c."
Records of plant ra'diation and contamination surveys.
~'Ci'.
Records of off-site environmental monitoring surveys.
e.
Records of radiation exposure of all plant personnel-,
including all contractors and visitors to the plant who enter radiation control areas.
f.
Records of radioactivity in liquid and gaseous material released to the environmental and radioactive waste shipments..
g.
Records of transient or operational cycles for those facility components designed for limited number of transients or cycles.
h.
Records of training and qualification for current station technical and operations staff members.
Records of in-service inspections performed pursuant to these Technical Specifications.
j.
Records of reviews performed for changes made to proce-dures or equipment or reviews of tests and experiments pursuant to 10 CFR Section 50.59.
k.
Records of meetings of the PORC and the NSARB.-
1.
Records of Quality Assurance activities as required by the QA Manual.
m.
Records for Environmental Qualification which are covered under the provisions of paragraph 6.14.
8ous!tee
<(
6.10-2 Change No.~
Order dated Oct,.
24, 1980
~ ~
~ ~ ~
~ P 6.14 ENfIRONHEhTAL OUALIFICATInn A.
By no la er San June 30, 1982 all safety-relat d electrical equ',paent in the;:-cility sfell be qualified in accoi dance with the provisions of:
Division.of Dperating Reactors
."Guidelines for Evaluating Enviromaenul Qualification of Class EE Electrical Equipment in Operating Reactors" (DOR Guidelines); or, NUREG-0588 "Interim Sta,f Position on Environmental
'gualification of Safety-Related Electrical Equipment",
December 1979.
Copies of these ducal:n s are a tached to Order for Modification of
~
License DPR-18 datecf
. October 24, 1980.
B.
By.no la. r than December 1, 1980, complete-and auditible re"ords must be availab'le and maintained at a central location which describe he
~,
envirorroental quali fication,me hod used for all safety-related electrical equipaent in sufficient devil to documen the degre of comp'liance with the D0R Guidelines 'or HUREG-0588.
Thereafter, such records shou1d be updc ed and maintained current cs equipmen is
- replaced, further tested, or otherwise furth r qualified.
~y~ ~
o Opt 0
Order da ed Oct. 24, 1980 6 14 1-.
hov 1s 1980