{{#Wiki_filter:H Nebraska Public Power District NLS2017071 August 17, 2017 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001 Alwa)S there when )OU need us 10 CFR 50.55a

Subject:

10 CFR 50.55a Relief Requests for Fifth Ten-Year Inservice Inspection Interval Cooper Nuclear Station, Docket No. 50-298, License No. DPR-46

Dear Sir or Madam:

The purpose of this letter is for the Nebraska Public Power District (NPPD) to request that the Nuclear Regulatory Commission (NRC) grant relief from, and authorize alternatives to, certain inservice inspection code requirements for the Cooper Nuclear Station (CNS) pursuant to 10 CFR 50.55a. The 10 CFR 50.55a requests pertain to inservice examination test requirements in Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Relief Request RI5-02, Revision 1, is included which provides an updated inspection history to include the Fall 2016 refueling outage. Updates are designated by change bars in the right-hand column. The applicable ASME Code for the fifth ten-year interval is the 2007 Edition, 2008 Addenda. These requests are applicable to the fifth ten-year inservice inspection interval, which began on April 1, 2016. In order to support planning for Refueling Outage 30, NPPD requests approval of these requests by August 1, 2018. The attachment contains the relief requests for the fifth ten-year interval. Enclosures 1 and 2 are included to support Relief Requests RR5-02 and RR5-03. Formal licensee commitments are being made in this submittal and are included immediately following this cover letter. Should you have any questions concerning this matter, please contact Jim Shaw, Licensing Manager, at (402) 825-2788. Sincerely, KH v'\\v1 0, L /,., (Tu khO+.i J-~ John Dent, Jr. Vice President - Nuclear and Chief Nuclear Officer /dv COOPER NUCLEAR STATION PO Box 98 / Brownville, NE 68327-0098 Telephone: (402) 825-3877 / Fax: (402) 825-5277 www.nppd.com

NLS2017071 Page 2 of2

Attachment:

Cooper Nuclear Station Inservice Inspection Program Fifth Ten-Year Interval 10 CFR 50.55a Relief Requests

Enclosures:

1. RR5-02, Cooper Nuclear Station; Structural Integrity Associates, Inc.
2. RR5-03, Cooper Nuclear Station; Structural Integrity Associates, Inc.

cc: Regional Administrator w/ attachment and enclosures USNRC - Region IV Senior Project Manager w/ attachment and enclosures USNRC - NRR Plant Licensing Branch IV Senior Resident Inspector w/ attachment and enclosures USNRC-CNS NPG Distribution w/o attachment or enclosures CNS Records w/ attachment and enclosures

.T. ~Entergy NUCLEAR MANAGEMENT MANUAL QUALITY RELATED INFORMATIONAL USE O-EN-Ll-106 REV. 13C3 PAGE 28 OF 46 Regulatory Correspondence ATTACHMENT 9.3 LICENSEE - IDENTIFIED COMMITMENTS TABLE Sheet 1of1 This table identifies actions discussed in this letter which Nebraska Public Power District commits to perform. Any other actions discussed in this submittal are described for the NRC's information and are not regulatory commitments. TYPE (Check one) SCHEDULED ONE-TIME CONTINUING COMPLETION DATE COMMITMENT/COMMITMENT NO. ACTION COMPLIANCE Commitment# - NLS2017071-01 x Within 60 days of For a leaking flaw, the allowable leakage rate NRC approval of will be determined by dividing the critical Relief Request RR5-leakage rate by a safety factor of four ( 4 ). The 03 critical leakage rate is determined as the maximum leakage rate that can be tolerated. The critical leakage rate may be based on the allowable loss of inventory or the maximum that can be tolerated relative to room flooding, among others. Commitment# - NLS2017071-02 x Within 60 days of The number of augmented examination NRC approval of locations shall be increased from 5 (current Relief Request RR5-number in Code Case N-513-4) to 10. 03 Commitment# - NLS2017071-03 x Within 60 days of For leakage rates greater than 5 gpm, the NRC approval of leakage shall be stopped throughout the Relief Request RR5-temporary acceptance period by the use of 03 engineered mechanical clamping designed by CNS. The engineered mechanical clamping design shall be sufficient to withstand the maximum operating pressure and removable such that frequent periodic inspections defined in paragraph 2(e) of N-513-4 may be performed.

NLS2017071 Attachment Page 1of68 Acronyms Attachment Cooper Nuclear Station Inservice Inspection Program Fifth Ten-Year Interval 10 CFR 50.SSa Relief Requests Page # 2 RI5-01 Implementation of BWRVIP-05 (GL 98-05) 3 RI5-02, Rev. 1 Implementation ofBWRVIP Documents in Lieu ofB-N-1 and B-N-2 9 RI5-03 Implementation of Code Case N-702 4 7 RR5-02 Use Code Case N-513-4 58 RR5-03 Use Code Case N-513-4 at a Higher System Operating Pressure 63

NLS2017071 Attachment Page 2of68 Acronyms ADAMS Agencywide Documents Access and NRC Management System AHC Access Hole Cover NRI ART Adjusted Reference Temperature NV ASME American Society of Mechanical PEO Engineers BWR Boiling Water Reactor PoF BWRVIP Boiling Water Reactor Vessel PSIG Internals Project CE Combustion Engineering PT CF Chemistry Factor Pff CFR Code of Federal Regulations PTLR CNS Cooper Nuclear Station OE CRDRL Control Rod Drive Return Line RAMA cs Core Spray RE xx EFPY Effective Full Power Year RG EPRI Electric Power Research Institute RHR EVT-1 Enhanced Visual (VT-1) Testing RHRSWB FEM Finite Element Method RIC SIL FF Fluence Factor RPV FW Feed water RTNDT GE SIL Generic Electric Service Information sec Letter GL Generic Letter SER GPM Gallons Per Minute SIL HAZ Heat Affected Zone SLC ID Inner Diameter SRM IEB Inspection and Enforcement Bulletin SW IGSCC Intergranular Stress Corrosion TG Cracking IR Inner Radius TLAA IRM Intermediate Range Monitor USNRC ISI Inservice Inspection USAR JP Jet Pump UT LRA License Renewal Application VT LTOP Low Temperature Overpressure VT-1 MVT-1 Modified Visual Inspection VT-2 NPPD Nebraska Public Power District VT-3 Nuclear Regulatory Commission No Recordable Indications Nozzle-to-Vessel Period of Extended Operation Probability of Failure Pounds per Square Inch Liquid Penetrant Examination Pressure and Temperature Pressure and Temperature Limits Report Operating Experience Radiation Analysis Modeling Application Refuel Outage Re!!Ulatory Guide Residual Heat Removal Residual Heat Removal Service Water Booster Rapid Information Communication Service Information Letter Reactor Pressure Vessel Reference Temperature, Nil Ductility Temperature Stress Corrosion Cracking Safety Evaluation Report Service Information Letter Standby Liquid Control Source Range Monitor Service Water Top Guide Time Limited Aging Analyses United States Nuclear Regulatory Commission Updated Safety Analysis Report Ultrasonic Testing Visual Inspection Detailed Inspection Leakage Inspection General Condition Inspection

NLS2017071 Attachment Page 3 of68 10 CFR 50.55a Request No. RI5-01 Implementation of BWRVIP-05 (GL 98-05) Proposed Alternative in Accordance with 10 CFR 50.55a(z)(l) Acceptable Level of Quality and Safety ASME Code Component(s) Affected Code Class: ASME Section XI Code Class l Component Numbers: RPV Circumferential Shell Welds (VCB-BB-1, VCB-BA-2, VCB-BB-3, VCB-BB-4) Code

References:

ASME Section XI, 2007 Edition with 2008 Addenda Examination Category: B-A Item Number(s): Bl.11 Unit/Inspection Interval: Cooper/Fifth 10-year interval April 1, 2016 - February 28, 2026

Applicable Code Edition and Addenda

ASME Section XI, 2007 Edition through the 2008 Addenda Applicable ASME Code Requirements Table IWB-2500-1, Examination Category B-A, Item No. B 1.11, requires a volumetric examination of the circumferential shell welds each interval.

Reason for Request

NPPD is requesting an alternative in accordance with 10 CFR 50.55a(z)(l) on the basis that this alternative provides an acceptable level of quality and safety. This request for alternative would provide relief from circumferential weld examinations required by the ASME Section XI Code for the extended period of operation. CNS was previously granted this relief for the remainder of the original 40-year license term (Reference 6). During the staffs review of the CNS LRA (Reference 1), the staff concluded that CNS had demonstrated, in accordance with 10 CFR 54.21(c)(l)(ii), that for RPV circumferential weld examination relief, the analysis had been projected to the end of the period of extended operation. The staff also concluded that the USAR Supplement contained an appropriate summary description of the TLAA evaluation in accordance with 10 CFR 54.21 ( d) and therefore, was acceptable (Reference 2).

NLS2017071 Attachment Page 4of68 10 CFR 50.55a Request No. RI5-01 (continued) Implementation of BWRVIP-05 (GL 98-05) Proposed Alternative and Basis for Use Proposed Alternative CNS requests the use ofBWRVIP-05 with supporting information described herein as the bases for excluding the RPV shell circumferential welds from the examinations required by ASME Section XI, Examination Category B-A, Item No. B 1.11 for the extended license period ending on January 18, 2034. The axial weld seams (Examination Category B-A, Item No. Bl.12) and their intersection with the associated circumferential weld seams will be examined in accordance with ASME Section XI except where specific relief is granted when essentially 100% (>90%) coverage cannot be obtained. Basis for Use The technical basis supporting the requested alternative is provided by BWRVIP-05, (EPRI TR-105697) "BWR Vessel and Internals Project, BWR Reactor Pressure Vessel Shell Weld Inspection Recommendations" as accepted in the staffs final safety evaluation report enclosed in a July 28, 1998, letter (Reference 4). In this letter, the staff concluded that because the failure frequency for circumferential welds in BWR plants is significantly below the criterion specified in RG 1.154, "Format and Content of Plant-Specific Pressurized Thermal Shock Safety Analysis Reports for Pressurized Water Reactors," and below the core damage frequency of any BWR plant, continued inspection would result in a negligible decrease in an already acceptably low RPV failure probability. Therefore elimination of the ISI requirements for RPV circumferential welds is justified. The staffs letter indicated that BWR applicants may request relief from ASME Code Section XI requirements for volumetric examination of circumferential RPV welds by demonstrating that (1) the failure frequency for circumferential welds in BWR plants must be significantly below the criterion specified in RG 1.154 and below the core damage frequency of any BWR plant, therefore, the failure frequency for RPV circumferential welds; and (2) the applicants must implement operator training and operating procedures that limit the frequency of cold over-pressure events to the amount specified in the July 28, 1998, SER for the BWRVIP-05 report. The letter also indicated that the requirements for inspection of RPV circumferential welds during an additional 20-year license renewal period would need plant-specific reassessment as part of any BWR LRA. The applicant also must request relief from the ASME Code Section XI requirements for volumetric examination of circumferential welds for the extended license term in accordance with 10 CFR 50.55a(z). LRA Section 4.2.5 provided a comparison of the plant-specific information with the generic analysis information in BWRVIP-05 SER to support the conclusion that the CNS RPV beltline circumferential weld parameters at 54 EFPY remained within the bounding parameters for CE RPVs at 64 EFPY from the BWRVIP-05 SER. Since the 54 EFPY mean ART value for CNS is

NLS2017071 Attachment Page 5of68 10 CFR 50.55a Request No. RI5-01 (continued) Implementation of BWRVIP-05 (GL 98-05) less than the 64 EFPY value from the BWRVIP-05 SER, the staff review concluded that the RPV conditional failure probability for CNS at 54 EFPY was bounded by the staffs generic analysis in the BWRVIP-05 SER. Therefore, the staff determined that CNS' s RPV circumferential welds satisfy the limiting conditional failure probability for circumferential welds at the end of the period of extended operation (the first condition established in the BWRVIP-05 SER). Table 1 compares the CNS reactor vessel limiting circumferential weld parameters to those used in the NRC analysis. The data in the second column is from Table 2.6-5 of the NRC SER for BWRVIP-05. The data in the third column is from Table 4.2-6 of the LRA (Reference 1). The data in the last column is the projected 54 EFPY data for CNS and has been updated to include the changes contained in the PTLR Revision 1 (Reference 3). Consistent with previous submittals, this table uses surface fluence rather than 1 /4t fluence and no margin for RT NDT to be comparable with NRC assessment data, hence the reported ART is lower than that reported in the PTLR (Reference 3). Table 1 CNS Circumferential Weld Evaluation for 54 EFPY Parameter Description CE(VIPfl 64 EFPY CNS 54 EFPY Beltline CNS 54 EFPY Beltline Bounding Parameters Circumferential Weld Circumferential Weld (LRA Values) [Ref l] (Updated PIT Values) [Ref 3] Initial reference 0 -50 -50 temperature (RT NDT), °F Neutron fluence at the end of the requested 4.0E+ l8 1.48E+ l8 l.75E+ l8 relief period, n/cm2 Weld copper content, % 0.13 0.183 0.183 Weld nickel content, % 0.71 0.704 0.704 Weld chemistry factor 151.7 172.22 172.22 (CF) Increase in reference temperature (.6.RT NDT ), 113.2 86.1 92.6 Of Mean adjusted reference temperature (ART), °F 113.2 36.l 42.6 (Initial RT NDT + .6.RT NDT) (1) Based on chemistry report by BWRVIP For the second condition, the staff review of the original request for the 4th Interval, concluded that the CNS implementation of operator training and establishment of procedures, limiting the frequency of code over-pressure events to the frequency specified in BWRVIP-05 SER for the remaining initial licensed period of operation described in the letter dated February 6, 2008, was

NLS2017071 Attachment Page 6 of68 10 CFR 50.55a Request No. RI5-01 (continued) Implementation of BWRVIP-05 (GL 98-05) acceptable. In LRA Section 4.2.5, CNS stated that the same procedures and training will be used for the period of extended operation. Based on this the staff determined that continued implementation of operator training and establishment of procedures limiting the frequency of cold over-pressure events would be satisfied during the period of extended operation (the second criterion established in the BWRVIP-05 SER). In addition to the above criterion, in the BWRVIP-05 SER (Reference 4), the staff concludes that the failure probability of the RPV circumferential shell welds is substantially less than that of the RPV axial shell welds. In the LRA Table 4.2-7, CNS summarized the effects of irradiation on the limiting axial weld at CNS and compared its properties to the NRC limiting plant-specific data used in the July 28, 1998, SER for BWRVIP-05. The higher copper content and chemistry factor for the CNS weld is offset by the CNS weld's lower initial RT NOT. Consequently, the CNS axial welds are less susceptible to irradiation damage than the NRC limiting plant-specific case. During the staffs review of the LRA, a comparison of the mean ART values of CNS weld data in Table 4.2-6 and Table 4.2-7 of the LRA and concluded that the mean ART for the axial welds at CNS is higher than the mean ART for the circumferential weld, indicating that the axial welds are more susceptible to radiation embrittlement than the circumferential welds. Table 2 compares the CNS reactor vessel limiting axial weld parameters to those used by the NRC analysis in BWRVIP-05. The data in the second column is from Table 2.6-5 of the NRC SER for BWRVIP-05 (Reference 4) and Table 1 of the NRC SER for BWRVIP-74 (Reference 5). The data in the third column is from Table 4.2-7 of the LRA (Reference 1 ). The data in the last column is the projected 54 EFPY data for CNS and has been adjusted to include the changes contained in the PTLR (Reference 3). Consistent with previous submittals, this table uses surface fluence rather than l/4t fluence and no margin for RTNoTto be comparable with NRC assessment data hence the reported ART is lower than that reported in the PTLR (Reference 3). Table 2 Effects of irradiation on CNS RPV Axial Weld Properties Parameter Description NRC Limiting CNS Data for Weld CNS Data for Weld Plant-Specific Data 2-233-B [Ref. I] 2-233-B [Ref. 3] (LRA Values) (Updated P/T Values) EFPY 64 54 54 Initial (unirradiated) reference temperature -2* -50 -50 (RTNor), °F Neutron fluence, n/cm' 0.40E+ l9** l.46E+ l8 1.72E+l8 Fluence factor (FF) NIA 0.497 0.534 (calculated per RG 1.99) Weld copper content, % 0.219 0.27 0.27 Weld nickel content, % 0.996 1.035 1.035

NLS2017071 Attachment Page 7of68 Weld chemistry factor (CF) (calculated per RG 1.99) Increase in reference temperature (~RT NOT), °F (FF x CF) Mean adjusted reference temperature (ART), °F (RTNDT + ~RTNoT) 10 CFR 50.55a Request No. RI5-01 (continued) Implementation of BWRVIP-05 (GL 98-05) 231.l ** 254.43 116.0 126.5 114.0* 76.5

  • NRC SER to BWRVIP-74[Ref. 5]
    • NRC SER to BWRVIP-05[Ref 4]

254.4 135.8 85.8 To summarize, the additional analysis described in Section 4.2.5 of the LRA as modified by the changes contained in the PTLR (Reference 3) shows that the parameters projected to 54 EFPY for the CNS RPV are bounded by the staff's (64 EFPY) bounding parameters for a CE vessel in the BWRVIP-05 SER. Additionally, the CNS RPV axial welds are less susceptible to irradiation damage than the NRC limiting plant-specific case, but are more susceptible than the CNS circumferential welds. Therefore, continuation of ISi for axial welds provides additional assurance that the structural integrity of the circumferential welds is adequate. The procedures and training used to limit low temperature over-pressure events will be the same as those in use when CNS requested approval of the BWRVIP-05 technical alternative for the initial license term. The TLAA associated with reactor vessel circumferential weld inspection relief has been projected to the end of the period of extended operation in accordance with 10 CFR 54.2l(c)(l)(ii). Based on the information presented in this request, the referenced LRA with the corresponding NRC SER, and the information provided in the PTLR, the circumferential welds will continue to satisfy the limiting conditional failure probability for circumferential welds in the staff's July 28, 1998, safety evaluation. Duration of Proposed Alternative The duration of this request is for the extended license period ending January 18, 2034. Precedents "Peach Bottom Atomic Power Station, Units 2 and 3 - Requests for Reliefl4R-51 and 15R-52," dated January 24, 2012 (ADAMS Accession Number MLl 12770217). "Browns Ferry Nuclear Plant, Units 2 and 3 - Request for ASME Code, Section XI, Alternatives 2-ISI-30 and 3-ISI-27 for the Periods of Extended Operation Regarding Reactor Pressure Vessel Circumferential Shell Weld Examinations," dated March 14, 2017 (ADAMS Accession Number MLl 7045A 772).

NLS2017071 Attachment Page 8of68 References 10 CFR 50.55a Request No. RI5-01 (continued) Implementation of BWRVIP-05 (GL 98-05)

1. NPPD letter to the U.S. NRC, "Cooper Nuclear Station, License Renewal Application, Preface through Chapter 4, References," dated September 24, 2008 (ADAMS Accession No. ML083030239).
2. US NRC letter to NPPD, "Safety Evaluation Report Related to the License Renewal of Cooper Nuclear Station," dated September 1, 2010 (ADAMS Accession No. ML102000270).
3. NPPD letter to the U.S. NRC, "Pressure and Temperature Limits Report, Revision l," dated January 9, 2017 (ADAMS Accession No. MLl 7018Al51 and MLl 7018Al52).
4. J. Strosnider (NRC), to C. Terry (BWRVIP Chairman), "Final Safety Evaluation of the BWR Vessel and Internals Project BWRVIP-05 Report {TAC NO. M93925)," letter dated July 28, 1998.
5. C. Grimes (NRC), to C. Terry (BWRVIP Chairman), "Acceptance for Referencing ofEPRI Proprietary Report TR-113596, 'BWR Vessel and Internals Project, BWR Reactor Pressure Vessel Inspection and Flaw Evaluation Guidelines (BWRVIP-74)' and Appendix A,

'Demonstration of Compliance with the Technical Information Requirements of the License Renewal Rule (10 CFR 54.21)' "dated October 18, 2001 (ADAMS Accession No. MLO 12920549).

6. US NRC letter to NPPD, "Cooper Nuclear Station - Request for Relief No. RI-29 for Fourth 10-Year Inservice Inspection Interval Regarding Volumetric Examination of Reactor Pressure Vessel Circumferential Shell Welds (TAC No. MD5260)," dated February 6, 2008 (ADAMS Accession No. ML080230288).

NLS2017071 Attachment Page 9 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Proposed Alternative in Accordance with 10 CFR 50.55a(z)(l) Acceptable Level of Quality and Safety ASME Code Component(s) Affected Code Class: Examination Category: Item Number(s): Component Numbers: ASME Section XI Code Class 1 B-N-1, B-N-2 Bl3.10, Bl3.20, Bl3.30, and Bl3.40 Various

Applicable Code Edition and Addenda

ASME Section XI, 2007 Edition through the 2008 Addenda Applicable ASME Code Requirements Table IWB-2500-1, Examination Categories "B-N-2, Welded Core Support Structures and Interior Attachments to Reactor Vessels," "B-N-3, Removable Core Support Structures" requires examinations based on the following Item Numbers: B 13.10 Examine accessible areas of the reactor vessel interior (B-N-1) each period by the VT-3, visual examination method; includes only those spaces above and below the core made accessible by removal of components during normal refueling outages Bl3.20 Examine accessible interior welded attachments within the beltline region each interval by the VT-1, visual examination method (B-N-2) Bl3.30 Examine accessible interior welded attachments beyond the beltline region each interval by the VT-3, visual examination method (B-N-2) B 13.40 Examine the accessible surfaces of welded core support structures each interval by the VT-3, visual examination method (B-N-2) These examinations are performed to assess the structural integrity of the reactor vessel interior, its welded attachments, and the welded core support structure within the boiling water reactor pressure vessel.

Reason for Request

In accordance with 10 CFR 50.55a(z)(l ), NPPD is requesting NRC approval of a proposed alternative to the Code requirements provided above on the basis that the use of the BWRVIP guidelines discussed below provide an acceptable level of quality and safety.

NLS2017071 Attachment Page 10of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 The BWRVIP Inspection and Evaluation Guidelines recommend specific inspection by BWR owners to identify material degradation with BWR components. A wealth of inspection data has been gathered during these inspections across the BWR industry. The BWRVIP Inspection and Evaluation Guidelines focus on specific and susceptible components, specify appropriate inspection methods capable of identifying known or potential degradation mechanisms, and require re-examination at appropriate intervals. The scope of the BWRVIP Inspection and Evaluation Guidelines exceed that of ASME Section XI and in most instances include components that are not part of the ASME Section XI jurisdiction. Use of this proposed alternative will maintain an adequate level of quality and safety and avoid duplicate or unnecessary inspections, while conserving radiological dose. Revision 1 updates the BWRVIP-18 reference to Revision 2-A and provides an updated inspection history to include the Fall 2016 (RE29) refueling outage. Revision 0 of this Relief was approved by the NRC on February 17, 2016 (Reference 14). Proposed Alternative and Basis for Use Proposed Alternative NPPD requests authorization to utilize the alternative requirements of the BWRVIP Guidelines in lieu of the requirements of ASME Code Section XI. NPPD will satisfy the Examination Category B-N-1 and B-N-2 requirements as described in Table 1 on page 15 in accordance with BWRVIP guideline requirements. This relief request proposes to utilize the identified BWRVIP guidelines in lieu of the associated Code requirements, including examination method, examination volume, frequency, training, successive and additional examinations, flaw evaluations, and reporting. Not all of the components addressed by these guidelines are Code components. The proposed alternative includes: For Examination Category B-N-1: As an alternative to meeting ASME Section XI and performing a VT-3 examination of the RPV interior above and below the core made accessible by a normal refuel outage, NPPD will implement the BWRVIP Guidelines listed below and as outlined in Table 1 on page 15. By this request for alternative the BWRVIP Guidelines will be used as an alternative to the requirements of ASME Section XI. BWRVIP-03, Revision 17, "Reactor Pressure Vessel and Internals Examination Guidelines"

NLS2017071 Attachment Page 11of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu ofB-N-1 and B-N-2 BWRVIP-18, Revision 2-A, "BWR Core Spray Internals Inspection and Flaw Evaluation Guidelines" BWRVIP-25, "BWR Core Plate Inspection and Flaw Evaluation Guidelines" BWRVIP-26-A, "BWR Top Guide Inspection and Flaw Evaluation Guidelines" BWRVIP-27-A, "BWR Standby Liquid Control System/Core Plate ~p Inspection and Flaw Evaluation Guidelines" BWRVIP-41, Revision 3, "BWR Jet Pump Assembly Inspection and Evaluation Guidelines" BWRVIP-47-A, "BWR Lower Plenum Inspection and Flaw Evaluation Guidelines" BWRVIP-138 Revision 1-A, "Updated Jet Pump Beam Inspection and Flaw Evaluation Guidelines" For Examination Category B-N-2: As an alternative to meeting ASME Section XI and performing a VT-1 or VT-3, as required by ASME Section XI, examination of the RPV welded attachments and welded core support structures, NPPD will implement the BWR VIP Guidelines listed below and as outlined in Table 1 on page 15. By this request for alternative the BWRVIP Guidelines will be used as an alternative to the requirements of ASME Section XL BWRVIP-03, Revision 17, "Reactor Pressure Vessel and Internals Examination Guidelines" BWRVIP-38, "BWR Shroud Support Inspection and Flaw Evaluation Guidelines" BWRVIP-48-A, "Vessel ID Attachment Weld Inspection and Flaw Evaluation Guidelines" BWRVIP-76, Revision 1-A, "BWR Core Shroud Inspection and Flaw Evaluation Guidelines" BWRVIP-100-A, "Updated Assessment of the Fracture Toughness oflrradiated Stainless Steel for BWR Core Shrouds" Note: If flaw evaluations are required for BWRVIP-76, Revision 1-A, examinations, the fracture toughness values ofBWRVIP-100-A will be utilized. When a BWRVIP Guideline refers to ASME Section XI, the technical requirements of ASME Section XI as described by the BWRVIP Guideline will be met, but the examination is under the auspices of the BWRVIP program as defined by BWRVIP-94NP, Revision 2, "BWRVIP Vessel and Internals Project Program Implementation Guide." The NPPD reactor vessel internals inspection programs have been developed and implemented to satisfy the requirements ofBWRVIP-94NP, Revision 2. It is recognized that the BWRVIP executive committee periodically revises the BWRVIP guidelines to address industry operating experience, include enhancements to inspection techniques, and add or adjust flaw evaluation methodologies. BWRVIP-94NP, Revision 2, states that where guidance in existing BWRVIP documents has been supplemented or revised by subsequent correspondence approved by the

NLS2017071 Attachment Page 12of68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 BWRVIP Executive Committee, the vessel and internals program shall be modified to reflect the new requirements and implement the guidance within two refueling outages, unless a different schedule is specified by the BWRVIP. However, if new guidance approved by the Executive Committee includes changes to NRC approved BWRVIP guidance that are less conservative than those approved by the NRC, the less conservative guidance shall be implemented only after NRC approves the changes, which generally means publication of a "-A" document or equivalent. Therefore, where the revised version of a BWRVIP inspection guideline continues to also meet the requirements of the version of the BWRVIP inspection guideline approved by the NRC, it may be implemented. Otherwise, the revised guidelines will only be implemented after NRC approval of the revised BWRVIP guidelines or a plant-specific request for alternative has been approved. Table 1 below only represents the most current comparison. Any deviations from the referenced BWRVIP Guidelines for the duration of the proposed alternative will be appropriately documented and communicated to the NRC, per the BWRVIP Deviation Disposition Process. Note that other regulatory commitments (i.e., NUREG-0619) are still being implemented separately from the ASME Section XI Program or this request for alternative. In the event that conditions are identified that require repair or replacement and the component is within the jurisdiction of ASME Section XI (welded attachments to the RPV or Core Support Structure), the repair or replacement activities will be performed in accordance with ASME Section XI, Article IW A-4000. Subsequent examinations will be in accordance with the applicable BWRVIP Guideline. Basis for Use As part of the BWRVIP initiative, the BWR reactor internals and attachments were subjected to a safety assessment to identify those components that provide a safety function and to determine if long-term actions were necessary to ensure continued safe operation. The safety functions considered are those associated with (1) maintaining a coolable geometry, (2) maintaining control rod insertion times, (3) maintaining reactivity control, (4) assuring core cooling and (5) assuring instrumentation availability. The results of the safety assessment are documented in BWRVIP-06, Revision 1-A, "BWR Vessel and Internals Project Safety Assessment ofBWR Reactor Internals" which has been approved by the NRC. As a result of BWRVIP-06, Revision 1-A, component specific BWRVIP guidelines were developed providing appropriate examination and evaluation requirements to address the specific component safety function and potential degradation mechanism.

NLS2017071 Attachment Page 13 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Along with the component specific guidelines, the BWRVIP has established a reporting protocol for examination results and deviations. The NRC has agreed with the BWRVIP approach in principal and has issued Safety Evaluations for many of these guidelines (see References). As additional justification, page 17, "Comparison of ASME Code Section XI Examination Requirements to BWRVIP Examination Requirements," provides specific examples which compare the inspection requirements of ASME Code Section XI Table IWB-2500-1, Item Numbers Bl3.10, Bl3.20, Bl3.30 and Bl3.40 to the inspection requirements in the BWRVIP documents. Specific BWRVIP documents are provided as examples. This comparison also includes a discussion of the inspection methods. Therefore, use of the BWRVIP guidelines as an alternative to ASME Section XI, as shown by the comparison provides an acceptable level of quality and safety. Duration of Proposed Alternative This proposed alternative will be used for the Fifth Ten-Year Interval of the Inservice Inspection Program for CNS. Precedents Similar request for alternatives has been previously approved for the following other licensees.

1. US NRC letter to Entergy Operations, "Grand Gulf Nuclear Station, Unit 1 - Request for Relief GG-ISI-017, Alternative to Use Boiling Water Reactor Vessel and Internals Project Guidelines in Lieu of Specific ASME Code Requirements (TAC No. MF2357)", dated June 30, 2014 (ML14148A262).
2. US NRC letter to Entergy Operations, "River Bend Station, Unit 1 - Request for Relief No.

RBS-ISI-019, Alternative to Use Boiling Water Reactor Vessel and Internals Project Guidelines in Lieu of ASME Code, Section XI Requirements for the Fourth 10-Year Inservice Inspection Interval (TAC No. MF1867), dated May 30, 2014 (ML14127A327).

3. US NRC letter to Exelon Generation Company, LLC, "Dresden Nuclear Power Station, Units 2 and 3 - Safety Evaluation in Support of Request for Relief Associated With the Fifth l 0-y ear Inservice Inspection Interval Program (TAC Nos. ME9682, ME9683, ME9684, ME9685, ME9686, ME9687, ME9688, ME9689, ME9690, ME9691, ME9692, ME9693, ME9694, ME9695, ME9696, and ME9697), dated September 30, 2013 (ML13260A585).
4. US NRC letter to Exelon Generation Company, LLC, "Quad Cities Nuclear Power Station Units 1 and 2 - Safety Evaluation in Support of Request for Relief Associated With the Fifth 10 Year Interval Inservice Inspection Program (TAC Nos. ME9668, ME9669, ME9670,

NLS2017071 Attachment Page 14of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 l\\.1E9671, l\\.1E9672, l\\.1E9674, l\\.1E9675, l\\.1E9676, l\\.1E9677, l\\.1E9678, l\\.1E9679, l\\.1E9680, l\\.1E968 l ), dated September 30, 2013 (l\\.1L 13267 A097).

5. US NRC letter to Exelon Nuclear, "Oyster Creek Nuclear Generating Station - Relief From the Requirements of the AS1\\.1E Code, Relief Request No. I5R-Ol (TAC No. l\\.1E9490), dated August 5, 2013 (l\\.1Ll3169A062).

References

1. US NRC letter to BWRVIP, "Safety Evaluation by the Office of Nuclear Reactor Regulation Topical Report, BWRVIP-06-A: BWR (Boiling Water Reactor) Vessel and Internals Project (BWRVIP), Safety Assessment ofBWR Reactor Internals, Revised Section 4.0:

Consideration of Loose Parts" (TAC No. l\\.1C7448) dated July 29, 2008 (l\\.1L082030758).

2. US NRC letter to BWRVIP, "Final Proprietary Safety Evaluation for Electric Power Research Institute Topical Report, "BWRVIP-18, Revision 2: Boiling Water Reactor Core Spray Internals Inspection and Flaw Evaluation Guidelines (TAC No. l\\.1F8809}," dated February 22, 2016 (l\\.1Ll6011Al99).
3. US NRC letter to BWRVIP, "Final Safety Evaluation ofBWRVIP Vessel and Internals Project, BWR Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines (BWRVIP-25)," EPRI Report TR-107284, December 1996 (TAC No. l\\.197802),"

dated December 19, 1999.

4. US NRC letter to BWRVIP, "NRC Approval Letter ofBWRVIP-26-A, BWR Vessel and Internals Project Boiling Water Reactor Top Guide Inspection and Flaw Evaluation Guidelines," dated August 29, 2005 (l\\.1L052490550).
5. US NRC letter to BWRVIP, "Non-Proprietary Version ofNRC Staff Review of BWRVIP-27-A, "BWR Standby Liquid Control System/Core Plate ~p Inspection and Flaw Evaluation Guidelines," dated June 9, 2004 (l\\.1L04 l 700446).
6. US NRC letter to BWRVIP, "Final Safety Evaluation of the "BWR Vessel and Internals Project, BWR Shroud Support Inspection and Flaw Evaluation Guidelines (BWRVIP-38),"

EPRI Report TR-108823 (TAC No. l\\.199638)," dated July 24, 2000 (l\\.1L003735498).

7. US NRC letter to BWRVIP, "Final Safety Evaluation of the "BWR Vessel and Internals Project, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines (BWRVIP-41)," (TAC No. 1\\.199870)," dated February 4, 2001 (l\\.1L0104601 l l).

NLS2017071 Attachment Page 15of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2

8. US NRC letter to BWRVIP, "NRC Approval Letter of BWRVIP-47-A, "BWR Vessel and Internals Project Boiling Water Reactor Lower Plenum Inspection and Flaw Evaluation Guidelines," dated September 1, 2005 (ML052490537).
9. US NRC letter to BWRVIP, "NRC Approval Letter of BWRVIP-48-A, "BWR Vessel and Internals Project Vessel ID Attachment Weld Inspection and Flaw Evaluation Guidelines,"

dated July 25, 2005 (ML052130284).

10. US NRC letter to BWRVIP, "Final Safety Evaluations of the Boiling Water Reactor Vessel and Internals Project 76, Rev. 1 Topical Report, "Boiling Water Reactor Core Shroud Inspection and Flaw Evaluation Guidelines" (TAC No. ME8317)," dated November 12, 2014.
11. Letter from Chairman, BWR Vessel and Internals Project to NRC, "Project No. 704 -

BWRVIP Program Implementation Guide (BWRVIP-94NP, Revision 2)," dated September 22, 2011 (ML11271A058).

12. US NRC letter to BWRVIP, "NRC Approval Letter with Comment for BWRVIP-100-A, BWR Vessel and Internals Project, Updated Assessment of the Fracture Toughness of Irradiated Stainless Steel for BWR Core Shrouds," dated November 1, 2007 (ML073050135).
13. US NRC letter to BWRVIP, "Electric Power Research Institute Final Safety Evaluation for Technical Report 1016574 "BWRVIP-138, Revision 1: BWR [Boiling Water Reactor]

Vessel and Internals Project 'Updated Jet Pump Beam Inspection and Flaw Evaluation Guidelines' (TAC No. ME2191)," dated May 14, 2012 (ML1208A139).

14. US NRC letter to NPPD, "Cooper Nuclear Station - Request for ReliefRI5-02, Alternative to Use Boiling Water Reactor Vessel and Internals Project Guidelines in Lieu of Specific ASME Code Requirements (CAC No. MF6336)," dated February 17, 2016 (ML16034A479).

NLS2017071 Attachment Page 16of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu ofB-N-1 and B-N-2 Table 1 Comparison of ASME Examination Category B-N-1 and B-N-2 Requirements with BWRVIP Guidance Requirements (Note 1) ASMEitem ASMEExam ASME ASME Applicable BWRVIPExam BWRVIP BWRVIP No. Table Component Scope Exam Frequency BWRVIP Scope Exam Frequency IWB-2500-1 Type Document Type B13.10 Reactor Vessel Interior Accessible Areas VT-3 Each Period BWRVIP-18, Overview examinations of components during (Non-specific) 25, 26, 38, BWR VIP examinations are performed to satisfy 41, 47, 48, Code VT-3 inspection requirements. 76, 138 B13.20 Interior Attachments Accessible VT-1 Each 10-year BWRVIP-48 Riser Brace EVT-1 100% in first 12 within Beltline - Riser Welds Interval Table 3-2 Attachment years, 25% during Braces each subsequent 6 years Lower Surveillance BWRVIP-48, Bracket VT-1 Each l 0-Year Specimen Holder Table 3-2 Attachment Interval Brackets B13.30 Interior Attachments Accessible VT-3 Each 10-year BWRVIP-48, Bracket VT-3 Each l 0-Y ear beyond Beltline - Steam Welds interval Table 3-2 Attachment Interval Dryer Hold-down Brackets Guide Rod Brackets BWRVIP-48, Bracket VT-3 Each 10-Year Table 3-2 Attachment Interval Steam Dryer Support BWRVIP-48, Bracket EVT-1 Each 10-Year Brackets Table 3-2 Attachment Interval Feedwater Sparger BWRVIP-48, Bracket EVT-1 Each 10-Y ear Brackets Table 3-2 Attachment Interval Core Spray Piping BWRVIP-48, Bracket EVT-1 Every 4 Refueling Brackets Table 3-2 Attachment Cycles Upper Surveillance BWRVIP-48, Bracket VT-3 Each 10-Year Specimen Holder Table 3-2 Attachment Interval Brackets

NLS2017071 Attachment Page 17of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Table 1 Comparison of ASME Examination Category B-N-1 and B-N-2 Requirements with BWRVIP Guidance Requirements (Note 1) ASME Item ASMEExam ASME ASME Applicable BWRVIPExam BWRVIP BWRVIP No. Table Component Scope Exam Frequency BWRVIP Scope Exam Frequency IWB-2500-1 Type Document Type Shroud Support (Weld BWRVIP-38, WeldH-9 EVT-1 or Maximum of6 H9) including gussets 3.1.3.2, including gussets UT years for EVT-1, Figures 3-2 Maximum of 10 and 3-5 years for UT B13.40 Integrally Welded Core Accessible VT-3 Each 10-year BWRVIP-38, Shroud support EVT-1 or Based on as-found Support Structure Surfaces interval 3.1.3.2, welds H8 and H9 UT conditions, to a Figures 3-2 including gussets maximum 6 years and 3-5 for one side EVT-1, 10 years for UT where accessible Shroud Horizontal BWRVIP-76, Welds Hl-H7 as UT or Based on as-found Welds 2.2 applicable EVT-1 conditions, to a maximum of 10 years for UT when inspected from both sides of the welds Shroud Vertical Welds BWRVIP-76, Vertical Welds as EVT-1 or Maximum 10 2.3 applicable UT years for UT based on inspection of horizontal welds Note:

1. This Table provides only an overview of the requirements. For more details, refer to ASME Section XI, Table IWB-2500-1 and the appropriate BWRVIP document.

NLS2017071 Attachment Page 18of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Comparison of ASME Code Section XI Examination Requirements to BWRVIP Examination Requirements The following provides a comparison of the examination requirements provided in ASME Code Section XI Table IWB-2500-1, Examination Category B-N-1 and B-N-2, Item Numbers B13.10, B13.20, 813.30, and 813.40, to the examination requirements in the BWRVIP Guidelines. Specific BWR VIP Guidelines are provided as examples for comparisons. This comparison also includes a discussion of the examination methods. Code Requirement - 813.10 - Reactor Vessel Interior Accessible Areas (B-N-1) The ASME Section XI Code requires a VT-3 examination of reactor vessel accessible areas, which are defined as the spaces above and below the core made accessible during normal refueling outages. The frequency of these examinations is specified as the first refueling outage, and at intervals of approximately 3 years during the first inspection interval, and each period during each successive l 0-year Inspection Interval. Typically, these examinations are performed every other refueling outage of the Inspection Interval. This examination requirement is a non-specific requirement that is a departure from the traditional Section XI examinations of welds and surfaces. As such, this requirement has been interpreted and satisfied differently across the licensees, and vendors of this inspection service. Based on the acceptance criteria specified in IWB-3520.2, the examination is to identify relevant conditions such as distortion or displacement of parts, loose, missing, or fractured fasteners, foreign material, corrosion, erosion, or accumulation of corrosion products, wear, and structural degradation. Portions of the various examinations required by the applicable BWRVIP Guidelines require access to accessible areas of the reactor vessel during each refueling outage. Examination of Core Spray Piping and Spargers (BWRVIP-18-R2-A), Top Guide (BWRVIP-26-A), Jet Pump Welds and Components (BWRVIP-41-R3), Interior Attachments (BWRVIP-48-A), Core Shroud Welds (BWRVIP-76-Rl-A), Shroud Support (BWRVIP-38), and Lower Plenum Components (BWRVIP-47-A) provides such access. Locating and examining specific welds and components within the reactor vessel areas above, below (if accessible), and surrounding the core (annulus area) entails access by remote camera systems that essentially perform equivalent VT-3 examination of these areas or spaces as the specific weld or component examinations are performed. This provides an equivalent method of visual examination on a more frequent basis than that required by the ASME Section XI Code. Evidence of wear, structural degradation, loose, missing, or displaced parts, foreign materials, and corrosion product buildup can be, and has been observed during the course of implementing these BWRVIP examination requirements. Therefore, the requirements specified by the BWRVIP Guidelines meet or exceed the subject Code requirements for examination method and frequency of the interior of the reactor vessel. Accordingly, these BWR VIP examination requirements provide an acceptable level of quality and safety as compared to the subject Code requirements.

I NLS2017071 Attachment Page 19 of68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Code Requirement - B13.20 - Interior Attachments within the Beltline (B-N-2) The ASME Section XI Code requires a VT-1 examination of accessible reactor interior surface attachment welds within the beltline each 10-year interval. In the BWR, this includes the Jet Pump Riser Brace Weld-to-Vessel Wall and the Lower Surveillance Specimen Support Bracket Welds-to-Vessel Wall. In comparison, the BWRVIP requires the same examination method and frequency for the Lower Surveillance Specimen Support Bracket Welds, and requires an EVT-1 examination on the remaining attachment welds in the beltline region in the first 12 years, and then 25% during each subsequent 6 years. The Jet Pump Riser Brace examination requirements are provided below to show a comparison between the Code and the BWRVIP examination requirements. Comparison to BWRVIP Requirements - Jet Pump Riser Braces (BWRVIP-41-R3 and BWRVIP-48-A) The ASME Code requires a 100% VT-1 examination of the Jet Pump Riser Brace-to-Reactor Vessel Wall Pad welds each 10-year Interval. The BWRVIP requires an EVT-1 baseline examination of 100% of the Jet Pump Riser Brace-to-Reactor Vessel Wall Pad welds in the first 12 years with at least 50% being inspected in the first 6 years. Reinspection consists of 25% during each subsequent 6 year period. BWRVIP-48-A specifically defines the susceptible regions of the attachment that are to be examined. The Code VT-1 examination is conducted to detect discontinuities and imperfections on the surfaces of components, including such conditions as cracks, wear, corrosion, or erosion. The BWRVIP EVT-1 is conducted to detect discontinuities and imperfections on the surface of components and is additionally specified to detect potentially very tight cracks characteristic of fatigue and IGSCC, the relevant degradation mechanisms for these components. General wear, corrosion, or erosion although generally not a concern for inherently tough, corrosion resistant stainless steel material, would also be detected during the process of performing a BWRVIP EVT-1 examination. The ASME Code visual examination method requires (depending on applicable ASME Edition) that a letter character with a height of 0.044 inches can be read. The BWRVIP EVT-1 visual examination method requires the same 0.044 inch resolution on the examination surface and additionally the performance of a cleaning assessment and cleaning as necessary. While the Jet Pump Riser Brace configuration varies depending on the vessel manufacturer, BWRVIP-48-A includes diagrams for each configuration and prescribes examination for each configuration.

NLS2017071 Attachment Page 20 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 The calibration standards used for BWRVIP EVT-1 examinations utilize the same Code characters, thus assuring at least equivalent resolution compared to the Code. Although the BWRVIP examination may be less frequent, it is a more comprehensive method. Therefore, the BWRVIP guidance provides an acceptable level of quality and safety to that provided by the ASMECode. Code Requirement - 813.30 - Interior Attachment Beyond the Beltline Region (B-N-2) The ASME Section XI Code requires a VT-3 examination of accessible Reactor Interior Surface Attachment Welds beyond the beltline each 10-year Interval. In the Boiling Water Reactor, this includes the Core Spray Piping Primary, the Upper Surveillance Specimen Support Bracket Welds-to-Vessel Wall, the Feedwater Sparger Support Bracket Welds-to-Reactor Vessel Wall, the Steam Dryer Support and Hold-Down Bracket Welds-to-Reactor Vessel Wall, the Guide Rod Support Bracket Weld-to-Reactor Vessel Wall, the Shroud Support Plate-to-Vessel Welds, and Shroud Support Gussets. BWRVIP-48-A requires as a minimum the same VT-3 examination method as the Code for some of the interior attachment welds beyond the beltline region, and in some cases specifies an enhanced visual examination technique EVT-1 for these welds. For those interior attachment welds that have the same VT-3 method of examination, the same scope of examination (accessible welds), the same examination frequency (each 10 year interval) and ASME Section XI flaw evaluation criteria, the level of quality and safety provided by the BWRVIP requirements are equivalent to that provided by the ASME Code. The Core Spray Piping Bracket-to-Vessel Attachment Weld is used as an example for comparison between the Code and BWRVIP examination requirements as discussed below: Comparison to BWRVIP Requirements - Core Spray Piping Bracket Welds relative to BWRVIP-48-A The Code examination requirement is a VT-3 examination of each weld every 10 years. The BWRVIP examination requirement is an EVT-1 for the Core Spray Piping Bracket Attachment Welds with each weld examined every four cycles (8 years for units with a 2 year fuel cycle) The BWRVIP examination method EVT-1 has superior flaw detection and sizing capability than the Code VT-3, the examination frequency is greater than the Code requirements, and the same flaw evaluation criteria are used. The Code VT-3 examination is conducted to detect component structural integrity by ensuring the component's general condition is acceptable. An enhanced EVT-1 is conducted to detect discontinuities and imperfections on the examination surfaces, including such conditions as tight cracks caused by IGSCC or fatigue, the relevant degradation mechanisms for BWR internal attachments. Additionally, BWRVIP-48-A guidance requires indications detected by an EVT-1

NLS2017071 Attachment Page 21 of 68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 to be examined by ultrasonics to determine if the indication has propagated into the reactor vessel base material. Therefore, with the EVT-1 examination method, the same examination scope (accessible welds), an increased examination frequency (8 years instead of 10 years) in some cases, and the same flaw evaluation criteria (ASME Code Section XI), the level of quality and safety provided by the BWRVIP criteria is superior to that provided by the ASME Code. Code Requirement - B13.40 - Integrally Welded Core Support Structures (B-N-2) The ASME Code requires a VT-3 examination of accessible surfaces of the welded core support structure each 10-year interval. In the boiling water reactor, the welded core support structure has primarily been considered the shroud support structure, including the shroud support plate (annulus floor), the shroud support ring, the shroud support welds, and the shroud support gussets. In later designs, the shroud itself is considered part of the welded core support structure. Historically, this requirement has been interpreted and satisfied differently across the industry. The proposed alternate examination replaces this ASME requirement with specific BWRVIP guidelines that examine susceptible locations for known relevant degradation mechanisms. The Code requires a VT-3 of accessible surfaces each 10-year interval. The BWRVIP requires as a minimum the same examination method (VT-3) as the Code for integrally welded Core Support Structures, and for specific areas, requires either an enhanced visual examination technique (EVT-1) or volumetric examination (UT). BWRVIP recommended examinations of integrally welded core support structures are focused on the known susceptible areas of this structure, including the welds and associated weld heat affected zones. As a minimum, the same or superior visual examination technique is required for examination at the same frequency as the Code examination requirements. In many locations, the BWRVIP guidelines require a volumetric examination of the susceptible welds at a frequency identical to the Code requirement. For other integrally welded core support structure components, the BWRVIP requires an EVT-1 or UT of core support structures. The core shroud is used as an example for comparison between the Code and BWRVIP examination requirements as shown below. Comparison to BWRVIP Requirements - BWR Core Shroud Examination and Flaw Evaluation Guideline (BWRVIP-76) The Code requires a VT-3 examination of accessible surfaces every 10 years. The BWRVIP requires an EVT-1 examination from the inside and outside surface where accessible or ultrasonic examination of each core shroud circumferential weld that has not been structurally replaced with a shroud repair at a calculated "end of interval" that will vary depending upon the amount of flaws present, but not to exceed ten years.

NLS2017071 Attachment Page 22of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 The BWRVIP recommended examinations specify locations that are known to be vulnerable to BWR relevant degradation mechanisms rather than "all surfaces." The BWRVIP examination methods (EVT-1 or UT) are superior to the Code required VT-3 for flaw detection and characterization. The BWRVIP examination frequency is equivalent to or more frequent than the examination frequency required by the Code. The superior flaw detection and characterization capability, with an equivalent or more frequent examination frequency and the comparable flaw evaluation criteria, results in the BWRVIP criteria providing a level of quality and safety equivalent to or superior to that provided by the Code requirements.

NLS2017071 Attachment Page 23of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Reactor Internals Inspection History Plant: Cooper Nuclear Station Dated: Nov 08, 20 16 (RE29 outage end) Component in BWRVlP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Core Shroud Fall 1995 UT Baseline UT performed on welds H 1 through H7 (RE15) per BWRVIP guidelines. Indications identified in 4 circumferential welds. No examinations on vertical welds. No repair required. Spring 2005 UT UT examinations were performed on welds H-1 (RE22) through H-4 including a portion of vertical weld Vl6. Examination of welds H5-H7 was deferred to fall 2006. Single sided UT examinations were performed on welds H-1 through H-3 with welds H-4 and vertical weld (V-16) receiving dual sided examinations. Percentage of welds examined: H 1 (54.9%), H2 (55.7%), H3 (63.9%), H4 (58.4%). The previously identified eight (8) flaws in HI showed a net decrease in length. No new flaws in H2 were identified. The eight (8) flaws in H3 were reexamined with one (1) new flaw identified for a total increased change in flaw length relative to total weld length of7.5 %. Two (2) new minor flaws were discovered in the HAZ ofH4. In addition, a total of eleven ( 11) minor indications were identified in the base metal adjacent to H4. Six ( 6) of the indications exhibited characteristics associated with Stress Corrosion Cracking (SCC) in areas subjected to cold working during the shroud fabrication/installation process. The remaining five (5) indications did not exhibit characteristics of sec but appeared to exhibit characteristics commonly observed from localized attachment removal sites. The indications were determined to be acceptable by analysis. No indications were observed in the vertical weld. Fall 2006 UT UT examinations were performed on welds H5, (RE23) H6a, H6b, and H7 using phased array. Two- (2) sided examinations were performed on all welds except H7 that received a one-sided UT examination. Coverage was estimated at greater than 72% for welds H5, H6a, and H6b. H7 received greater than 53% coverage. A previously identified indication in H5 was re-examined with no apparent change. A previously identified indication in H6a was re-examined with no

NLS2017071 Attachment Page 24 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection apparent change. A new minor indication was discovered in weld H6b in an area previously scanned in RE 16 (1995). Two (2) new minor indications were discovered in weld H7, one in a previously scanned location and the other in an area not previously scanned. VT-3 VT-3 examination of shroud per ASME Section XI, B-N-2 requirements. Discovered an indication approximately ten (10) inches long behind JP-19. Analyzed as acceptable. Spring 2008 VT-3 Performed first ASME B-N-2 VT-3 successive (RE24) examination of flaw discovered in base metal behind JP-19. No changes in the indication. Spring 2011 VT-3 Performed second ASME B-N-2 VT-3 successive (RE26) examination of flaw discovered in base metal behind JP-19. No changes in the indication. Fall2014 UT UT exams were performed on the HI thru H7 (RE28) welds along with the V 16 and base material flaw behind JP-19. The previously identified indications showed no apparent changes in growth and none were through wall. VT-3 examination of shroud per ASME Section XI, B-N-2 requirements. Also performed third ASME B-N-2 VT-3 successive examination of flaw discovered in base metal behind JP-19. No changes in the indication. Shroud Support/ Access 1993-1995 VT-3 and VT-3 examinations of welds on 50% of core plate Hole Covers UT each outage. No indications. UT of access hole covers (AHC) in 1993. No indications. Spring 1997 VT-3 VT-3 examinations on 50% of the core shroud (RE17) support plate. No indications. VT-1 VT-I examinations of AHC in accordance with GE SIL 462. No indications. Fall 1998 VT-3 VT-3 examinations on 50% of the core shroud (RE18) support plate. No indications. VT-1 VT-1 of AHC's in accordance with GE SIL 462. No indications. VT-1 of gusset plate welds between 0-180° to B-N-2.

NLS201 7071 Attachment Page 25of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Scope Core Spray Piping Date of Frequency of Inspection Spring 2000 (RE19) Fall 2001 (RE20) Spring 2003 (RE21) Spring 2005 (RE22) Fall 2006 (RE23) Spring 2008 (RE24) Fall 2012 (RE27) Fall2014 (RE28) 1980's to 1995 Spring 1997 (REI 7) Inspection Method Used VT-3 VT-1 EVT-1 UT EVT-1 UT EVT-1 EVT-1 EVT-1 UT/EVT-1 VT-lNT-3 UT EVT-1 Summarize the Following Information: Inspection Results, Repairs, Replacements, Re-inspections VT-3 examinations on 50% of the core shroud support plate. No indications. VT-1 examinations of AHCs in accordance with GE SIL 462. No indications. EVT-1 examinations on 17% of the H8 and H9 welds. EVT-1 examinations on 6 gusset welds and AHCs. No indications. UT examination of AHCs. No indications. EVT-1 examinations on four ( 4) gusset welds. No indications. UT examinations on 11. 7% of the H9 weld length. No indications. EVT-1 examinations performed on approximately 16% ofH8 weld length with no relevant indications. EVT-1 examinations of ARC per SIL 462. No indications. EVT-1 examinations performed on accessible lengths of welds on seven (7) gussets. No indications. EVT-1 examinations on 16.7% of the H8 weld. EVT-1 examinations on accessible lengths of welds on two (2) gussets @ 195° and 315°. No indications. UT performed on H9 with 13.4% coverage. EVT-1 performed on both ABC's. No indications. IEB 80-13 examinations of piping and welds in annulus. Three(3) indications identified in Fall 1995 outage by EVT-1. No repair required. UT examinations of CS P8a and P8b welds. Indications on one P8a and one P8b weld (first discovery). Evaluated as acceptable. EVT-1 examinations on balance of piping.

NLS2017071 Attachment Page 26 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Scope Date of Frequency of Inspection Fall 1998 (RE18) Spring 2000 (RE19) Fall 2001 (RE20) Spring 2003 (RE21) Spring 2005 (RE22) Fall 2006 (RE23) Spring 2008 (RE24) Inspection Method Used UT EVT-1 UT EVT-1 UT EVT-1 UT EVT-1 EVT-1 UT EVT-1 EVT-1 Summarize the Following Information: Inspection Results, Repairs, Replacements, Re-inspections UT examinations on the P8a and P8b indications were re-examined. Balance examined by EVT-1. No visual indications. UT examinations on P8a and P8b welds with indications. No repair required. EVT-1 of P3, P4, PS, P6, and P7 welds. No visual indications. UT examinations on P3's, three (3) P4's, PS's, P6's, P7's, P8a's and P8b's. EVT examinations of thirty-one of the CS piping welds. EVT-1 examinations on fifteen (15) welds. Indications re-examined on P8a weld and P8b welds. UT examinations on all P8a and P8b welds. Identified three (3) flaw indications on one P8b weld and one (1) flaw indication on one P8a weld. No change in length. EVT-1 examinations on both junction box covers and accessible portions of both Pl 's, 2 - P2's, 4 - P3's, l-P4a, l-P4b, l-P4c, l-P4d. EVT-1 all P8a and P8b welds. No indications. EVT-1 examinations of both Pl 's. The examination revealed that the P 1 weld is not a creviced weld based on the presence of an external weld on the tee box near the nozzle thermal sleeve. EVT-1 examinations were performed on both P2 welds, the four ( 4) P3 welds, the 4a - 4d welds at 190°, the PS's, P6's, and P7's, the four (4) P8a's, and four (4) P8b's. UT examinations of P8b welds. Previous indications showed no change in size. EVT-1 examinations of piping welds and bracket attachment welds. No new relevant indications observed. EVT-1 of indication near P 1 at 90°. No change. EVT-1 of Pl at 270°. EVT-1 ofP2's and P3's at 90° and 270°. EVT-1 of P4a, -b, -c, and-d at 170° J

NLS2017071 Attachment Page 27of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection EVT-1 ofPS's, P6's, and P7's at 10°, 170°, 190°, and 3S0°. Fall 2009 EVT-1 EVT-1 examinations near P 1 welds at 90° and (RE2S) 270°. No change with the indication near the Pl at 90° (Loop A). EVT-1 examinations of the four (4) P3, PS, P6 and P7 welds, EVT-1 examinations of downcomer welds P4a, P4b, P4c, and P4d at 10°. EVT-1 examinations of four (4) P8a and P8b welds. No change with visual indication of P8b at 10°. UT UT performed on all four (4) P8a and P8b welds. Previously identified indications on the P8a at 190° (Loop B) and the P8b at 10° (Loop A) did not show any change. Spring 2011 EVT-1 EVT-1 of area and indication adjacent to Pl weld (RE26) at 90° (Loop A). No change to the indication. EVT-1 of area adjacent to P 1 weld at 270°. No indications. EVT-1 of the P2 welds at 90° and 270°. EVT-1 of the four (4) P3, PS, P6, and P7 welds. EVT-1 of downcomer welds P4a, P4b, P4c, and P4d at 190°. No indications. Fall2012 EVT-1 EVT-1 of area and indication adjacent to P 1 weld (RE27) at 90° on A Loop. No change to the indication. EVT-1 of the P2, P3a, & P3b @ 90°. EVT-1 of PS, P6, & P7 @ 10° & 170°. No indications. EVT-1 of area adjacent to P 1 weld at 270° on B Loop. No indications. EVT-1 of the P2, P3a, & P3b welds at 270°. EVT-1 of PS, P6, and P7 welds @ 190° & 3S0°. EVT-1 of downcomer welds P4a, P4b, P4c, and P4d @ 3S0°. No indications. Loops A & B, EVT-1 of the bracket attachment welds PB @ 30°, 1S0°, 210°, and 330°. No indications. UT UT performed on all four (4) P8a and P8b welds. Previously identified indications on the P8a at

NLS201 7071 Attachment Page 28 of 68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection 190° (Loop B) and the P8b at 10° (Loop A) did not show any change. Fa112014 EVT-1 Loop A (RE28) EVT-1 of area and indication adjacent to P 1 weld at 90° on A Loop. No change to the indication. EVT-1 of the P2, P3a & P3b welds@ 90°. EVT-1 of P5, P6, & P7 @ 10° & 170°. EVT-1 of downcomer welds P4a, P4b, P4c, and P4d @ 170°. No indications observed. LoopB EVT-1 of area adjacent to Pl weld at 270°. EVT-l of the P2, P3a, & P3b welds at 270°. EVT-l of P5, P6, and P7 welds @ 190° & 350°. No indications observed. Fall 2016 EVT-1 Loop A (RE29) EVT-l of area and indication adjacent to Pl weld at 90° on A Loop. No change to the indication. EVT-l of downcomer welds P4a, P4b, P4c, and P4d at 10°. No indications. EVT-1 of two (2) P8a and two (2) P8b welds at l 0° and 170°. No change with visual indication of P8b at 10°. LoopB EVT-1 of two (2) P8a and two (2) P8b welds at 190° and 350°. No indications. Core Spray Sparger 1980's to 1995 VT-1/UT IEB 80-13 of welds on sparger. No indications. Spring 1997 EVT-1 EVT-1 examinations of sparger welds and brackets (REI 7) per BWRVIP-18. Debris (wire) in C-sparger Nozzle I 5C identified. No other indications. Fall 1998 EVT-1 EVT-1 examinations of sparger welds and brackets (RE18) inspected in accordance with BWRVIP-18. Debris (wire) in C-sparger Nozzle 15C was reconfirmed. No other indications. Spring 2000 EVT-1 EVT-1 examinations of sparger and brackets. (RE19) Five (5) indications evaluated as acceptable.

NLS2017071 Attachment Page 29of68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWR VIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Fall 2001 VT-1 VT-I of25% ofS3a, S3b, and S3c welds. No (RE20) indications. EVT-1 EVT-1 examinations of all S l, S2, and S4 welds examined with no indications. Spring 2003 VT-1 VT-I of25% ofS3a & S3b's and all bracket (RE2 l) welds. No indications. EVT-1 EVT-1 examinations of two S l 's, two S2',s, both XTRW welds near t-boxes, and four (4) S4 welds. No indications. Spring 2005 NIA Sparger examinations deferred to fall 2006 (RE22) (RE23). Fall 2006 VT-1 VT-1 on 50% of the S3a, S3b, and S3c welds and (RE23) l 00% on sparger brackets. No indications. EVT-1 EVT-1 on 100% of SI 's and S2's and S4's. No indications. Spring 2008 VT-I VT-I on 25% of the S3a, S3b, and S3c welds. (RE24) VT-I ofSB's at 90°, 92°, 119°, 149°, 210°, 24I 0 and 268°. EVT-I EVT-1 examinations of S l 's and S2's at 170° and 190°. EVT-1 examinations ofS3a, S3b at 92° to 269°. EVT-I examinations ofS3c at 99°. EVT-1 examinations of S4's at 91 ° and 269°. Fall 2009 VT-1 VT-1on25% of the S3a, S3b, and S3c welds. (RE25) VT-1 ofSB's at 272°, 299°, 30°, 329°, 61 °, 88° and 270°. EVT-1 EVT-1 examinations of S l and S2 and at l 0° and 350°. EVT-1 examinations of two (2) additional welds near the 350° tee-box S2 welds. Spring 2011 VT-I VT-I on 25% of the S3a, S3b, and S3c welds. VT-(RE26) l ofsparger brackets at 90°, 92°, 119°, 149.5°, 210.5°, 241° and 268°. No indications. EVT-1 EVT-1 on C Sparger, SI @ 170°, S2 @ 168° & 172°, S4 @ 9I 0 & 269°. No indications. EVT-1 on D Sparger, Sl @ 190°, S2 @ I88° & 192°, S4 @ 91° & 269°. No indications.

NLS2017071 Attachment Page 30 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Fall 2012 EVT-1 EVT-1 on A sparger, SI @ 10, S2 @ 8° & 12°, (RE27) and S4 @ 89° & 271 °. No indications. EVT-1 on B sparger, SI @ 350°, S2 @ 348° & 352°, XTRW welds near T-box @ 346° & 354°, and S4 @ 89° & 271 °. No indications. VT-I VT-1 on the B sparger, S3a & S3b @ 27 1°-89° and S3c @ 279°. No indications. VT-I of the Sparger brackets at 30.5°, 61°, 88°, 270°, 272°, 299°, and 329.5°. No indications. Fa112014 EVT-1 EVT-1 on C Sparger, Sl @ 170°, S2 @ 168° & (RE28) 172°, S4 @ 91 ° & 269°. No indications observed. EVT-1 on D Sparger, Sl @ 190°, S2 @ 188° & 192°, S4's @ 91° & 269°. No indications observed. VT-1 on 25% of the S3a, S3b, and S3c welds. VT-VT-I I ofsparger brackets (SB) at 90°, 92°, 119°, 149.5°, 210.5°, 241° and 268°. No indications observed. Top Guide (Rim, etc.) 1991-1995 VT VT of top guide beams of fifty (50) cells was performed in 1991 per RICSIL 059. No indications. VT exams of the members in the load path between the top guide and core shroud in 1995 per SIL 588. One (1) indication on the 90° aligner pin keeper was observed and evaluated as acceptable (indication not on load bearing portion of assembly). Spring 1997 VT-I VT-I re-examination of Top Guide Aligner Pin (REI 7) located at 90° in accordance with SIL 588, R 1. Indication on aligner pin keeper did not appear to change in size. Spring 2000 VT-1 VT-1 of two (2) hold down assemblies. No (REl9) indications. Fall2001 VT-1 VT-1 of two (2) horizontal aligner pins with no (RE20) new indications. VT-1 of four (4) hold down assemblies. EVT-1 EVT-1 examinations of accessible areas of the Rim weld.

