Independent Spent Fuel Storage Installation - General License 30-day Cask Registration Notification and Thermal Performance Assessment
ML17233A176
Person / Time
Site: 07201004, Nine Mile Point  
(DPR-063, NPF-069)
Issue date: 08/07/2017
From: Moore D
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
NMP1L 3173
Download: ML17233A176 (2)


Text

Exelon Generation NMP1L 3173 August 7, 2017 U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTN: Document Control Desk 10 CFR 72.212(b)(2)

Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Nine Mile Point Nuclear Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-63 and NPF-69 Docket Nos. 50-220 and 50-41 O Nine Mile Point Nuclear Station Independent Spent Fuel Storage Installation General License Docket No. 72-1036 7 Z -/ b b Lf

SUBJECT:

General License 30-day Cask Registration Notification and Thermal Performance Assessment Pursuant-to the requirements of 1 O CFR 72.212(b)(2), this letter provides the information to register the use of one approved spent fuel storage cask at the Nine Mile Point Nuclear Station (NMPNS) Independent Spent Fuel Storage Installation (ISFSI).

Licensee's Name:

Address:

Reactor License Numbers:

Docket Numbers:

Person Responsible for Providing additional information:

Cask Certificate Number:

Certificate Amendment Number:

Cask Model Number:

Cask Identification Numbers:

Nine Mile Point Nuclear Station, LLC PO Box 63 Lycoming, NY 13093 DPR-63 and NPF-69 50-220, 50-410 and 72-1036 Mr. Kenneth J. Kristensen 315-349-2069 1004 10 NUHOMS-61 BTH NMP-61BTH-1-A-2-037, loaded July 8, 2017 The Technical Specifications (TS) for Certificate of Compliance (CoC) No. 1004, Amendment No. 10, § 1.1. 7 "Special Requirements for First System in Place", requires the results of the temperature measurements of the first Dry Shielded Canister (DSC) placed in service be submitted to the NRC for evaluation and assessment. Additionally, this section of TS requires subsequent users of the system to report heat loads higher than the first user. The first user of the NU HOMS CoC No. 1004, Duke Energy, submitted the heat transfer characteristics for an 18.95 kilowatt (kW) Dry Shielded Canister (DSC) in a letter to the NRC, from Duke Energy, "Cask Certificate of Compliance, Docket No.: 72-1004, 30-day Report for Higher Canister Heat Loading per General Requirement Section 1.1.7," dated August 8, 2007 (ML072340622). The

I

µ!Vf 5 5 2-'T jJfl4S~ Z~

30 Day Cask Registration August7,2017 Page2 first DSC loaded at NMPNS had a heat load *of 7.30 kW, as reported in our letter dated October 17, 2012.

A summary of the thermal performance of DSC 37 in place at the NMPNS ISFSI is submitted for your information.

Horizontal Storage Module (HSM) Model:

NU HOMS Model 102 HSM Identification Number:

Cask:

Calculated Heat Load:

Calculated !::. T:

Actual !::. T (Note 1):

7DFS-HSM0021 NMP-61 BTH-1-A-2-037 8.383 kW 45 degrees F 31.5 degrees F Note 1: The actual !::. T represents the measured !::. T obtained during equilibrium conditions.

Equilibrium conditions were achieved when the daily temperature change observed was less than 6 degrees F over three consecutive days.

This letter contains no NRG commitments.

Should you have any questions regarding the information in this submittal, please contact Ken Kristensen at (315) 349-2069.

Sincerely, Dennis M. Moore Regulatory Assurance Manager, Nine Mile Point Nuclear Station Exelon Generation Company, LLC DMM/KJK cc: