ML17222A307

From kanterella
Jump to navigation Jump to search
Amend 96 to License DPR-67,revising Valve Tag Numbers, Penetration Numbers & Valve Types in Util Tech Spec Table 3.6-1, Containment Leakage Path & Table 3.6-2, Containment Isolation Valves
ML17222A307
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 06/16/1988
From: Berkow H
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17222A308 List:
References
NUDOCS 8806290209
Download: ML17222A307 (12)


Text

~

~pg ACCT Wp O~

Cy 00 IVl V/+o ++*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, O. C. 20555 FLORIDA POHER 5 LIGHT COMPANY DOCKET NO. 50-335 ST.

LUCIE PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATIIIG LICENSE Amendment No.

96 License No.

DPR-67 I.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

. The application for amendment by Florida Power 5 Light Company, (the licensee) dated August 25, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

880b290209 880hih PDR ADQCK 05000335 PDR

I C

1

2.

Accordingly, Facility Operating License No.

DPR-67 is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and by amending paragraph 2.C.(2) to read as follows:

(2)

Technical S ecifications The Technical Specifications contained in Appendices A

and B, as revised through Amendment No. 96

, are hereby incorporated in the license.

The licensee shall operate the faci'lity in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLE RE ULATORY COHliISSION erbert

. Berkow,'irector Projec irectorate II-2 Divisi of Reactor Projects-I/II Office of Nuclear Reactor Regulation

Attachment:

Charges to the Technical Specifications Date of Issu'ance:

June 16, 1988

I f

l

/g ATTACHMENT TO LICENSE AMENDMENT NO. 96 TO FACILITY OPERATING LICENSE NO. DPR-67 DOCKET NO. 50-335 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed. pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of 'change.

The corresponding overleaf pages are also provided to maintain document com-pleteness.

Remove Paqes 3/4 6-5 3/4 6-6 3/4 6>>7 3/4 6-8

'/4 6-21 3/4 6-22 Insert Pa es 3/4 6-5 3/4 6-6 3/4 6-7 3/4 6-8 3/4 6-21 3/4 6-22

~

~

'1 t

t~

I r

Penetration 10 23 25

~Se tete Hakeup Hater Station Air Instrument Air Containment Pur ge Containment Purge llaste tianagement Component Cooling Component Cooling Fuel Transfer Tube TABLE 3.6-1 CONTAIN!1ENT LEAKAGE PATHS Val ve Ta Number Gate (I-NV-15-1)

Check

( I-V-15328)

Globe (I-V-18-947)+

Globe (I-V-18-947)++

Check (I-V-181118)+++

Globe (I-SH-18797)++>

Gate

( I-liV-18-1)

Check (I-V-18195)

Butterfly (I-FCV-25-4)

Butterfly (I-FCV-25-5)

Butterfly (I-FCV-25-3)

Butterfly I-FCV-25-2 Globe (V-6741)

Check (V-6779)

Butterfly (I-HCV 14-7)

Butterf1'y (I-HCV-14-1)

Butterfly (I-HCV-14-6)

Butterfly (I-HCV-14-2)

Double Gasket Flange to Location Containment Outside Inside Outside Outside Inside+++

Annulus~++

Outside Inside Inside Outside Inside Outside Outside Outside Outside Outside Outside Outside Inside e

I Service Test'~e*

Primary tiakeup l!ater Bypass Station -Air Supply Bypass Containment Purge Exhaust Containment Purge Supply Nitrogen supply to SI Tanks RC Pump CW Supply RC Pump Cl< Return Fuel Transfer Type C

Type C

Bypass Bypass Bypass Bypass 4

Instrument Air Supply Bypass I.

26 28 CVCS Sampl ing Globe (V-2515)

Globe (V-2516)

Globe (V'-5200)

Globe (V-5203)

Globe (I-FCV-03-1E)

Globe (I-FCV-03-1F)

Inside Inside Outside Outside Outside Outside Letdown Line Reactor Coolant Sample SI Tank Sample SI Tank Sample Bypass Bypass Bypass 4To become I-HCV-18-2 upon completion of the modification described in L-87-123.

+~To become I-V-18795 upon completion of the modification described in L-87-123.

+++To become effective upon completion of the modification described in L-87-123.

TABLE 3.6-1 Continued 29 Sampling Penetration

~S stem 29 Sampling Valve Ta Number Globe (V-5202)

Globe (V-5205)

Globe (V-5201)

Globe V-5204)

Location to Containment Outside Outside Outside Outside Service Pressurizer Steam Space Sample Pressurizer Surge Line Sample Test

~Te+

Bypass Bypass 31 Waste Management Gate (V-6554)

Gate V-6555)

Outside Outside Containment Vent Header Bypass Safety Injection Gate V-3463)

Tank Test Lines Gate I-Y-07009)

Outside Outside Safety Injection Tank Bypass Fill and Sampling 43 46 47 48a Waste Management Waste Management CVCS Fuel Pool Cleanup Fuel Pool Cleanup Sampling Gate (I-LCV-07-.11A)

Gate

( I-LCV-07-11B)

Gate (V-6301)

Gate (V-6302)

Gate (V-2505)

Gate (I-SE-Ol-l)

Gate (I-V-07-206)

Gate (I-V-07-189)

Gate

( I-V-07-170)

Gate (I-V-07-188)

Globe

( I-FSE-27-1, 2, Globe (I-FSE-27-8)

Outside Outside Outside Outside Outside Inside Outside Inside Outside Inside Inside Outside Reactor Cavity Sump Pump Discharge Reactor Drain Tank Pump Suction RC Pump Controlled Bleedoff Refueling'avity Purification Flow Inlet Refueling Cavity Purification Flow Outlet H2 Sampling Bypass Bypass Bypass Bypass Bypass Type C

~

~,

ss Penetration

~S stem TABLE 3.6-1 Continued Location Valve Ta Number to Containment Service Test

~Te*

48 c Sampl ing Globe

( I-FSE-27-11)

Check (I-V-27101)

Outside Inside H2 Sampling Type C

51c 5la 52a 52b 52c 52d 52e 54 Sampling Sampling Sampling Sampling Sampling ILRT ILRT ILRT Globe (I-FSE-27-5,6,7)

Globe (I-FSE-27-9)

Globe (I-FSE-27-10)

Check (I-V-27102)

Gate (I-FCV-26-1)

Gate (I-FCV-26-2)

Gate (I-FCV-26-3)

Gate (I-FCV-26-4)

Gate I-FCV-26-5)

Gate I-FCV-26-6 Globe (I-V00140)

Globe (I-V00143)

Globe (I-V00139)

Globe (I-V00144)

Blind Flange Gate (I-V00101)

Inside Outside Outside Inside Inside Outside

-Inside Outside Inside Outside Inside Outside Inside Outside Inside Outside H2 Sampling H2 Sampling Radiation Monitoring Radiation Monitoring Radiation Monitoring Return ILRT Test Tap ILRT Test Tap ILRT Pressure Connection Type C

Type C

Bypass Bypass Bypass Bypass Bypass Bypass 57 Containment H2 Purge Containment H2 Purge Gate (I-V-25-11)

Gate I-V-25-12)

Gate (I-V-25-13)

Gate (I-V-25-14)

Outside Outside Outside Outside Hydrogen Purge Outside Bypass

.Air Makeup Hydrogen Purge Exhaust Bypass

Penetration

~S stem TABLE 3.6-1 Continued Location P

Service Test e*

58 Containment H2 Purge Gate (I-V-25-15)

Gate (I-V-25-16)

Outside Outside Hydrogen Purge Exhaust Bypass 67 68 Personnel Lock Vacuum Relief Vacuum Relief N.A.

Check (I-V-25-2O)

Butterfly (I-FCV-25-7)

Check (I-V-25-21)

Butterfly (I-FCV-25-8)

None Inside Outside Inside Outside N.A.

Containment Vacuum Relief Containment Vacuum Relief Ingress

& Egress to Containment Type C

Type C

Type 8**

~ h Escape Lock N.A.

None N.A.

Emergency Ingress Type 8**

Egress to Containment Maintenance Hatch N.A.

None N.A.

Vessel Maintenance Type 8 (Gasket Interspace)

Electrical N.A.

Penetrations All primary canisters and flanged electrical penetrations except welded spares N.A.

Electrical connections in PCV Type 8 Hain Steam Steel Containment Nozzles Hain Steam Steel Containment Nozzles Tap 1

Tap 2

Tap 1

Tap 2

Outside Outside Expansion Bellows Outside Expansion Bellows Outside Type 0

Type B

, r.

P P

h r'

Ph Feedwater Steel Tap 1

Containment Nozzles Tap 2

Outside Expansion Bellows Outside Type 8

Valve Ta Number B.

MANUAL OR REMOTE MANUAL 1.

I-V-18-947+

2.

I-V-25-11,12 3.

I-V-25-13,14, 15,16 4.

V-3463 5.

I-V-07009 6.

V-07206, V-07189 7.

V-07170, V-07188 Penetration Number 56 57

& 58 41 41 TABLE 3.6-2 Continued Function Station air supply, Manual Hydrogen purge outside air make-up, Manual (NC)

Hydrogen purge exhaust, Manual (NC)

Safety injection tank test line, Manual (NC)

Safety injection tank test line, Manual (NC)

Refueling cavity purification flow inlet, Manual (NC)-

Refueling cavity purification flow outlet, Manual (NC)

Testable During Plant 0 eration Yes Yes Yes Yes Yes Yes Yes Isol ati on Time Sec NA NA NA NA" NA

?

?,

~

I-FSE-27-1,2,3, 4,8,11 9.

I-FSE-27-5,6,7, 9,10 48a Hydrogen sampling line, Remote 48c manual 5la Hydrogen sampling line, Remote 5lc manual Yes Yes NA+

+To become I-'V-.18795 upon completion of the modification described in L-87-123.

In m

Valve Ta Number 10.

I-FCV-26-1 & 2 11.

I-FCV-26-3 8 4 12.

I-FCV-26-5 5 6 13.

I-V00140 I-V00143 14.

I-V00139 I-V00144 15.

I-V00101 16.

I-FCV-03-lE 5 1F Penetration Number 52a 52b 52c 52d 52e 28 TABLE 3.6-2 Continued Function Radiation moni toring Radiation monitoring Radiation monitoring, return ILRT test tap ILRT test tap ILRT pressure connection SI Tank Sample Testable During Plant 0 eration Yes Yes Yes Yes Yes Yes Yes Isolation Time Sec NA NA NA NA NA - Hanual Valve-Isolation time not applicable.

Hay be opened on an intermittent basis under administrative control.

Normally closed valves - Isolation time not applicable.

O