NLS2017071 Attachment Page 31 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Fall 2006 VT-1 VT-1 on two (2) hold down assemblies and aligner (RE23) pin assemblies at 90° and 270°. A previous indication identified on the non-load bearing keeper of the aligner pin assembly at the 90° location was observed with no apparent change. However, two (2) new but similar type indications were also observed on the same keeper. Three (3) new indications were observed on the non-load bearing aligner pin keeper at the 270° location. Indications were evaluated as acceptable. VT-3 VT-3 examinations performed on accessible areas of top guide per B-N-2. No indications. Spring 2008 VT-I VT-1 examinations performed on hold down and (RE24) aligner assemblies at 0 and 180°. One (1) new indication identified on non-structural keeper at 180°. Similar to indications in keepers seen at 90° and 270°. Evaluated as acceptable. EVT-1 EVT-1 examinations of accessible areas of rim weld. VT-3 VT-3 examinations performed of accessible top guide hold down assemblies, rim pins per B-N-2. Fall 2009 VT-I VT-1 examinations performed on hold down and (RE25) aligner assemblies at 90°. No change in the indication at the 90° aligner pin keeper. EVT-1 EVT-1 examinations of 10% or fourteen (14) of top guide grid beams per BWRVIP-183. No indications. However, only eight (8) were credited as quality examinations. VT-3 VT-3 examinations of accessible areas of top guide per B-N-2. Spring 2011 VT-3 VT-3 of accessible areas of Top Guide per B-N-2. (RE26) No indications. VT-1 VT-1 for BWRVIP-26 credit was performed on the Hold Down assemblies and Aligner Pin assemblies at 270°. An indication not previously reported was observed adjacent to the attachment weld adjoining the Aligner Block to the Top Guide. Indication appears to be a manufacturing remnant that was not completely removed during

NLS2017071 Attachment Page 32 of 68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVlP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection construction. Previously identified indications were also observed with no changes. Scope was expanded to include the remaining other three (3) Aligner Pin assemblies located at 0°, 90°, and 180°. VT-3 for Sect XI B-N-2 and VT-1 for BWRVIP-26 credit was performed. Aligner Pin assembly at 0° was found to have seven (7) previously unidentified indications, with four ( 4) identified in the Aligner Pin Keeper and three (3) identified in the Aligner Block. Review of previous inspection video showed faint presence of indications. Evaluated as acceptable. Aligner Pin assembly at 90° was found to have one (1) previously unidentified indication located on the Aligner Pin Keeper. Review of previous inspection video showed a faint presence of the indication. Three (3) previously identified indications were also observed with no changes. Evaluated as acceptable. Aligner Pin assembly at 180° was found to have two (2) previously unidentified indications located on the Aligner Pin Keeper. Review of previous inspection video shows presence of indications. Three (3) previously identified indications were also observed with no changes. Evaluated as acceptable. EVT-1 EVT-1 examinations of accessible areas of the Rim weld. EVT-1 of two (2) top guide cell locations per BWRVIP-183. No indications. Fall 2012 VT-1 VT-I examinations performed on hold down (RE27) assembly at 180°. No indications. VT-I VT-1 of the aligner pin assembly at 0° was performed to confirm seven (7) flaws identified in RE26. Four (4) of the flaws on the keeper were confirmed and verified to have no changes. One (!)flaw on the aligner pin block was confirmed and verified to have no changes. The two (2) other previously identified flaws on the block were determined to be non-relevant surface scratches.

NLS2017071 Attachment Page 33 of 68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection VT-1 of the aligner pin assembly at 90° was performed to confirm seven (7) flaws identified on the keeper in RE26. 4 of the flaws were confirmed and verified to have no changes. One ( 1) additional flaw on the keeper was also reported. This flaw is similar to flaws seen on the other aligner pin keepers, but could not be verified in previous video due to camera positioning. VT-! of the aligner pin assembly at 180° was performed to confirm three (3) flaws identified in RE26. All of the flaws on the keeper were confirmed and verified to have no changes. VT-1 of the aligner pin assembly at 270° was performed to confirm four (4) flaws identified in RE26. Three (3) of the flaws on the keeper were confirmed and verified to have no changes. One ( l) previously reported flaw adjacent the aligner block to top guide weld was examined using an improved camera and delivery mechanism and determined to be a non-relevant surface scratch. Fa112014 EVT-1 EVT-1 examinations of accessible areas of Rim (RE28) weld. No indications. VT-I VT-1 examinations performed on accessible top portion of the top guide hold down assembly at 0°. No indications. VT-1 of the aligner pin assembly at 0° was performed to confirm five (5) previously identified flaws. Four (4) flaws on the keeper were confirmed to have no changes. The identified flaw on the aligner pin block showed slight increase in length. VT-I of the aligner pin assembly at 90° was performed to confirm five (5) previously identified flaws. The 5 flaws on the keeper were confirmed to have no changes. Five (5) unreported flaws on the aligner block were detected. VT-I of the aligner pin assembly at 180° was performed to confirm three (3) previously identified flaws. The three flaws on the Keeper were confirmed to have no change. Five (5) ~

NLS2017071 Attachment Page 34of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection umeported flaws on the aligner block and two (2) on the top guide were detected. VT-1 of the aligner pin assembly at 270° was performed to confirm three (3) previously identified flaws. The three (3) flaws on the keeper were confirmed and verified to have no changes. One (1) umeported flaw on the aligner block and one (I) on the top guide were detected. EVT-1 of beams near impact site of dropped control rod blade. (Ref OE 313327). No crack indications identified. Fa112016 EVT-1 EVT-1 of five (5) of top guide grid beams per (RE29) BWRVIP-183. No indications. EVT-1 of beams near impact site of dropped control rod blade. (Ref OE 313327). No indications identified. VT-I VT-I of accessible top portion of the TG hold down assembly at 90°. No indications. VT-1/EVT-l VT-1 and EVT-1 of aligner pin assembly at 0° confirmed five (5) previously identified flaws. All flaws showed no changes, except for Flaw 6 on the keeper which appeared longer compared to previous examination but difference was attributed to improved tooling and lighting. VT-I and EVT-1 of aligner pin assembly at 90° confirmed ten (10) previously identified flaws on the keeper and block. All flaws showed no changes except for, Flaw 5 (keeper) and 10 (block) which appeared longer compared to previous exam with difference attributed to improved tooling an lighting. VT-I and EVT-1 of aligner pin assembly at 180° confirmed nine (9) previously identified flaws. All flaws showed no changes, except for Flaws 2 and 3 on keeper which appear longer compared to previous exam with difference attributed to improved tooling and lighting. One(!) new flaw was reported on the block to slider weld that was later confirmed to be present in the previous exam. Change attributed to improved tooling and lighting.

NLS2017071 Attachment Page 35of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection VT-1 and EVT-1 of aligner pin assembly at 270° confirmed five (5) previously identified flaws that showed no changes. One (I) new flaw reported on keeper to washer weld that was later confirmed be present in the previous exam. Core Plate (Rim, etc.) Fall 1995 VT-3 VT-3 examinations of hold down bolts examined in 1995 per SIL 588. No indications. Spring 2000 VT-3* VT-3 examinations of 48 bolts examined from top (RE19) side.

  • (Bolts are not accessible for EVT-1)

Fall 2001 to VT-3 VT-3 examinations performed on accessible areas Fall 2009 (RE20 per B-N-2. No indications. -RE26) Fall 2012 VT-3 VT-3 examination of three (3) hold down bolt (RE27) locations (70, 71, and 72) from the top side. No indications. Fall2014 VT-3 VT-3 exam of36 (50%) hold down bolt locations from the top side. No indications. SLC 1986-2001 VT-2 VT-2 examinations ofSLC penetration during Class l RPV pressure test each outage. Spring 2003 EVT-2 Enhanced VT-2 examinations during Class 1 (RE2 1) pressure test. No indications. Spring 2005 EVT-2/UT Enhanced VT-2 performed of safe-end and (RE22) penetration in conjunction with ASME Section XI Class I pressure test. Manual UT to Appendix VIII performed on nozzle to safe-end weld. No indications. Fall 2006 EVT-2 Enhanced VT-2 examinations of safe-end and (RE23) penetration performed in conjunction with ASME Section XI Class I system leakage test. No indications. Spring 2008 EVT-2 Enhanced VT-2 examinations performed of safe-(RE24) end and penetration in conjunction with ASME Section XI Class I system leakage test. No indications.

NLS2017071 Attachment Page 36of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in B WR VIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Fall 2009 EVT-2 Enhanced VT-2 examinations of safe-end and (RE25) penetration performed in conjunction with ASME Section XI Class I system leakage test. No indications. Spring 2011 EVT-2 Enhanced VT-2 examinations of safe-end and (RE26) penetration performed in conjunction with ASME Section XI Class I system leakage test. No indications. UT examination ofNIO SLC nozzle to safe-end Fall 2012 UT per Risk-Informed ISI Program and Appendix (RE27) VIII. No indications. Enhanced VT-2 examinations of safe-end and EVT-2 penetration performed in conjunction with ASME Section XI Class I system leakage test. No indications. Enhanced VT-2 examinations of safe-end and Fall2014 EVT-2 penetration performed in conjunction with ASME (RE28) Section XI Class I system leakage test. No indications. Jet Pump Assembly 1986-1995 VT-lN T-3/ VT examinations on ten (10) Jet Pumps each UT outage. Exam includes applicable GE SILS. Jet pump beams replaced in 1985. Jet pump beam UT first performed in 1993. Spring 1997 VT-INT-3 Ten (10) jet pumps VT examined. Exam includes (REI7) applicable GE SILs. No indications. Fall 1998 VT -lNT-3 Ten (10) jet pumps VT examined. Exam includes (RE18) applicable GE SILs. No indications. Spring 2000 NIA Examinations deferred to Fall 2001. (REl9) Fall2001 VT-3 VT-3 examinations on all 20 jet pump nozzle (RE20) inlets per SIL 465. No indications. VT-I VT-I examinations on all WD-1 's. No indications. EVT-1 EVT-1 examinations on BB-I and BB-2 on JP's 1-

10. EVT-1 on MX-2's on JP's I - 10. EVT-1 on RB-1 'sand RB-2's on JP's 1/2, 3/4, and 5/6. No indications. EVT-1 on RS-1 's, RS-2's, and RS-3's on JP's 1 - 10. EVT-1 on RS-6's on JP's 1, 3, and

NLS2017071 Attachment Page 37 of 68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection

5. EVT-1 on RS-7's on JP's 2, 4, and 6. EVT-1 on RS-S's and RS-9's on JP's 1/2, 3/4, and 5/6.

No indications. Spring 2003 VT-3 VT-3 examinations on the JP nozzle inlet mixers (RE21) on JP's 11 - 20 per SIL 465. VT-3 examinations of set screws, gaps, and tack welds on JP's I - 20 per SIL 574. No indications. EVT-1 EVT-1 examinations on the IN-4 on JP' s 5, 6, 11, 12, 13, and 14. EVT-1 examinations on the MX-2 on JP's 11, 12, 13, and 14. EVT-1 examinations on the RB-1 'sand RB-2's, on JP's 11/12 and 13/14. EVT-1 examinations on RS-1 and RS-2 on JP's 11/12, 13/14, 15/16, and 17/lS; RS-6 on JP's 11and13; RS-7's on JP's 12 and 14; RS-S 's and RS-9's on JP's 11/12 13/14. No indications. UT UT examinations on the BB-1 'sand BB-2's for JP's I - 20. No indications. Spring 2005 VT-3 VT-3 on the JP nozzle inlet mixers on JP s 1 - 10 (RE22) per SIL 465. No indications. VT-1 VT-1 examinations on JP set screws, gaps and tack welds on JP's 1, 2, 15, and 16 per SIL 574. No indications. EVT-1 EVT-1 examinations on RS-I, RS-2, and RS-3 welds on JP's 1 and 2 and the IN-4 welds on JP's 7, S, 9, and 10. No indications. Fall 2006 VT-1 VT-1 per SIL 574 of adjustment screw and gap (RE23) and tack welds on JPs 9 10. VT-1 ofWD-1 at JP's 9 I 0. No indications. EVT-1 EVT-1 ofRS-1 and RS-2 on JP's 15/1 6 and 19/20. Spring 200S EVT-1 EVT-1 examinations ofIN-4's at JP's 19 and 20. (RE24) EVT-1 examinations ofRB-la's, -lb's, -!e's, and -Id's between JP's 9/ 10 and 19/20. EVT-1 examinations ofRB-2a's, -2b's, -2c's, and -2d's between JP's 9/10 and 19/20. EVT-1 examination ofRS-3 between JP's 19/20. EVT-1 examinations ofRS-6 at JP's 9 and 19. EVT-1 examination of RS-7 at JP's 10 and 20. EVT-1 examinations of RS-Sand RS-9 at JP's 19/20 and 9/10. No indications.

NLS2017071 Attachment Page 38of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection UT UT of BB-I, -2 and -3 on all 20 JP beams. No indications. UT ofMX-2 (and AD-I, AD-2, DF-1, DF-2, DF-3 note in Diffuser Section) on all 20 jet pumps. Fall 2009 VT-3 VT-3 of JP nozzle inlets per SIL 465 on JP's 15, (RE25) 16, 17 and 18. No indications. VT-I VT-1 per SIL 574 of adjustment screw and gap andtackweldsonJPs 10, 15, 16, 19, and20. VT-1 ofWD-1 at JP's 17 and 18. No indications. EVT-1 EVT-1examinations ofIN-4onJP's 15, 16, 17, and 18. EVT-1 examinations ofRB-1 'sand RB-2'sonJP's7/8, 15/16, and 17/1 8. EVT-1 examinations on RS-1 's and RS-2's on JP's 11112 and 17118. EVT-1 examinations on RS-3 's on JP's 11112, 15/16, and 17/18. EVT-1 examinations on RS-6' s on JP' s 7, 15, and 17 and RS-7's on JP's 8, 16, and 18. EVT-1 examinations on RS-8's and RS-9's on JP's 7/8, 15/16, and 17 /1 8. No indications. Spring 2011 VT-3 VT-3 of JP nozzle inlets on JP 9 and 10. No (RE26) indications. VT-1 VT-1 of the JP Restrainer Wedge (WD-1) at JP-I thru JP-20. No indications of movement or wear observed. EVT-1 EVT-1 ofRS-8 and RS-9 on JP-1 thru JP-14, JP-19, and JP-20. No indications. EVT-1 of JP-9 and JP-lO's IN-4, RB-la, RB-lb, RB-le, RB-ld, RB-2a, RB-2b, RB-2c, RB-2d, RS-3, RS-1 RS-2. EVT-1 of JP-9's RS-6 and JP-lO's RS-7. No indications. EVT-1 of JP-7 and JP-8's RS-3. No indications. Fall2012 EVT-1 EVT-1 ofJP-13 and JP-14's IN-4, RB-la, RB-lb, (RE27) RB-le, RB-Id, RB-2a, RB-2b, RB-2c, RB-2d, RS-I, RS-2, & RS-3. EVT-1 ofRS-6 on JP-13 and RS-7 on JP-14. No indications. EVT-1 ofJP-7 and JP-8's RS-3. No indications. EVT-1 ofJP-15 and 16's RS-3. No indications.

NLS2017071 Attachment Page 39 of 68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Scope Date of Frequency of Inspection Fall 2014 (RE28) Fall 2016 (RE29) Inspection Method Used VT-1 VT-3 EVT-1 VT-1 VT-3 EVT-1 Summarize the Following Information: Inspection Results, Repairs, Replacements, Re-inspections VT-1 of the JP Restrainer Wedge (WD-1) at JP-1, 2, 9, 10, 13, 14, 15, 16, 19, & 20. No indications of movement or wear observed. VT-1 of the JP-15 set screw gaps and slip joint. Previously identified shroud side gap was found to have an increase of0.003" with no signs of movement. Vessel side set screw confirmed to have partial contact. No indications on slip joint. VT-1 of the JP-20 set screw gaps and slip joint. Previously identified shroud side gap was found to have an increase of.004" with no signs of movement. Newly reported vessel side set screw gap measured to be.013". No indications on slip joint. VT-3 of JP nozzle inlets on JP-13 and 14. No indications. EVT-1 ofMX-2 on Jet Pumps 1, 2, 8, 9, & 10. No Indications. EVT-1 of JP-1 and JP-2's IN-4, RB-1 a, RB-1 b, RB-le, RB-ld, RB-2a, RB-2b, RB-2c, RB-2d, RS-1, RS-2, RS-3, RS-6 on JP-1 and RS-7 on JP-2. No indications. VT-1 of the JP Restrainer Wedge (WD-1) at JP-1 thru JP-20. No indications of movement or wear observed. VT-1 of the set screws and auxiliary wedges on Jet Pump 1, 2, 9, &10. JPlO had a previously identified shroud side gap that was found to be 0.011" with no signs of movement. JPs 1, 2, and 9 set screws and aux wedges were found to be in full contact with no signs of wear. VT-3 of JP nozzle inlets on JP-I and 2. No indications. EVT-1 ofMX-2 and IN-4 on JP-6. No indications. EVT-1 ofRS-1, RS-2, and RS-3 on JP-3&JP-4 and RS-1 and RS-2 on JP-7&JP-8. No indications. EVT-1 ofJP-5&JP-6's RB-la, RB-lb, RB-le, RB-ld, RB-2a, RB-2b, RB-2c, RB-2d, RS-1, RS-2,

NLS2017071 Attachment Page 40of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWR VIP Scope Jet Pump Diffuser Date of Frequency of Inspection 1986-1998 Spring 1997 (REI 7) Fall 1998 (RE18) Spring 2000 (RE19) Fall 2001 (RE20) Spring 2003 (RE21) Spring 2005 (RE22) Fall 2006 (RE23) Inspection Method Used VT-! VT-3 VT-3 VT-lNT-3 VT-lNT-3 NIA EVT-1 VT-3 VT-1 EVT-1 VT-3 VT-1 EVT-1 Summarize the Following Information: Inspection Results, Repairs, Replacements, Re-inspections RS-3, RS-6, RS-7, RS-8, and RS-9. No indications. VT-1 of set screw gaps and slip joints on JP-15 and JP-20. No indications. VT-1 of the JP Restrainer Wedge (WD-1) at JP-5 and JP-6. No indications. VT-3 of JP nozzle inlets on JP-6. No indications. 10 Jet Pumps VT-3 examined each outage. No indications. No indications. Ten jet pumps VT examined. Exam includes applicable GE SILs. No indications. VT examinations on ten (10) jet pumps. Exam includes applicable GE SILs. No indications. Exams deferred to Fall 2001. EVT-1 examinations on ten (10) jet pumps (5 assemblies). Identified an indication thought to be a broken jet pump sensing line upper bracket retaining weld. Evaluated as acceptable. VT-3 on JP sensing lines for all jet pumps per SIL 420. No indications. VT-1 on sensing line brackets for all jet pumps per SIL 420. Previously reported cracked bracket weld was determined not to be cracked. No indications. EVT-1 examinations of AD-I, AD-2, AD-3a, AD-3b welds on JP's 11 through 20. No indications. VT-3 on JP sensing lines for JP's 1 - 11 and 14 per SIL 420. No indications. VT-1 on JP sensing line brackets for JP's 1-11 and 14. No indications. EVT-1 on AD-1 on JP's l, 2, and 5. EVT-1 examinations on AD-2, AD-3a, AD-3b, DF-1 on

NLS2017071 Attachment Page 41of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection JP-15, 16, 17, 18, 19, and20andDF-2onJP's 15, 16, 19, and 20. No indications. Spring 2008 UT UT on AD-1, AD-2, DF-1, DF-2, and DF-3 (and (RE24) MX-2). One (1) indication on DF-1 at JP-14. EVT-1 EVT-1 examinations on DF-1 at JP-14 in addition to UT. Appeared to be a defect from original construction. Fall 2009 EVT-1 EVT-1 examinations of indication to DF-1 on JP-(RE25) 14 identified during the previous outage. No change. Spring 2011 EVT-1 EVT-1 re-examination of indication located on the (RE26) inside surface of JP-14 at the DF-1 weld. Indication was found to have no changes. Fall2012 EVT-1 EVT-1 re-examination of indication located on the (RE27) inside surface of JP-14 at the DF-1 weld. Indication did not change. Fall2014 EVT-1 EVT-1 of AD-1, AD-2, AD-3a, AD-3b, DF-1, DF-(RE28) 2 on Jet Pumps 1, 2, 8, 9, & 10. No Indications. EVT-1 re-examination of indication located on the inside surface of JP-14 at the DF-1 weld. Indication did not change. Fall 2016 EVT-1 EVT-1 of AD-I, AD-2, AD-3a, AD-3b, DF-2 on (RE29) Jet Pumps 3, 4, 5, 6, & 7. No indications. EVT-1 ofDF-1 (outside diameter) on Jet Pumps 6 and 14. No indications. EVT-1 ofDF-1 (inside diameter) for re-examination of indication on the inside surface of JP-14. Indication showed no change. CRD Guide Tube Fall 1995 VT-3 VT-3 exams of accessible guide tubes. No indications. Spring 1997 VT-3 VT-3 exams of accessible guide tubes. No (RE17) indications. Fall 1998 VT-3 VT-3 exams of accessible guide tubes. No (RE I8) indications.

NLS2017071 Attachment Page 42 of68 10 CFR 50.55a Request No. RIS-02, Revision 1 (continued) Implementation ofBWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Spring 2000 VT-3 VT-3 examinations of eighteen {18) anti-rotation (RE19) pins and eleven ( 11) CRGT-1 welds. No indications. EVT-1 EVT-1 examinations of four (4) CRGT-2 and CRGT-3 welds. No indications. Fall 2001 VT-3 VT-3 examinations of thirteen {13) anti-rotation {RE20) pins and thirteen (13) CRGT-1 welds. No indications. EVT-1 EVT-1 examinations of five (5) CRGT-2 and CRGT-3 welds. No indications. Spring 2005 EVT-1 EVT-1 examinations ofone (1) CRGT-2 weld and (RE22) one (1) CRGT-3 weld. No indications. Fall 2006 EVT-1 EVT-1 examinations ofone (1) CRGT-2 weld and (RE23) one (1) CRGT-3 weld. No indications. Spring 2008 EVT-1 EVT-1 examinations of two (2) CRGT-2 welds (RE24) and three (3) CRGT-3 welds. No indications. Fall 2009 EVT-1 EVT-1 examinations on one (1) CRGT-2 weld and (RE25) two (2) CRGT-3 welds. No indications. CRD Stub Tube NIA NIA No record of examination. In-core Housing NA NA No record of examination back to 1996. Dry Tube 1989-1991 VT VT exam in 1989, 1990,and 1991 perSIL409Rl. All dry tubes replaced in 1993. Spring 2005 VT Replaced one {l) dry tube. (RE22) Fall 2012 VT-I VT-I was performed on dry tube locations at 12-(RE27) 09 and 28-25. No indications. Fall 2014 VT-I VT-1 performed on IRM dry tube locations at 20-(RE28) 25 and 36-41. No indication observed. Replaced IRM dry tube at 12-41. Fall 2016 VT-1 VT-I on Dry Tube Locations. IRM 28-33 & 36-(RE29) 09 and SRM 12-33, 20-17, & 36-25. No indications.

NLS2017071 Attachment Page 43of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Instrument Penetrations 1986-2000 VT-2 VT-2 examination performed during RPV system leakage test each outage for all six (6) instrument nozzle penetrations. No indications. Spring 2000 PT PT examination ofN16A instrument penetration (RE19) nozzle to safe-end weld. Fall2001 VT-2 VT-2 examination performed during RPV system (RE20) leakage test. No indications. Spring 2003 VT-2 VT-2 examination performed during RPV system (RE21) leakage test. No indications. Spring 2005 VT-2 VT-2 examination performed during RPV system (RE22) leakage test. No indications. UT UT examination ofN16B nozzle to safe-end per Risk-Informed ISI Program and Appendix VIII. No indications. Fall 2006 VT-2 VT-2 examination performed during RPV system (RE23) leakage test. No indications. Spring 2008 VT-2 VT-2 examination performed during RPV system (RE24) leakage test. No indications. Fall 2009 VT-2 VT-2 examination performed during RPV system (RE25) leakage test. No indications. Spring 2011 VT-2 VT-2 examination performed during RPV system (RE26) leakage test. No indications. Fall 2012 VT-2 VT-2 examination performed during RPV system (RE27) leakage test. No indications. Fall2014 UT UT examination ofN16B nozzle to safe-end per (RE28) Risk-Informed ISI Program and Appendix VIII. No indications. VT-2 VT-2 examination performed during RPV system leakage test. No indications. Fall 2016 VT-2 VT-2 examination performed during RPV system (RE29) leakage test. No indications. Vessel ID Brackets 1986-1995 VT-INT-3 ASME XI VT-3 (non-beltline) and VT-1 (beltline examinations) of jet pump riser brace, dryer, FW Sparger, Core Spray, guide rod, and surveillance

NLS2017071 Attachment Page 44 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu ofB-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection capsule holder brackets performed once per interval. No indications. Spring 1997 VT-lN T-3 VT-lN T-3 ASME Section XI examinations on (RE17) five (5) jet pump riser brackets, FW brackets and welds examined. No indications. Fall 1998 VT-lN T-3 VT-lNT-3 ASME Section XI examinations on (RE 18) five (5) jet pump riser brackets, FW brackets and welds examined. No indications. EVT-1 EVT-1 examinations on four (4) CS bracket attachment welds. No indications. Spring 2000 VT-3 VT-3 examinations of guide rod attachment welds. (RE19) No indications. VT-1 VT-1 on FW sparger brackets. No indications. EVT-1 EVT-1 examinations on CS bracket attachment welds. No indications. Fall2001 EVT-1 EVT-1 examinations on all FW sparger bracket (RE20) attachment welds and all dryer support attachment welds. No indications. Spring 2003 EVT-1 EVT-1 examination of on JP riser brace pad (RE2 1) attachment weld at 150°. No indications. Spring 2005 VT-3 VT-3 examination of steam dryer hold down (RE22) brackets. Fall 2006 EVT-1 EVT-1 of eight (8) FW sparger brackets and four (RE23) (4) CS piping bracket attachment welds. No indications. Spring 2008 VT-3 VT-3 of guide rod attachment welds. No (RE24) indications. EVT-1 EVT-1 examinations of JP riser brace pad attachment welds at 30°, 150°, 210°, 270°, and 330°. EVT-1 examinations of steam dryer support bracket attachment welds at 215° and 325°. No indications. Fall 2009 EVT-1 EVT-1 examinations of JP riser brace pad (RE25) attachment welds at 60°, 90°, and 120°. No indications.

NLS2017071 Attachment Page 45 of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu ofB-N-1 and B-N-2 Component in BWRVIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Spring 2011 EVT-1 EVT-1 of the JP riser brace pad attachment welds, (RE26) JP-RBPAD-ATTWLDS @ 30°. No Indications. Fall 2012 EVT-1 EVT-I of four (4) CS piping bracket attachment (RE27) welds at 30°, I50°, 210°, and 330°. No indications. EVT-I NT-I of JP riser brace pad attachment welds at 270°. No indications. EVT-INT-3 of steam dryer support bracket attachment welds at 2 I 5° and 325°. No indications. VT-I VT-I of surveillance capsule holder brackets at 300°. No indications. VT-3 VT-3 (direct) examination of steam dryer hold down brackets@ 35°, I45°, 215°, and 325°. No indications. Fall 20I4 EVT-I EVT-1 of Riser Brace attachment welds on JP-1 & (RE28) 2 at I50°. No indications. EVT-INT-3 EVT-lN T-3 of steam dryer support bracket attachment welds at 145° and 35°. No indications. VT-I VT-I of surveillance capsule holder brackets at 30° & I20°. No indications. VT-3 VT-3 (direct) examination of steam dryer hold down brackets@35°, 145°, 215°, and 325°. No indications. Fal120 I6 EVT-1 EVT-1 of the JP riser brace pad attachment welds, (RE29) JP-RBPAD-ATTWLDS Lal 90°. No indications. LPCI Coupling NIA NIA Not applicable to this plant. Steam Dryer Fall 200I VT-1 VT-I of twenty four (24) drain channel welds per (RE20) SIL 474. Spring 2003 EVT-I EVT-1 of twenty four (24) drain channel welds per (RE2 1) SIL 474. Spring 2005 VT-1 VT-1 of leveling screws per OE 16110. (RE22)

NLS2017071 Attachment Page 46of68 10 CFR 50.SSa Request No. RIS-02, Revision 1 (continued) Implementation of BWRVIP Documents in Lieu of B-N-1 and B-N-2 Component in BWR VIP Date of Inspection Summarize the Following Information: Inspection Scope Frequency of Method Used Results, Repairs, Replacements, Re-inspections Inspection Fall 2006 VT-I Performed baseline VT-I examinations to (RE23) w/Character BWRVIP-I39 and SIL 644, Rev 2. Re-examined Card five (5) minor indications previously identified per SIL 474 adjacent to several drain channels. Two (2) new indications were observed in a weld adjacent to a drain channel and both tack welds on one (I) lifting lug were observed. The indications were evaluated as acceptable. Fall 2009 VT-I(89) VT-I examinations on seven (7) previously (RE25) identified indications on dryer. With additional cleaning, six ( 6) of the indications disappeared with only one (1) remaining (i.e., the cracked tack welds on one (1) lifting lug - no change in the lifting lug). Fall 20I6 VT-I(89) Performed VT-I examinations to BWRVIP-I39-(RE29) A. Re-examined one (I) previous indication of cracked tack welds on lifting lug @ 145° with no changes. The other three (3) lifting lugs were observed to have similar cracked tacks that were not previously reported. Five (5) Tie Rods were reported to be slightly bent with no broken welds. One (I) additional indication was observed on the lower guide bracket weld at I 80° that extended into the skirt. The indication was arrested with a 5/8th inch Stop-drill hole. No other dryer indications reported. Dissimilar metal welds Spring 2008 UT Automated UT performed on four ( 4) CAT A (RE24) welds per Appendix VIII. Manual UT performed on two (2) CAT A welds. All welds included in Risk-Informed ISI Program. No indications. Spring 2011 UT Manual UT inspection performed on one (1) CAT (RE26) D nozzle to cap weld (CRD Return) per Appendix VIII and Risk-Informed ISI Program. No indications. Fall2014 UT Manual UT inspection performed on three (3). (RE28) CAT A welds per Appendix VIII. All welds included in Risk-Informed ISI Program. No indications. Fall 20I6 UT Automated Phased Array UT performed on one (I) (RE29) CAT D weld and manual UT performed on one (I) CAT A weld. Both welds included in Risk-Informed ISi Program. No indications.

NLS2017071 Attachment Page 47of68 10 CFR 50.55a Request No. RIS-03 Implementation of Code Case N-702 Proposed Alternative in Accordance with 10 CFR 50.55a(z)(l) Acceptable Level of Quality and Safety ASME Code Component(s) Affected Code Class: ASME Section XI Code Class 1 Component Numbers: Various (see Table 1 for detailed list of components) Code

References:

ASME Section XI, 2007 Edition with 2008 Addenda Code Case N-702 Examination Category: 8-D Item Number(s): 83.90 and 83.100

Applicable Code Edition and Addenda

ASME Section XI, 2007 Edition through the 2008 Addenda Applicable ASME Code Requirements Table IWB-2500-1, Examination Category 8 -D, "Full Penetration Welded Nozzles in Vessels" requires a volumetric examination of all nozzles with full penetration welds to the vessel shell (or head) and integrally cast nozzles each 10-year interval. Additionally, for ultrasonic examinations, ASME Section XI, Appendix VIII, "Performance Demonstration for Ultrasonic Examination Systems," is implemented, as required and conditioned by 10 CFR 50.55a(b )(2)(xv). The RPV nozzle-to-vessel welds and inner radii subject to this request are listed below in Table 1: TABLE 1 Identification Description Total Number Minimum Number Number to be examined Nl Recirculation Outlet 2 1 N2 Recirculation Inlet 10 3 N3 Main Steam Outlet 4 1 NS Core Spray 2 1 N6 Head Instrument 2 1 N7 Head Vent 1 1 N8 Jet Pump Instrumentation 2 1

NLS2017071 Attachment Page 48of68

Reason for Request

10 CFR 50.SSa Request No. RIS-03 (continued) Implementation of Code Case N-702 NRC Regulatory Guide 1.14 7 Rev. 17 conditionally accepts the use of Code Case N-702. This code case provides an alternative to performing examination of 100% of the Nozzle-to-Vessel Welds and Inner Radii for Examination Category B-D nozzles with the exception of the Feedwater and CRDRL Nozzles. The alternative is to perform examination of a minimum of 25% of the nozzle inner radii and nozzle-to-shell welds, including at least one nozzle from each system and nominal pipe size, excluding the Feedwater and CRDRL Nozzles. Proposed Alternative and Basis for Use Proposed Alternative Pursuant to 10 CFR 50.55a(z)(l), NPPD requests approval to implement the alternative of Code Case N-702 in lieu of the code required 100% examination of all nozzles identified in Table 1. As an alternative, for the nozzle-to-shell welds and inner radii identified in Table 1, NPPD proposes to examine a minimum of25% of the nozzle-to-vessel welds and inner radius sections, including at least one nozzle from each system and nominal pipe size, in accordance with Code Case N-702. Basis for Use BWRVIP has issued two topical reports: BWRVIP-108, "Technical Basis for the Reduction oflnspection Requirements for the Boiling Water Reactor Nozzle-to-Vessel Shell Welds and Nozzle Blend Radii," EPRI Technical Report 1003557, dated October 2002 (ML023330203). BWRVIP-241, "Probabilistic Fracture Mechanics Evaluation for the Boiling Water Reactor Nozzle-to-Vessel Shell Welds and Nozzle Blend Radii," EPRI Technical Report 1021005, dated October 2010 (ML11119A041). The BWRVIP-108 report contains the technical basis supporting ASME Code Case N-702 "Alternative Requirements for BWR Nozzle Inner Radius and Nozzle-to-Shell Welds" for reducing the inspection of RPV nozzle-to-vessel shell welds and nozzle inner radius areas from 100% to 25% of the nozzles for each nozzle type during each 10-year interval. BWRVIP-241 provides supplemental analyses for BWR RPV recirculation inlet and outlet nozzle-to-shell welds and nozzle inner radii. BWRVIP-241 was submitted to address the limitations and conditions specified in the December 19, 2007, safety evaluation for the BWRVIP-108 report, "BWR Vessel and Internals Project, Technical Basis for the Reduction of

NLS2017071 Attachment Page 49 of68 10 CFR 50.55a Request No. Rl5-03 (continued) Implementation of Code Case N-702 Inspection Requirements for the Boiling Water Reactor Nozzle-to-Vessel Shell Welds and Nozzle Blend Radii." Based on the two evaluations (BWRVIP-241 and BWRVIP-108), the failure probabilities due to a L TOP event at the nozzle blend radius region and the nozzle-to-vessel shell welds for CNS recirculation inlet and outlet nozzles are very low and meet the NRC safety goal. RG 1.14 7, Revision 17 conditionally accepts the use of Code Case N-702 with the following condition "The applicability of Code Case N-702 must be shown by demonstrating that the criteria in Section 5.0 ofNRC Safety Evaluation regarding BWRVIP-108 dated December 18, 2007 (ML073600374) or Section 5.0 ofNRC Safety Evaluation regarding BWRVIP-241 dated April 19, 2013 (ML13071A240) are met." Section 5.0 of the NRC Safety Evaluation for BWRVIP-241 states: "Licensees who plan to request relief from the ASME Code, Section XI requirements for RPV nozzle-to-vessel shell welds and nozzle inner radius sections may reference the BWRVIP-241 report as the technical basis for use of ASME Code Case N-702 as an alternative. However, each licensee should demonstrate the plant-specific applicability of the BWRVIP-241 report to their units in the relief request by demonstrating all of the following:" (1) The maximum RPV heatup/cooldown rate is limited to less than 115°F/hour CNS Technical Specifications Surveillance Requirement 3.4.9.1, Reactor Coolant System heatup and cooldown rates are limited to a maximum of 100°F when averaged over any one hour period and thus meets the requirement of Condition 1. Note: Inputs used in Conditions 2 through 5 representing the CNS configuration are in bold text. Recirculation inlet nozzles (N2) (2) (pr/t)/CRPv _:::: 1.15 p = RPV normal operating pressure (psi) (1020 psig per CNS Technical Specifications 3.4.10 for Reactor Steam Dome Pressure) r = RPV inner radius (inch) (110.375) t = RPV wall thickness (inch) (6.875) CRPY = 19332 (based on the BWRVIP-108 recirculation inlet nozzle/RPV FEM model);

NLS2017071 Attachment Page 50of68 10 CFR 50.55a Request No. RI5-03 (continued) Implementation of Code Case N-702 CNS specific calculations for Condition 2 above: (1020 x 110.375)/6.875)/19332 = 0.85 ~ 1.15 The CNS result is 0.85 and thus meets the requirement of Condition 2 to be~ 1.15. P = RPV normal operating pressure (psi) (1020) r0 = nozzle outer radius (inch) (10.219) ri = nozzle inner radius (inch), (6.188) C OZZLE = 1637 based on the BWRVIP-108 recirculation inlet nozzle/RPV FEM model); CNS specific calculations for Condition 3 above: [1020(10.2192 + 6.1882)/(10.2192 - 6.1882))/1637 = 1.34 ~ 1.47 The CNS result is 1.34 and thus meets the requirement of Condition 3 to be~ 1.47 Recirculation outlet nozzles (Nl) (4) (pr/t)/CRPv :S 1.15 p = RPV normal operating pressure (psi) (1020) r = RPV inner radius (inch) (110.375) t = RPV wall thickness (inch) (6.875) CRPv = 16171 (based on the BWRVIP-108 recirculation outlet nozzle/RPV FEM model); CNS specific calculations for Condition 4 above: (1020 x 110.375)/6.875)/16171 = 1.013 ~ 1.15 The CNS result is 1.013 and thus meets the requirements of Condition 4 to be~ 1.15 P = RPV normal operating pressure (psi) (1020) r0 = nozzle outer radius (inch) (21.656) ri = nozzle inner radius (inch) (12.875) CNoZZLE = 1977 (based on the BWRVIP-108 recirculation outlet nozzle/RPV FEM model).

NLS2017071 Attachment Page 51 of 68 10 CFR 50.55a Request No. RI5-03 (continued) Implementation of Code Case N-702 CNS specific calculation for Condition 5 above: [1020(21.6562 + 12.8752)/(21.6562 - 12.8752))/1977 = 1.08 ~ 1.59 The CNS result is 1.08 and thus meets the requirements of Condition 5 to be ~ 1.59 The analyses for the N2 nozzles in BWRVIP-108 and BWRVIP-241 are based on the assumption that fluence at the nozzles is negligible because the analysis is for the initial 40 years of plant operation and do not address the extended operating period. Based on analysis performed in support of license renewal for CNS, the beltline was re-evaluated for 60 years based on the axial flux profile and the active fuel and nozzle elevations. In 4.2. l "Reactor Vessel Fluence" of the License Renewal Application, it is documented that fluence at the recirculation inlet nozzles (the closest ferritic nozzles to the beltline) will not exceed IE+ 17 n/cm2 during the period of extended operation. Since the LRA, CNS has updated the fluence values using the NRC approved RAMA fluence method in support of the current Pressure Temperature Limits Report. As part of that evaluation, the predicted fluence at 54 EFPY was also determined for the N2 nozzles which support the conclusion of the LRA that the fluence at the recirculation inlet nozzles will not exceed IE+ 17 n/cm2. The plates and welds in the beltline remain the limiting materials for the period of extended operation. Therefore, the fluence assumptions used in BWRVIP-108 and BWRVIP-241 remain valid and are applicable to CNS. The analyses in BWRVIP-108 and BWRVIP-241 were based on predicted fatigue crack growth over the initial licensed operating period and assumed additional fatigue cycles in evaluating fatigue crack growth. CNS is projected to exceed the total number of thermal cycles used in the BWRVIP analysis during the extended operating period. However, the usage factor for the N2 nozzles is expected to remain below 1.0. Previous BWRVIP documents have demonstrated that sec crack growth represents the majority of the crack growth and that crack growth due to additional mechanical/thermal fatigue cycles introduced by the extended operation time is insignificant compared to hypothetical SCC growth. Thus, the amount of thermal cycle driven fatigue crack growth due to the extended operation to 60 years is not a controlling factor in the probability of failure of the BWR reactor vessel nozzles. CNS performed a plant specific probabilistic fracture mechanics to supplement the criteria of Code Case N-702 and BWRVIP-241 in order to demonstrate that the PoF remains acceptable over the period of extended operation. Conservatively assuming zero inspection for the initial 40 years of operation and examination of25% for PEO, the evaluation concluded the average PoF for a L TOP event is 2.92x 10-11 per year (Reference I) for the nozzle inner radius, and <8.33xl0-13 per year (Reference 1) for the nozzle-to-shell weld, both of which are less than the NRC safety goal of 5x I o-6 per year. The examination history for the subject nozzles is included in Table 2.

NLS2017071 Attachment Page 52of68 10 CFR 50.SSa Request No. RIS-03 (continued) Implementation of Code Case N-702 Duration of Proposed Alternative The duration of this request is for the extended license period ending January 18, 2034. Precedents US NRC letter to Entergy, "Pilgrim Nuclear Power Station - Relief Request PRR-50, Use of Alternatives, Implementation of Code Case N-702," dated January 5, 2016 (ADAMS Accession Number ML15338A309). US NRC letter to NPPD, "Cooper Nuclear Station - Request for Relief No. RI-04 for the Fourth 10-Year Inservice Inspection Interval Regarding Inspection of Reactor Vessel Nozzle-to-Vessel Shell Welds," dated October 8, 2010 (ADAMS Accession Number ML102220449). US NRC letter to NPPD, "Cooper Nuclear Station - Relief Request No. RI-08, Revision 0 Applicable to Fourth 10-Year Inservice Inspection Interval," dated May 20, 2015 (ADAMS Accession Number ML15134A242). Reference

1. "ER 2017-027, Review of Structural Integrity Calculations 1400334.301 & 1400334.302 for Code Case N-702 Relief Request, Revision O," (Proprietary) dated June 7, 2017.

NLS20I707I Attachment Page 53of68 Nozzle ID Nozzle-to-Vessel (NV) Inner Radius (IR) NIA (NV) NIA (IR) NIB (NV) NIB (IR) N2A (NV) N2A (IR) N2B (NV) N2B (IR) N2C (NV) N2C (IR) N2D (NV) 10 CFR 50.SSa Request No. RIS-03 (continued) Implementation of Code Case N-702 Table 2 - Nozzle-to-Shell Welds and Nozzle Blend Radii Component Nominal PiQe Last Category Number Item Number System Size (Inches} Examination B-D B3.90 Recirculation 28 I0/20I6 (Outlet) B-D B3.100 Recirculation 28 10/20I6 (Outlet) B-D B3.90 Recirculation 28 OI /2005 (Outlet) B-D B3.100 Recirculation 28 OI /2005 (Outlet) B-D B3.90 Recirculation I2 OI /2005 (Inlet) B-D B3.100 Recirculation I2 04/2011 (Inlet) B-D B3.90 Recirculation I2 01 /2005 (Inlet) B-D B3.100 Recirculation I2 04/20I I (Inlet) B-D B3.90 Recirculation I2 04/201 I (Inlet) B-D B3.100 Recirculation I2 04/201 I (Inlet) B-D B3.90 Recirculation I2 OI /2005 (Inlet) AQQendix Results VIII Exam NRI Yes NRI VT-I NRI Yes NRI MVT-I NRI Yes NRI Yes NRI Yes NRI Yes NRI Yes NRI Yes NRI Yes

NLS2017071 Attachment Page 54of68 Nozzle ID Nozzle-to-Vessel (NV) Inner Radius (IR) N2D (IR) N2E (NV) N2E (IR) N2F (NV) N2F (IR) N2G (NV) N2G (IR) N2H (NV) N2H (IR) N2J (NV) N2J (IR) N2K (NV) Category Number B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D 10 CFR 50.SSa Request No. RIS-03 (continued) Implementation of Code Case N-702 Nominal PiQe Item Number System Size (Inches) B3.100 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) B3.100 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) B3.100 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) B3.100 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) B3.100 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) B3. l 00 Recirculation 12 (Inlet) B3.90 Recirculation 12 (Inlet) Last AQQendix Results Examination VIII Exam 04/2011 NRI Yes 10/2016 NRI Yes 10/2016 NRI Yes 04/2011 NRI Yes 04/2011 NRI Yes 04/2011 NRI Yes 04/2011 NRI Yes 1012016 NRI Yes 10/2016 NRI Yes 04/2011 NRI Yes 04/2011 NRI Yes 10/2016 NRI Yes

NLS2017071 Attachment Page 55of68 Nozzle ID Nozzle-to-Vessel (NV) Inner Radius (IR) N2K (IR) N3A (NV) N3A (IR) N3B (NV) N3B (IR) N3C (NV) N3C (IR) N3D (NV) N3D (IR) N4A(NVi1) N4A (IRi1l N4B CNVil) N4B (1Ri1l N4C CNVil) N4C (IRi1> Category Number B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D 10 CFR 50.55a Request No. RIS-03 (continued) Implementation of Code Case N-702 Nominal Pipe Item Number System Size (Inches) B3.100 Recirculation 12 (Inlet) B3.90 Main Steam 24 B3.100 Main Steam 24 B3.90 Main Steam 24 B3.100 Main Steam 24 B3.90 Main Steam 24 B3.100 Main Steam 24 B3.90 Main Steam 24 B3.100 Main Steam 24 B3.90 Feedwater 12 B3.100 Feedwater 12 B3.90 Feedwater 12 B3.100 Feed water 12 B3.90 Feedwater 12 B3.100 Feedwater 12 Appendix Last Results Examination VIII Exam 10/2016 NRI Yes 10/2016 NRI Yes 09/2016 NRI VT-1 03/2000 NRI NoC3l 0312000 NRI NoC3l 01 12005 NRI Yes 0212005 NRI MVT-1 03/2000 NRI NoC3l 03/2000 NRI NoC3l 10/2014 NRI Yes 10/2014 NRI Yes 10/2014 NRI Yes 10/2014 NRI Yes 10/2014 NRI Yes 10/2014 NRI Yes

~- NLS2017071 Attachment Page 56of68 Nozzle ID Nozzle-to-Vessel (NV) Inner Radius (IR) N4D (NVi1> N4D (IR)<1> N5A (NV) N5A (IR) N58 (NV) N58 (IR) N6A (NV) N6A (IR) N68 (NV) N68 (IR) N7 (NV) N7 (IR) N8A (NV) Category Number 8-D 8-D 8-D 8-D 8-D 8-D 8-D 8-D 8-D 8-D 8-D 8 -D 8-D 10 CFR 50.SSa Request No. RIS-03 (continued) Implementation of Code Case N-702 Nominal Pipe Item Number System Size (Inches} 83.90 Feedwater 12 83.100 Feedwater 12 83.90 Core Spray 10 83.100 Core Spray 10 83.90 Core Spray 10 83.100 Core Spray 10 83.90 Head 6 Instrumentation Head 83.100 Instrumentation 6 Head 83.90 Instrumentation 6 Head 83.100 Instrumentation 6 8 3.90 Head Vent 4 83.100 Head Vent 4 83.90 Jet Pump 4 Instrumentation Last Appendix Results Examination VIII Exam 10/2014 NRI Yes 10/2014 NRI Yes 10/2016 NRI Yes 10/2016 NRI Yes 01/2005 NRI Yes 03/2011 NRI Yes 02/2005 NRI Yes 02/2005 NRI MVT-1 03/2011 NRI Yes 03/2011 NRI MVT-1 03/2011 NRI Yes 03/2011 NRI MVT-1 03/2000 NRI No0 >

NLS2017071 Attachment Page 57of68 Nozzle ID Nozzle-to-Vessel (NV) Inner Radius (IR) N8A (IR) N8B (NV) N8B (IR) N9 <NVi2) N9 (IRi2) Notes: Category Number B-D B-D B-D B-D B-D

1) Code Case N-702 excludes these nozzles.

10 CFR 50.55a Request No. RIS-03 (continued) Implementation of Code Case N-702 Nominal Pi2e Item Number System Size {Inches) B3.100 Jet Pump 4 Instrumentation B3.90 Jet Pump 4 Instrumentation B3.100 Jet Pump 4 Instrumentation B3.90 CRD Return Line 5 B3.100 CRD Return Line 5 Last A22endix Examination Results VIII Exam 03/2000 NRI No(3) 10/2014 NRI Yes 10/2014 NRI Yes 03/2011 NRI Yes 03/2011 NRI Yes

2) CNS CRD Line is capped and as such is no longer the return for CRD. Because N9 is a unique nozzle, it will be examined and an alternative is not being sought for this nozzle.
3) Exams performed prior to adoption of Appendix VIII.

NLS2017071 Attachment Page 58of68 10CFRSO.SSa Request No. RRS-02 Cooper Nuclear Station Request to Use Code Case N-513-4 Proposed Alternative in Accordance with 10 CFR 50.55a(z)(2) Hardship Without a Compensating Increase in Quality and Safety ASME Code Component(s) Affected All ASME, Section XI, Class 2 and 3 piping components that meet the operational and configuration limitations of Code Case N-513-4, paragraphs l(a), l(b), l(c), and l(d) at CNS.

Applicable Code Edition and Addenda

CNS applicable Code for the fifth 10-year ISi interval and the ISI program is the 2007 Edition of Section XI with the 2008 Addenda. CNS fifth interval started April 1, 2016 and ends February 28, 2026. Applicable ASME Code Requirements ASME Code, Section XI, IWC-3120 and IWC-3130 require that flaws exceeding the defined acceptance criteria be corrected by repair/replacement activities or evaluated and accepted by analytical evaluation. ASME Code, Section XI, IWD-3120(b) requires that components exceeding the acceptance standards of IWD-3400 be subject to supplemental examination, or to a repair/replacement activity.

Reason for Request

In accordance with 10 CFR 50.55a(z)(2), NPPD is requesting a proposed alternative from the requirement to perform repair/replacement activities for degraded Class 2 and 3 piping whose maximum operating temperature does not exceed 200° and whose maximum operating pressure does not exceed 275 psig. Moderately degraded piping could require a plant shutdown within the required action statement timeframes to repair observed degradation. Plant shutdown activities result in additional dose and plant risk that would be inappropriate when a degraded condition is demonstrated to retain adequate margin to complete the component's function. The use of an acceptable alternative analysis method in lieu of immediate action for a degraded condition will allow NPPD to perform additional extent of condition examinations on the affected systems while allowing time for safe and orderly long term repair actions if necessary. Actions to remove degraded piping from service could have a detrimental overall risk impact by requiring a plant shutdown, thus requiring use of a system that is in standby during normal operation. Accordingly, compliance with the current code requirements results in a hardship without a compensating increase in the level of quality and safety. ASME Code Case N-513-3 does not allow evaluation of flaws located away from attaching circumferential piping welds that are in elbows, bent pipe, reducers, expanders, and branch tees. ASME Code Case N-513-3 also does not allow evaluation of flaws located in heat exchanger

NLS2017071 Attachment Page 59of68 10CFR50.55a Request No. RRS-02 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 external tubing or piping. ASME Code Case N-513-4 provides guidance for evaluation of flaws in these locations. Proposed Alternative and Basis for Use NPPD is requesting approval to apply ASME Code Case N-513-4, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division l," to the SW System piping that meets the operational and configuration limitations of Code Case N-513-4, paragraphs l(a), l(b), l(c), and l(d). Application of the Code Case will avoid accruing additional personnel radiation exposure and increased plant risk associated with a plant shutdown to comply with the cited Code requirements. The NRC issued GL 90-05 (Reference 1), "Guidance for Performing Temporary Non-Code Repair of ASME Code Class 1, 2, and 3 Piping (Generic Letter 90-05)," to address the acceptability of limited degradation in moderate energy piping. The generic letter defines conditions that would be acceptable to utilize temporary non-code repairs with NRC approval. The ASME recognized that relatively small flaws could remain in service without risk to the structural integrity of a piping system and developed Code Case N-513. NRC approval of Code Case N-513 versions in RG 1.147, "lnservice Inspection Code Case Acceptability, ASME Section XI, Division 1 (Reference 3)," allows temporary acceptance of partial through-wall or through-wall flaws provided all conditions of the Code Case and NRC conditions are met. The temporary acceptance period has historically been the time to the next scheduled refueling outage. The Code Case also requires the Owner to demonstrate system operability due to leakage. The ASME recognized that the limitations in Code Case N-513-3 were preventing needed use in piping components such as elbows, bent pipe, reducers, expanders, and branch tees and external tubing or piping attached to heat exchangers. Code Case N-513-4 was approved by the ASME to expand use on these locations and to revise several other areas of the Code Case., Attachment 1 provides a marked-up N-513-3 version of the Code Case to highlight the changes compared to the NRC approved N-513-3 version. The following provides a high level overview of the Code Case N-513-4 changes: Revised the maximum allowed time of use from no longer than 26 months to the next scheduled refueling outage. Added applicability to piping elbows, bent pipe, reducers, expanders, and branch tees where the flaw is located more than (Rot) 112 from the centerline of the attaching circumferential piping weld. Expanded use to external tubing or piping attached to heat exchangers. Revised to limit the use to liquid systems. Revised to clarify treatment of Service Level load combinations. Revised to address treatment of flaws in austenitic pipe flux welds. _J

NLS2017071 Attachment Page 60of68 10CFRSO.SSa Request No. RRS-02 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 Revised to require minimum wall thickness acceptance criteria to consider longitudinal stress in addition to hoop stress. Other minor editorial changes to improve the clarity of the Code Case. The technical basis for changes in Code Case N-513-4 when compared to NRC approved Code Case N-513-3 is provided in Enclosure 1, Attachment 2. Enclosure 1, Attachment 3 provides additional technical justification for the use of Code Case N-513-4 at CNS. The design basis is considered for each leak and evaluated using the NPPD Operability Evaluation process. The evaluation process must consider requirements or commitments established for the system, continued degradation and potential consequences, operating experience, and engineering judgment. As required by the Code Case, the evaluation process considers but is not limited to system make-up capacity, containment integrity with the leak not isolated, effects on adjacent equipment, and the potential for room flooding. Leakage rate is not typically a good indicator of overall structural stability in moderate energy systems, where the allowable through-wall flaw sizes are often on the order of inches. The periodic inspection interval defined using paragraph 2(e) of Code Case N-513-4 provides evidence that a leaking flaw continues to meet the flaw acceptance criteria and that the flaw growth rate is such that the flaw will not grow to an unacceptable size. The effects ofleakage may impact the operability determination or the plant flooding analyses specified in paragraph l(f). For a leaking flaw, the allowable leakage rate will be determined by dividing the critical leakage rate by a safety factor of four (4). The critical leakage rate is determined as the lowest leakage rate that can be tolerated and may be based on the allowable loss of inventory or the maximum leakage that can be tolerated relative to room flooding, among others. The safety factor of four ( 4) on leakage is based upon Code Case N-705 (Reference 2), which is accepted without condition in RG 1.14 7, Revision 17. Paragraph 2.2( e) of N-705 requires a safety factor of two (2) on flaw size when estimating the flaw size from the leakage rate. This corresponds to a safety factor of four (4) on leakage for nonplanar flaws. Although the use of a safety factor for determination of an unknown flaw is considered conservative when the actual flaw size is known, this approach is deemed acceptable based upon the precedent of Code Case N-705. Note that the alternative herein does not propose to use any portion of Code Case N-705 and that citation of N-705 is intended only to provide technical basis for the safety factor on leakage. During the temporary acceptance period, leaking flaws will be monitored daily as required by paragraph 2(f) of Code Case N-513-4 to confirm the analysis conditions used in the evaluation remain valid. Significant change in the leakage rate is reason to question that the analysis conditions remain valid, and would require re-inspection per paragraph 2(f) of the Code Case. Any re-inspection must be performed in accordance with paragraph 2(a) of the Code Case.

NLS2017071 Attachment Page 61of68 10CFR50.55a Request No. RRS-02 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 The leakage limit provides quantitative measurable limits which ensure the operability of the system and early identification of issues that could erode defense-in-depth and lead to adverse consequences. CNS will follow all requirements of Code Case N-513-4. With regard to augmented examination process as described in Section 5 of the Code Case, a sample size of at least five of the most susceptible and accessible locations shall be examined within 30 days of detecting the original flaw. The intent of this requirement is to identify the extent of condition that exists within similar system piping that could also be susceptible to similar flaws. Specific to the CNS SW Class 3 piping, if a single flaw is identified within 30 days of scheduled volumetric examinations, CNS may take credit for any previous examination if performed prior to identification of the flaw, as a part of the same set of inspections. Credit will be taken for these examinations to meet the requirements of Code Case N-513-4 paragraph 5(a), provided that the examination meets the inspection method requirements of the Code Case and was performed on SW Class 3 piping components, the inspected segments are of the same design and operation, and the inspected segments are considered to be of the most susceptible and accessible locations determined from the engineering evaluation. This is consistent with the augmented examination approach in GL 90-05 as well as previous NRC approved versions ofN-513. In summary, NPPD will apply ASME Code Case N-513-4 in its entirety along with RG 1.147, Revision 17 (or later NRC defined revision as applicable) for evaluation of Class 2 and 3 piping flaws at CNS if Code repairs cannot reasonably be completed within the Technical Specifications required time limit. Code Case N-513-4 utilizes technical evaluation approaches that are based on principals that are accepted in other Code documents already acceptable to the NRC. The application of this Code Case will maintain acceptable structural and leakage integrity while minimizing plant risk and personnel exposure by minimizing the number of plant transients that could be incurred if degradation is required to be repaired based on ASME Section XI acceptance criteria only. Duration of Proposed Alternative The proposed alternative is for use of Code Case N-513-4 for Class 2 and 3 piping and components within the scope of the Code Case and the request herein. A Section XI compliant repair/replacement will be completed prior to exceeding the next scheduled refueling outage or allowable flaw size, whichever comes first. This relief request will be applied for the duration of the fifth 10-year inservice inspection interval. If a flaw is evaluated near the end of the interval and the next refueling outage is in the subsequent interval, the flaw may remain in service under this relief request until the next refueling outage. Precedent US NRC letter to Exelon Generation Company Nuclear Fleet - "... Proposed Alternative to Use ASME Code Case N-513-4," NRC Safety Evaluation dated September 6, 2016 (ML16230A237).

NLS2017071 Attachment Page 62of68 References 10CFR50.55a Request No. RRS-02 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4

1. NRC Generic Letter 90-05, "Guidance for Performing Temporary Non-Code Repair of ASME Code Class 1, 2, and 3 Piping (Generic Letter 90-05)," dated June 15, 1990.
2. ASME Boiler and Pressure Vessel Code, Code Case N-705, "Evaluation Criteria for Temporary Acceptance of Degradation in Moderate Energy Class 2 or 3 Vessels and Tanks Section XI, Division l," dated October 12, 2006.
3. NRC Regulatory Guide 1.147, "lnservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 17," dated August 2014.

NLS2017071 Attachment Page 63 of68 10CFR50.55a Request No. RRS-03 Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure Proposed Alternative in Accordance with 10 CFR 50.55a(z)(2) Hardship Without a Compensating Increase in Quality and Safety ASME Code Component(s) Affected All ASME, Section XI, Class 3 RHRSWB system piping with a maximum operating pressure less than or equal to 490 psig and a maximum operating temperature less than 200°F at the Cooper Nuclear Station (CNS). The RHR and RHRSWB Systems are designed such that RHRSWB operates at a higher pressure than RHR. The RHR and RHRSWB Systems are standby systems that typically operate during testing or plant shutdown. Under this design, if there is an internal leak within a RHR heat exchanger, RHRSWB water, which is raw water from the Missouri River, will leak into the RHR System. The safety objective of the RHRSWB System is to provide cooling to the RHR System without an uncontrolled release of radioactive material to the environment. The RHRSWB System is designed to provide an adequate supply of cooling water to the RHR heat exchangers during postulated accident and transient conditions to remove the design RHR System heat load and at adequate pressure to prevent uncontrolled release of fission products to the environment due to a RHR heat exchanger tube failure. RHRSWB System at CNS has exhibited a history of degradation similar to raw fresh water systems throughout the nuclear industry. Degradation requiring immediate action to address leakage or observed thinning in the system is generally due to localized corrosion mechanisms.

Applicable Code Edition and Addenda

CNS' applicable Code for the fifth 10-year ISi interval and the ISi program is the 2007 Edition of Section XI with the 2008 Addenda. CNS' fifth interval started April 1, 2016 and ends February 28, 2026. Applicable ASME Code Requirements ASME Code, Section XI, IWD-3 l 20(b) requires that components exceeding the acceptance standards of IWD-3400 be subject to supplemental examination, or to a repair/replacement activity.

Reason for Request

In accordance with 10 CFR 50.55a(z)(2), NPPD is requesting a proposed alternative from the requirement to perform repair/replacement activities for degraded RHRSWB piping which has a

NLS2017071 Attachment Page 64 of68 10CFR50.55a Request No. RRS-03 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure maximum operating pressure in excess of275 psig. Moderately degraded piping could require a plant shutdown within the required action statement timeframes to repair observed degradation. Plant shutdown activities result in additional dose and plant risk that would be inappropriate when a degraded condition is demonstrated to retain adequate margin to complete the component's function. The use of an acceptable alternative analysis method in lieu of immediate action for a degraded condition will allow NPPD to perform additional extent of condition examinations on the affected systems while allowing time for safe and orderly long term repair actions if necessary. Actions to remove degraded piping from service could have a detrimental overall risk impact by requiring a plant shutdown, thus requiring use of a system that is in standby during normal operation. Accordingly, compliance with the current code requirements results in a hardship without a compensating increase in the level of quality and safety. ASME Code Case N-513-3 does not allow evaluation of flaws located away from attaching circumferential piping welds that are in elbows, bent pipe, reducers, expanders, and branch tees. ASME Code Case N-513-3 also does not allow evaluation of flaws located in heat exchanger external tubing or piping. ASME Code Case N-513-4 provides guidance for evaluation of flaws in these locations. Proposed Alternative and Basis for Use NPPD is requesting approval to apply ASME Code Case N-513-4, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division l," to the RHRSWB System piping having a maximum operating pressure of 490 psig. The operational and configuration limitations of Code Case N-513-4, paragraphs l(a), l(b), and l(d), shall apply. The maximum operating temperature of 200°F in paragraph l(c) shall also apply. Application of the Code Case will avoid accruing additional personnel radiation exposure and increased plant risk associated with a plant shutdown to comply with the cited Code requirements. The NRC issued Generic Letter 90-05 (Reference 1 ), "Guidance for Performing Temporary Non-Code Repair of ASME Code Class 1, 2, and 3 Piping (Generic Letter 90-05)," to address the acceptability of limited degradation in moderate energy piping. The generic letter defines conditions that would be acceptable to utilize temporary non-code repairs with NRC approval. The ASME recognized that relatively small flaws could remain in service without risk to the structural integrity of a piping system and developed Code Case N-513. NRC approval of Code Case N-513 versions in Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1 (Reference 3)," allows temporary acceptance of partial through-wall or through-wall flaws provided all conditions of the Code Case and NRC conditions are met. The temporary acceptance period has historically been the time to the next scheduled refueling outage. The Code Case also requires the Owner to demonstrate system operability due to leakage.

NLS2017071 Attachment Page 65 of68 10CFRSO.SSa Request No. RRS-03 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure The ASME recognized that the limitations in Code Case N-513-3 were preventing needed use in piping components such as elbows, bent pipe, reducers, expanders, and branch tees and external tubing or piping attached to heat exchangers. Code Case N-513-4 was approved by the ASME to expand use on these locations and to revise several other areas of the Code Case., Attachment 1 provides a marked-up N-513-3 version of the Code Case to highlight the changes compared to the NRC approved N-513-3 version. The following provides a high level overview of the Code Case N-513-4 changes: Revised the maximum allowed time of use from no longer than 26 months to the next scheduled refueling outage. Added applicability to piping elbows, bent pipe, reducers, expanders, and branch tees where the flaw is located more than (Rot) 112 from the centerline of the attaching circumferential piping weld. Expanded use to external tubing or piping attached to heat exchangers. Revised to limit the use to liquid systems. Revised to clarify treatment of Service Level load combinations. Revised to address treatment of flaws in austenitic pipe flux welds. Revised to require minimum wall thickness acceptance criteria to consider longitudinal stress in addition to hoop stress. Other minor editorial changes to improve the clarity of the Code Case. The technical basis for changes in Code Case N-513-4 when compared to NRC approved Code Case N-513-3 is provided in Enclosure 2, Attachment 2. The design basis is considered for each leak and evaluated using the NPPD Operability Evaluation process. The evaluation process must consider requirements or commitments established for the system, continued degradation and potential consequences, operating experience, and engineering judgment. As required by the Code Case, the evaluation process considers but is not limited to system make-up capacity, containment integrity with the leak not isolated, effects on adjacent equipment, and the potential for room flooding. Leakage rate is not typically a good indicator of overall structural stability, where the allowable through-wall flaw sizes are often on the order of inches. The periodic inspection interval defined using paragraph 2( e) of Code Case N-513-4 provides evidence that a leaking flaw continues to meet the flaw acceptance criteria and that the flaw growth rate is such that the flaw will not grow to an unacceptable size. The effects ofleakage may impact the operability determination or the plant flooding analyses specified in paragraph l(f). For a leaking flaw, the allowable leakage rate will be determined by dividing the critical leakage rate by a safety factor of four (4). The critical leakage rate is

NLS2017071 Attachment Page 66of68 10CFR50.55a Request No. RRS-03 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure determined as the lowest leakage rate that can be tolerated and may be based on the allowable loss of inventory or the maximum leakage that can be tolerated relative to room flooding, among others. The safety factor of four (4) on leakage is based upon Code Case N-705 (Reference 2), which is accepted without condition in RG 1.147, Revision 17. Paragraph 2.2(e) ofN-705 requires a safety factor of two (2) on flaw size when estimating the flaw size from the leakage rate. This corresponds to a safety factor of four ( 4) on leakage for nonplanar flaws. Although the use of a safety factor for determination of an unknown flaw is considered conservative when the actual flaw size is known, this approach is deemed acceptable based upon the precedent of Code Case N-705. Note that the alternative herein does not propose to use any portion of Code Case N-705 and that citation of N-705 is intended only to provide technical basis for the safety factor on leakage. During the temporary acceptance period, leaking flaws will be monitored daily as required by paragraph 2(f) of Code Case N-513-4 to confirm the analysis conditions used in the evaluation remain valid. Significant change in the leakage rate is reason to question that the analysis conditions remain valid, and would require re-inspection per paragraph 2(f) of the Code Case. Any re-inspection must be performed in accordance with paragraph 2(a) of the Code Case. The maximum operating pressure of the Class 3 RHRSWB system is 490 psig. The background, history, and effects of using Code Case N-513-4 at a pressure of 490 psig in lieu of the current 275 psig limitation provided in the Code Case are contained in Enclosure 2,. A review of previous NRC submittals identified that the NRC has previously granted specific relief for leaks on high energy systems (see Enclosure 2, Attachment 3). NPPD is seeking relief for general application for limited degradation in the RHRSWB System raw water piping for a maximum operating pressure of 490 psig. Raw water piping degradation is a well understood phenomenon and the evaluation methods in Code Case N-513-4 are widely applied by the industry in raw water piping systems that operate at a pressure less than or equal to 275 psig without incident. The structural aspects of raising the allowable operating pressure to 490 psig were evaluated as discussed in Enclosure 2, Attachment 3. It was determined that Code Case allowable flaw sizes by both the Linear Elastic Fracture Mechanics and branch reinforcement methods used in Code Case N-513-4 were smaller as would be expected. The effects of jet thrust force were evaluated and it was determined there was little difference in force for a 0.50" diameter flaw size at 275 psig versus 490 psig. The study also determined that jet thrust force increases with increasing leakage rate and that it is appropriate to limit the application of this relief request to 490 psig., Attachment 3 provides:

1) A review of relevant NRC approved relief requests
2) A structural integrity evaluation that includes:

Design minimum wall thickness comparison

NLS2017071 Attachment Page 67 of68 10CFR50.55a Request No. RRS-03 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure Code Case N-5 13-4 allowable flaw size comparison Code Case N-51 3-4 cover thickness requirement comparison

3) A jet thrust force evaluation CNS will follow all requirements of Code Case N-513-4. With regard to augmented examination process as described in Section 5 of the Code Case, a sample size of at least five of the most susceptible and accessible locations shall be examined within 30 days of detecting the original flaw. The intent of this requirement is to identify the extent of condition that exists within similar system piping that could also be susceptible to similar flaws. If a single flaw is identified during scheduled volumetric examinations, CNS may take credit for any previous examination if performed within 30 days prior to identification of the flaw, as a part of the same set of inspections. ~redit will be taken for these examinations to meet the requirements of Code Case N-513-4 paragraph 5(a), provided that the examination meets the inspection method requirements of the Code Case and was performed on Class 3 RHRSWB piping, the inspected segments are of the same design and operation, and the inspected segments are considered to be of the most susceptible and accessible locations determined from the engineering evaluation.

However, CNS will increase the number of augmented examinations from 5 to 10 as the RHRSWB system is considered high energy. This is consistent with the augmented examination approach in GL 90-05. This approach adequately meets the intent of the Code Case with respect to augmented examinations. If the Code Case is applied to a leaking flaw in the RHRSWB system, for leakage greater than 5 gpm, the leakage shall be stopped throughout the temporary acceptance period by the use of engineered mechanical clamping designed by NPPD. The engineered mechanical clamping shall be sufficient to withstand the maximum operating pressure and removable such that the frequent periodic inspections defined in paragraph 2( e) of N-513-4 may be performed. In summary, NPPD will apply ASME Code Case N-513-4 and RG 1.147, Revision 17 (or later NRC defined revision as applicable) for evaluation ofRHRSWB piping flaws at CNS if Code repairs cannot reasonably be completed within the Technical Specifications required time limit. NPPD will apply a 490 psig maximum operating pressure in lieu of the 275 psig maximum operating pressure defined in paragraph l(c) of the Code Case. Code Case N-513-4 utilizes technical evaluation approaches that are based on principals that are accepted in other Code documents already acceptable to the NRC. In order to bolster defense-in-depth and avoid adverse consequences as a result of increasing the maximum operating pressure to 490 psig, NPPD is making three additional commitments: Safety factor of 4 applied to leakage limit Augmented inspections increased from 5 to 10 Leakage shall be stopped by the use of engineered mechanical clamp

NLS2017071 Attachment Page 68 of68 10CFR50.55a Request No. RRS-03 (continued) Cooper Nuclear Station Request to Use Code Case N-513-4 at a Higher System Operating Pressure The application of this Code Case, along with the additional commitments above, will maintain acceptable structural and leakage integrity while minimizing plant risk and personnel exposure by minimizing the number of plant transients that could be incurred if degradation is required to be repaired based on ASME Section XI acceptance criteria only. Duration Of Proposed Alternative The proposed alternative is for use of Code Case N-513-4 for Class 3 RHRSWB piping and components within the scope of the Code Case and the request herein. A Section XI compliant repair/replacement will be completed prior to exceeding the next scheduled refueling outage or allowable flaw size, whichever comes first. This relief request will be applied for the duration of the fifth 10-year ISi interval. If a flaw is evaluated near the end of the interval and the next refueling outage is in the subsequent interval, the flaw may remain in service under this relief request until the next refueling outage. Precedents US NRC letter to Exelon Generation Company Nuclear Fleet - "... Proposed Alternative to Use ASME Code Case N-513-4," dated September 6, 2016 (ML16230A237). US NRC letter to "Peach Bottom Atomic Power Station, Units 2 and 3, and Quad Cities Nuclear Power Station, Units l and 2 - Relief from the Requirements of the ASME Code," dated March 19, 2015 (MLl 5043A496). References

1. NRC Generic Letter 90-05, "Guidance for Performing Temporary Non-Code Repair of ASME Code Class 1, 2, and 3 Piping (Generic Letter 90-05)," dated June 15, 1990.
2. ASME Boiler and Pressure Vessel Code, Code Case N-705, "Evaluation Criteria for Temporary Acceptance of Degradation in Moderate Energy Class 2 or 3 Vessels and Tanks Section XI, Division 1," dated October 12, 2006.
3. NRC Regulatory Guide 1.14 7, "lnservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 17," dated August 2014.

NLS2017071 Page 1 of 27 RR5-02, Cooper Nuclear Station Structural Integrity Associates, Inc. Final Code Case N-513-3 Markup for Revision 4 Technical Basis for Proposed Fourth Revision to ASME Code Case N-513 Cooper Nuclear Station Technical Basis for Proposed Alternative to Use ASME Code Case N-513-4 Note: Enclosed report contains 26 pages not counting this cover page. Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 1 of 26 Final Code Case N-513-3 Markup for Revision 4 to 1700405.401.RO 1-1 e Structural Integrity Associates, Inc."'

Record # 12-8-t I Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 2 of 26 CASES OF ASME BOILER AND PRESSURE VESSEL CODE CASE N-513-4~ Approval Date: January 26, 2009 Code Cases will remain available for use until anm1/led by the applicable Standards Committee. Case -513-:!J Evaluation Criteria for Tern porary Acceptance of Flaws in Moderate Energy Class 2 or J Piping Section XI, Division 1 Inquiry: What requirements may be used for temporary acceptance of flaws, including through-wall flaws, in moderate energy Class 2 or 3 piping mcludmµ db...)\\.\\'S. bent nipe. reducer:;;. C'xpandcrs. ~md hrnnch t..:"t!s. without performing a repair/replacement activ ity? Reply: It is the opinion of the Com mittee that the following requirements may be used to accept flaws, including through-wall flaws. in moderate energy Class 2 or 3 piping mduc.lmg e "'"'" h,'nt p1 pc reduca,_ expander>.,mt! hrnnch tel's, without performing a repair/replacement activity for a lim ited time, not exceeding the eYal~et1eR pu1ea a:, d*fu<<a tA tilt> ~t1111e to the next scheJubl reful'lmg,,utaq.c. SCOPE (a) These requirements apply to the ASNIE Section III. SI B3 I. l, and ANSI 831.7 piping, classified by the Owner as Class 2 or 3 that is,1ccesS1ble for mspectwn. The provisions of this Case do not apply to the following: (1) pumps, valves. expansion joints, and heat exchangers c:xc~pt as pronded m rhJ; (2) weld metal of socket welded joints; (3) leakage through a flange joint; (4) threaded connections employing nonstructural seal welds for leakage protection. {IJJ I his r1s,* 111.1' be <mplted l*> heai exchanger ~xtem~I tubm" or ptpmn. pnw1ded tli<* flaw is charact.:nZl<d m accordance with '.:lat and kakage is morutorcd (<;.~)The provisions of this Case apply to Class 2 or 3 piping 111 liyu1d svskms whose maximum operating temperature does not exceed 200°F (93°C) and whose maximum operating pressure does not exceed 275 psig (1.9MPa). (s_it;) The following flaw evaluation criteria are perm ined for pipe and tube mcludmg dhow'. bent rme. reducers. e:-~panders.,ui...i branch tees. The strmeht pipe flaw evaluation criteria are permined for adjoining fittings and flanges to a distance of (Rot).,, from the weld centerline. Draft 15 (05/05/14) 1 c l he l:>![llng,Jes1gn <'.pc.le shall be.1sed u1 J.:ter1111nmg th< stress m<l1ces B. and f3 <md stre" llltl!ns1f!Ci.\\tlVll foctor I for flaw I!\\.du.RtWl1 fo(irnVtn!.!, \\ 'odt> anplicabil1tv 1!1111~ m tenns ~)f ~Pmnone-nt gl:ometrv such ns D,._1um1 ratio 11 the plPlfll..!. Jes1gn f'ode doe' not pro\\lde stress md1ccs. ~ccuon Ill 2004 h.!ttlllJl or lakr Edrnons "d.\\dden<la 111m h,* used 10 define R and B _ (i;i} The provisions of this Case demonstrate the integrity of the item and not the consequences of leakage. It is the responsibility of the Owner to ol*m 'A.tFttl* ) ol*P* "~"AEHiit1 consider"'!S effects of leakage m demonstratm 0 S\\stem oncrnhtl1l\\ aml nl"rfonn mg nlant lloodm~ anal\\"')C'<.;. (t} Th* o\\"Hl>l8EIPA r*netl. 1'~ l.l lA* "I ""llBAUI l*ffi* frr <<h1eh the temrernr<< 0ee*1*tnAee ofle<Fta 11r,* 1Bl!il1'd llm APl e*ce**d*A! 2e ffidAlA.I fn "' tke IAllH.! d1.;ee *01'" cftl" ee11e!1£;e11. 2 PROCEDURE (a) The flaw geometry shall be characterized by volum etric inspection methods or by physical measurement. The full pipe circum ference at the flaw location shaU be inspected to characterize the length and depth of all flaws in the pipe section. (b) Flaw shall be classified as planar or nonplanar. (cl When multiple flaws, including irregular (compound) shape flaws, are detected the interaction and combined area loss of flaws in a given pipe section shall be accounted for in the flaw evaluation. (d) A flaw evaluation shall be performed to determine the conditions for flaw acceptance. Section 3 provides accepted methods for conducting the required analysis. (ei Frequent periodic inspections of no more than 30 day intervals shall be used to detem1ine if flaws are growing and to establish the tim e~___._a t which the detected flaw will reach the allowable size. Alternatively, a flaw growth evaluation may be performed to predict the tim e___,;........, at which the detected flaw wiU grow to the allowable size. The flaw growth analysis shall consider the relevant growth mechanisms such as general corrosion or wastage. fatigue. or stress corrosion cracking. When a flaw growth analysis is used to establish the allowable time for temporary operation, periodic examinations of no more than 90 day intervals shall be conducted to verify the flaw growth analysis predictions. to 1700405.401.RO 1-2 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RRS-02, Cooper Nuclear Station Page 3 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-:!~ (/) For through-wall leaking flaws, leakage shall be a~seffed Ii, momtored daily 'l"Bll<aa"'A< to confirm the analysis conditions used in the evaluation remain valid. (g) If examinations reveal flaw growth rate to be unacceptable, a repair-t>F-_replacement aclt\\ 1t.v shall be performed. (h) Repair--ff.._replacement acti1:itie' shall be performed no later than when the predicted flaw size from either periodic inspection or by flaw growth analysis exceeds the acceptance criteria of 4, or duruuz the next scheduled ~outage, whichever occurs first. Repair~rep lacement act1v1lies shall be in accordance with IWA-4000 er [J\\",\\,l!(I(,), re*1ieetl'.'el). IA J";flit1PA' **HI,\\d*leflRR ~nar IA ll*e 1001.\\adi!flaa; QllB, iA tile ! 0 0! o\\dflel'BR aAd later iA Rfl1FQ811<8 ""llH P" lll'lO. (i) Evaluations and examination shall be documented in accordance with IWA-6300. The Owner shall document the use of this Case on the applicable data report form. 3 FLAW EVALUATION Planar flaws to straight pipe shall be evaluated in accordance with the requirements in 3.1. Nonplanar flaws m straight pipe shall be evaluated in accordance with the requirements in 3.2. Through-wall !law" in elbow-, and bent pipe ohall be evaluated in acwrdance with the regu1rements m 3 3 Tlu*ough-wall flaw' in reducer<. e'IOpander<i. and branch tee' *hall be evaluated in accordance with the regmrements in 3.-1 and 35. re~mectivelv Flaw growth evaluation shall be performed in accordance with the requirements in 3.Q.;. onferrous materials shall be evaluated in accordance with the requirements in 3..:+. For all tlaw evaluaUon; all Scrx1cc Lc,*cl load combu1ations shall be evaluated to determine the mpst li1niting allo\\yable 1ltJV.'.,ize. 3.1 Planar Flaws in Straight Pipe (qi For planar flaws, the flaw shall be bounded by a rectangular or circumferential planar area in accordance with the methods described in Appendix C. IW A-3300 shall be used to determine when multiple proximate flaws are to be evaluated as a single flaw. The geometry of a through-wall planar flaw is shown in Fig. I. (b) For planar flaws in austenitic piping, the evaluation procedure in Appendix C shall be used. Flaw depths up to 1000/o of wall thickness may be evaluated. When through-wall circumferential flaws are evaluated, the f01mulas for evaluation given in C-5320 or C-63'.!0 a<, rnmlicable. of Appendix C may be used, with the flaw depth to thickness ratio, alt, equal to unity. Draft.15 (05/05/14) When through-wall axial flaws are eva luated. the allowable flaw length is: where p = pressure for the loading condition Do = pipe outside diameter Uj = flow stress .s;. =Code specified yield strength tl2!.I:: Z has l>een added to equation (! i. ~ = Code specified ultimate tensile strength and SFm = structural factor on primary membrane stress as specified in C-2622 z load multjpl1ei for ductile tlaw extefbhl!l !equal to Ill \\\\hen u*mg lurnl lc1ad cnteriaJ Material properties at the temperature of interest shall be used. "G' rnROOG$We<O*~ g (c) For planar flaws in ferritic piping, the evaluation procedure of Appendix C shall be used. Flaw depths up to 100% of wall thickness may be evaluated. fllllic depU1 <L 15 detjned to Figures C-4310-1 and C=-1310-;: When through-wall circumferential flaws are evaluated in accordance with C-5300 or C-6300, the flaw depth to thickness ratio, alt, shall be set to unity. When applying the Appendix C screening criteria for through-wall axial flaws, alt shall be set lo unity, and the reference limit load hoop stress, cri. shall be defined as cr,J/1-1,,. When through-wall axial flaws are evaluated in accordance with C-5400 or ('-6400 the allowable length is defined by eqs. (1) through (3), with U1e appropriate structural factors from Appendix C, C-2622 When through-wall flaws are evaluated in accordance with C-7300 or C-7400, the formulas for evaluation given in C-4300 may be used, but with values for Fm, F0

  • and P applicab le to through-wall flaws. Relations for Fm, Fi. and F that take into account flaw shape and pipe geometry (R/I ratio) shall be used. The appendix to this Case provides equations for Fm, Fb, and P for a selected range of Rlt.

Geometry of a through-wall crack is shown in Fig. I. 2 Attachment I to 1700405.401.RO 1-3 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RRS-02, Cooper Nuclear Station Page 4 of 26 CASE (continued) CASES OF ASME BOU,ER AND PRESSURE VESSEL CODE N-513-4.l FIG. 2 SEPARATION REQUIRENENTS FOR ADJACENT THINNED AREAS .r,, - ---'-""'--*-i L.*----*-""-**' L.... - O.HL. 1*1./ 3.2 Nonplanar Flaws in Straight Pipe __fa) The evalmtion shall consider the depth and extent of the affected area md require that the wall thickness exceed t,,,,,, for a distance thal is the greater of 2.5../Rtnom or U...~8 between adjacent thinned regions, where R is the mean radius of the piping item based on nominal wall thickness and Lm,.-.g is the average of the extent of Lm below tm'" for adjacent areas (see Fig. 2). Alternatively, the adjacent thinned regions shall be considered a single thinned region in the evaluation. __fb) For nonplanar flaws, the pipe is acceptable when ~itherl!l.J11l.J!illL!b)(!). or (b)(l) and !bli3l are met. _____{J__I!he remaining pipe thickness (tp) is greater than or e<pJal to the minimum wall thickness tmm: t~ pDp 2(S+ 0.4p) (4) where p = maximum operating pressure al flaw localion S = allowable stress al operating temperature 1-I TI1e remrunmg degraded pipe sectJon meet> the longitudinal stress limits in the de,ign Code for the Illilli1&. ,_.) Ati an altetJtal!ve to ibl!lh\\ltem..r1.d), an evaluation ol tl1e remru11ing ptpe thickness (t,) may be performed as given below. The evalualion procedure is a function of the depth and the extent of the affected area as illustrated in Fig. 3. (:;) When Wm is less than or equal to 0.5 (Rct) 112, where Ro is the outside radius and Wm is defined in Fig. 3, the flaw can be classified as a planar flaw and evaluated in accordance with 3.l(a) through 3.l(c), above. When the above requirement is not satisfied, (.;w shall be met. C..~J When Lm~J is not greater than (Rot.... )112, t.1oc is detennined from Curve 1 of Fig. 4, where Lm~J is Draft 15 (05/05/14) defined in Fig. 3. When the above requirement is not satisfied, (;,..!l.) shall be met (:..:_~) When Lm is less than or equal to 2.65 (Rctmm"f' and tnorn is greater than 1.13 tmm, ta1oc is determined by satisfying both of the following equations: (5) (6) When the above re<pJirements are not satisfied, (~ shall be met. (~_..) When the requirements of (~J. (.;w, md (J<l.!) above are not satisfied, ta1oc is determined from Curve 2 of Fig. 4. In RElelitietL :_. J*all R11.f) llte lallenlll? OftURfietl: ~""th* nemmal f'lf'* l en~11>1<1inal-&..... 1~s re, ~itmg II am all 8u, iee Lt, el B I'""""' l*if'* le..~ (c) When there is through-wall leakage along a portion of the thinned wall, as illustrated in Fig. 5, the flaw may be evaluated by the branch reinforcement method The thinned area including the ilirough-wall opening shall be represented by a circular penetration at the flaw location. Only the portion of the flaw lying within t.,. need be considered as illustrated in Fig. 6. When evaluating multiple flaws in accordance with 3.2(a), only the portions of the flaws contained within todi need be considered. to 1700405.401.RO 1-4 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 5 of 26 CASE (continued) CASES OF ASME BOILERAND PRESSURE VESSEL CODE N-513 -~ FIG. 3 ILLUSTRATION OF NON PLANAR FLAW DUE TO WALL THINNING Axial direction Draft 15 (05105114) to 1700405.401.RO 1-5 l Lmeo Transverse (clrcumferentlall direction Editors Nc*te This Figure 3 u t*. t-e delete :I an.J replaced wdi the F1g11re 3 '" the f *l: **H'tfi<J" page 4 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 6 of 26 CASE (continued) CASES OF AS!\\llE BOILER AND PRESSURE VESSEL CODE N-513-4.} FIG. 3 ILLUSTRATION OF NONPLANAR FLAW DUE TO WALL THINNING 1..m(o)- Axial direction 1 I Transverse Lm! (ti (circumferential) direction ---\\------ FIC. 4 ALLOWABLE WALL THICKNESS AND LENCTH OF LOCALLY THINNED AREA 0 '-----'----L-----'----L----'----------'---__J 0 2 6 7 8 Draft 15 (05105114) 5 Attachment l to 1700405.401.RO 1-6 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 7 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-51J-4J. FIG. 5 ILLUSTRATlON OF THROUGH-WALL NONPLANAR FLAW DUE TO WALL THINNING Axial direction Draft 15 (05105/14) to 1700405.401.RO ( 1-7 Transverse Cclrcumferentlal) direction Editor"s Note 11u' F1gur* 51s to be deleted and replaced with the Furure < on U1e fullowrng page SJ Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 8 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4J FIG. 5 ILLUSTRATION OF THROUGH-WALL NONPLANAR FLAW DUE TO WALL THINNING Through-wall t. / opening t mm +h.. ~~~. ~~ -l...axial-Axial I direction ~l ~ f I Transverse Lcirc (circumferential) l direction Draft 15 (05/05/14) 7 to 1700405.401.RO 1-8 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 9 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-43 The minimum wall thickness, t.,.,. shall be determined by eq. ( 4). For evaluation purposes, the adjusted wall thickness. l.,;1, is a postulated thickness as shown in Fig. 6. The pipe wall thickness is defined as the thickness of the pipe in the non-degraded region as shown in Fig. 6(a). The diameter of the opening is equal to dod; as defined by lo4J as shown in Fig. 6(a). The postulated value for t.,;1 shall be greater than t.,,. and shall not exceed the pipe wall thickness. The lod; value may be varied between Im., and the pipe wall thickness to determine whether there is a combination of t.,;1 and d.,;1 that satisfies the branch reinforcement requirements. The values of lod; and d.d; of Fig. 6(b) shall satisfy: The remaining ligament average thickness, I,,,, over the degraded area bounded by d.,;1 shall satisfy: (l!.9) In ad<l1tl<.m the pr12c secthm mdu<lmg the eyUivalt:nt hole representa11011 shall meet the long!ludmal >tress lllmts 111 the design t 'o<le f('r the Q!J.lli1£... __ If a flaw growth analysis is performed, the growth in flaw dimensions shall consider the degradation mechanisms as relevant to the application. The flaw is acceptable when there is sufficient thickness in the degraded area to provide the required area reinforcement. (d) Alternatively, if there is a through-wall opening along a portion of the thinned wall as illustrated in Fig. 5 the flaw may be evaluated as two independent planar through-wall flaws, one oriented in the axial direction and the other oriented in the circum ferential direction. The minimum wall thickness Im.,, shal l be determined by eq. ( 4). The allowable through-wall lengths in the axial and circumferential directions shall be determined by varying lo4J shown in Fig. 5 from lnom to tm.,. The allowable through-wall flaw lengths based on t.,;1 shall be greater than or equal to the corresponding L""' and L"n (see Fig. 5) as determined from 3. i(a) and 3. l(b) or

3. l(c), as appropriate. The remaining ligament average thickness, t,,,8, over the degraded area bounded by L.,,.,

and Lm, shall satisfy eq. @'). 3.3 Through-wall Flaws in Elhmn and Bent Pipo Through-wall flaws m dbows,mu bent pipe Jtla\\ be (!Valuated lL';tng the strmnht pme Prr..-icc..:dures 11n*t:n m 3 1 or 3 2!d'l JX1.lvidt!d the stresses used m tht! evalunt1on Draft 15 (05/05/14) are ad1u:"ll:d. to th.:count for the f"'C1..m1etn difference$. as d~scnhL'J helL'w \\ltl!maU\\'l: mi::thods mm he used to L-<1lculah.' the stre$ses U'it!<l m t!\\"aluatwn The lwor stress. (f, for elbow and bent pipe cvaluarton sh<lll be. (J. =( pD0 )[ 2R,,.,,,,+R0 sin¢ ]+(~) R,M. ro 21 2(R,,.,., + R 0 sin¢) h'" l ....(£). R,.., dbc>w or bent 01rc bend r.1d1us ¢ c1rcumlerenttal angle defined m F1i:!ure 7 h f1.:,1b1lm d1arnctenst1c .\\ l, re~ultant pnm an b..:ndmg m.... 1m ent I momt!nl vf mert1?1 hased on 1.!ValualKm \\Vall thickness I f,qw1t 1on 9 is only *<[?phcablc for elbows and bent pipe where h " I fht! ;1xml mt!mbrane pressure strt!ss a'f, for t"lhow anJ bent ptpe eva!Uath'Tl shalJ be where B. 1s n prnnan su-es.<:; 1ndt""\\. a~ defined m St~ct10n [fl for the piping item B. shall he egu.11to11 5 t<'r dbm.\\"'i and bent Plpe Th.: a"\\.ial hendin~ :-ar~ss u. fi.1r t*lb<~w and bi::nt pipe ernluat1on shall be <J = R ( D.M * ) (] I I b 21


~~

where /3 1s a prtmarY :;tress mdex as ddmed m Sectton lfl for th\\! 111pulg ttem. Th~ th(!nnnl t!Xnanshm stress_ rJ for dbo\\\\' and hent Dtl'e ernluauon shall he .\\/ <J =i(D,M,) 1: '21


~~

strt!ss Lrll~ns1ficatton fact.0r as defi.nc;<l m tht! di:s1*~n C'<'dl! for the! rmmg item resultant rl1ermal exb'ans10n mom~nt to 1700405.401.RO 1-9 l} Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 10 of26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4~ 3.4 Through-\\\\ull fla"' in Rrd1Jr1'r' and E'l'.pandrr; Through-wall tlaws m rt!... h1cers :md expander..;; mav be ev~luated us1rw* the stramht pme nrocedurc~ g1v~n in 3 l or 3 2(d) provided the stresses used m the .;valuat10n are ad1u~tcd t0 accvunt for th.; geomctn ,ltfferen<;cs '" dcscnbed below Alternative mcth,,J., mav be used h' calculate the stress<" lL'cd 111 c\\*allli1t1,m l'i!! ~ 1lluslrates the reducer anJ exp,mder z.mes discussed below Evaluatton or ilaws m the snrnll end trnns1t1on z0nl! ts ou1s1JI! the scope l*I this "asl.' The hoop str\\!ss. (J,., and axial mt!mbran~ pressure stress."". fc.~r n:duc.;r or expand.;r i:vnluatton shall bl! ___ er,=( P~. )------~1~l~-11 er = B ( pD, l ______ i_,_1-l~\\ I '21 ) where D. ts the small end OJ) for !laws m the small end and the lame end OD for all...thcr llaws The axrnl hendtn>! stress ll. and thennal cxpanston stress, ll,, for reducer or expander ernluathm shall bt* ___ er.= B,( D~* )------'"(~!~'\\ ___ er, = { -D-;M-1_* )-------'-1~!=0* where/ 1s based on the de!Crackd,,,ctwn 3.5 Through-wall Haw~ in Branch fr" Bmnch reinforcement rt!qwn.*ments shall he: met in accordance with the design Cude I l the dest>!n <:ode did rhX rcyuu~ reinforcement for cv8luauon num(">Scs a remforc~menl tl.!g1on i:-; defim:<l as a region of radius D of the brnnch pipe from the center of the branch connect11.m Throue*h-waJl tlaws in branch k"e'> ouL"tdt! of the rC"mforcement region mJv b1..* t!valuatcd usmg the slra11!ht nm~ nr0cedtlft!$ QJ\\*en m 3 1 1.)f 1 ;i(d 1 prond.:<l t.h~ stresses ust!d tn tht' e\\*aluatton are dd1usted IG a~count for the (,.~0mern: differences as dl!s~nhcd bdc>w.\\ltemJllve methods mav be uud r..;. calculate the ' tresses used m,*rnluatton. l\\*aluanon or llaws m the re2mn <'f hran...:h remforcernc.;:nt ls 0uL'>u.lc th~ scop\\.! 1.>f thts \\L,C The hoon '>lre:".':i a.., anJ ~tx:1at m~mbranc pre-ssurt: slrt:ss_ fi. fi..1r hraru.:h lt!<! eralua110n shall l)I;;! Jl!t.enrnnc:d from eg ( 13) and 1..*q (14), respccll\\'dv The outside dmmcta for each,>f these cquatrnns shall be for the branch 0r nm ptpe, 1..l..:pending vn tht! flmv locanon Draft 15 (05/05114) I"ht! axial bending s1rl!ss "

111J thl*rnrnl l'XJ'fms1on s1rl!s
--

rJr for brnnch tel! eraluauon shall he dl'tl.!mHnl.!d from l!Q 15'1 and ~9 1 161 re~m~clJVl.!h 3.~ Flaw Growth Evaluation If a flaw growth analysis is perfonned. the growth analysis shall consider both corrosion and crack-growth mechanisms as relevant to the application. In perfonning a flaw growth analysis, the procedures in C-3000 may be used as guidance. Relevant growth rate mechanisms shall be considered. When stress corrosion cracking (SCC) is active, the following growth rate equation shall be used: ( 114) where da/dt is flaw growth rate in inches/hour, Kmax is the maxim um stress intensity factor under long-tenn steady state conditions in ksi in.0*', ST is a temperature correction factor, and C and n are material constants. For intergranular SCC in austenitic steels, where T ~ 200°F (93°C). c = 1.79 " 10-* Sr = 1 n = 2.16 1 For transgranular SCC in austenitic steels, where T ~ 200°F (93°C). C = l.79x 10-1 Sr = 3.7I x lO" (JO(o.01942 T-12.2'1] n = 2.161 The temperature, T, is the metal temperature in degrees FahrenheiL The flaw growth rate curves for the above SCC growth mechanisms are shown in Figs. 2-7 and.!.<_~. Other growth rate parameters in eq. (J]u) may be used. prov ided they are supported by appropriate data. 3.]4 Nonferrous Materials For nonferrous materials, nonplanar and planar flaws may be evaluated following the general approach of 3. l through 3._<9. For planar flaws in ductile materials, the approach given 111 ' l f'P) ElRH 11fnr

mstcnil1c mpe may be used; otherwise, the approach given n ' I 'a' t1AJ 1 1for fernt1c pm~ should be applied. Structural factors provided in 4 shall be used. It is the responsibility of the evaluator to establish conservative estimates of strength and fracture toughness for the piping material.

9 Attachment l to 1700405.401.RO l-10 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 11 of26 CASE (continued) CASES OF ASME BOU.ER AND PRESSURE VESSEL CODE N-5 J J-4J FIG. 6 ILLUSTRATION OF ADJUSTED WALL THICKNESS AND EQUIVALENT HOLE DIAMETERS T a...>o...:U..~"'-4------+--'""'~...,._,..,.f" l*I ~Justed W II Thlcic.iie O I I I Sltift figure (b) to the rigltt so that dadj r,,,., width lines up with -.--{ figure (a). ~~-!-----------~ ~~~ 1

e--d ~~--.~

~d.i1-l lb) Equtval nt Hole Representation FIG. 7 CIRCUMFERENTIAL ANGLE DEFINED ~ -- - -~-~~~~~~ Orafi 15 (05/05/1 4) 10 to 1700405.401.RO 1-11 e Structural Integrity Associates, Inc.

