

~

~

~

~

~

~

~

~

R IV I%ET tHot Leg) - Pr isa'y Face COLQtS Figure 3 s

rrs

ROtc<<

TV<<AN<T<<)

<VER 5 <<)>>>>>>>>>>>> ~<<>>Y AP<'< 1 25'11$

N<51 P<l >>>>>>>>>>>>

>>>>>>>>>>>> Page Plant:

Qutage-G INNA 199!3 Res.

Steam Genevato<':

E<

QUERY: Indications on Tubes De-p lugged in 1998 ROM COL OUTAGE INDICATION VOLTS LOCATION INCHEB 15 16 25 27 i<3 38 Z5

>6 48 49 5!3 51 54 56 61 63 65 66 67 68 72 73 74 75 76 77 79 199!d 199!d 1998 199!3 1998 199!3 1998 199!<!

1998 199!3 199!!

1998 1998 1998 199!d 199!3 1998 1998 199~i!

199!3 199!3 199!3 199!d 1998 199!3 1998 199!3 199!d 1998 1998 1998 1998 199!3 199!3 199<3 1998 1998 1999 1999 199!d 199

199!i>

199!d 199!3 199!3 199<3 1998 1998 1998 1998 1998 1998 a998 1998 1 99'!

1998 1998 199

199<3 199<3 1998 f998 199

199!3 199<3 1998 1998 Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

OD IGA SLEEVED OD IGA SLEEVED OD IGA OD SCC SLEFVED OD IGA QD SCC SLEEVED OD IGA SLEEVED OD SCC QD SCC SLEEVED OD SCC OD SCC SLEEVED QD SCC SLEEVED OD IGA SLEEVED OD lGA SLEEVED OD SCC QD SCC SLEEVED OD SCC OD IGA SLEEVED OD BCC OD SCC SLEEVED OD SCC SLEEVED OD SCC QD SCC SLEEVED OD SCC OD SCC SLEEVED OD SCC OD'CC SLEEVED OD SCC OD SCC SLEE'.VED OD SCC OD SCC SLEEVED OD SCC QD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEE.VED ADI CE-WELD ADI CE-MELD ADI 59 /

T!A CE-NELD ADI TN CE-WELD ADI CE-NELD 69 /

TM 69 /

TN CE-WELD 69 /

TN 55 /

TN CE-WELD 17 TN CE-MELD ADI CE-WELD ADI CE-WELD 72 /

TM 69 /

TN CE-NELD 72 /

TN ADI CE-MELD 45 /

TW 44 /

TN CE-WELD 77 TW CE-NELD 69 /

TN 64 /'W CE-MELD 75 /

TW 59 /

TN CE-WELD 74 TN 76 /

TW CE-WELD 65 /

TM 56 TN CE-NELD 68 T<A 68 /

TN CE-NELD 65 /

TW 72 TN CE-NELD 86 /

TN CE-WELD 94 /

TN CE-MELD 72 /

TN CE-WELD 87 /

TN CE-MELD

/

TN CE-WELD 86 /

TN CE-NELD 94 /

TN CE-WELD 5 ~ 42

6. 47 1 i.96

!i~. 77

7. 66

!d. SB

8. 8<3
2. 84
2. 55

~. 96

1. 58
8. 84
6. 74
6. 45
8. 8!3
8. 62
8. 58 S. 77 g 5Z

<d, 72

2. 11
1. 52
1. 55 8 ~ 75 a.'gz
8. 91
8. 88
8. 9~
1. 18
8. 78
8. 82

!d. 64

1. 16 2, 41
2. 18
3. 53
5. 41
4. 89
1. 81
1. 94 HTS BF HTS PF, HTS SF'TSPF HTB BF HTS SF HTB PF HTS SF HTS SF HTS PF HTS SF HTS PF HTB SF HTS SF HTS PF HTS SF HTS BF HTS PF HTS SF HTS PF HTB SF HTS PF HTB SF HTS PF HTS SF HTS SF HTS PF HTS SF HTS BF HTS PF HTB SF HTS SF HTS PF HTS SF HTB PF HTS SF HTS BF HTS PF HTB SF HTS SF HTB PF HTS SF HTS SF HTS PF HTS SF HTS SF HTS PF HTS SF HTS SF HTS PF HTS SF HTS SF HTB PF HTS SF HTB PF HTS SF HTS PF HTS SF HTS PF HTS SF HTS PF HTS SF HTB PF HTS SF HTB PF HTS SF HTS PF

-15.55

+27.99

-15. 49

+27. <39 16 ~ 62

-18.89

+27'8

-15. o5 1E!. '<!!3

+27.88

-15.94

+. 7. <i!<'!

- f8 ~ jg

16. )9

+27. Si~!

18. '>!3

-17.18

+27.88

-17.49

+27. Q!9

6. 86

+.7. 98 B. 83

+27. 9<d

-17. 14

-11. 91

+27. 88

-15. 87 1>. 96

+27 ~ <3<3

. -16.52

-12.99

+27. 88

-18. 95

+27. 88

-13. 96

-a4: B6

+27

~ 9!3

-16'.62

-18. 45

+27 ~ gg

-18. >2 15, 26

+27.!dg

-16.79

-15

+27. <3<d

-16 ~ 57

-17.41

+.7. 99

-16. 51

-18. 74

+27.88

-16.78

+27.88

-17 ~ ja

+27 ~ 88

-18. 59

+.7

~ 88

-17.!31

+27 ~ gg 18.!i!<3

+27. 88

-17.45

+27'8

-aj. @<3

+27.!3!d Table 6 (Cont'd)

Page 53 of 69

l

RQLC TuQ4H(TH)

(VCR. 5.a)>>>>>>>>>>>>

Honday A>>r !l 2Jr 100N O>>IOS PH >>>>>>>>>>>>

>>>>>>>>>>>> Page P lan t:

G1NNA Outage:

i998 Res.

l QUERY-Indications on Tubes De-plugged in i99!3 Steam Gener ator.-

B RQW COL OUTAGE INDICATION VALUE VOLTS LUCATIQN INCHES 2

8!d i998 Res.

OD SCC i998 Res.

QD SCC i998 Res.

SLEEVED 96 TW 88 I TW CE-WELD

2. 38 HTS SF 4..6 HTS SF HTS PF

-17.28

-iB.27

27. 88 TOTAL TUBES FOUND 28 TOTAL INDICATIONS FOUND

=

78 TOTAL TUBES IN INPUT FILE

=-

. 8 TOTAL TUBES INSPECTED

=

28 Table 6 (Cont'd)

Page 54 of 69

I I

RO<K Tl<<<AN<T<<)

<VCR' I)stsooo

<<on<<ay ap~i I 2Ji

<9%5 sasoss Pa'JJe Plant:

Outage:

GINNA199!d Res.

Steam Genevatav:

8 QUERY: Repaivab le Indicat ic<ns RON COL OUTAGE INDICATION VALUE VOLTS LOCATION INCHES 17 17 17 17 1,6 17 3<3 16 7

ll li 1=.

15 16 17 fS 19 19 2i3 28 21 22 26 26 26 27

~9 1998 199!3 1998 199!d 1998 1998 199<8 199!3 1998 1998 1998 1998 199!d 199<3 199!3 1998 1998 199!d 199<if 199!3 1998 1998 1998 1998 1998 199!d 1998 199!d 1998 1998 1998 1998 199<3 1998 1998 1998 1998 1998 1998 199g 199!3 1998 1998 1998 199!3 199

1998 1998 1998 1998 1998 1998 1998 199<3 1998 1998 1998 1998 1998 199!i>

199!3 1998 1998 1998 199~8 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

TYPE 1

ROLL TRANS SLEEVED TYPE 1

ROLL TRANS SLEEVED OD SCC SLEEVED DISTORT ROLL SLEEVED OD IGA SLEEVED OD WASTAGE OD IGA SLEEVED TYPE 1

ROLL TRANS SLEEVED OD WASTAGE OD IGA SLEEVED OD (senegal)

OD NASTAGE OD IGA SLEEVED DISTORT ROLL SLEEVED ROLL TRANS SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD IGA OD WASTAGE SLEEVED DISTORT ROLL ROLL TRANS OD IGA SLEEVED OD IGA SLEEVED DISTORT ROLL SLEEVED OD IGA SLEEVED OD ISA OD iAASTAGE OD (general)

SLEE'QED QD IGA PLUGGED PLUGGED OD IGA SLEEVED OD IGA SLEEVED QD IGA SLEEVED OD WASTAGE OD IGA OD (general)

OD IGA

~

I SLEEVED OD ISA SLEEVED OD WASTAGE CE-CRV CE-CRV TN CE-WELD CE-CRV ADI CE-CRV 12 /

TW ADI CE-WELD CE-WELD 11 /

TW ADI CE-WELD ADS 18 /

TW ADI CE-WELD CE-NELD CE-WELD ADI CE-CRV ADI CE-WELD ADI 12 /

TN CE-!AELD ADI CE-WELD ADI CE-NELD CE-CRV ADI CE-CRV ADI 14 / TN ADS CE-WELD ADI CE-t'1ECH CE-t'iECH ADI CE-NELD ADI CE-WELD "ADI CE-WELD 2!3

% TN ADI ADS ADI CE-WELD ADI CE-WELD 12 /

TN

1. 73

!d. 8<3

2. 84
1. S4
8. 68
3. 96 5 fu
2. 67

~.89

1. 23 8.8

~

5 ~ 76

1. 67 1

~.74

!3. 47 1 ~

~ 9

8. 49

-. 58

1. 6!d
l. a>
l. 1!3
2. 74 1;!36 8 ~ 3/
1. 75
3. 18
1. 47
6. 88
1. 88
2. B3 2, 43 2 ~ 45
1. 78
11. 94 2 ~ 86
1. 46
8. 51 5 ~ 89
7. 76 HTS HTS HTB HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS MTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS CTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS SF PF PF SF PF PF SF PF SF PF SF PF SF SF PF SF PF PF SF SF PF SF SF PF PF SF F'F PF F'F SF PF SF PF SF SF F'F SF PF PF PF SF PF SF PF SF PF SF SF SF PF SF PF PF SF PF SF PF SF PF SF SF SF PF PF SF PF

-1&. 28

+

~.48

+2 i'. 88

-19.38

+ 2.85

+27. 88

-18 ~ 58

+27 ~ <3!ii 19 4"

+27.88 f7 ~ +8

+27. iag

+ l. 1!d

')<jj

+27. 8III

-2!3.!d<3

+ 2.96

+27.!d<J>

+ 1.28

-16.88

+27.!d8

-15.88

+

1. 2<8

+ 5.94

+27.!dg

-19.58

+27.!i!8

+ 3 ~ 83

+27 ~ gg

-14. 78

+27. 8!d

-f5. 8<3

+27.!M

-1 8 ~ 8<d

~ 8 ~ 6<3

+27. <dg

19. 68

+ 2.98

+ 4.57

+27 ~ <ijv(f

-16

~ 5<3

~27. ~i!8

-28.!d!3

~27. 9!3 f Q ~ 8<3

+.7. 88 1 2 ~ 2<d

+

1.H!3

-1 1. 48

+27 F 88

-17.48

-17. 88

+27.88

-17. '28

+27 ~ igg

-18. 4!3

+

~ 7 88

-17. 88

-17. 48

+ 4.88

+27. gg

-1 3. 6<3

+27. 8<3

+ 1.58 Table 6 (Cont'd)

Page 55 of 69

<<<<LC T<<<N<<< T<<<

<V<LR 5, 0 < osooeo Honday Atr < <

25,

<0<<<<<

OleO!

P<< esesoo

~St%00 1 age Plant:'utage:

G INNA 199!d Res.

Steam Generator:

B QUERY: Repair able Indications RON COL 'OUTAGE INDICATION VALUE VOLTS LQ( ATIUN INCHFS 41 17 38

~8 32 32 Z4

~>5 35

.>6 Zj Z8 38 49 1998 199!d 199<3 199!3 1998 199!d 1998 1998 1998 199<3 1998 199id 199<ij 1998 199!ij 1 99<3 1 99!d 199!d 199!d 1998 1998 199!ij 1998 199!d 1998 1999 1998 199!3 199!d 199<3 1 99!3 1998 1998 199!d 199<3 199<3 199~d 199!d 1998 1 99!3 1 99!3 1998 1998 1 99!3 1998 1998 199g 1998 1998 1998 1998 1998 1998 1998 1998 199@

1998 1998 1 99<3 48 199!3 41 199<ij 1998 1998 19 /!8 199!ij 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res; Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

QD (gener al )

OD ISA SLEEVED DISTORT ROLL PLUGGED PLUGGED GD WASTAGE OD WASTAGE OD IGA SLEEVED OD WASTAGE OD WASTAGE OD IGA SLEEVED OD WASTAGE OD WASTAGE OD WASTAGE OD IGA SLEEVED OD "WASTAGE QD WASTAGE OD WASTAGE OD (gener al )

OD IGA PLUGGED PLUGGED QD WASTAGE GD IGA SLEE VED OD WASTAGE DISTORT ROLL SLEEVED QD WASTAGE OD SCC DISTORT ROLL OD IGA ROLL TRANS SLEEVED OD, (qeneral)

OD IGA SLEEVED QD IGA SLEEVED OD IBA SLEEVED OD WASTAGE OD IGA SLEEVED OD WASTAGE OD SCC SLEEVED OD (general)

OD (gener al)

PLUGGED PLUGGED OD IGA SLEEVED OD IGA SLEEVED OD SCC SLEEVED QD WASTAGE OD IGA SLEEVED OD IGA DISTORT ROLL SLEEVED ADB ADI

'CE-WELD CE-NECH CE-1'1ECH 2 /

TW 1Z TW ADI CE-MELD 17 /

TW 19 '/

TW ADI CE-NELD 4 /

TN 18 TW 18 /

TN ADI CE-NELD il /

TN 2 /

TN 6 /

TN ADB ADI CE-NECH CE-NECH 11 TN ADI CE-WELD 6 /

TN CE-MELD 14

% TN 81 TW ADI CE-MELD ADS ADI CE-WELD ADI CE-CRV ADI CE-WELD 22 /

TW ADI CE-NFLD 14 TN 82 /

TN CE-NELD

=!d /

TW Zg /

TN CE NLD S CE-NECH ADI CE-CRV ADI CE-CRV

.96 /

TN CE-CRV 18 /

TW ADI CE-MELD ADI CE-WELD 1,g, 52

1. 4v
2. 45
8. 87
2. 42
1. >5
5. 19
5. /8 2 ~ !82
8. 58
i. 15
4. 94
g. 84
2. V9
8. 5>
5. 87

!ij. 5 1 1. 82

7. 58
l. 59
2. 15

~~ ~ i>S

3. 99
3. 85 1. 69
8. 75
a. 88
4. 49
5. 82
4. 79
2. 18 i4 1.!ij8
4. 84
2. 82
3. 81
4. 26
1. 72
8. 91
5. a<3
4. 61

~~. 38 HTS HTS HTS HTS HTB CTS HTS HTS HTB HTS HTB HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTB CTS HTS HTS HTB HTS HTB HTS HTB HTS HTS HTS HTB HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS CTB HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTB BF PF PF SF PF F'F SF SF SF PF SF SF SF F'F SF.

SF SF SF PF SF SF SF SF PF PF PF SF SF PF SF SF PF SF SF BF PF PF PF SF SF PF SF PF SF PF SF BF PF SF SF PF PF PF PF PF SF PF SF PF SF PF SF BF PF BF SF

-16.68

+ 5.56

+27. 8~<j

19. 6!3

+

1. 7!3

+ !ij. 8!3 5 ~ 2!ij

~27 ~ c(jg

+ 8. 8<3

+ 1.18

-15.18

+27, gg

+ =. 6!3

+ 1.18

+ 8. 8!d-1 8 ~ 2<d

+27.!38

+ 2.58

+ 1.98

+ 8.8!3

-17. 68

+ 2 ~ "<<6

+ 8.S8

-15.58 7 ~ <38 1

!3

-19. 8<3

+27 ~ 88

+

1

~ B!8

-16. 9!d 7g

+ 4.13

++27.88

-14.78

-15.""9

+27. <3$

-17. 9!ij

+.7. 88

- 15.!d<ij

+27.88

+

1.4<ij

-17. 4!3

+27, gg

+

1 5<d

8. 4<ij

~27. 88

+ 7.'~1

+ 6.89

-17. 8j(l

+27.88

-18.68

+27 ~ !(jg

-18. 7!d

+.7. 8!J

+ g

+<d

-15. 5!d

+27. 8<(j

-15

~ 2<3

-29.99

+27.88 Table 6 (Cont'd)

Page 56 of 69

<<<<< C TUQA<<<T<< <

<VCR s.e>o~oa<<<<<<only

<<< r<1 2J,

<P9e

<<i< <<<

P<< sass>>o

~ioooo Pa8e Plant-Outage'-

GINNA1998 Res.

Steam Generator:

B RQW CQL OUTAGE QUERY: Repairable Indications INDICATION VALUE VOLTS LOCATION INCHES 41 44.

41 7

42 8

42 14 42 "31 42 41 42 7

43 8

43 1!d 43 35 43 41 43 42 35 44 38 44 48 44 45 23 45 26 45 41 45 46 46 199!i!

1998 1998 1998 199!i!

1 99!iI 199<3 199<3 1 99~d 1998 199(I 199<3 1998 1998 1998 1998 1998 199<3 1998 199<3 199<3 199!d 1998 1998 1998 1998 1998 199<3 1996!

199!d 199<3 1998 1998 1998 1998 1998 1998 1998 19'98 1998 1998 1998 1998 199<3 1998 199!3 1998 1998 1998 1998 1998 1998 1998 1998 1999 199<3 1998 1998 199!d 199<3 199!d 1998 1998 1998 1998 1998 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

OD WASTAGE OD (genera OD IGA SLEEVED OD SCC

'PLUGGED PLUGGED OD WASTAGE OD I GA OD IGA OD WASTAGE SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD WASTAGE OD IGA SLEEVED OD IBA SLEEVED OD WASTAGE DISTORT ROLL SLEEVED QD IGA OD IBA SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC PLUGGED PLUGGED OD WASTAGE OD WASTAGE OD IGA SLEEVED OD WASTAGE OD

<AASTAGE OD WASTAGE QD WASTAGE OD WASTAGE QD SCC SLEEVED TYPE 1

ROLL TRANS SLEEVED OD WASTAGE QD (genera OD IGA SLEEVED OD WASTAGE TYPE 1

ROLL TRANS OD (gener al )

QD IGA SLEEVED TYPE 1

ROLL TRANS SLEI..VED OD IGA SLEEVED 19 TN ADS ADI CE-MELD 93 /

TM CE-NECH, CE-MECH 12 TN ADI ADI 1 /

TN CE-WELD ADI CE-NELD AD1 CE-MELD ADI CE-NELD AD1

, CE-CRV 19/TN ADI CE-NELD ADI CE-WELD 7%

TN CE-<AELD ADI ADI CE-CRV 77

% TN CE-CRV 94 /

TN CE-CRV ADS ADI CE-CRV CE-CRV ADI CE-CRV 22 TW CE-NECH CE-NECH 7 /

TN 17 /

TN ADI CE-WELD 3 /

TW

/

TN 15 /

TM 13 /

TN 38 / TN 58 TN CE-NELD CE-CRV 28 /

TN ADS ADI CE-<AELD

7 /

TN

7. 75
3. 24 1 ~ 26
2. 64
3. 74
7. 35 50 22

=. 86

4. 71
3. 98
5. 85
4. "7 2 ~ 43 6.!d 1
4. 83
2. 94
3. 26
3. 43
8. 73 1

~ 93

l. 81 3 ~ 58

!i>. 37

4. 49
1. 85
2. 68 8 ~ 63 8 ~ 91

~. "<<8

2. 81
i. 14

~.61

1. 82

!<!>. 99 8 ~ 52 3 ~ 32

2. 18
1. 83 1

~ 99

8. 34
1. 59
4. 1<3
i. 38 HTB HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTB CTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS PF SF PF SF PF PF SF PF PF SF PF SF PF PF SF SF BF PF SF SF SF SF SF SF PF SF PF PF BF SF PF PF BF SF PF HTB SF HTS SF HTS PF HTS PF HTS SF HTS PF CTS PF HTS SF HTS BF HTS SF CTB SF HTS PF HTS SF HTS PF HTB SF HTS PF HTB SF HTS PF HTS SF HTS PF HTS SF HTS SF HTB PF HTS SF HTB PF HTS SF HTB SF HTS PF HTB SF HTS PF HTS PF HTS SF

+ 1. /8

3. 98

+18.55

+27. 8!<'.>

-18. 7<3

<jj, 48

-16. 8<d

-15.!i~!d

+ l. 8<3

+27. 88 15 5!d

+27.88 5.88

+.7. <d<3 18 38

+ 7.!d8 1 b. 2<3

+27. <3!d

+ 8.88

-16.!d8

+ 7.88

-14. 3<3

+27.88

+ 8.78 19.48 27 88

-17.48

+ 4.26

+27. <38

-18. 2<3

+27. 88

-1 t). 8<3 7

<i!8

-17. 5<3

+ 3.62

+27. <38

-11 28

+ 1.74

+27 ~ 88

-17. 3<3

+27 ~ 88

-17 ~ 98

+ 1.58

+ 8.58

16. 88

+.7.!i!8

+ 2.48

+ 2. 3<3

+ 1.78

+ 1.48

+ 1.88

-17.e8

+27.88

-19.18

+ 2'5

+27.<38

+ 8. 7<3

-15. 1!d

+ 6.5'/

+27. 8<3

+

1. 7<3

19. 3!d 2 ~ 36 Table 6 (Cont'd)

Page 57 of 69

S

ssssss

<<<<LC T<<<44<<<TH)

<VLR 5.!<>ssssss

<<ondsy

<Ss<

QJ,

<<<9e Oi< 01 P<< ssssss ssssss Page Plan t:

G INNA Outage:

1998 Res.

~

~

~

QUERY: Repairable Indicat ians RQN CQL INDICATI QN VALUE VOLTS LUCATIQhl INCHES Steam Generator:

B 32 48 48 17 Q3 38 46 46 47 47 47 47 48 48 49 49 49 49 58 5g 58 58 5!ij 58 58 51 51 52 52 52 52 199!3 199!d 1 9'?!d 199!d 199!3 199!ij 1'?98 1998 1998 1998 1998 199!3 199<3 1998 1998 1998 1998 199!3 199<ij 1998 199<ij 199!d 1998 1 99<ij 1998 199!3 1998 1998 1998 199sj 199<3 199!3 1998 1998 1998 199<3 1998 199!<.j 1998 1998 1998 1998 199<ij 199!3 1998 199!3 1998 1998 1998 1998 1998 1998 1998 1998 1998 1 99!d 1998 199!d 1998 199<3 199!3 1998 1998 199! j 199!3 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

SLEEVED OD IGA

SLEEVED, OD IGA SLEEVED OD WASTAGE SLEEVED OD IGA SLEEVED QD WASTAGE OD SCC SLEEVED TYF'E 1

OD IGA ROLL TRANS SLEEVED OD IGA OD WASTAGE SLEEVED OD SCC SLEF:.VED QD IGA SLEFVED OD SCC SLEEVED OD SCC SLEEVED OD IGA SLEEVED OD IGA PLUGGED PLUGGED OD IGA SLEEVED OD IGA SLEEVED OD BCC SLEEVED OD IGA OD WASTAGE SLEEVED OD WASTAGE OD SCC SLEEVED OD WASTAGE OD SCC SLEEVED QD WASTAGE OD SCC SLEEVED OD SCC SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD WASTAGE OD IGA PLUGGED PLUGGED OD WASTAGE QD SCC PLUGGED PLUGGED TYPE 1

ROLL TRANS SLEEVED CE-MELD

ADI, CE-WELD ADI CE-CRV 41 /

TW CE-MELD ADI CE-MELD 15 /

TN 75 / TN.

CE-MELD ADI CE-CRV ADI1%

TW CE-MELD 84 TW CE-CRV ADI CE-CRV 54 /

TN CE-CRV 41 /

TN CE-CRV ADI CE-CRV ADI CE-MECH CE-MECH ADI CE-MELD ADI CE-WFLD 63 /

TW CE-WELD ADI2 /

TN CE-WELD 13%

TW 82 TW CE-WELD 17/

TN

/

TN CE-WELD 11 /

TW 89 /

TW CE-WELD 87 /

TN CE-CRV ADI CE-NELD ADI CE-NELD 18 /

TW ADI CE-MECH CE-MECH 26 TM 8

~ /

TM CE-MECH CE-MECH

3. 37
3. 82
8. 77
8. 14
3. 82

!d, B3

3. 66
7. 34
8. 96
4. 16
3. 84 2 ~ 23
8. 31
8. 48
9. 95
4. 67
4. E!5 2 ~ 42 1

~ 16

1. 76
2. 53

<d. 89

8. 38
8. 54
4. 5<3

!iS. 56

!ij.78

3. 84
2. 88
1. 86 4 ~ 72 1.,28

!3. 75 3s 31

8. 75 HTB HTS HTS HTS HTS HTS HTB HTS HTS HTS HTB HTS HTS HTS HTS HTS HTS CTS HTS HTS HTB HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS CTS HTS HTS HTB HTS HTS HTS HTS CTS HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS CTS HTS HTS HTS CTS HTS HTS HTS PF SF PF SF PF SF PF SF PF SF SF PF SF SF PF PF SF SF PF SF PF SF PF SF PF SF F'F SF PF SF PF PF BF PF BF PF SF PF SF SF F'F SF SF PF SF SF PF SF SF PF SF PF SF PF SF PF SF SF P.F F'F SF SF PF PF SF PF PF

+27. 8!d

-17. 4<d

+27 ~ 8</

-16. 88

+.7

~ 88

+ 8.6<3 y27 ~ <dg

-15 ~ 2<d

+27. 88

+ !d.65

-18. 26

+27 F 88 19.32

-17.53

+ 2 ~ 55

~27

~ gg

-17. 25

+

1 ~ 5!d

+27, grd

-18. 67

+27 88

-17 ~ 1 rd

+27.!d<ij

-17.13

+27.88

-18. 47

+27. 88

-17. 19

+.7. 88

-17.88 15 dg

+27. I<j8

-16. <3<8

+27. 8!3

-18. 48

+27. 88 V. 68

+ 1.38

~%7 ~ <d!jj

+ 1.71

- 1 Ej. 6!d

~27. 8!ij

+

<3. Ej8

-18. 14

+27

~ 88

+ 8.57

- 1 Ej. 67

+27. <38 1Ej. 57

+27 ~ gg

-16. 89

+27.!d<ij

-17

~ 88

+27 ~ <dg 4 ~ 67

5. 23

+ 2 ~ 6<<

-18 ~ -7 19 ~ 2<3

+ 2.8!d

+27. 88 Table 6 (Cont'd)

Page 58 of 69

<<<<<<<<<<<<ROLC TUQ<M<<T<<)

<VCR

~ <<

5 0) <<<<<<<<<<<<Non<<<<y 4p<~! l 2Je

<OIL<

O<<<02

<<<<<<<<<<<< Page Plant:

Outage:

G II'INA1998 Res.

Steam Generator:

B RON COL OUTAGE QUERY: Repairable Indicat ions INDICATION VALUE VOLTS LOCATION INCHES-28 53 54 1

55 5

55 16 55 55 1

56 17 56 18 56 57 15 57 57 31 S7 57 57 57 48 57 1998 1998 1998 199rd 199!ij 199<3 1998 1998 1998 199iij 199~j 199!3 1998 1998 199zj 1998 1998 199<3 199!d 199<3 1998 1998 1 99<3 1998 1998 1998 199!3 1998 1998 1998 1998 1998 1998 1998 1998 199!3 1998 1998 199!d 199!d 199<ij 1998 1998 199!3 1998 1998 1998 1998 1998 1998 1998 1998 199g 199!3 1998 1998 1998 1998 1998 1998 199!ij 199<3 1998 199<~j 1998 199!d 199!3 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res; Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

OD WASTAGE OD <senegal>

OD IGA SLEEVED OD IGA SLEEVED OD IGA PLUGGED PLUGGED OD SCC SLEEVED OD IGA SLEEVED QD NASTAGE OD IGA QD

<AASTAGE SLEFVED OD I GA QD WASTAGE

PLUGGED, PLUGGED OD SCC PLUGGED PLUGGED OD WASTAGE TYPE 1

ROLL TRANS SLEEVED OD WASTAGE OD (generall OD IGA SLEEVED OD I GA SLEEVED OD IGA SLEEVED OD WASTAGE TYPE 1

ROLL TRANS OD WASTAGE OD WASTAGE SLEEVED OD WASTAGE TYPE 1

ROLL TRANS SLEEVED OD WASTAGE OD WASTAGE OD SCC'DeCC SLFEVED OD WASTAGE OD WABTAGE OD SCC OD SCf'LEEVED OD WASTAGE QD SCC SLEEVED OD BCC PLUGGED PLUGGED OD SCC TYPE 1

OD IGA SLEEVED OD SCC 4 /

TM ADS ADI CE-MELD ADI CE-WELD ADI CE-NECH CE-NECH 48 TW CE-MELD ADI CE-WELD 13 TN ADI6%

TN CE-MELD ADI12/

TN CE-IIECH

'CE-MECH 74

% TN CE-NECH

.CE-NECH 5 /

TM CE-NELD 15 /

TN ADS ADI CE-WELD ADI CE-WELD ADI CE-WELD 4%

TM 11 TW

/

TW CE-NELD 5 /

TW CE-WELD 4 /

TN 21 TN 71 /

TN 79 /

T!A CE-NELD 15 /

TW 16 /

TW 79 /

TN 69 /

TW CE-WELD 7 /

TM 84 /

TN CE-WELD 79 /

TN CE-MECH CE-I'1ECH 49 /

TW ADI CE-CRV 34 / TN

, 2 ~

5 ~ 27 g ~ 56 3 ~ &!3

9. 51
8. 31 2, 1<3

=.66

2. 96
3. 71
3. 76
5. 29
8. 95
1. 76
1. 93
8. 55 3 ~ 28j

? ~ 53

8. 44 3.

~ 4

4. 88
2. 88
4. 28
2. 24
2. 81 3 ~ 13

, 1.79

4. 75
1. 59
1. 79
1. 58
8. 44

<3. 59

2. 81 8 ~ 69

!3. 36

2. 96 jd. 62
8. 31

!3. 95

5. Sg 1

~ 33 8.68 HTS BF HTS SF HTS PF HTS PF HTS BF HTS PF HTS BF HTS PF CTB PF HTS SF HTB PF HTS SF HTB PF HTS SF HTS BF CTS SF HTB PF HTS SF HTB BF HTS PF CTB PF HTS SF HTB PF CTS PF HTS SF HTS BF HTS PF HTS PF HTS SF HTS SF HTS PF HTS PF HTB BF HTS PF HTB BF HTS PF HTS SF HTS SF HTB PF CTS SF CTS SF HTS PF HTS BF HTS SF KTS PF HTS PF HTS SF HTS SF HTS SF HTB SF HTS PF HTS SF HTB SF HTS SF HTB BF HTS~ PF HTS BF HTS SF HTB PF HTS SF HTS PF CTS PF HTS SF HTS SF HTB PF HTS PF HTS SF

+ 2.'/8

-15. 75

+ 5.15

+27. <3!3

-17.88

+27. 8!d

-17.88

-14.68,

+.7.!dg 1 2 r<jg

+27 grd

+

1

~ 57

-16.88

+ 1.68

+27'8

-18.68 2 ~ 42

-17'8

+ 2.19

-18.88 2 ~ 27

+27. 88 2 ~ 29

4. 34

+ 5 ~ 21

+27. 8<3 1 5 ~ 8!d

+27. 88

-17.!dg

+27.88

+ 8.79

-18.83

+ 2.79

+ 1.63

+ 1. 5!ij

+27. 88

+ 2.41

-19. 18

+ 2.91

+27. 88

+ 1.65

+ 1.68 17.gg

-18.48

+27.88

+ 1.58

+ 8 ~ '/6

-14. 82

-17. 68

+27. <dg

+ 8 ~ 7/

-14.59

+27 egg

-17. 48

-1Ej. 43

-19. 34

+ 3.38

+27 ~ 88

-1Ej. 18 Table 6 (Cont<d)

Page 59 of 69

l

oseees R<<L<>>

TU<<A<<<TH<

<V<>>R. 0 0>oooo>>>>o H>>>>>>>>dog A<>>>>'< <

<<4>>

<>><>><0 04>>02

<>>H eooeoe IOItlI Pa 'Je Plant:

OUtage>>

G INNA19'?8 Res.

Steam Generator:

B QUERY:

Repa irab le indications RQM CQL OUTAGE INDICATION VALUE VOLTS LQCATIUN INCHEB n

17 27 58 58 58 58 59 59 59 59 6!3 6!3 68 6<3 68 68 62 62 62 63 63 63 63 1998 1?99 19+@

199!d 199!3 199!d 1998 199<3 199!3 199!d 1998 1998 199!d 199<d 1998 199<3 1'? 9!d 199!3 1,'?9<3 199<3 199!3 1 99i3 1'?99 1998 1998 1999 1998 1998 1998 1998 1998 199'>

199!3 1998 1998 1998 199<3 1998 19'?8 1999 1998 199!d 199!3 1998 1998 1998 1998 1998 1998 1998 1998 1998 1 99ig 1998 1 99~d 199!d 19'? 8 1998 199

199!3 199~~!

199!d 199!3 1998 1'? 9!3 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

SLEE VED OD IGA SLEEVED OD IGA SLEEVED OD SCC SLEEVED OD WASTAGE OD WASTAGE OD SCC OD SCC SLEEVED QD IBA SLEEVED OD SCC SLEEVED OD SCC SLEEVED QD WASTAGE OD IGA SLEEVED OD SCC SLEEVED OD SCC SLEFVED OD IGA SLEEVED OD ISA OD WASTAGE SLEEVED OD IGA.

SLEEVED QD WABTASE QD SCC TYPE 1

OD IGA ROLL TRANS SLEEVED OD IGA SLEEVED OD WASTAGE OD IGA SLEEVED OD ISA OD WASTAGE SLEEVED OD NASTAGE OD SCC OD WASTAGE OD SCC SLEEVED OD IBA OD WASTAGE OD IGA SLEEVED OD IGA PLUGGED PLUGGED=

OD WASTAGE OD ISA SLEEVED QD iAASTASE OD SCC SLEEVED QD ISA OD iAASTAGE SLEEVED CE-('RV ADI CE-MELD ADI CE-NELD 69 /

TN CE-MELD 7 /

TW

/

TN d6 /

TW 92

% TN CE-MELD ADI CE-iAFLD 82 /

TW CE-WFLD 42 /

TW CE-NFLD 11 /

TN ADI CE-MELD 86 /

TN CE-WELD 26 TN CE-WELD ADI CE-WELD ADI /

TW CE-<AELD ADI CE-MFLD 13 TW 37 /

TN ADI CE-<AELD ADI CE-MFLD 7%

TN ADI CE-WELD ADI4 /

TW CE-MELD 6/

TM 8!3 /

TW 8/TW 91 /

TW CE-WELD ADI 16 /

TN ADI CE-WELD ADI CE-NECH CE-NECH 2 /

TN ADI CE-WELD 11 /

TW 43 TM CE-NELD ADI 19 /

TW CE-WELD 3 ~ 97

<3. 4.1

9. 76 2 ~ g5
9. 57
1. 82
5. 67
8. 67 g, 42
4. 47
7. 74
8. 42

!3. 37

1. 93 2 ~ 25 2 ~ 96 4 ~ 44 1

~ 38

<3 ~ 72

3. 82
9. 61 1. 67
4. 85
5. 34
5. 21
5. 24
9. 52
4. 66 8 ~ 64
3. 95 1

~ 66

6. 3!d
4. 98
2. 63
6. 68
4. 83

!d. 27

1. 88
6. 63 HTS PF HTS SF HTB PF HTS SF HTB PF HTS SF HTB PF HTe SF HTB SF HTS SF HTS BF HTS PF HTS SF HTS PF HTS SF HTS PF HTS SF HTS PF HTS SF HTS SF HTB PF HTS SF HTB PF HTS SF HTB PF HTS SF HTS PF HTS SF CTS SF HTS PF HTS BF HTS PF HTB SF HTS SF HTB BF HTS PF HTB PF HTS PF HTS BF HTS PF HTB SF HTS SF HTB PF HTS SF HTB SF HTS PF HTB SF HTS SF HTB SF HTS SF HTB PF HTS SF HTS SF HTS SF HTS PF HTS SF HTS PF CTS PF HTS SF HTS SF HTB PF HTS SF HTS SF HTS PF HTS BF HTS SF HTB PF

+27. 88

-14. 19

+27.

88'16.25

+27.88

-15. 43

+2'j. g!8

+ 1.69

8. 59 17.!d4

-18.13

~27.!j~i!

-14. !38

+27. 9<3 2!3

+27 ~ !J>><3 2g

+27 ~ 89

+ 2'7 5 F 99

+27.88

-17. 5!d

+27. 88

16. 5!3

+27 gg

-16.78

+27.8I<)

-17.89

+ 1.71

+ 7.98 16.!i>g

~27, <3!d

+

1

~ 44

-17. 93

-1 /. 1 i

+

4 ~ '-'8

+ 2.5/

+27 ~ <0<<9

-14. 6<3

+27. 99

1. 48

-16.!38

+27. <<lg 12>> 3i3

+ 1.58

+

~ 7. 88

+ 1. 5!3

-11. 98

+ 1.'48

-13 ~ 17

+.7

~ 88

4. 49

+ 1. 6!3 4 ~ 4 id

+27. 88

-16. 5<3

+

1

~ 4~i>

-15. 39

+27. 99

+ 1.3!d

-18. 55

+.7. <i<9.

-14.

1

+ 1.39

+27. 88 L'able 6 (Cont'd)

Page 60 of 69

ls

~>>>>>>>>>>

R<<dg T<J<<AN<T<<)

<VLR 5,0<>>>>>>>>>>>>

<<an<<>>Y A<Ir<l M~

<OOO 0>><C<2 Pt1 >>>>>>>>>>>>

j a8e Plant:

Outage:

6 INNA1998 Res.

Steam Genevatov-B QUERY: Repair able Indications ROM COL OUTAGE INDICATION VALUE VOLTB LOCATION INCHES 24

'I7 2g 64 64 64 64 64 64 66 66 1998 1998 199!3 1998 1998 1998 199~<.j 1993 1998 1998 1998 199<3 1998 199!3 1998 1998 1 99!ij 1 99!ij 199!d 1998 19'/!d 199!8 199!ij 1998 67 67 68 78 7!d 71 71 7~~

74 74 75 75 75 75 76 1993<

'99!d 199!d 199!3 199Iij 1998 1998 1998 1998 1998 1998 1 99<3 1998 1998 1998 1998 1 99!3 199!d 1998 199!3 1998 1998 199<3 1998 1 99!3 1998 1998 1998 1998 1998 1 99!<'.j 199!3 199!ij 1999 1998 1999 1998 1998 1998 1998 1998

=1998 67 1998 Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

ResI Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

OD IGA SLEEVED OD IGA SLEEVED OD WASTAGE QD IGA SLEEVED OD WASTAGE OD IGA SLEEVED OD WASTAGE QD IGA SLEEVED OD

<AASTAGE OD IGA SLEEVED QD SCC PLUGGED PLUGGED OD

<AASTAGE OD IGA SLEEVED OD WASTAGE QD IGA SLEE VED OD WASTAGE OD SCC OD SCC SLEEVED OD

<AASTAGE OD BCC SLEEVED OD (geneval>

DS OD

(<<jeneva 1 )

OTHER OD (8eneval)

OD'general>

PLUGGED PLUGGED QD IGA SLEEVED OD SCC SLEEVED QD BCC SLEEVED OD SCC SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD IGA PLUGGED PLUGGED OD IGA SLEFVED OD IGA SLEEVED DISTORT ROLL SLEEVED OD IGA SLEEVED QD SCC PLUGGED PLUGGED

"'D IGA ADI CE-WELD ADI CE-MELD 6%TM ADI CE-WELD 19 /

TN ADI CE-WELD 22 /

TW ADI CE-WELD 16 /

TW DI E-<AELD 68 /

TN CE-MECH CE-MECH 7 /

TN ADI CE-WELD

/

TW ADI CE-WELD

1 /

TN 73 /

TW

/

TN CE-MELD 11 /

TW 83 /

TW CE-NELD 28 TN 27 /

TM 27 /

TW 28 /

TN CE-MECH CE-MECH ADI CE-MELD 85 /

TN CE-MELD 78 TN CE-CRV 76 /

TM CE-NFLD ADI CE-WELD ADI CE-MELD ADI CE-MECH CE-MECH ADI CE-NELD ADI CE-WELD CE-CRV ADI CE-('RV 98 /

TN CE-MECH CE-MECH ADI

1. 65
1. 72 18
8. 98
1. 5'/
8. 88 4 8r
6. 33
i. 78 2 ~ <32
i. 19
1. 94
2. 56
3. 77 2..><3
1. 63 8 ~ 52
1. 46

!d. 47

1. 51
1. 42
2. 38
8. 87
1. ~~6
6. 47
1. 75

~.76

2. 55 4 ~ 58
6. 84 5.

7 2 ~ ~2 4 ~ 77

2. 18 4 ~ 58 HTS HTS HTB HTS HTS HTS HTS HTS HTS HTS HTB HTS HTS HTS CTS HTS HTB HTS HTB HTS HTS HTS HTB HTS HTB CTS HTS SF PF SF PF SF PF SF PF SF PF SF PF SF PF PF SF PF SF PF SF PF SF F'F SF PF BF HTS BF HTS PF HTS BF HTS PF HTS SF HTS SF HTB PF HTS SF HTB BF HTS PF HTB SF HTS bF HTB PF HTS SF HTS BF.

HTS PF HTS BF HTS 'PF CTB PF HTS SF HTS BF HTS PF HTS SF HTS SF HTB PF HTS SF HTB BF HTS SF HTB PF HTs SF HTB SF HTS CZ C2 Ci C2 C3 C:5 HTS CTS

-1

~. 28

+27.!ijg

15. 1<3
27. gg

+ 8.48

-ld. 79

+27. <39

i. 59

-11.34

+27.!3<j

+ 1.YS

-18. 49

+27. 8!3

+

1.8<3

-17.76

+27. 9!d 18.

1<3

+ 8.48

-16. ikj

+27 ~ 98

+ 1.28

-16. 88

+27. <38

+ 8.8<3

-16. 2!<'.j

-17. 88

+27.8$

+ 8.79

6. 58

+27. 89

8. <3Z

-17.48

+27.98

-17.88

+27.!ij!3 1Ej. 6!ij

+27, <jjg

-16.18

+27 ~ <3!d

-16.48

+27.!ijId

-17 ~ 88

+.7 ~ 88

-17. ~!ij

-18. >9

+27.!38

-17. 7'ij

+27

~ gg

-19. ~4

+2/

~ 8$

-17.!d!3

+27 ~ 88

19. 1!d

-16. 55 Table 6 (Cont'd)

Page 61 of 69

<<<<L<

TU<<<<<<<TN>

<VO 5

<<) <<>>>>>>>>>>

<<On<<<<y Air < <

2Je 1090 O>><02 P<< >>>>>>>><<>>

>>>>>>>>>>>> Page Plant:

GINNA Outage:

1998 Res.

QUERY: Repairable Indicat ions Steam Generator:

B ROW COL OUTAGE INDICATION VALUE VOLTB LOCATION INCHES 8

76 18 76 17 76 3

77 5

77 16 77 18 77 6

78 7

78 28 7EI B<3 15 8!d 5

81 7

8

~

4 83 24 83 18 84 8

85 11 85 14 EI6 15 S6 1998 199<3 199!d 199<3 199$

199!3 1998 1'? 98 1998 1'?98 1'? 9!3 19'?8 1'? 9!3 199<3 f99!d 1998 199!d 1998 1'? 9!3 1 99!3 1998 1998 199g 199<3 199<3 199!3 199!3 199<3 1998 1 99<d 19'?8 f99!3 1'?98 1998 1998 1998 1998 1 99i3 1?98 1998 199/i 199<3 f 99<8 19'?!3 1998 1998 199!3 1998 1998 199!d 1998 1998 Res.

