ML17222A738

From kanterella
Jump to navigation Jump to search
Advises That Visual Insp of Pressurizer Surge Line for Unit 2 Complete & No Gross Discernible Distress or Structural Damage Identified in Line,Per NRC Bulletin 88-011
ML17222A738
Person / Time
Site: Saint Lucie  
Issue date: 04/04/1989
From: Conway W
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-88-011, IEB-88-11, L-89-91, NUDOCS 8904170297
Download: ML17222A738 (3)


Text

A,C CKMPATED Dl BUIl0~

DEMONi T105 SYSTEM RECIPIENT ID CODE/NAME PD2-2 LA NORRIS,J INTERNAL: AEOD/DOA NRR CHAN,T NRR KADAMBI,P NRR/DEST/ADE 8H NRR/DEST/MEB 9H NRR/DOEA/GCB 11 N

S ILRB12 G

02 RGK FILE 01 COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD2-2 PD AEOD/DSP/TPAB NRR HOU,S NRR KUO,P NRR/DEST/ADS 7E NRR/DOEA/EAB 11 NRR/DREP/EPB 10 NUDOCS-ABSTRACT RES/DSIR/EIB COPIES LTTR EN 1

CL REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8904170297 DOC.DATE: 89/04/04 NOTARIZED: YES FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power

& Light Co.

50-389 St. Lucie Plant, Unit 2, Florida Power

& Light Co.

AUTH.NAME

'UTHOR AFFILIATION CONWAY,W.F.

Florida Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Advises th'at visual insp of pressurizer surge line for Unit 2 complete,per Bulletin 88-011.

DISTRIBUTION CODE:

IE30D COPIES RECEIVED:LTR I

ENCL 0 SIZE:

TITLE: Bulletin 88-11 Pressurizer Surge Line Thermal Stratification NOTES:

DOCKET 05000335 05000389 S

h D

D 8

EXTERNAL: LPDR NSIC NRC PDR D

NClIE 'IO ALL "RIES" ~~IPIE2GS:

PEZAS HELP US 'IO REDUCE WASTE!

02iTACT 'IHE DOCU~i'7 CGNIROL DMK, RXY. Pl-37 (EÃi'. 20079) IO ELOCUTE HER NAME FRY DISTRIBUTION LISTS FOR DOCUtKNl'S YOU MN'T NEEDz D

S TOTAL NUMBER OF COPIES REQUIRED'TTR 23 ENCL k

P..

ox14000,Juno Beach, FL 33408-0420 AP.RIL' 1989 L-89-91 10 CFR 50.54(f)'.

S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Re:

St. Lucie Unit Nos.

1 and 2

Docket Nos.

50-335 and 50-389 NRC Bulletin 88-. 11 Pressurizer Sur e Line Thermal Stratification Per NRC Bulletin 88-11, Florida Power

& Light Company (FPL) was requested to conduct a visual inspection (ASME,Section XI, VT-3) of the St.

Lucie Plant pressurizer surge lines at the first available cold shutdown which exceeds seven days (Action Requested 1.a.).

Additionally, it was requested in. the bulletin that FPL report any discernable distress and damage observed during the visual inspection of Action Requested 1.a.,

along with corrective actions taken or plans and schedules for repair before restart of the units.

St.

Lucie Unit 2

was shutdown in January,,

1989 for a refueling outage.

The visual inspection of the pressurizer

.surge line has been completed at St.

Lucie Unit 2

and no gross discernable distress or structural damage was identified in the line.

St.

Lucie Unit

.1 will complete the visual inspection as required by the subject bulletin at the first available planned cold shutdown which exceeds 7 days.

Please contact us if there are any questions.

Very truly yours, W.

Con y

Senior Vi e President Nuclear WFC/MSD/cm cc:

Stewart D. Ebneter, Reg'ional Administrator, Re'gion II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant

MSDPSLTS, 904170297 8+0404 F'DR AOOCK 05000335 O

PDC

STATE OF-FLORl'DA

)

)

ss.

COUNTY OF PALM BEACH

)

W. F. Conwa being first duly sworn, deposes and says:

That he is 'enior Vice President-Nuclear of Florida Power & Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this, document are true and correct to the best of his knowledge, information, and

belief, and that he is authorized to, execute the document on behalf of said License e.

~ Fo way Subscribed and sworn to before me this doy of ~, 198 9.

NOTARY PUBLIC, in and for the C nty of Palm Beach, State of Florida My Commission expi es; p>bfl Qll,& of I;1,'I'8'f i'y'