CASES OF ASME BOILER AND PRESSURE VESSEL CODE FIG. 8 ZONES OF A REDUCER OR EXPANDER GENERAL NOTE: large end transition zone transition zone Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 12 of 26 CASE (continued) N-513-4J. Transit io~ zones &><tend from the point on the ends where the diameter begins to change to the pomt on the central cone where the cone ongle is constant. Draft 15 (05/05/14) 11 to 1700405.401.RO 1-12 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RRS-02, Cooper Nuclear Station Page 13 of26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4.J FIG. ~ FLAW GROWTH RA TE FOR IGSCC IN AUSTENITIC PIPING ,t; ~ i l.(E.02 i~ 1.c:E.ai 0 ~ tJ 1£E,48 IJ:E-Oll I ~ A"'1onHl:i Plpl~ Ts 211C*' I/ / / / I/ / / 10 100 sar... tntw1'1tv FiKIDr,Jr 11<51 ln."'l Dra!l 15 (05/05114) 12 to 1700405.401.RO 1-13 e Structural Integrity Associates, Inc.

CASES OF AS/all! BOILER AND PRl!SSURI! VESSl!L CODI! Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 14 of 26 CA~ (continued) N-513-.U - FIG...1.Q8 FLAW GROWTH RATE FOR TG SC C IN AUST ENIT IC PIPIN G Draft 15 (05/05/l 4) to 1700405.401.RO UE..O 2 Fl AurllW'fUo,..pl"'iJ T< ZD' 1.1£>4 1.CE.44 = T*llJIF 1.CE.47 1.CE..01 1.l'E,.011 I / v v / I T* IOIF L,* to Str11n runsnv F.Jaor, tbl 1n.u 1 1-14 I.; I/ 100 13 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 15 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4J 4 ACCEPTANCE CRITERIA Piping containing a circumferential planar flaw is acceptable for temporary service when flaw evaluation provides a margin using the strucrural factors in Appendix C, C-2621. For ax.ial planar flaws, the structural factors for temporary acceptance are as specified in Appendix C, C-2622. Stra1\\.\\ht *-.J2ipi<.<Ag containing a nonplanar part:::-through-wall flaw is acceptable for temporary service if the remo1nme. "'I"' secl1on meel.s the long1tudmal stress lunw; in the Jesil!n Cc>de for the p1p111g and Ip 2: laio" where 41vc is determined from 3.2(b). Strn1!!ht I

  • !'£~ conta ining a nonplanar through-wall flaw is acceptable for temporary service when the flaw conditions of 3.2(c) or 3.2(d) are satisfied.. \\n dhow or bent ptpe contamtn11 a nonrlanar lhr<lLlh-wall !law IS :1cceptable for kmp,irnrv* service 1f the (Jaw comllllons of 1 1 *Ire sa11sfieu \\ retlutw or l!XPandcr l.mtamm1! n ncmnlanar through-\\wll flnw is acceptable f<>r tcm porarv "'rv1ce 1f the flaw cond!l1nn' Jf 1 4 are ~ausfted \\branch U!e contmnmg ~i n.... mplanar thr<'UZ.h-wnll llaw 1s ncc~pi...1ble ft-,r t~m p\\}faf'v serv1~l! 1f the tJaw cond1t10ns qf 1 'i are satisfied 5

AUGMENTED [;'{ MINATION An augmented volumetric examination or physical measurement to assess degradation of the affected system shall be performed as follows: (a) From the engineering evaluation, the most susceptible locations shall be identified A sample size of at least five of the most susceptible and accessible locations, or. if fewer than five, all susceptible and accessible locations shall be examined within 30 days of detecting the flaw. (b} When a flaw is detected, an additional sample of the same size as defined in S(a) shall be exam ined. (c) This process shall be repeated within 15 days for each successive sample, until no significant flaw is detected or until I 00% of susceptible and accessible locations have been examined. 6 NOMENCLATURE fj. 8, - c i Do F Section I II nnmarv $tr~s$ 111d1ct"s coefficient in the crack growth relationship inside p1rt! dmmt:tcr outside pipe diameter nondimensionaJ stress intensity factor for through-wall ax.ial flaw under hoop stress nondirnensional stress intensity factor for through-wall circum ferential flaw under pipe bending stress Draft 15 (05/05/14) to 1700405.401.RO 1-15 L nondirnensional stress intensity factor for through-wall circumferential !law under membrane stress mom~nt of mcrtrn hA.s~-..1 ('.Jl l.!\\:Rluatirm th.tckne" 1 max.imum stress intensity factor under long term steady state conditions maximum extent of a local thinned area with t < !,10m length of idealized through-wall planar flaw opening in the axial direction of the pipe, as illustrated in Fig. 5 length of idealized through-wall planar flaw opening in the circun1 ferential direction of the pipe. as illustrated in Fig. 5 maximum extent of a local thinned area with I < l.. m axial extent of wall thinning below t,.m circumferential extent of wall thinning belowt.,.in average of the extent of L.. below Imm for adjacent thinned areas L..., maximum extent of thinned area. i M2 bulging factor for axial Oaw .\\./ r~su ltant prunap. hcnJinu mc'ltl~nt Ji rcsu [t,rnt th(!nnal c.!.\\.panshm moment R mean pipe radius fi...,, _ __ c~*l~b~o~w_o=r~b~e=n= l *p~m~e~c~

  • e=n~

k=*r~ h~n"~*~h= e1~1d~n= 1J=11= L' R0 outside pipe radius S allowable stress at operating temperature SFm strucrural factor on primary membrane Sr x,, a c daldI ll £ £,11 n stress coefficient for temperature dependence in the crack growth relationship Code-specified ultiniate tensile strength Code-specified yield strength metal temperature llHL'<..imwn extent of a local thinned area perpendicular to L,., with I < 1,.., minimum distance between thinned areas i andj load mult1pher for du(;lJk 11,1w c,;tens1on flaw depth half crack length flaw growth rate for stress corrosion cracking diameter equivalent circular hole at laa1 diameter of equivalent circular hole at Imm tlex1b1htY charncterht1c

st.res::> mtt"ns1ficat10n factor total crack length = 2c allowable axial through-wall flaw length exponent in the crack growth relationship 14 e

Structural Integrity Associates, Inc.

Attachments 1 - 3 RRS-02, Cooper Nuclear Station Page 16 of26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4.J p maximum operating pressure at flaw location evaluat1<>n wall thickness. sum*und1m! the de,,radcd area to<1, adjusted wall thickness which is varied for evaluation purposes in the evaluation of a through-wall nonplanar flaw t.ioc allowable local thickness for a nonplanar flaw t""'E average remaining wall thickness covering degraded area with through-wall leak bounded by dad; lmu* minimum wall thickness required for pressure loading tnom nominal wall thickness tp minimum remaining wall thickness (.t maxunum c0nc ane.k at the ~!!nk1 of,1 n:duca A. nondimensional half crack length for through-wall axial flaw ¢ ctrcum fcrenual,mgle from elht>w c-r bend .l1illk g .\\:srnl bcndtng srrt.:ss fur pnmarv k'atlm~ a ax1.il thermal expans11._:.n slrcs~ <If material flow stress m, pipe hoop stress due to pressure and hc.!ndmg mom~nt (ft,r elbows md hcnL _.r.!J2£l ff_ A JffltA1ll lE'Re1tudrAAl h 'R ln~g ;tr**, lPr flFllPRi:: lae8iRg w1tl1@ett *~ra ~ tnta1, 1ti aet1a1\\ la2tar <TL reference limit load hoop stress rr, axwl nrt:'\\sure ';lres.s <I7 material yield strength at temperature, as defined in C-4300 '"~ Hiii< I"""' f. r the det,eted 11,,,, = " ta th' 1tlJO oAi'i< flA" >lo.t' IJ~I All t'Hee:~EitAg ~( Rh nrh_; trJm the IAtflAI ,iuee\\ ary aft!" eeAElit1eF1 B half crack angle for through-wa ll circum ferential flaw 7 APPLICABILITY TJ.i. C 1

  • l' Affh if.I* {nm 1"1* 19~' 1'aH1"R " 11.R ti.* u*mror 1*1~5 \\88oR<la, rhrs*ig,h !Re '.)Vl7 b8n1rn I' 1th lRo JO>' '.l.l*Rd* Reference to Appendix C in this Case shall apply to Appendix C of the 2004 Edition ir later ed1uons or addenda. For editions ttf>J..<ir addenda prior to the 2004 Edition, Class 1 pipe flaw -;;aluation procedures may be used for other piping classes. As a matter of definition, the current term "structural factor" is equivalent to the term "safety factor," which is used in earlier editions and addenda.

Draft 1- (05/05/14) J,d1tor s '\\ore [*or.\\ppltcabiltt\\ lndc., 'lpnl1c,1hilit\\ I"> fr\\,_,m I l19h _ \\JJ!!n<l.1 Ul ) I_~.*... ltthm 15 to 1700405.401.RO 1-16 ~Structural Integrity Associates, Inc."'

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 17 of 26 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4.J MANDATORY APPENDIX I RELATIONS FOR Fm, Fb, AND F FOR THROUGH-WALL FLAWS 1-1 DEFINITIONS For through-wall flaws, the crack depth._...La,* will be replaced with half crack length..._ - c.4 in the stress intensity factor equations in C-7300 and C-7400 of Section XI, Appendix C. Also. Q will be set equal to unity in C-7400. 1-2 CIRCUMFERENTIAL FLAWS For a range of R/t between 5 and 20, the following equations for Fm and Fb may be used: Fm = I +Am (Bltr)l.l + Bm (BltrY..' + Cm (B'tr)3-' Fb = I +Ab (8/tr)u + Bb (8/tr)2*1 + Cb ((J;r)u where e = half crack angle = c!R R = mean pipe radius t =~wall thickness and Am = -2.02917 + 1.67763 (Rft) - 0.07987 (Rlt )' + 0.00 176 (R/t'f Bm = 7.09987 - 4.42394 (R!t) + 0.21 036 (Rlt )' - 0. 00463 (RI t)' Cm = 7.7966 1 + 5.16676 (R/t) - 0.24577 (IM)2 + 0.0054 1 (R!t)' Drarr 15 (05/0511 4) Ao = - 3.'.l6543 + 1.52784 (Rft) - 0.072698 (Rlt )' + 0.00160 11 (Rlt'j' Bb = 11.36322 - 3.91412 (Rlt) + 0.18619 (Ric )' - 0.004099 (R!t)3 Cb = - 3.18609 + 3.84763 (Rlt) - 0.18304 (Rli )1 + 0.00403 (R/t)3 Equations for Fm and Fo are accurate for R/t between 5 and 20 and become increasingly conservative for R!t greater than 20. Alternative solutions for Fm and Fb may be used when R/t is greater than 20. l-3 AXIAL FLAWS For internal pressure loading. the following equallon for F may be used: F = I + 0 072449). + 0.6485&' - 0.2327 ;l.3 + O.Q38 I 54 :i.* - 0.0023487 J.' where c = half crack length ). = cl(Rt)112 The equation for F is accurate for :i. between 0 and 5 Alternative solutions for F may be used when ). is greater than 5. 16 to 1700405.401.RO 1-17 e Structural Integrity Associates, Inc. Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 18 of26 Technical Basis for Proposed Fourth Revision to ASME Code Case N-513 to 1700405.401.RO 2-1 e Structural Integrity Associates, Inc.lg

Attachments 1 - 3 RRS-02, Cooper Nuclear Station Page 19 of 26 Proceedings of the ASME 2014 Pressure Vessels & Piping Conference PVP2014 July 20-24, 2014, Anaheim, California, USA PVP2014-28355 TECHNICAL BASIS FOR PROPOSED FOURTH REVISION TO ASME CODE CASE N-51 3 ABSTRACT Robert 0. McGill Structural Integrity Associates San Jose, CA rmcg11l@struct1nt com Russell C. Cipolla lntertek AIM Sunnyvale, CA russell c1oolla@lntertek com Code Case -513 provides evaluation rules and criteria for temporary acceptance of flaws. including through-wall flaws, in moderate energy piping. The application of the Code Case is restricted to moderate energy, Class 2 and 3 systems, so that safety issues regarding short-term, degraded system operation are minimized. The first version of the Code Case was published in 1997. Since then, there have been three revisions to augment and clarify the evaluation requirements and acceptance criteria of the Code Case that have been published by ASME. The technical bases for the original version of the Code Case and the three revisions have been previously published. There is currently work underway to incorporate additional changes to the Code Case and this paper provides the technical basis for the changes proposed in a fourth revision. These changes include addressing !he current condition on !he Code Case acceptance by the US Nuclear Regulatory Comm ission (NRC), clarification of !he Code Case applicability lin1 its and expansion of Code Case scope to additional piping components. New llaw evaluation procedures are given for through-wall flaws in elbows, bent pipe, reducers, expanders and branch tees. Th~e procedures evaluate llaws in the piping components as if in straight pipe by adjusting hoop and axial stresses to account for the geometry differences. These changes and their technical bases are described in this paper. NOMENCLATURE B,, B2 Primary stress index deftned in ASME Section III for the piping item Do Outside diameter l Moment of inertia based on I (degraded section) Mb Resultant primary bending moment to 1700405.40 l.RO 2-2 Guy DeBoo Exelon Generation Company Warrenville, IL guv deboo@exeloncorp.com Eric J. Houston structural Integrity Associates San Jose, CA ehouston@struct1nt com Resultant !hernial expansion moment Elbow or bent pipe bend radius Outside radius Flexibility characteristic Stress intensification factor as defined in the Code of Record for the piping item Maximum operating pressure at flaw location Evaluation thickness Axial bending stress Thermal expansion ;tress Hoop s1ress Axial membrane slress Circumferential angle INTRODUCTION

Background

Code Case N-513-3 [I] (currently approved revision) provides evaluation rules and criteria for the temporary acceptance of llaws, including through-wal l llaws, in moderate energy piping. The provisions of this Code Case are focused on preventing gross failure of the affected pipe for a temporary period. However, it also requires the piping system and adjacent equipment functionality be demonstrated for lost lluid inventory, spray mg and flooding caused by the leakage. The Code Case provides rules for !he evaluation of degraded pipe and tube for a short operating period, with inspection and monitoring requirements of the degraded condition as part of the overall integrity assessment. The application of the Code Case is restricted to moderate energy Class 2 and Class 3 systems, so !hat the safety issues regarding short-term system operation are minimized. Moderate energy piping is deftned as those piping systems where the maximum operating pressure and temperature do not exceed 275 psig ( 1.9 tv!Pa) and 200°F (93°C), respectively. Copyright 0 2014 by AS:NIE e Structural Integrity Associates, Inc.

Currently. the scope of the Code Case is lim ited to straight pipe with some provision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. There have been many instances where through-wall leaks have been observed in pipe components (i.e., elbows. reducers, expanders or branch tees) or bent pipe outside of the current Code Case scope. As a resull utilities are forced into taking alternate actions (e.g., repair, replacement, or making requests for NRC relief) that can be significantly more burdensome without any measurable increase in plant safety. The fourth revision of the Code Case prov ides evaluation rules and criteria for the temporary acceptance of flaws for these instances. In addition. other enhancements are included with the fourth rev is ion as summarized below. Summarv of Code Case N-513-4 Changes The list below summarizes the proposed changes included in Revision 4 of Code Case N-5 13. ote that a brief reason for each change is included in parenthesis. Temporary acceptance period redefined (addresses NRC condition given in Regulatory Guide I 147 ['.!D Flaw evaluation criteria included for elbows, bent pipe. reducers, expanders and branch tees (scope expansion) Allow flaw evaluation of heat exchanger tubing in specific instances (scope expansion) Daily walkdown requirement for through-wal l leaks provides additional flexibility for user implementation (scope expansion) Limit scope to only Ii uid systems (scope clarification) Treatment of Service Level load combinations (scope clarification) Treatment of flaws in austenitic pipe flw< welds (scope clarification) Minim um wall thickness acceptance criteria to consider longitudinal stresses in addition to hoop stress (scope clarification) In addition, several editorial changes to improve the clarity of the Code Case are included. CODE CASE N-513-4 CHANGES AND TECHNICAL BASIS The following subsections provide details regarding each change and their technical basis. Temporarv Acceptance Period -513-3 specifies a temporary acceptance period that could extent out to 26 months. The NRC did not endorse this maximum period length and in the latest revision ofNRC Regulatory Guide 1. 147, placed a condition on N-513-3 stating, **... repair or replacement activity temporarily deferred under the provisions of this Code Case shall be perfonned during the next scheduled outage."' -513-4 addresses this condition by removing the maximum duration limit and stating, "... the following requirements may be used to 1700405.401.RO 2-3 Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 20 of 26 to accept flaws... without perfonning a repair/replacement activity for a limited time. not exceeding the time to the next scheduled refueling outage." Note that the word "'refueling has been added for further clarification regarding the nature and duration of the plant outage. This language is consistent with the introduction of NRC Generic Letter 90-05 [3] which the original N-513 was based. The second paragraph of 90-05 states: "Temporary non-code repairs are applicable until the next scheduled outage exceeding 30 days, but no later than the next scheduled refueling outage."' Flaw Evaluation Criteria for Piping Components and Bent ~ Evaluation and acceptance criteria have been added to 513-4 for flaws in elbows, bent pipe, reducers, expanders and branch tees. A simplified approach has been adopted based on the evaluations and results from the Second International Piping lntegrity Research Group (IPIRG-2) program reported in Reference [ 4]. The flaw evaluation for the piping component is conducted as if in straight pipe by scaling hoop and axial stresses using ASME piping design code stress indices and stress intensification factors to account for the stress variations caused by the geometric differences. In Reference [4], this approach was determ ined to be very conservative by comparing the failure moments predicted using this approach to the measured failure moments from the elbow tests for through-wall circumferential flaws. Details of the simplified approach are given in the following sections. Flaw Evaluation in Elbows and lknt Pipe. Through-wall flaws in elbows and bent pipe may be evaluated using the straight pipe procedures given in N-513-4 provided the stresses used in the evaluation are adjusted to account for geometry differences. The hoop stress for elbow and bent pipe evaluation shall be (Equation 9 of N-513-4): a = ( pD0 ) [ 2R.... + R0 sin¢ ] + (~) R)vl * (9) 21 '.!(R..., + R, sin ¢) h 213 I Equation 9 is only applicable for elbows and bent pipe where h 2: 0. I. The axial membrane pressure stress for elbow and bent pipe evaluation shall be (Equation 10 ofN-513-4): 8 1 shall be equal to 0. 5 for elbows and bent pipe. The axial bending stress for elbow and bent pipe evaluation shall be (Equation 11 of N-5 13-4): ( R0 M, J rr, = B, - I-(10) (1 1) Copyright 0 20 14 by AS.ME e Structural Integrity Associates, Inc.

Note that if the piping design Code of Record does not provide a 82. it may be taken from the ASNIE Section ill, 2004 Edition or later Editions and Addenda. The thermal expansion stress for elbow and bent pipe evaluation shall be (Equation 12 of -513-4): " * = { R.~f,) ( 12) The first term of Equation 9 accounts for the hoop membrane stress variation around the circum l~rence of the elbow (higher at the intrados, lower at the extrados assuming a unifonn wall thickness). The second tenn conservatively accounts for the through-wall bending in the hoop direction that results from elbow ovalization due to in-plane or out-of-plane bending and was taken from Reference [ 5). Equations I 0- 12 are consistent with the piping design by rule approach in ASME Section ill, NC/ND-3600 (6). It is recognized in Reference [ 4) that the simplified flaw evaluation approach may be overly conservative in some instances. Thus, N-513-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. For example, the French have developed a more comprehensive approach in analyzing flaws m cracked elbows. They have implemented finite element analysis based correlations to determine location specific stresses for flaw evaluation. Reference [7) provides additional details. Flaw Evaluation in R educers and Expanders. Through-wall flaws in reducers and expanders may be evaluated using the straight pipe procedures given in N-513-4 prov ided the stresses used in the evaluation are adjusted to account for the geometry differences. Figure 8 of N-5 13-4 illustrates the reducer and expander zones discussed below. Evaluation of flaws in the small end transition zone is outside the scope of -513-4. The hoop stress and axial membrane pressure stress for reducer and expander evaluation shall be: (l3) (14) Note that 0 0 is either the small end OD for the small end or is the large end OD for the large end. For the large end transition zone and central conical section. 0 0 is the large end OD Also. if the piping design Code of Record does not provide a 8 1, it may be taken from the ASNIE Section ill, 2004 Edition or later Editions and Addenda. The axial bending stress and thermal expansion stress for reducer and expander evaluation shall be: _ B (D 0M,) 21 ( 15) to 1700405.401.RO 2-4 CY = i(D.M,) 21 Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 21of26 (16) Equations 13-1 6 are consistent with the piping design by rule approach in ASME Section ill The reducer and expander zones shown in Figure 8 of 1 -5 13-4 are consistent with those shown in Code Case N-597-2 [8]. As with elbows and bent

pipe,

-513-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. .Flaw Evaluation in :Branch Tees. Branch reinforcement requirements shall be met in accordance with the Construction Code. [f the Construction Code did not require reinforcement, a reinforcement region is defined as a region of radius D, of the branch pipe from the center of the branch connection for evaluation purposes. Through-wall flaws in branch tees outside of the reinforcement region may be evaluated using the straight pipe procedures given in N-513-4 provided the stresses used in the evaluation are adjusted as described below to account for the geometry differences. Evaluation of flaws in the region of branch reinforcement is outside the scope of this Case. The hoop stress and axial membrane pressure stress for branch tee evaluation shall be determined from N-513-4 Equation 13 and 14, respectively. The outside diameter for each of these equations shall be for either the branch or run pipe depending on the flaw location. The axial bending stress and thennal expansion stress for branch tee evaluation shall be determined from N-513-4 Equation 15 and 16. respective ly. As discussed previously, Equations 13-16 are consistent with the piping design by rule approach in AS IE Section III. The limitation regarding flaw evaluation within the branch reinforcement region is consistent with guidance given in Code Case N-597-2. As with elbows and bent pipe, N-513-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. Flaw Evaluation of Heat Exchanger Tubing N-513-4 allows for flaw evaluation in heat exchanger tubing provided the flaw can be characterized and the leakage monitored. The technical basis is that knowledge of flaw geometry is needed to evaluate the structural integrity of the tubing containing the flaw. An example application from plant operating experience would be for leaks in nonferrous tubing of air cooling coils. The heat exchangers being of plate-fin design could have tubing accessible for volumetric inspection. Flexibilih

  • in Daily Walkdown Requirement N-513-4 changes the daily walkdown requirement for leaking flaws from ".

leakage shall be observed by daily walkdowns...to**... leakage shall be monitored daily. This change allows for other techniques to be employed in meeting the intent of the requirement instead of only physical walkdowns. Such techniques could include remote visual Copyright 0 20 14 by ASNIE e Structural Integrity Associates, Inc.

equipment or leakage detection systems to determine if leakage rates are changing. Scope Limited to.Liquid Svstems Provisions ofN-513-4 are now specifically lim ited to only liquid systems. The methods ofN-513-4 should not be applied to the piping of air or other compressible fluid systems. T reatment of Service Level Load Combinations N-513-4 now specifica lly requires all Serv ice Level load combinations to be considered in flaw evaluations to determine the most limiting. N-5 13-3 was previously silent as to what Service Level loading to consider. However, this requirement was im plied in prev ious Code Case revisions when it required the use of pipe flaw evaluation procedures specified in the referenced, non-mandatory appendices of ASME Section XI. Appendix C in the 2002 Addenda and later editions and addenda, and Appendix H for ferritic materials in earlier editions, required all operating conditions or Service Levels be evaluated. Treatment of Flaws in Austenitic Pipe Flux Welds A reference to ASME Section XI, Appendix C, C-6320 has been added to paragraph 3.1 (b) to address the instance where a flaw in an austenitic pipe flux weld requires evaluation. Such a flaw would require the use of Elastic Plastic Fracture Mechanics (EPFlvl) criteria instead of Limit Load criteria. Equation 1 ofN-5 13-4 now includes a Z factor to account for this specific application. When the original version ofN-5 13 was developed, Appendix C of AS.tvJE Section XI only included flaw evaluation criteria for austenitic piping. The change from N-513-1 to -2 included the reference changes to the new Appendix C that combined austenitic and ferritic flaw evaluation criteria. The need to reference EPFM criteria for an austenitic tlux weld flaw evaluation was overlooked. Minimum Wall Thickness Acce ptance Criteria In establishing a minimum wall thickness acceptance criteria for paragraphs '.2(b) and 3.2 (c) ofN-513-4. the requirement to consider longirudinal stresses in addition to hoop stress is added. While it is unlikely that a longirudinal stress based minimum wall thickness would be Limiting compared to the hoop stress based minimum wall thickness, the user should be aware of this possibility and confim1 an appropriate Im,. as an acceptance criterion. CONCLUSIONS This docum ent serves as the technical basis for the fourth revision of Code Case -513. This Code Case provides evaluation rules and criteria for temporary acceptance of tlaws, including through-wall flaws, in moderate energy Class 2 or Class 3 piping. Currently, the scope of the Code Case is lim ited to straight pipe with some provision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. N-513-4 provides flaw evaluation rules and criteria for elbows, bent pipe, reducers, expanders to 1700405.401.RO 2-5 Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 22 of 26 and branch tees. In addition, several other scope expansions and clarifications are included as well as editorial improvements. With these changes, it is believed the Code Case will be of even greater use to utilities in avoiding unscheduled plant shutdowns without negatively impacting plant safety. ACKNOWLEDGEMENTS The development of Code Case N-513-4 was through the efforts of the Working Group on Pipe Flaw Evaluation. The authors wish to recognize the efforts of all Working Group members especially the Working Group Chair, Dr. Doug Scarth. REFERENCES ASME Code Case N-513-3, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1," Cases of the ASME Boiler and Pressure Vessel Code, January 26, 2009.

2.

Regulatory Guide 1. 147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1," Revision 16. October 2010.

3.

NRC Generic Letter 90-05, "Guidance for Performing Temporary Non-Code Repair of ASME Code Class I. 2, and 3 Piping," (June 15, 1990).

4.

Kilinski, I, Mohan, R., Rudland, D., Fleming, M., Olson, R., Scott, P., Brust, F, Ghadiali, N., Witkowski, G., and Hopper, A, "Fracture Behavior of Circumferentially Surface-Cracked Elbows," NUREG/CR-6444, BMI-2192, December 1996.

5.

Moore, S.E., and Rodabaugh, E.C., "Background for Changes in the 198 1 Edition of the ASME Nuclear Power Plant Components Code for Controlling Prim ary Loads in Piping Systems," Journal of Pressure Vessel Technology, Volume 104, pp. 351 - 361, November 1982.

6.

ASME Boiler and Pressure Vessel Code, Section III, NC/ND-3600, 2004 Edition.

7.

Marie, S., Chapuliot, S., Kayser, Y., Lac ire, M.H., Drubay, B., Barthe let, B., Le-Dell iou, P, Rougier, V, Naudin, C., Gilles, P., and Triay, M, "French RSE-M and RCC-MR Code Appendices for Flaw Analysis: Presentation of the Fracture Paran1eters Calculation - Part IV: Cracked Elbow," International Journal of Pressure Vessels and Piping 84, pp. 659-686, May 2007.

8.

ASME Code Case N-597-2, "Requirements for Analytical Evaluation of Pipe Wall Thinning, Section XI, Div ision l," Cases of the AS.tvJE Boiler and Pressure Vessel Code, November 18, 2003. Copyright 0 20 14 by ASME l} Structural Integrity Associates, Inc. Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 23 of 26 Cooper Nuclear Station Technical Basis for Proposed Alternative to Use ASME Code Case N-513-4 to 1700405.401.RO 3-1 SJ structural Integrity Associates, Inc."'

BACKGROUND Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 24 of 26 Code Case N-513-4 [1] provides evaluation rules and criteria for the temporary acceptance of flaws, including through-wall flaws, in moderate energy piping. Moderate energy piping is defined as those piping systems where the maximum operating pressure and temperature do not exceed 275 psig and 200°F, respectively. The provisions of the Code Case are focused on preventing gross failure of the affected pipe for a temporary period while permitting leakage within the plant's Technical Specification. The Code Case provides rules for the evaluation of degraded pipe and tube for a short operating period, with inspection and monitoring requirements of the degraded condition as part of the overall integrity assessment. The application of the Code Case is restricted to moderate energy Class 2 and Class 3 systems, so that the safety issues regarding short-term system operation are minimized. The previous Code Case revision, N-513-3 [2], is conditionally approved by the NRC in Regulatory Guide 1.14 7 [3]. The single condition deals with a requirement to perform the repair or replacement activity, temporarily deferred, during the next scheduled outage. Since the introduction of this Code Case, many utilities have used it as a basis for continued operation of degraded piping in moderate energy systems and that has resulted in significantly fewer relief requests to the NRC. Consequently, the industry has benefited from substantial cost savings while maintaining safety. To date, there have been no known instances where the use of the Code Case has resulted in any safety issues at the plants. The scope of Code Case N-513-3 is limited to straight pipe with some provision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. There have been many instances where through-wall leaks have been observed in pipe components (i.e., elbows, reducers, expanders or branch tees) or bent pipe outside of the current Code Case scope. As a result, utilities are forced into taking alternate actions (e.g., repair, replacement or making requests for NRC relief) that can be significantly more burdensome without any measurable increase in plant safety. Code Case N-513-4 provides evaluation rules and criteria for the temporary acceptance of flaws for these instances. In addition, other enhancements are included with the fourth revision as summarized below.

SUMMARY

OF CODE CASE N-513-4 CHANGES The list below summarizes the major differences between the NRC-approved Code Case N-513-3 and Code Case N-513-4. Note that a briefreason for each change is included in parenthesis. Temporary acceptance period redefined from no longer than 26 months to the next refueling outage (addresses NRC condition given in Regulatory Guide 1.14 7) Flaw evaluation criteria included for elbows, bent pipe, reducers, expanders and branch tees (scope expansion) Allow flaw evaluation of heat exchanger tubing in specific instances (scope expansion) Daily walkdown requirement for through-wall leaks provides additional flexibility for user implementation (scope expansion) Limit scope to only liquid systems (scope clarification) Treatment of Service Level load combinations (scope clarification) to 1700405.401.RO 3-2 e Structural Integrity Associates, Inc.

Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 25 of 26 Treatment of flaws in austenitic pipe flux welds (scope clarification) Minimum wall thickness acceptance criteria to consider longitudinal stresses in addition to hoop stress (scope clarification) In addition, several editorial changes to improve the clarity of the Code Case are included. A detailed markup of Code Case N-513-3 showing all of the changes made for Revision 4 is provided in Attachment 1. TECHNICAL BASIS The technical basis for the changes listed above is given in an ASME Pressure Vessel and Piping (PVP) conference paper [4] and is provided in Attachment 2. PRECEDENTS There have been several submittals approved for N-513-4 use in specific applications and for generic use by Exelon [5]. The table below lists several Safety Evaluation Reports as precedents for use of Code Case N-513-4. Table 1: Code Case N-513-4 Precedents SER Accession No. Plant Application Additional Requirements ML16230A237 Exelon Fleet Generic N-513-4 Critical leakage determination MLl 5070A428 ANO Leaking sweepolet 5 gpm leakage limit ML14316Al67 Fort Calhoun Leaking elbow None ML14335A551 Peach Bottom Leaking elbow 5 gpm leakage limit ADDITIONAL REQUIREMENT Consistent with the previous NRC N-513-4 safety evaluation for the Exelon fleet Relief Request [5], the following limitation on leakage is included. For a leaking flaw, the allowable leakage rate will be determined by dividing the critical leakage rate by a safety factor of four ( 4). The critical leakage rate is determined as the maximum leakage rate that can be tolerated. The critical leakage rate may be based on the allowable loss of inventory or the maximum leakage that can be tolerated relative to room flooding, among others. The safety factor of four to the critical leakage rate is believed adequate to ensure system operability and allow for early identification of conditions that may lead to adverse consequences. to 1700405.401.RO 3-3 SJ Structural Integrity Associates, Inc. l

CONCLUSIONS Attachments 1 - 3 RR5-02, Cooper Nuclear Station Page 26 of 26 This attachment provides a technical basis for proposed alternative use of ASME Section XI Code Case N-513-4. The discussion provided herein demonstrates that the use of Code Case N-513-4 will reduce plant burden without any adverse effect on safety. Consistent with a previous NRC safety evaluation of a generic Code Case N-513-4 request, an additional leakage limitation requirement has been included. REFERENCES

1.

ASME Code Case N-513-4, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division I," Cases of the ASME Boiler and Pressure Vessel Code, May 7, 2014.

2.

ASME Code Case N-513-3, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division l," Cases of the ASME Boiler and Pressure Vessel Code, January 26, 2009.

3.

Regulatory Guide 1.14 7, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division I," Revision 17, August 2014.

4.