Res.

Res.

Res.

Res

~

Res.

Res.

Res.

Res.

Res.

R'es.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

Res.

SLEE.VED OD ISA SLEl-'.VED OD WASTAGE OD IGA SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD NASTAGE OD IGA SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD SCC SLEEVED OD NABTAGE OD IGA SLEEVED OD ISA SLEEVED OD IGA SLEEVED OD IGA PLUGGED PLUGGED OD IGA SLEE VED OD IGA SLEE:VED OD WASTAGE OD IGA SLEEVED OD SCC PLUGGED PLUGGED OD SCC SLEFVED OD SCC SLEEVED OD IGA SLEEVED OD IGA SLEEVED OD SCC SLEEVED OD SCC OD SCC SLEEVED CE-WELD ADI CE-WELD 18 TM ADI CE-WELD ADI CE-WELD ADI CE-WELD 6 /

TN ADI CE-WELD 7'? /

TW CE-WELD 97 TN CE-MELD TW CE-CRV 5 /

TN ADI CE-MELD ADI CE-WELD ADI CE-CRV ADI CE-MECH CE-MECH ADI CE-WELD ADI CE-CRV 5 /

TN ADI CE-CRV Ewi /

TW CE-MECH CE-MECH 91

% TN CE-CRV 66 /

TW CE-CRV ADI CE-CRV ADI CE-CRV 89 /

TW CE-CRV 72 /

TW 77 /

TN CE-CRV

4. 17 f.32
3. 11
3. 72 5 ~ 25
2. 68
5. 58

<d. 3

~

f. 17
1. 8<3 2.!d5 5 ~ 6!3
6. 43 5.!d8
5. 27 7 ~ 82
3. 75 1.1

~

5 ~ 5/

ig ~

24

8. 39
8. 84
4. 46
8. 37
2. 17

!d HTB HTS HTB HTS HTB HTS HTS HTS HTS HTS HTS HTS HTB HTS HTB HTS HTB HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS HTS CTS HTS HTB HTS HTS HTS HTB HTS HTS HTS CTB HTS HTS HTS HTB HTS HTS HTS HTB HTS HTB HTS HTS HTS PF SF PF BF BF PF BF PF BF PF SF SF PF SF PF SF PF SF PF SF SF PF BF PF BF PF SF PF PF

'F F'F SF PF SF SF PF SF PF PF SF PF SF PF SF F'F SF PF SF PF SF SF

+27.88

-15.79

+27'8

+

!3. 54

-15.87

+27'8

-17

~ 88

+'>7. 8<d

-16.13

+27 ~ 8<d

+

!iS. 5/

-16. 38

+ 7.8jd

-17. >3

+27 ~ !d<d

-18.8d

+27'g

-18.78

+27. 8!d

+ <3.68

-15.62

~27

~ gg

-18.5/

+27. 8<3

-17. 38

+27.88

-16. 76

-17. 82

+27.88

-16.74

+27

~ 8!d

+ 8.88

16. 3

+27.!d<3

-fE! ~ 78

-18.55

+.7.88

-17.5d

+.7. 88

-18.

<<6

+27 ~ 8!i!

-16. 87

+27.88

-15.98 27

~ 8!

,17.69

-fE!. 29

+27. 8<3 TOTAL TUBES FOUND TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE TOTAL TUBES INSPECTED 183 5-1 183 183 Table 6 (Cont'd)

Page 62 of 69

GINNA STEAN GENERATOR TUBE INSPECTION AHD CORRECTIVE ACTIOH HISTORY DATE NO. TUBES INSPECTED A

8 HOT COLD HOT COLD PRI NARY TO SECONDARY LEAKAGE, GPH TOTAL TUBES REQUI RIHG CORRECTIVE ACTIOH A

9 TYPE OF DEGRADATION 14$ %

REQUIRED REPAIRS A

8 Hl. TUBES PLUGGED A

8 IIO. TUBES SLEEVED A

8 NO. PLUGCED NO. PLUGGED RETURHED RETURNED TO SERVICE TO SERVICE HO.

SLEEVES NO.

PULLED TOTAL V1TH SLEEVE VITHOUT SLEEVE PLUGGED TUBES PLUGCED A

8 A

8 A

8 A

8 A '8 TOTAL SLEEVED CONNEHT A

8 IN FACTORY APRIL 1912 QRCH 1914 NOV.

1974 QRCH 1975 JAL 1978 ffB.

1978 APRIL 1978 APRIL 1977 JULT 1977 JAL 1918 APRIL 1978 FEB.

1979 DEC.

1979 APRIL 198l NOV.

198l HAY 1981 FEB.

1982 SEP.

1982 APRIL 1983 QRCH 1984 QRCH 1985 ffB.

1988 ffB.

1987 ffB.

1988 QR.

1988 QR.

1989 QR.

199$

1$ 5$

3259 516 17II 43I 2174 442 I

I 3192 3192 ISI I

2ll3 268 1898 516 672 39 1931 442 53 I

3247 3247 1$25 75 1525 268 3bl 3139 325 3138 325 3138 325 3137 526 3138 382 3137 633 3137 717 3135 3135 3134 623 3128-I 3122 1517 I

I 3128 1668 2949 663 3182 375 3151 375

'3141 4$I 314$ $26 3129 893 3I96 832 3I93 963 3$ 87 3$87 3$83 77$

2884 I

2723 13$ 1 2$ 8 I

28I5 1486 2437 653 2$ 49 325 1114 375 2$ 49 325 1714 375 S.IIS A 5/G I.$91 8 S/G l.l99 8 S/G

$.$ 12 B S/G

$.$6 8 S/C

$.$$7 8 S/G 7$ $ 8 5/G

$.13 9 S/G I I I I 19 I

2 I

46 11 I

2 39 2

15 13 2

I 6

I 8

I 15 I

6 I

13 I

31 I I I

I 18 I

33 4

I I

3 6

27 34 73 7

41 I

9 177 445 75 211 I

I I

I VASTAGE 19 I

VASTAGE 2

I CRACK INC/VASTACE 46 11 VASTAGE I

2 VASTACE 39 2

CRACKING I

15 I/ASTAGE 13 I

ID CRACKIHG P

5 CRACKIHG/VASTAGE I

8 ID CRACKIHG I

15 CRACKING/VASTAGE/IQ I 6

IGA/VASTAGE I

13 h'PITTIHC/'8'IQ I

13 ICA I

2 IQ/VASTAGE I

6 IQ/NECH. DAN I

16 IQ I

28 IGA/SCC I

23 IQ/SCC 5

IGA/SCC/VASTAGE 3

7$

IGA/SCC/VASTAGE 2

49 IGA/SCC 17 78 IQ/SCC 18 IQ/SCC I

6 IQ/SCC/PVSCC/VAS 21 142 IGA/SCC/PVSCC/VAS 18 7l I

I I

I 19 I

2 I

46 11 I

2 39 2=

I 15 13 I

I 5

I 8

15 I

6 I

13 I

34 I

I 18 I

33 I

3 I

I 2

4 I

27 ll 72 14 58 I

8 36 73 22 2$

I I

I I I I I

I I I S

I I I I I I I I

I I

I I I I I I

5 I

16 I I I I 4

74 I

9 2

67 6

3$

24 8$

I I I I 132 3$6 56 163 II I

I I

II I

PI II I

III II IIIIIII I

II I

I I

III II I

II II I

IIIII 3

III 64 28 II III II I

I I

I I

SIII I

I I

IIII I

II 18 I

I I

I I I

8 I

I I

I I I I

I I

I I I I I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I I I I I

3 I

I I

I 4

5 5

I I I I

I 2

I I I 2

I I

I I

P I

I I

I I

I I

I I

I I

I P

I I

3 I I I

3 I

I I

I I

I I

I I I I I I

I I I I

I I

I 2

I I

I I

I 19 I

2 I

46 11 I

2 39 2

I 15 13 I

I 5

I 8

I 15 I

6 I

13 I

34 I

I I

4 I

18 I

33 I

4 I

2 2

4 I

24 II 75 15 59 I

9 22

-4 24

-8 8

I I

I I

I I

I I

I I

I I

I

)

I I I

I I

I I

I I

I I

I I

I I

I I

I 5

2 I

16 3

I I 4

I I 4

73 5

I 8

2 67 6

6 33 7

24 71 8 I 9

I -I IS 137 365 ll 51 19$

12 43l 981 2$8 433 224 75$

95 18 1$

13 6

9 197 332 223 832 TABLE Page 63 of 69 K. J. Vechter 26-Apr-9$

Rev. I

.A

STEAM GENERATOR TUBE INSPECTION AND CORRECTIVE ACTION HISTORY COMMENTS FROM TABLE 7 (1)

Pulled R15 C55 and R17 C41 from the hot leg and R17 C40 from the cold leg to determine IGA conditions in the "B" steam generator.

R17 C41 and ECT indications at all. frequencies, R15 C44 had only 100 kHz Absolute ECT indication and R17 C40 had no ECT indication.

Both hot leg tubes had approximately 504 IGA, R17 C41 had a 60% SCC indication associated with the IGA.

(2)

Manually sleeved 5 tubes with nickel plated Inconel 600 thermally treated sleeves.

Three tubes had IGA indications, two others were preventatively sleeved.

Sleeved 16 tubes with co-extruded

sleeves, 13 with defects and 3

preventatively.

Pulled Hot Leg tubes R21 C4'6 with a 100 kHz ECT indication, R7 C45 and R28 C 45 which were clean tubes.

(4)

Recovery from the January 25, 1982 Tube Rupture Event including removing 26 tube sections by EDM and ID cutters along with the one tube pulled from the secondary side.

(5)

The four tubes identified with IGA in the "A" steam generator were sleeved with 22" tubesheet sleeves.

The 78 tubes identified in the Page 64 of 69

4

"B" steam generator with IGA and/or SCC in the crevice were repaired as follows:

41 tubes were sleeved with 36" brazed sleeves 9

tubes were sleeved with 28" brazed sleeves 24 tubes were sleeved with 22" tubesheet sleeves 1

tube and 2 sleeves were plugged 1

tube R34 C54 was pulled for metallurgical analysis (6)

The two tubes identified with IGA in the crevice in the "A" steam generator inlet were sleeved with 20" tubesheet, sleeves.

One indication >40%

TWD in the U-bend was permanently plugged.

The 70 tubes identified in the "B" steam generator were repaired as follows:

56 tubes were sleeved with 20" tubesheet sleeves 10 tubes were sleeved with 36" brazed sleeves 3

tubes were mechanically plugged (CE removable) 1 tube was explosively plugged 1

tube was sleeved with a 36" brazed sleeve due to the domino effect.

(7)

The five tubes identified with crevice indications in the "A" steam generator inlet were s1eeved with 27" Combustion Engineering (CE)

Sleeves.

One tube identified with an O.D. general indication above the secondary side tubesheet was also sleeved with a 27" CE sleeve.

Page 65 of 69

l.

0

The 57 tubes identified in the "B" steam generator were repaired as follows:

27 tubes were sleeved with 27" CE sleeves 27 tubes were mechanically plugged (CE removable) 3 CE Mechanical Plugs installed in 1985 were removed and sleeved with 27" sleeves The present sleeve installation status is 83 brazed

sleeves, 88 tube sheet sleeves, 30 welded CE sleeves in the "B" steam generator with 6 tubesheet sleeves and 6 welded CE sleeves in the "A" steam generator.

(8)

The 34 tubes identified with crevice indications in the "A" steam generator inlet were repaired as follows:

10 tubes were mechanically plugged (CE removable) 24 tubes were sleeved with 27" CE welded sleeves The 153 tubes identified with crevice indications in the "B" steam generator inlet were repaired as follows:

72 tubes were mechanically plugged (CE removable) 80 tubes were sleeved with 27" CE welded sleeves 1

CE welded sleeve (installed in 1987) was plugged with a CE welded sleeve plug due to rejection of upper weld.

Other repairs required in the "B" steam generator are as follows:

2 B&W test brazed sleeves (installed in 1980) were plugged due to the loss of the primary to secondary pressure boundary as detected by the Hydro Test.

Page 66 of 69

5 Westinghouse explosive plugs installed prior to 1987 were removed due to leakage and replaced with CE welded plugs.

1 CE Mechanical Plug on the cold leg was removed and replaced with a CE Mechanical Plug.

4 CE welded sleeves (installed in 1987), are considered as "leak limiting" due to the marginal acceptance of the upper welds.

(9)

In the "A" steam generator, 15 tubes were plugged for the following reasons:

7 tubes had tubesheet crevice indications 7

tubes for no confirmed AVB support 1

CE sleeve for unverified upper expansion In "B" steam generator, 61 tubes were plugged for the following reasons:

39 tubes had tubesheet crevice indications 2

tubes were missplugged in the hot leg during 1987 outage 8

tubes to box existing plugs were AVB support could not be verified.

'0 tubes for no confirmed AVB support 1

tube for flow peaking consideration due to AVB placement 8

Westinghouse Explosive Plugs were removed and replaced with welded "Top Hat" Plugs Page 67 of 69

l

~ 1

)

The "B" steam generator had 9 tubes plugged for the following reasons:

6 tubes had tubesheet crevice indications identified by a review of the February data.

These were removed from service with CE mechanical plugs.

2 tubes had signal changes from February to March.

The tubes were removed from service with CE mechanical plugs.

1 B&W tubesheet sleeve identified by the hydrostatic pressure test was removed from service with a

B&W explosive plug in the hot leg and a CE mechanical in the cold leg.

(ll) A total of 177 tubes in "A" steam generator were repaired in 1989 as follows:

137 CE 27" welded sleeves (straight and periphery) 40 Tube and/or sleeve plugs 2

Previously plugged tubes stabilized (not counted as repaired)

A total of 445 tubes were repaired in "B" steam generator were repaired as follows:

367 CE 27" welded sleeves (straight and periphery) 78 Tubes and/or sleeve plugs 1

Previously plugged tube stabilized (not counted as repaired)

Page 68 of 69

0

gn 4

)

A total of 75 tubes in "A" steam generator were repaired in 1990 as follows:

51 CE 27" welded sleeves (straight and periphery) 24 Tube and/or sleeve plugs (includes pulled tubes R25-C63 and R31-C66)

A total of 211 tubes were repaired in "B" steam generator were repaired as follows:

191 CE 27" welded sleeves (straight and periphery) including I

28 deplugged tubes 20 Tubes and/or sleeve plugs (includes B&W tubesheet sleeve noted during hydro)

Page 69 of 69