Notice of Violation from Insp on 781023-25
ML17244A299
Person / Time
Site: Ginna 
Issue date: 11/13/1978
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML17244A296 List:
References
50-244-78-22, NUDOCS 7901030112
Download: ML17244A299 (2)


Text

APPENDIX A NOTICE OF YIOLATION Rochester Gas and Electric Corporation Rochester, New York 14649 Docket No. 50-244 Based on the results of an NRC inspection conducted on October 23-25, 1978, it appears that certain of your activities were not conducted in full compliance with NRC regulations and the conditions of your NRC Facility License No.

DPR-18, as indicated below.

This item is cate-gonzed as an Infraction.

Section 6.8.1 of the Technical Specifications requires, in part, that written procedures be established; implemented and maintained covering the activities referenced in Appendix "A" of Regulatory Guide 1.33, November 1972.

Those activities include the liquid and gaseous radioactive waste systems sampling and monitoring.

Contrary to these requirements, written procedures were not estab-

lished, implemented or maintained for the computer-based, multi-channel analyzer system which was used since July 1978 to monitor liquid and gaseous radioactive wastes released from the plant.

. 0 0

~ ry~>+t