McGill, R.O., Cipolla, R.C., DeBoo, G. and Houston, E.J., "Technical Basis for Proposed Fourth Revision to ASME Code Case N-513," Proceedings of the ASME 2014 Pressure Vessels & Piping Conference, PVP2014-28355.

5.

NRC Relief Request Approval and Safety Evaluation Report for Exelon Generation Company Fleet Request for Proposed Alternative to Use ASME Code Case N-513-4, ADAMS Accession No. ML16230A237. to 1700405.401.RO 3-4 e Structural Integrity Associates, Inc.

NLS2017071 Page 1of34 RR5-03, Cooper Nuclear Station Structural Integrity Associates, Inc. Final Code Case N-513-3 Markup for Revision 4 Technical Basis for Proposed Fourth Revision to ASME Code Case N-513 Cooper Nuclear Station Technical Basis for Proposed Alternative to Use ASME Code Case N-513-4 and Scope Expansion to a Higher Pressure Limit Note: Enclosed report contains 33 pages not counting this cover page. Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 1 of 33 Final Code Case N-513-3 Markup for Revision 4

Record# 12-841 Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 2 of 33 CASES OF ASME BOILER AND PRESSURE VESSEL CODE CASE N-513-4J Approval Date: January 26, 2009 Code Cases will remain available for use until annulled by rhe applicable Standards Committee. Case -513-9 Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1 Inquiry: What requirements may be used for temporary acceptance of flaw s, including through-wall flaws, in moderate energy Class 2 or 3 piping mc\\udmg elbows. bent pipe, reducers. expanders and branch tees, without performing a repair/replacement activity? Reply: It is the opinion of the Comm ittee that the following requirements may be used to accept flaws, including through-wall flaws, in moderate energy Class 2 or 3 piping mc\\udmg dbows. bent pipe reducer; expanders. and branch tees, without performing a repair/replacement activity for a limited tim e, not exceeding the l'iahiallaR ~uteEI as EleflfllEI 111 th~; Atsel!me to the next scheduled refuelmg outa ~e. SCOPE (a) These requirements apply to the ASME Section III, ANSI B3 l. I, and ANSI B3 l. 7 piping, classified by the Owner as Class 2 or 3 that 1s accessible for 111:>p ecllon. The prov is ions of this Case do not apply to the following: (1) pumps, valves, expansion joints, and heat exchangers except as pron ded m lb!; (2) weld metal of socket welded joints; (3) leakage through a flange joint; (4) threaded connections employing nonstructural seal welds for leakage protection. lb! This Case ma\\ be applied to heal exchanger external tub mg or pir mg provided the flaw 1s charactenzed m accordance wtth 2ca*1 and leakage 1s momtoml (f.b) The provisions of this Case apply to Class 2 or 3 piping m liyu1d svstems whose maximum operating temperature does not exceed 200"F (93°C) and whose maximum operating pressure does not exceed 275 psig (1.9 MPa) (!if!;) The following flaw evaluation cnteria are permitted for pipe and tube mcludmg elbows. bent pipe. reducers. expanders. and branch tees. The straight pire flaw evaluation criteria are permitted for adjoining fittings and flanges to a distance of (R0t)" from the weld centerline. Draft 15 (05105114) C'l The p1pmg <.b1gn <..ode shall be used m determinmg the stress md1ces B and B and stre,;,, mtens1f1callon factor / for Oaw evaluation following Code anplicab1ht1 lim its m terms of component <teomelf\\ such as D.,J,,.,m ratio ff the piping design Code does not prov ide stress indices, Secllon lH. 2004 Ed1t10n or later Ed1llons and Addenda may be used to def me B and B ([ii) The provisions of this Case demonstrate the integrity of the item and not the consequences of leakage. It is the responsibility of the Owner to 101" aRs!Fal* s;**l*i:* e~ l Fee1li1y consider.,;g effects of leakage in demonstrating svstem operabl11\\) and performing plant llooding analvses. (ti Hil "' ahiet1eR ~en ea 1'- i.; !he Sfl<ret1e11al time feF,;h1eh !he lefl1~eF0f)* eee l~laRe o enlrna eFo

atl!;liea bill Ret e'teeetl1Rg 20 mtlR!hs frem !ho Mdl!sl d1see 1*ef)* efthl ee11ame11.

2 PROCEDURE (a) The flaw geometry shall be characterized by volumetric inspection methods or by physical measurement. The full pipe circumference at the flaw location shall be inspected to characterize the length and depth of all flaws in the pipe section. (b) Flaw shall be classified as planar or nonplanar. (c) When multiple flaws, including irregular (compound) shape flaws, are detected, the interaction and combined area loss of flaws in a given pipe section shall be accounted for in the flaw evaluation. (d) A !law evaluation shall be performed to determine the conditions for flaw acceptance. Section 3 provides accepted methods for conducting the required analysis. (e} Frequent periodic inspections of no more than 30 day intervals shall be used to determine if flaws are growing and to establish the tim e~_,..._a l which the detected flaw will reach the allowable size. Alternatively, a flaw growth evaluation may be performed to predict the time,----;......., at which th.e detected flaw will grow to the allowable size. The flaw growth analysis shall consider the relevant growth mechanisms such as general corrosion or wastage, fatigue, or stress corrosion cracking. When a flaw growth analysis is used to establish the allowable time for temporary operation, periodic examinations of no more than 90 day intervals shall be conducted to verify the flaw growth analysis predictions.

Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 3 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-:!;l (/) For through-wall leaking flaws, leakage shall be eesep; ea e:*monilored daily '>"BlliB0WRS to confinn the analysis conditions used in the evaluation remain valid. {g) If examinations reveal flaw growth rate to be unacceptable, a repair~replacement acti> 1tv shall be performed. (h) Repair-eF-Lreplacement activities shall be performed no later than when the predicted flaw size from either periodic inspection or by flaw growth analysis exceeds the acceptance criteria of 4, or during the next scheduled rrliJ..cling_outage, whichever occurs firsL Repair~replacement activities shall be in accordance with IWA-4000 er l"'A 7009. res1ieet1.,

  • e1~*.

iA Bditiens aml AdaeflEla ~ rier ta ll<le 1991 AdEl...,Ela. anEI. 1R !Re 1991 \\aEleAEla anEI later. iR aeee*Elatiee "' i~i pv' IQOO. (i) Evaluations and examination shall be documented in accordance with IWA-6300. The Owner shall document the use of this Case on the applicable data report form. 3 FLAW EVALUATION Planar flaws tn strai2ht pipe shall be evaluated in accordance with the requirements in 3.1. Nonplanar flaws in straight pipe shall be evaluated in accordance with the requirements in 3.2. Through-wall llaws in elbows and bent pipe shall be evaluated in accordance with the requirements in 3.3. Through-wall llaws in reducer>. expander., and branch tees shall be evalualed in accordance with the requirements in 3.-l and 3.5 respectively. Flaw growth evaluation shall be perfo1med in accordance with the requirements in 3.§.>. Nonfe1rous materials shall be evaluated in accordance with the requirements in 3.2+. For all !law evaluauon. all Service Level load combinations shall be evaluated to determine the most limiting allowable flaw size. 3.1 Planar Flaws in Str aight Pipe (~ For planar flaws, the flaw shall be bounded by a rectangular or circumferential planar area in accordance with the methods described in Appendix C. IW A-3300 shall be used to determine when multiple proximate flaws arc to be evaluated as a single flaw. The geometry of a through-wall planar flaw is shown in Fig. I. {b) For planar flaws in austenitic piping, the evaluation procedure in Appendix C shall be used. Flaw depths up to LOOOA> of wall thickness may be evaluated. When through-wall circumferential flaws are evaluated, the formulas for evaluation given in C-5320 or C-6320. as applicable of Appendix C may be used, with the flaw depth to thickness ratio, alt, equal to unity. Draft 15 (05/05/14) When through-wall axial flaws are evaluated, the allowable flaw length is: td,= u&./R![((sF~)zaJ-T (I) a, = pD0/2t ~ (2) where a, = (s, +s,) 12 ~ (3) p = pressure for the loading condition Do = pipe outside diameter a1 = flow stress .s;. =Code specified yield strength ~ : Z has been added to equation (!). S, =Code specified ultimate tensile strength and SFm = structural factor on primary membrane stress as specified in C-2622 Z = load multiplier for ductile flaw mensioo !equal to l. Owhen using limit load criteria) Material properties at the temperature of interest shall be used. -"---~\\ (c) For planar flaws in ferritic piping, the evaluation procedure of Appendix C shall be used. Flaw depths up to l 00% of wall thickness may be evaluated. flID:\\' deoth a 1* defined in figures C'-4310-1 and C-43 10-2 When through-wall circumferential flaws are evaluated in accordance with C-5300 or C-6300, the flaw depth to thickness ratio, alt, shall be set to unity. When applying the Appendix C screening criteria for through-wall axial flaws, alt shall be set to unity, and the reference limit load hoop stress, 01, shall be defined as o/ Jvl,.. When through-wall axial flaws are evaluated in accordance with C-5400 or C'-MOO the allowable length is defined by eqs. (L) through (3), with the appropriate slructural factoro from Appendix C, C-2622 When through-wall flaws are evaluated in accordance with C-7300 or C-7400, the fonnulas for evaluation given in C-4300 may be used, but with values for Fm, Fo, and F applicable to through-wall flaws. Relations for Fm, Fi. and F that take into account flaw shape and pipe geometry (Rlt ratio) shall be used. The appendix to this Case provides equations for Fm. Po, and F for a selected range of Rft. Geometry of a through-wall crack is shown in Fig. I. 2

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 4 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513--'J FIG. 2 SEPARATION REQUIREIVENTS FOR ADJACENT THINNED AREAS 3.2 Nonphuur Flaws in Straight Pipe __fa) The evalmtion shall consider the depth and extent of the affected area md require thit the wall thickness exceed tmm for a distance th!t is the greater of 2.5 "Rt..,., or U,,,,,.,. between adjacent thinned regions, where R is the mean radius of the piping item based on nominal wall thickness and Lm.a-.g is the average of the extent of Lm below t.,,;" for adjacent a-eas (see Fig. 2). Alternatively, the adjacent thinned regions shall be considered a single thinned region in the evaluation. __jb) For nonplanar flaws, the pipe is acceptable when eithorr !b)(l) and (bH 2l. or (b)(2) and !bl(31 are met. --1.llJ:. e remaining pipe thickness (tp) is greater than or e<pal to the minimum wall thickness t..,": t PL\\, m 2(S +0.4p) (4) where p = mrocimum operating pressure at flaw locition S = allowable stress at operating temperlture 12/ The remaining degraded pipe section meets the longitudinal stress limits in the design Code for the P.iPi.!!& Iii As an alternative to 1b)(ll,\\lte1'HBlt*el), an evaluition of the remaining pipe thickness It,,) may be performed as given below. The evaluition procedure is a function of the depth and the extent of the affected area as illustrated in Fig. 3. {L-/.) When Wm is less than or equal to 0.5 (Rol)112, where Ro is the outside radius and Wm is def med in Fig. 3, the flaw can be classified as a planar flaw and evaluited in accordance with 3.l(a) through 3.l(c), above. When the above requirement is not satisfied, (-rji) shall be met. L_..,) When Lm~) is not greater than (Rolmm )Ill, taJoc is determined from Curve 1 of Fig. 4, where Lm~) is Draft 15 (05/05/14) defmed in Fig. 3. When the above requirement is not satisfied, (~ shall be met (;Ji~) When L., is less than or equal to 2.65 (Rot..,,,)112 and tnom is greater than 1.13 tmm, ta1oc is determined by satisfying both of the following equations: t 1.5 ""[ t ] ~ ~ ~1 -....!!!!!!.. + l. O t_ L t_ (5) t."" ~ 0.353L,,, t..., JRot,,,. (6) When the above re<pirements a-e not satisfied, (41_D shall be met (il.>.4) When the requirements of (.,<.,j, (~. md (~.ill above are not sltisfied, ta1oc is determined from Curve 2 of Fig. 4. [n eaaille1t. f-Jlmll

!81i~* tfte fella.tng eftuetien.

~~is the naminal )ll~e leng1lueli11al eElleling sire"' "'"'llin,,. ft em all Se... iee Le, el B ""II!' !'ii'* ~ (c) When there is through-wall leakage along a portion of the thinned wall, as illustrated in Fig. 5, the flaw may be evalu!ted by the branch reinforcement method The thinned area including the through-wall opening shall be represented by a circular penetration at the flaw location. Only the portion of the flaw lying within ta1; need be considered as illustrated in Fig. 6. When evaluating multiple flaws in accordance with 3.2(a), only the portions of the flaws contained within tad/ need be considered.

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 5 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-~ FIG. 3 ILLUSTRATION OF NONPLANAR FLAW DUE TO WALL THIN NING Axial direction Draft 15 (05105114) i Lm1n Transverse lclrcumferentlall direction Editor's Note. This Figure 3 ts to be deleted and replaced with the Figure 3 on the following page 4

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 6 of 33 CASE (continued) CASES OF ASl\\llE BOILER AND PRESSURE VESSEL CODE N-513-4J FIG. 3 ILLUSTRATION OF NONPLANAR FLAW DUE TO WALL THINNING t lmm i L,,,1*1-Transverse (circumferential) direction FIG. 4 ALLOWABLE WALL THICKN ESS AND LENGTH OF LOCALLY THINNED AREA 0.6 _E ) 0.4 0.2 f----+-- 0 '----~--~----"-----"'-----------'-----" 0 6 7 8 Draft 15 (05/05/14)

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 7 of 33 CASE (continued) CASES OF ASME BOil..ER AND PRESSURE VESSEL CODE N-5134.! FIG. 5 ILLUSTRATION OF THROUGH-WALL NONPLANAR FLAW DUE TO WALL THINNING Axial { Draft 15 (05/05/14) Through-wall / opening r l...,1rc Tra111sverse (circumferential) di rection Editor's Note Tlus Figure 5 is to be deleted and replaced with lhe Figure 5 on lhe fullowmg page

CASES OF ASME BOILER AND PRESSURE VESSEL CODE Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 8 of 33 CASE (continued) N-513-4.J FIG. 5 ILLUSTRATION OF THROUGH-WALL NONPLANAR FLAW DUE TO WALL THINNING Through-wall l t. / opening t min

  • r::_~

~~. ~ Laxia1-Axial I direction Transverse Lcirc (circumferential) direction Draft 15 (05/05/14)

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 9 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4J The minim um wall thickness, t,.,,., shall be determ ined by eq. (4). For evaluation purposes, the adjusted wall thickness, fad;, is a postulated thickness as shown in Fig. 6. The pipe wall thickness is defined as the thickness of the pipe in the non-degraded region as shown in Fig. 6(a). The diameter of the opening is equal to d.d1 as defmed by l ad; as shown in Fig. 6(a). The postulated value for tad; shall be greater than t,. 0, and shall not exceed the pipe wall thickness. The fad; value may be varied between Imm and the pipe wall thickness to determine whether there is a combination of laJ; and d.d1 that satisfies the branch reinforcement requirements. The values of l ad; and d,,d; of Fig. 6(b) shall satisfy: Cl~) The remaining ligament average thickness, 1""'"' over the degraded area bounded by d.d; shall satisfy: (]9) In addition the pipe sect10n mcludmg the equ11*aknt hole representation shall meet the lon1utudmal stress limits m the design Code for the ll!l2!!l&. __ If a flaw growth analysis is performed, the growth in flaw dimensions shall consider the degradation mechanisms as relevant to the application. The flaw is acceptable when there is sufficient thickness in the degraded area to provide the required area reinforcement. (d) Alternatively, if there is a through-wall opening along a portion of the thinned wall as illustrated in Fig. 5 the flaw may be evaluated as two independent planar through-wall flaws, one oriented in the axial direction and the other oriented in the circumferential direction. The minimum wall thickness lmm, shall be determined by eq. (4). The allowable through-wall lengths in the a'Cial and circum ferential directions shall be determined by varying lad; shown in Fig. 5 from !,,.,. to lmm. The allowable through-wall flaw lengths based on tad; shall be greater than or equal to the corresponding L.,,.1 and L"" (see Fig. 5) as determined from 3. l(a) and 3. l(b) or

3. l(c), as appropriate. The remaining ligan1ent average thickness, le.avg, over the degraded area bounded by L.,,.i and L"" shall satisfy eq. @!)).

3.3 Through-wall Flaws in Elbow' and Bent Pipe Through-wall flaws m elbows and bent pme ma' be evaluated usmg the straight pme procedures given m 3 I or 3.2(d) pro,*1ded the stres.~es usecl m the evaluation Draft 15 (05/05/1 4) are ad1usted to account for the geomdrv differences as Jescnbed belo\\\\ Alternative metho<ls ma' be used to calculate the stresses used m evaluauon The hoop stress a for dbov. and bent pme evaluation shall be. a =( pD*)[ 2R...,+R 0 sin¢ ]+(~) R.M, 9. 2t 2(R,.., + R 0 sin¢) h'" l --1.21 R... 0 elbow or bent pipe bend radtu' rp C!fcumferentml anl!lc defined m figure 7 h flex1bilit\\ charactensuc M,. resultant pnmary ben<lmg moment I moment of menta based on evaluation wall thickness f Euuat10n 9 ts only apphcabk for elbov.s and bent pipe where h - 0 I The ""'"I membrane pres.,ure stress a, for elbow and bent pipe evaluatton shall be v.here B. is a pnmarv stress mdex as defined m Secuon lll for the pmml! item B shall be equal to 11 5 for elbows and bent pipe The axial bending stress, a., for elbo" and bent pipe evaluation shall be a = B, ( D.M ' ) II ' 21


~~

where B is a prunary stress index as defined m Section lll for the pmmg item The themial expansion stress a for elbow am! bent pme evaluation shall be a = i ( D.Alf,) ------~~'-= ~ 21 stress mtens1tical!on factor as d~fmcd in th~ <les1im \\o<le for the pmmg item .If. resultant !hernial exoans1on moment 8

Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 10 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4.1 3.4 Through-wall Flaws in Reducers and Expanders Throu!!h-wall llaws m reducers and expanders ma' be evaluated usmg the stra1!!ht pme procedures given in 3 l or 3.2(d) provided the stresses used m the evaluallon are adjus1etl to account for the e.eometr-diffrrences as descnbed below Alternative methods mav be used to calculate the stresses used m evaluation Fig 8 ti Justrates the reducer and expander zones discussed below. Evaluation of llaws in the small end translllon zone is outside the scope of this Case. The hoop stress u,, and axial membrane pressure stress u,,. for reducer or expander evaluat10n shall be a- (PD.) (131

  • = u -~

___ a-~= B1( ~ )-----~l-1~ where D, is the small end OD for flaws m the small end and the lame end OD for all other flaws The axia l bendtnl! stress. u.. and thermal expansion stress, u. for reducer or expander evaluatton shall be: a- = B ( D*M*)----~'-"L,__,_' b 2 21 ___ a-, = { D;~* ) -------'-("'"'lb'-"-) where I ts based on the de11.raded sect10n 3.5 Through-wall Flaws in & *anch Tees Branch reinforcement requirement' shall he met m accordance with the design Code If the design Code did not reqmre remforcement for evaluation purposes. a n:mforcement re11.ion is defined as a regmn of radius D o[ the branch pme from the center of the branch connecllon Through-wall tlaws m branch tees outskle of the reinforcement region may be ernluated using the strai11.ht pme procedures given m 3 1 or 3 2(dl prov ided the stresses used m th~ evaluat10n are ad1usted to account for the geometrv differences as described below. Altemauve methods mav be used to calculate the stresses used in evalua11on. Evaluatton of tlaws in the re>!iOn of branch reinforcement IS OUtslCk the scope of this Case The hoop s'tress U;, and axial membrane pressure stress, u~ for branch tee evaluation shall 11<'. determined from eq. (13) and eg (1-1) respecuveh The outside thameter for each of these equat10ns shall be for the branch or run pipe, dependmg on the flaw location Draft 15 (05/05114) [he axial bending stress u, and !hernial expansion stress. u, for branch tee evaluation shall be tletem11ned from eg (1 'land eu (16). respecuveh 3.@ Flaw G rowth Evaluation If "7i flaw growth analysis is performed, the growth analysis shall consider both corrosion and crack-growth mechanisms as relevant to the application. In performing a tlaw growth

analysis, the procedures in C-3000 may be used as guidance.

Relevant growth rate mechanisms shall be considered. When stress corrosion cracking (SCC) is active, the following growth rate equation shall be used: where da/dt is flaw growth rate in inches/hour, Kmox is the maxim um stress intensity factor under long-term steady state conditions in ksi in. 0~, Sr is a temperature correction factor, and C and n are material constants. For intergranular SCC in austenitic steels, where T S 200°F (93°C). C = 1.79 x 10-s Sr = I n = 2. 161 For transgranular SCC in austenitic steels, where T S 200°F (93°C). C = l.79x 10-1 Sr = 3.7! x IO" [I O(o.oi842 r-i2.2')] n = 2. 161 The temperature, T, is the metal temperature in degrees Fahrenheit The flaw growth rate curves for the above SCC growth mechanisms are shown in Figs. 2.+ and l!_>>:. Other growth rate parameters in eq. (lli.l) may be used, prov ided they are supported by appropriate data. 3.24 Nonferrous Materials For nonferrous materials, nonplanar and planar flaws may be evaluated following the general approach of 3.1 through 3.~ For planar flaws in ductile materials, the approach given IA J I (b 1 RRd 3 Jfor austeruttc pipe may be used; otherwise, the approach given "" J l f81 aRil J Jfor femtic pine should be applied. Structural factors provided in 4 shall be used. It is the responsibility of the evaluator to establish conservative estimates of strength and fracture touglmess for the piping material. 9

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 11 of33 CASE (continued) CASES OF ASME BOILER A:'ID PRESSURE VESSEL COD E N-513-..i.l FIG. 6 ILLUSTRATION OF ADJUSTED WALL THICKNESS AND EQUIVALENT HOLE DIAMETERS Through-wall T Pipe CU-"'-"-"'-"..::..J..+-------+....L:..-"'-"'-"'-"'~lwall lal ~djusted Wall Thlck~ess Shift figure (b ) lo the right so that dadj tm,,. width lines up with TI t figure (a). + m-i-----------a r:.~

e-d --.~

f---dod/ --l (bl Equivalent Hole Representation FIG. 7 CIRCUMFERENTIAL ANGLE DEFINED Draft 15 (05/05114) 10

CASES OF ASME BOILER AND PRESSURE VESSEL CODE FIG. SZONES OF A REDUCER OR EXPANDER GENERAL NOTE: l arge end transition zone transition zo ne Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 12 of 33 CASE (continued) N-513--lJ. Transit io~ zones extend from the poim on the ends where th e diameter begins to change to the pomt on the central cone where the cone angle is constant. Draft 15 (05/05/14) 11

CASES OF ASME BOILER AND PRES.SURE VESSEL CODE Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 13 of 33 CASE (continued) N-513-4~ FIG. ~ FLAW GROWTH RATE FOR IGSCC IN AUSTENITIC PIPING H Auslontti: Plplr>~ T<.lOCf lr.E-43 1.CE-04 1.CE.-07 1£E.Ql3 I / / / / / / v / / 10 ICO Draft 15 (05/05/14) 12

CASES OF A SME BORER AND PRESSURE VESSEL CODE Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 14 of 33 CASE (continued) N-513-~ F I G. ~~ FLAW GROWTH RA TE FOR TGSCC IN A USTENITIC PIPING U E-02 Fl AIKIW"IU,:; fltpln;J T ::.:.2D~ UE.JJ3 ii ~ l.CE44

====1 T* l>ltf ~ 1.CE-'lS ~ 1.CE.06 1l 1.CE-08 1.CE-00 I / / / / / / v / / / v V' v / / [ T* IOCf J 10 Dru t 15 (05/05/14) 13 --1

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 15 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4.1 4 ACCEPTANCE CRITERIA Piping containing a circumferential planar flaw is acceptable for temporary service when flaw evaluation provides a margin using the structural factors in Appendix C, C-262 1. For axial planar flaws, the structural factors for temporary acceptance are as specified in Appendix C, C-2622. Straight rPi~<Rg containing a nonplanar part.::-through-wall flaw is acceptable for temporary service if the remammg pme section meets the long1tu<lmal stress limits m the design Code for the p1pmg and lp !! t.J"" where laJoc is detennined from 3.2(b). Straight oPiJ)£<Rg containing a nonplanar through-wall flaw is acceptable for temporary service when the flaw conditions of 3.2(c) or 3.2(d) are satisfied. An elbow or bent pipe contamml! a nonplanar through-wall flaw "acceptable for temporar' service 11 the llaw comht1ons of 3 3 are sallsfied A reducer or expander contammg a nonplanar through-wall fla\\\\ ts acceptable for temporao sen*1ce 1f the flaw condi!tons of 3.J are sallsfied A branch tee contammg a nonplanar through-wall llaw is acceptable for temporary service if the flaw conditions of 3 5 are satisfied. 5 AUGMENTED LXAMINATION An augmented volumetric examination or physical measurement to assess degradation of the affected system shall be performed as follows: (a) From the engineering evaluation, the most susceptible locations shall be identified A sample size of at least five of the most susceptible and accessible locations, or, if fewer than five, all susceptible and accessible locations shall be examined within 30 days of detecting the flaw. (b) When a flaw is detected, an additional sample of the same size as defined in 5(a) shall be exam ined. (c) This process shall be repeated within 15 days for each successive sample, until no significant flaw is detected or until I 00% of susceptible and accessible locations have been examined. 6 B.,B c D D, F NOMENCLATURE Secuon 111 rnmarv stre" m<lices coefficient in the crack growth relationship 1n.s1de pipe diameter outside pipe diameter nondim ensional stress intensity factor for through-wall axial flaw under hoop stress nondimensional stress intensity factor for through-wall circumferential flaw under pipe bending stress Draft 15 (05/05/14) L L axial l.. (o) L..111 L...~. .\\I R ii_ R, s SFm L a c daldt It nondimensional stress intensity factor for through-wall circum ferential flaw under membrane stress moment of mertia based on evaluauon thickness I maximum stress intensity factor wider long term steady state conditions maximum extent of a local thinned area with t < l.om length of idealized through-wa II planar flaw opening in the axial direction of the pipe, as illustrated in Fig. 5 length of idealized through-wall planar flaw opening in the circumferential direction of the pipe, as illustrated in Fig. 5 maximum extent of a local thinned area with t < lmin axial extent of wall thinning below lmm circumferential extent of wall thinning below lmm average of the extent of L.. below lmm for adjacent thinned areas maximum extent of thinned area, i bulging factor for axial flaw resultant [lrtmarv bending moment resultant thcnnal expansion mom~nt mean pipe radius elbow or bent pipe centerlme bend radius outside pipe radius allowable stress at operating temperature structural factor on primary membrane stress coefficient for temperature dependence in the crack growth relationship Code-specified ultimate tensile strength Code-specified yield strength metal temperature maximum extent of a local thinned area perpendicular to Lm with t < Imm minimum distance between thinned areas i and} load mult1pl1er for ducllk fla\\\\ extension flaw depth half crack length flaw growth rate for stress corrosion cracking diameter equivalent circular hole at 1,.1 diameter of equivalent circular hole at lmm flex1b1htv charactenstK stress mten.~ificat1on factor total crack length = 2c allowable axial through-wall flaw length exponent in the crack growth relationship 14

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 16 of 33 CASE (continued) CASES OF ASME BOILER AND PRES.SURE VES.SEL CODE N-513-4~ p maximum operating pressure at flaw location evaluation wall thickness surrounc.hng the de2raded area tad1 adjusted wall thickness which is varied for evaluation purposes in the evaluation of a through-wall nonplanar flaw t.,"" allowable local thickness for a nonplanar flaw t,.w8 average remaining wall thickness covering degraded area with through-wall leak bounded by d.d} tm~ minimum wall thickness required for pressure loading tnom nominal wall thickness tp minimum remaining wall thickness a maximum cone anl!le at the center of a reducer A. nondimensional half crack length for through-wall axial flaw If! circum ferenual angle from dbow or bend llimk (J,, axrnl bendmg stress for pnmmv loading rI axial thermal expansion stress rIJ material flow stress rih pipe hoop stress due to pressure and bending moment (for elbows and bent ~ 6, ReniRal leR51t1<8!Ral 13sRd* g.-1ra:s !er 13 riffi e ~

  • lsaelffig w itRsHt S ~Fe1 0 t ;

I F1h!R ~ l~I ea!ieR feater a1 reference limit load hoop stress a:r; ax.ml prc!ssure stress riy material yield strength at temperature, as defined in C-4300 !lllle rettttHetl fer!ke tleteetetl Rs.,* to gre.. le tka a lle.. eele Raw .nu. littt Rel a <eeea1A3 ~0 '" eAtks tfe1i1

!;a 1m1ial Elwee*1eFy ef tfie eeREllHeR B

half crack angle for through-wall circumferential flaw 7 APPLICABILITY Hu* Gao

  • ts Bf"phaael* freR1 ti>* 19gJ J:le1tteR,,.,11>

IA* ll mt*r 19g?." EleaR<la. tli:s1<gfi Elle 21J' l7 e dmeR

  • qtfi tfi* 201W,\\.JEleR,la. Reference to Appendix C in this Case shall apply to Appendix C of the 2004 Edition or later ed1t1ons or addenda. For editions !!R<l-or addenda prior to !h!;_2004 Edition, Class I pipe flaw evaluation procedures may be used for other piping classes. As a matter of definition, the current term "structural factor" is equivalent to the term "safety factor," which is used in earlier editions and addenda.

Draft 15 (05/05/1 4) hdttor*s '!ote. for Apphcabdtt' Index. appl1cabili\\) is lrom 1996 Addenda to ~IJ13 Ed1uon 15

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 17 of 33 CASE (continued) CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-513-4~ MANDATORY APPENDIX I RELATIONS FOR Fm, Fb, AND FFOR THROUGH-WALL FLAWS 1-1 DEFINITIO S For through-wall Oaws, the crack depth,_..!a.; will be replaced with half crack length,_ --tcJ in the stress intensity factor equations in C-7300 and C-7400 of Section XI, Appendix C. Also, Q will be set equal to unity in C-7400. 1-2 CIRCUMFERENTIAL FLAWS For a range of Rlt between 5 and 20, the following equations for Fm and Fb may be used: Fm= 1 +Am (8!7r)'-' + Bm (8/7rf' +Cm (t'J1i)B Fb - l +Ab (8/7r)u + Bb (817rf*' +Cb (fJKj'-' where e = half crack angle = c!R R = mean pipe radius t = ~wall thickness and Am = -2.02917 + l.67763 (Rlt) -0.07987 (R/t f + 0.00176 (Rlt)' Bm = 7.09987 - 4.42394 (Rlt) + 0.21036 (R/t )2 - 0.00463 (Rlt)' Cm - 7.79661 + 5.16676 (Rlt) - 0.24577 (R/t)2 + 0.0054 l (Rft)' Draft 15 (05/05/14) Ab = - 3.26543 + l.52784 (Rft) - 0.072698 (R/t f + 0.001601 l (RJt)' Bb = 11.36322 - 3.91412 (Rft) + 0.18619 (R/t )2 - 0.004099 (Rft)' Cb = - 3.18609 + 3.84763 (Rlt) - 0.18304 (R/t f + 0. 00403 (Rf 1)3 Equations for Fm and Fb are accurate for Rlt between 5 and 20 and become increasingly conservative for Rft greater than 20. Alternative solutions for F~ and Fb may be used when Rft is greater than 20. 1-3 AXIAL FLAWS For internal pressure loading, the following equation for F may be used: F = I + 0.0724491. + 0.648561.2 - 0.2327 A.3 + 0.038154 A.4 - 0.0023487 A.' where c = half crack length A. = c/(Rt)vi The equation for F is accurate for A. between 0 and 5. Alternative solutions for F may be used when A. is greater than 5. 16 _J Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 18 of 33 Technical Basis for Proposed Fourth Revision to ASME Code Case N-513

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 19 of 33 Proceedings of the ASME 2014 Pressure Vessels & Piping Conference PVP201 4 July 20-24, 2014, Anaheim, California, USA PVP2014-28355 TECHNICAL BASIS FOR PROPOSED FOURTH REVISION TO ASME CODE CASE N-513 ABSTRACT Roberto. McGill Structural Integrity Associates San Jose, CA rmcgjl l@structint.com Russell C. Cipolla lntertek AIM Sunnyvale, CA russell.cioolla@intertek.com Code Case -5 13 provides evaluation rules and criteria for temporary acceptance of flaws, including through-wall flaws, in moderate energy piping. The application of the Code Case is restricted to moderate energy, Class 2 and 3 systems, so that safety issues regarding short-term, degraded system operation are minimized The first version of the Code Case was published in 1997. Since then, there have been three revisions to augment and clarify the evaluation requirements and acceptance criteria of the Code Case that have been published by AS:tvJE. The technical bases for the original version of the Code Case and the three revisions have been previously published. There is currently work underway to incorporate additional changes to the Code Case and this paper provides the technical basis for the changes proposed in a fourth revision. These changes include addressing the current condition on the Code Case acceptance by the US Nuclear Regulatory Comm ission (NRC), clarification of the Code Case applicability lin1 its and expansion of Code Case scope to additional piping corn ponents. New flaw evaluation procedures are given for through-wall flaws in elbows, bent pipe, reducers, expanders and branch tees. These procedures evaluate flaws in the piping components as if in straight pipe by adjusting hoop and axial stresses to account for the geometry differences. These changes and their technical bases are described in this paper. NOMENCLATURE B,, 82 Primary stress index defined in ASME Section III for the piping item Do Outside diameter I Moment of inertia based on t (degraded section) Mb Resultant primary bending moment GuyOeBoo Exelon Generation Company Warrenville, IL guv.deboo@exeloncorp.com Eric J. Houston Structural Integrity Associates San Jose, CA ehouston@structint.com Resultant therm al expansion moment Elbow or bent pipe bend radius Outside radius Flexibility characteristic Stress intensification factor as defined in the Code of Record for the piping item Ma'<imum operating pressure at flaw location Evaluation thickness Axial bending stress Thermal expansion stress Hoop stress Axial membrane stress Circumferential angle INTRODUCTION

Background

Code Case N-513-3 [!] (currently approved revision) prov ides evaluation rules and criteria for the temporary acceptance of flaws, including through-waLI flaws, in moderate energy piping. The prov is ions of this Code Case are focused on preventing gross failure of the affected pipe for a temporary period. However, it also requires the piping system and adjacent equipment functionality be demonstrated for lost fluid inventory, spraying and flooding caused by the leakage. The Code Case provides rules for the evaluation of degraded pipe and tube for a short operating period, with inspection and monitoring requirements of the degraded condition as part of the overall integrity assessment. The application of the Code Case is restricted to moderate energy Class 2 and Class 3 systems, so that the safety issues regarding short-term system operation are minimized. Moderate energy piping is defined as those piping systems where the maximum operating pressure and temperature do not exceed 275 psig (1.9 MPa) and 200°F (93°C), respectively. Copyright 0 2014 by ASME

Currently. the scope of the Code Case is limited to straight pipe with some prov ision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. There have been many instances where through-wall leaks have been observed in pipe components (i.e., elbows, reducers, expanders or branch tees) or bent pipe outside of the current Code Case scope. As a resull utilities are forced into taking alternate actions (e.g., repair, replacement, or making requests for NRC relie!) that can be significantly more burdensome without any measurable increase in plant safety. The fourth revision of the Code Case provides evaluation rules and criteria for the temporary acceptance of flaws for these instances. In addition. other enhancements are included with the fourth revision as summarized below. Summarv of Code Case N-513-4 Changes The list below summarizes the proposed changes included in Revision 4 of Code Case N-513. Note that a brief reason for each change is included in parenthesis. Temporary acceptance penod redefined (addresses NRC condition given in Regulatory Guide l.147 ['.!]) Flaw evaluation criteria included for elbows, bent pipe, reducers, expanders and branch tees (scope expansion) Allow flaw evaluation of heat exchanger tubing in specific instances (scope expansion) Daily walkdown requirement for through-wall leaks provides additional flexibility for user implementation (scope expansion) Limit scope to only liquid systems (scope clarification) Treatment of Service Level load combinations (scope clarification) Treatment of flaws in au.stenitic pipe tlm< welds (scope clarification) Minimum wall thickness acceptance criteria to consider longitudinal stresses in addition to hoop stress (scope clarification) [n addition, several editorial changes to improve the clarity of the Code Case are included. CODE CASE N-513-4 CHANGES AND TECHNICAL BASIS The following subsections prov ide details regardmg each change and their technical basis. Temporarv Acceptance Period N-513-3 specifies a temporary acceptance period that could extent out to 26 months. The NRC did not endorse this maximwn period length and in the latest revision of NRC Regulatory Guide l. l 47, placed a condition on N-513-3 stating, *' repair or replacement activity temporarily deferred under the provisions of this Code Case shall be perfom1ed during the next scheduled outage." N-513-4 addresses this condition by removing the maximum duration limit and stating, ". the follow ing requirements may be used Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 20 of 33 to accept flaws... without performing a repair/replacement activity for a lin1ited time. not exceeding the time to the next scheduled refueling outage." Note that the word.. refueling'* has been added for further clarification regarding the nature and duration of the plant outage. This language is consistent with the introduction ofNRC Generic Letter 90-05 [3] which the original N-5 13 was based. The second paragraph of90-05 states: "Temporary non-code repairs are applicable until the next scheduled outage exceeding 30 days, but no later than the next scheduled refueling outage.., Flaw Evaluation Criteria for Piping Components and Bent Evaluation and acceptance criteria have been added to N-S 13-4 for flaws in elbows, bent pipe, reducers, expanders and branch tees. A sin1plified approach has been adopted based on the evaluations and results from the Second International Piping Integrity Research Group (IPIRG-2) program reported in Reference [4]. The tlaw evaluation for the piping component is conducted as if in straight pipe by scaling hoop and axial stresses using ASME piping design code stress indices and stress intensification factors to account for the stress variations caused by the geometric differences. In Reference [4], this approach was determined to be very conservative by comparing the failure moments predicted using this approach to the measured failure moments from the elbow tests for through-wall circumferential flaws. Details of the simplified approach are given in the following sections. Flaw Evaluation in Elbows and Bent Pipe. Through-wall flaws in elbows and bent pipe may be evaluated using the straight pipe procedures given in N-5 13-4 provided the stresses used in the evaluation are adjusted to account for geometry differences. The hoop stress for elbow and bent pipe evaluation shall be (Equation 9 of N-513-4) a =( pD0 ) [ 2R,,.,.,+R0 sin¢ ] + (~) RJvl, (9) 2t '.!(R.,,., + R0 sin ¢) h"' I Equation 9 ts only applicable for elbows and bent pipe where h 2'. 0. I. The axial membrane pressure stress for elbow and bent pipe evaluation shall be (Equation I 0 ofN-513-4): 8 1 shall be equal to 0.5 for elbows and bent pipe. The ax[al bending stress for elbow and bent pipe evaluation shall be (Equation l 1 of N-513-4): (R 0M,) " * = B, - (10) (l I) Copyright <O 20 l 4 by ASME

Note that if the piping design Code of Record does not provide a Bi, it may be taken from the ASlvffi Section ill, 2004 Edition or later Editions and Addenda. The thermal expansion stress for elbow and bent pipe evaluation shall be (Equation 12 ofN-513-4):

  • (R 0M,)

(j = 1 -- I (12) The first term of Equation 9 accounts for the hoop membrane stress variation around the circumference of the elbow (higher at the intrados, lower at the extrados assuming a uniform wall thickness). The second term conservatively accounts for the through-wall bending in the hoop direction that results from elbow ovalization due to in-plane or out-of-plane bending and was taken from Reference [5]. Equations I 0-1 2 are consistent with the piping design by rule approach in ASME Section ill, NC/ND-3600 [6]. It is recognized m Reference [ 4] that the simplified flaw evaluation approach may be overly conservative in some instances. Thus. N-513-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. For example, the French have developed a more comprehensive approach in analyzing tlaws in cracked elbows. They have implemented finite element analysis based correlations to determine location specific stresses for flaw evaluation. Reference [7] provides additional details. Flaw Evaluation in Hcduccrs and Expanders. Through-wall flaws in reducers and expanders may be evaluated usmg the straight pipe procedures given in N-513-4 provided the stresses used in the evaluation are adjusted to account for the geometry differences. Figure 8 ofN-513-4 illustrates the reducer and expander zones discussed below. Eva luation of flaws in the small end trarisition zone is outside the scope of -513-4. The hoop stress and axial membrane pressure stress for reducer and expander evaluation shall be: (13) ( pD.) a,. ; 81 21 (14) ote that D, is either the smal l end OD for the small end or 1s the large end OD for the large end. For the large end transition zone and central conical section. D, is the large end OD Also. ifthe piping design Code of Record does not provide a 8 1, it may be taken from the ASME Section ill, 2004 Edition or later Editions and Addenda. The axia l bending stress and thermal expansion stress for reducer and e"pander evaluation shall be: - B (D,M,) a, - 21 (15) a ; ;( D.M,) 2/ Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 21 of 33 (16) Equations 13-16 are consistent with the piping design by rule approach in ASME Section ill. The reducer and expander zones shown in Figure 8 of -513-4 are conststent with those shown in Code Case -597-2 [8]. As with elbows and bent pipe, N-513-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. Flaw Evaluation in Branch Tees. Branch reinforcement requirements shall be met in accordance with the Construction Code If the Construction Code did not require reinforcement, a reinforcement region is defined as a region of radius D, of the branch pipe from the center of the branch connection for evaluation purposes. Through-wall flaws in branch tees outside of the reinforcement region may be evaluated using the straight pipe procedures given in N-513-4 provided the stresses used in the evaluation are adjusted as described below to account for the geometry differences. Evaluation of flaws in the region of branch reinforcement is outside the scope of this Case. The hoop stress and axial membrane pressure stress for branch tee evaluation shall be determined from -513-4 Equation 13 and 14, respectively The outside diameter for each of these equations shall be for either the branch or run pipe depending on the flaw location. The axial bending stress and thermal expansion stress for branch tee evaluation shall be determined from N-51 3-4 Equation 15 and 16. respectively. As discussed previously, Equations 13-1 6 are consistent with the piping design by rule approach in SwlE Section III. The limitation regarding flaw evaluation within the branch reinforcement region is consistent with guidance given in Code Case 1 -597-:.. As with elbows and bent pipe, N-5 13-4 allows for alternate methods to be used to calculate stresses used in the flaw evaluation. Flaw Evaluation of Heat Exchanger Tubing -513-4 allows for flaw evaluation in heat e"changer tubing provided the flaw can be characterized and the leakage monitored. The technical basis is that knowledge of tlaw geometry is needed to evaluate the structural mtegrity of the tubing containing the fl aw. An e"ample application from plant operating experience would be for leaks in nonferrous tubing of air cooling coils. The heat exchangers being of plate-fin design could have tubing accessible for volumetric inspection. Flexibilitv in Dailv Walkdown Requirement N-513-4 changes the daily walkdown requirement for leaking flaws from **... leakage shall be observed by daily walkdowns... ** to *'... leakage shall be monitored daily. This change allows for other techniques lo be employed in meeting the intent of the requirement instead of only physical walkdowns. Such techniques could include remote visual Copyright 0 20 14 by ASME

equipment or leakage detection systems to determine if leakage rates are changing. Scope Limited to Liquid Svstems Provisions of N-513-4 are now specifically lim ited to only liquid systems. The methods ofN-513-4 should not be applied to the piping of air or other compressible fluid systems. Treatment of Service Level Load Combinations N-513-4 now specifically requires all Service Level load combinations to be considered in flaw evaluations to detennine the most limiting. N-5 13-3 was previously silent as to what Service Level loading to consider. However, this requirement was im plied in previous Code Case revisions when it required the use of pipe fl aw evaluation procedures specified in the referenced, non-mandatory appendices of ASlvlE Section XI. Appendix C in the 2002 Addenda and later editions and addenda, and Appendix H for ferritic materials in earlier editions, required all operating conditions or Service Levels be evaluated. Treatment of Flaws in Austenitic Pioe Flux Welds A reference to SlvlE Section XI, Appendix C, C-6320 has been added to paragraph 3. l(b) to address the instance where a flaw in an austenitic pipe flux weld requires evaluation. Such a flaw would require the use of Elastic Plastic Fracture Mechanics (EPFM) criteria instead of Limit Load criteria. Equation I of -513-4 now includes a Z factor to account for this specific application. When the original version of N-513 was developed, Appendix C of ASlvlE Section XI only included flaw evaluation criteria for austenitic piping. The change from 513-1 to -2 included the reference changes to the new Appendix C that combined austenitic and ferritic flaw evaluation criteria. The need to reference EPFM critena for an austenitic tlux weld flaw evaluation was overlooked. Minimum Wall Thickness Acceptance Criteria In establishing a minimum wall thickness acceptance criteria for paragraphs '.2(b) and 3.2 (c) ofN-5 13-4. the requirement to consider longitudinal stresses in addition to hoop stress is added. While it is unlikely that a longitudinal stress based minimum wall thickness would be Limiting compared to the hoop stress based minimum wall thickness, the user should be aware of this possibility and confinn an appropriate t~,. as an acceptance criterion. CONCLUSIONS This document serves as the technical basis for the fourth revision of Code Case N-513 This Code Case provides evaluation rules and cntena for temporary acceptance of flaws, including through-wall flaws, in moderate energy Class 2 or Class 3 piping. Currently, the scope of the Code Case is limited to straight pipe with some prov ision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. N- -13_4 provides flaw evaluation rules and criteria for elbows, bent pipe, reducers. expanders Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 22 of 33 and branch tees. In addition, several other scope expansions and clarifications are included as well as editorial improvements. With these changes, it is believed the Code Case will be of even greater use to utilities in avoiding unscheduled plant shutdowns without negatively impacting plant safety. ACKNOWLEDGEMENTS The development of Code Case N-513-4 was through the efforts of the Working Group on Pipe Flaw Evaluation. The authors wish to recognize the efforts of all Working Group members especially the Working Group Chair, Dr. Doug Scanh. REFERENCES I.

3.
4.
5.
6.
7.
8.

ASME Code Case N-5 13-3, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1," Cases of the ASME Boiler and Pressure Vessel Code, January 26, 2009. Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division l," Revision 16. October 2010. NRC Generic Letter 90-05. "Guidance for Perfonning Temporary Non-Code Repair of ASME Code Class 1. 2, and 3 Piping," (June 15, 1990). Ki linski. T., Mohan, R., Rudland, D., Fleming, M., Olson, R., Scott, P., Brust, F., Ghadiali, N., Witkowski, G., and Hopper, A., "Fracture Behavior of Circumferentially Surface-Cracked Elbows," NUREG/CR-6444, BMI-219'.!, December 1996. Moore, SE., and Rodabaugh, E.C., "Background for Changes in the 198 1 Edition of the ASME Nuclear Power Plant Components Code for Controlling Primary Loads in Piping Systems," Journal of Pressure Vessel Technology. Volum e 104, pp. 351 -

361, ovember 1982.

ASME Boiler and Pressure Vessel Code. Section ill, NC/ND-3600, 2004 Edition_ Marie, S.. Chapuliot, S.. Kayser, Y., Lacire, M.H., Drubay, B., Barthe let, B., Le-Delliou, P., Rougier, V, Naudin, C., Gilles, P., and Triay, M, "French RSE-M and RCC-MR. Code Appendices for Flaw Analysis: Presentation of the Fracture Parameters Calculation - Part IV: Cracked Elbow," International Journal of Pressure Vessels and Piping 84, pp. 659-686, May 2007. ASlvlE Code Case N-597-2. "Requirements for Analytical Evaluation of Pipe Wall Thinning, Section XI, Division l."Cases of the ASME Boiler and Pressure Vessel Code, November 18, 2003. Copyright 0 2014 by ASME Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 23 of 33 Cooper Nuclear Station Technical Basis for Proposed Alternative to Use ASME Code Case N-513-4 and Scope Expansion to a Higher Pressure Limit

INTRODUCTION Background of Code Case N-513-4 Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 24 of 33 Code Case N-513-4 [1] provides evaluation rules and criteria for the temporary acceptance of flaws, including through-wall flaws, in moderate energy piping. Moderate energy piping is defined as those piping systems where the maximum operating pressure and temperature do not exceed 275 psig and 200°F, respectively. The provisions of the Code Case are focused on preventing gross failure of the affected pipe for a temporary period while permitting leakage within the plant's Technical Specification. The Code Case provides rules for the evaluation of degraded pipe and tube for a short operating period, with inspection and monitoring requirements of the degraded condition as part of the overall integrity assessment. The previous Code Case revision, N-513-3 [2], is conditionally approved by the NRC in Regulatory Guide 1.14 7 [3]. The single condition deals with a requirement to perform the repair or replacement activity, temporarily deferred, during the next scheduled outage. Since the introduction of this Code Case, many utilities have used it as a basis for continued operation of degraded piping in moderate energy systems and that has resulted in significantly fewer relief requests to the NRC. Consequently, the industry has benefited from substantial cost savings while maintaining safety. To date, there have been no known instances where the use of the Code Case has resulted in any safety issues in the industry. The scope of Code Case N-513-3 is limited to straight pipe with some provision for flaw evaluation into fittings for a short distance from the weld attachment to straight pipe. There have been many instances where through-wall leaks have been observed in pipe components (i.e., elbows, reducers, expanders or branch tees) or bent pipe outside of the current Code Case scope. As a result, utilities are forced into taking alternate actions (e.g., repair, replacement or making requests for NRC relief) that can be significantly more burdensome without any measurable increase in plant safety. Code Case N-513-4 provides evaluation rules and criteria for the temporary acceptance of flaws for these instances. In addition, other enhancements are included with the fourth revision as described herein. Background of Moderate Energy Definition The genesis of Code Case N-513 was NRC Generic Letter (GL) 90-05 [4]. Prior to Code Case N-513, this GL was the only available guidance for plants regarding operational leakage in moderate energy piping. The definition of moderate energy piping in Code Case N-513 is consistent with GL 90-05. The scope of GL 90-05 is limited to Class 3 piping, but does address moderate and high energy systems. While non-code repairs are allowed by GL 90-05 (with NRC review) for the temporary period of operation prior to Code compliant repair/replacement, an additional requirement for the repair having load-bearing capability is necessary for high energy pipe applications. Both GL 90-05 and the latest approved revision of Code Case N-513 are identified as methods available to evaluate the structural integrity of piping with discovered leakage in the NRC Inspection Manual [5]. The definition of moderate energy (the 200°F and 275 psig limits) was first introduced in a NRC letter from A. Giambusso to licensees in 1972 to address postulated piping breaks in fluid

Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 25 of 33 systems outside containment (discussed in the Branch Technical Position 3-3 of the current Standard Review Plan [6]). The importance of the 200°F temperature limit being below the boiling point of water at atmospheric pressure is clear in the definition of moderate energy piping. However, the basis for the pressure limit of 275 psig is less evident. In conversations with the NRC, there appears to be a link between the 275 psig limit and the recommended working pressure limit for Class 150 pipe flanges and flanged fittings given in the ASME Bl6.5 standard [7]. This basis is not known to be documented. A technical approach and basis are presented herein to justify the scope expansion of Code Case N-513-4 to a higher pressure limit. The Class 3 RHRSW system at Cooper has a design pressure of 490 psig [8]. It is desired to expand the scope of N-513-4 such that it may be generically applied to this specific system as it has experienced part-wall degradation in the past. TECHNICAL BASIS FOR ALTERNATE USE OF ASME CODE CASE N-513-4 Summary of Code Case N-513-4 Changes The list below summarizes the major differences between the NRC-approved Code Case N-513-3 and Code Case N-513-4. Note that a brief reason for each change is included in parenthesis. Temporary acceptance period redefined from no longer than 26 months to the next refueling outage (addresses NRC condition given in Regulatory Guide 1.14 7) Flaw evaluation criteria included for elbows, bent pipe, reducers, expanders and branch tees (scope expansion) Allow flaw evaluation of heat exchanger tubing in specific instances (scope expansion) Daily walkdown requirement for through-wall leaks provides additional flexibility for user implementation (scope expansion) Limit scope to only liquid systems (scope clarification) Treatment of Service Level load combinations (scope clarification) Treatment of flaws in austenitic pipe flux welds (scope clarification) Minimum wall thickness acceptance criteria to consider longitudinal stresses in addition to hoop stress (scope clarification) In addition, several editorial changes to improve the clarity of the Code Case are included. A detailed markup of Code Case N-513-3 showing all of the changes made for Revision 4 is provided in Attachment l. Technical Basis The technical basis for the changes listed above is given in an ASME Pressure Vessel and Piping (PVP) conference paper [9] and is provided in Attachment 2.

Precedents Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 26 of 33 There have been several submittals approved for N-513-4 use in specific applications and for generic use by Exelon. The table below lists several Safety Evaluation Reports as precedents for use of Code Case N-513-4. Table 1: Code Case N-513-4 Precedents SER Accession No. Plant Application Additional Requirements ML16230A237 Exelon Fleet Generic N-513-4 Critical leakage determination ML15070A428 ANO Leaking sweepolet 5 gpm leakage limit ML14316Al67 Fort Calhoun Leaking elbow None ML14335A55 l Peach Bottom Leaking elbow 5 gpm leakage limit TECHNICAL BASIS FOR CODE CASE N-514-4 SCOPE EXPANSION TO IDGHER PRESSURE LIMIT The technical approach includes several elements that support the following objectives: (i) show NRC precedent in approving relief requests for through-wall leakage in piping or components operating at high energy, (ii) show that structural integrity is not overly impacted when comparing flaw evaluations between piping systems operating at 275 and 490 psig, and (iii) show that possible jet thrust forces resulting from leaking flaws are not of concern. An outline of the technical basis detailing the elements used to support these objectives follows: Review of Relevant NRC Approved Relief Requests Structural Integrity Evaluation o Design minimum wall thickness comparison o Code Case N-513-4 allowable flaw size comparison o Code Case N-513-4 cover thickness requirement comparison Jet Thrust Force Evaluation Note that the evaluation rules and acceptance criteria of Code Case N-513-4 are not limited by pressure and remain valid for the higher limit of 490 psig. Review of Relevant Relief Requests A detailed search of the NRC ADAMS database was conducted to identify any relief requests for continued operation of degraded high energy piping or components. The search results are summarized in Table 2.

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 27 of 33 Table 2: Summary of Relevant Relief Requests ADAMS Plant I Operating Accession Description Status Number Condition ML072140851 McGuire, Ul I Application for continued Approved 2,500 psig operation of leaking valve San Onofre U2, Generic application for continued ML101440381 U3 I< 275 psig operation of high temperature Approved (275° F) through-wall leaking pipe ML15043A496 Exelon Plants I Generic request to use Code Case Approved* 375 psig N-513-3 at a higher pressure limit

  • In add1t1on to the N-513-3 requirements, the NRC imposed an allowable leak rate limit of 5 gpm.

Structural Integrity Evaluation Design minimum wall thickness comparison ASME B31. l [ 1 O] defines the design minimum wall thickness required for pressure loading, tm, as (without a corrosion allowance): where: p Do s t = p0o m 2(S+0.4p) Design pressure Outside pipe diameter Material allowable stress. (1) Substituting maximum operating pressure for design pressure in Equation 1, the minimum required wall thickness increases 77% with an increase in pressure from 275 to 490 psig. While this percentage increase appears significant, the actual change in minimum required wall thickness is relatively low as the hoop stress at these pressures is small. Table 3 shows a comparison of minimum wall thicknesses for various pipe sizes. Table 3: Minimum Required Wall Thickness Comparison Nominal Pipe Size tmin for 275 psig* (in) tmin for 490 psig* (in) 6-inch 0.053 0.094 12-inch 0.102 0.181 18-inch 0.144 0.255

  • A material allowable stress of 17.1 ksi is assumed.

Code Case N-513-4 allowable flaw size comparison Attachments 1 - 3 RRS-03 Cooper Nuclear Station Page 28 of 33 Code Case N-513-4 allows for nonplanar, through-wall flaws to be evaluated as two independent planar through-wall flaws, one orientated in the axial direction and one orientated in the circumferential direction (i.e., a planar flaw characterization approach). The Code Case acceptance criteria require the flaw region be bounded by the area defined by the allowable axial and circumferential flaw sizes. Several example N-513-4 calculations were conducted illustrating the influence of higher pressure on allowable flaw size. Following the Code Case guidance, a linear elastic fracture mechanics (LEFM) evaluation was performed for various carbon steel pipe sizes to determine the maximum allowable flaw sizes at maximum operating pressures of 275 and 490 psig. Table 4 summarizes the results and several notes are provided giving more details regarding the analysis inputs. The influence of the higher pressure is clearly seen and a greater impact is observed in the axial direction as expected since pressure hoop stress is twice the axial membrane stress due to pressure. While the higher pressure does decrease the allowable flaws sizes, the effect does not impact the functionality or validity of the Code Case approach. Table 4: Allowable Axial and Circumferential Flaw Size Comparison Nominal Axial Direction (in) Circumferential Direction (in) Pipe Size 275 psig 490 psig %~ 275 psig 490 psig %~ 6-inch Mb = 40 3.1 1.9 39% 2.8 2.1 25% in-kips 12-inch Mb = 170 3.0 1.5 50% 3.3 2.1 36% in-kips 18-inch Mb = 260 2.2 0.9 59% 3.3 1.8 44% in-kips Notes: - Piping material assumed Al06 Grade B; standard schedule thickness. - Applied bending moment for each pipe size results in a stress ratio of about 0.25 at 275 psig. - Allowable flaw sizes based on Service Level B structural factors. - Analysis based on a conservative lower shelf toughness value of 45 in-lb/in2* Code Case N-513-4 cover thickness requirement comparison Code Case N-513-4 provides a branch reinforcement method to evaluate nonplanar, through-wall flaws. As part of the branch reinforcement approach, an opening is modeled such that its diameter fully bounds the leaking flaw. In practice, there could exist a remaining wall ligament within the modeled opening. Equation 9 of Code Case N-513-4 provides assurance against pressure blowout (i.e., wall ligament failure) by requiring an average cover thickness, tc,avg, within the modeled opening:

where: dactj p s tc,avg 2::: 0.353dadjJ% Modeled opening diameter Maximum operating pressure Material allowable stress. Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 29 of 33 (2) The average cover thickness requirement increases about 33% with an increase in maximum operating pressure from 275 to 490 psig. Figure 1 illustrates the average cover thickness required as a function of adjusted diameter for 275 and 490 psig. Note that a material allowable stress of 17.1 ksi is assumed. Typically, modeled openings have a diameter < 1 inch and the change in the required cover thickness is small(< 15 mils). 0.10 0.09 0.08

.§. 0.07 275 psig Q)

~ 0.06 490 psig u ..c f-(jj 0.05 0 u " 0.04 ~

i fil' 0.03 a:::

0.02 0.01 0.00 0 0.25 0.5 0.75 1 Adjusted Diameter (in) Figure l : Required Cover Thickness vs. Adjusted Diameter for 275 and 490 psig

L Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 30 of 33 Jet Thrust Force Evaluation Part 3.6.2 of the NRC Standard Review Plan [11] provides a simplified dynamic analysis model to quantify the jet thrust force, T, of water from a pipe break. The following equation is given: T=KpA (3) where: K p A Thrust coefficient (2.0 for subcooled, nonflashing water) System pressure prior to pipe break Pipe break area. Figure 2 shows a comparison of jet thrust force for pressures of 275 and 490 psig over a range of through-wall opening diameters. For small through-wall opening diameters(< 0.5 in), the difference in the jet thrust force is small. It is unlikely larger openings would be tolerated by the plant as this would result in excessive leakage and possibly impact system operability or room flooding abatement. 800 700 600 275 psig 500 490 psig .0 QI u 400 0 u.. QI 300 200 100 0 0 0.25 0.5 0.75 Through-Wall Hole Diameter (in) Figure 2: Jet Force vs. Through-wall Hole Diameter for 275 and 490 psig 1

ADDITIONAL REQUIREMENTS Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 31 of 33 Implementation of Code Case N-513-4 requires additional actions be satisfied by the plant including observing leakage daily to confirm analysis conditions used in the evaluation remain valid, frequent periodic inspections to track flaw growth and augmented examinations to assess degradation of the affected system. Furthermore, the following additional requirements are included as part of the Relief Request in order to bolster defense-in-depth and avoid adverse consequences:

1. For a leaking flaw, the allowable leakage rate will be determined by dividing the critical leakage rate by a safety factor of four ( 4). The critical leakage rate is determined as the maximum leakage rate that can be tolerated. The critical leakage rate may be based on the allowable loss of inventory or the maximum leakage that can be tolerated relative to room flooding, among others. The safety factor of four to the critical leakage rate is believed adequate to ensure system operability and allow for early identification of conditions that may lead to adverse consequences. This requirement is consistent with a previous NRC Relief Request Safety Evaluation for the Exelon fleet [12] to generically use Code Case N-513-4.
2. The number of augmented examination locations shall be increased from 5 (current number in Code Case N-513-4) to 10. This is consistent with the NRC Generic Letter 90-05 [4] requirement for high energy Class 3 applications.
3. For leakage rates greater than 5 gpm, the leakage shall be stopped throughout the temporary acceptance period by the use of engineered mechanical clamping designed by Cooper. The engineered mechanical clamping design shall be sufficient to withstand the maximum operating pressure and removable such that the frequent periodic inspections defined in paragraph 2(e) ofN-513-4 may be performed.

CONCLUSIONS This attachment provides a technical basis for proposed alternative use of ASME Section XI Code Case N-513-4 and its scope expansion to a higher pressure limit from 275 to 490 psig for the Cooper Nuclear Station, specific to the RHRSW system. The discussion provided herein demonstrates that the use of Code Case N-513-4 with the higher pressure limit will reduce plant burden without any adverse effect on safety. The technical basis is comprised of four primary elements. First, Attachment 2 provides the technical basis for the new content and evaluation methods in Code Case N-513-4 including those for flaw analysis in piping components such as elbows, reducers and branch tees. Second, relevant NRC relief requests were reviewed. They demonstrate that there is precedent for the temporary acceptance of leaking flaws in Class 2/3 piping and components at pressures higher than 275 psig. Third, a structural integrity evaluation was performed to determine the impact of the increased pressure on design minimum wall thickness, N-513-4 allowable flaw sizes and the N-513-4

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 32 of 33 cover thickness requirement. While the influence of the higher pressure was observed in the evaluation, structural integrity can still be demonstrated. The functionality and validity of the Code Case methods at higher pressure were confirmed. Finally, jet thrust forces were estimated for a leaking pipe at 275 and 490 psig. A significant change in jet thrust forces was only seen with large opening areas that would result in high leak rates, i.e., rates that would challenge system functionality or local spray and/or compartment flooding requirements. As part of the generic Relief Request, several additional requirements are introduced in order to bolster defense-in-depth. They include expanding the number of augmented inspection locations from 5 to 10, introducing a limit on discovered leakage and requiring the leakage be stopped during the temporary acceptance period. REFERENCES

1.

ASME Code Case N-513-4, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division I," Cases of the ASME Boiler and Pressure Vessel Code, May 7, 2014.

2.

ASME Code Case N-513-3, "Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division I," Cases of the ASME Boiler and Pressure Vessel Code, January 26, 2009.

3.

Regulatory Guide 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division I," Revision 17, August 2014.

4.

NRC Generic Letter 90-05, "Guidance for Performing Temporary Non-Code Repair of ASME Code Class I, 2, and 3 Piping," (June 15, 1990).

5.

NRC Inspection Manual, Chapter 0326, "Operability Determinations & Functionality Assessments for Conditions Adverse to Quality or Safety," Issue Date: 12/03/ 15.

6.

NRC Standard Review Plan, NUREG-0800, Branch Technical Position 3-3, "Protection Against Postulated Piping Failures in Fluid Systems Outside Containment," Revision 3, March 2007.

7.

American National Standard, "Pipe Flanges and Flanged Fittings," ASME B 16.5-2003.

8.

Nebraska Public Power District Design Calculation No. NEDC 02-051, Revision 1, "Design Temperature Determination for SW, CW, WW, & CS Piping; Design Pressure Determination for SW-I piping," September 17, 2002, SI Fi le No. 1700405.20 I.

9.

McGill, R.O., Cipolla, R.C., DeBoo, G. and Houston, E.J., "Technical Basis for Proposed Fourth Revision to ASME Code Case N-513," Proceedings of the ASME 2014 Pressure Vessels & Piping Conference, PVP2014-28355.

10. USA Standard, USAS 831.1.0, "Power Piping," 1967 Edition.
11. NRC Standard Review Plan, NUREG-0800, Part 3.6.2, "Determination of Rupture Locations and Dynamic Effects Associated with the Postulated Rupture of Piping,"

Revision 2, March 2007.

Attachments 1 - 3 RR5-03 Cooper Nuclear Station Page 33 of 33

12. NRC Relief Request Approval and Safety Evaluation Report for Exelon Generation Company Fleet Request for Proposed Alternative to Use ASME Code Case N-513-4, ADAMS Accession No. ML16230A237.}}