ML17221A633
| ML17221A633 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 02/19/1988 |
| From: | Woody C FLORIDA POWER & LIGHT CO. |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| L-88-81, NUDOCS 8802240193 | |
| Download: ML17221A633 (4) | |
Text
asC ACCELERATED DISI'RIBUTION DEMONSTRATION SYSTEM RECIPIENT ID CODE/NAME PD2-2 PD COPIES LTTR ENCL 1
1 RECIPIENT ID CODE/NAME TOURIGNY,E COPIES LTTR ENCL 2
2 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:8802240193 DOC.DATE: 88/02/19 NOTARIZED: NO
~
~
~
~
~
~
CIL:50-335 St. Lucie Plant, Unit 1, Florida Power
& Light Co.
50-389 St. Lucie Plant, Unit 2, Florida Power
& Light Co.
UTH.NAME AUTHOR AFFILIATION MOODY,C.O.
Florida Power
& Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Responds to violations noted in Insp Repts 50-335/87-25 50-389/87-24.Corrective actions:procedure revised.
DISTRIBUTION CODE: IEOID COPIES RECEIVED:LTR~ ENCL~ SIZE:
TITLE: General (50 Dkt)-Insp Rept/Notice of Vino ation Response NOTES DOCKET 05000335 05000389 R
D S
INTERNAL: ACRS DEDRO NRR/DLPQ/PEBllB NRR/DOEA DIRllE NRR/DREP/RPB10A NRR/PMAS/ILRB12 OGC 15-B-18 RES/DRPS DIR RNAL: LPDR NSIC 2
2 1
1 1
1 1
1 2
2 1
1 1
1 1
1 1
1 1
1 AEOD NRR MORISSEAU,D NRR/DLPQ/QAB10A NRR/DREP/EPB10D NRR/DRIS DIR9A2 IEBERMAN,J RGN2 FILE 01 NRC PDR 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 A
1 A
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 24 ENCL 24
P. O. BOX 14000, JUNO BEACH, FL 33408 0420 FEBRUARY 4 9 1988 L-88-81 10 CFR 2.201 U. S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, D.
C.
20555 Gentlemen:
Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 Ins ection Re ort 335 87-25 and 389 87-24 Florida Power Light Company has reviewed the subject inspection
- report, and pursuant to the provision of 10 CFR 2.201, the response is attached.
Very truly yours, C.
O.
W y
Executi e Vice President COW/EJW/gp Attachment cc:
Dr. J.
Nelson Grace, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant GRM/016. IR 8802240i93 880219 PDR aDaCK 050O0ZZ5
,0 DCD I I an Fpk Gr 1.p company
ATTACHMENT FINDING:
During the Nuclear Regulatory Commission (NRC) inspection conducted on November 1
December 5,
- 1987, a violation of NRC requirements was identified.
The violation involved entering an operational mode without the necessary limiting conditions for operation (LCO) being met.
In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions,"
10 CFR Part 2, Appendix C (1987),
the violation is listed below:
Unit 1 Technical that entry into made unless the (LCO) are met contained in the expected.
Specification (TS) 3.0.4 requires an operational mode shall not be limiting conditions for operation without reliance on provisions action statement, unless otherwise Contrary to the above, on October 14, 1987, Unit 1 entered Mode 4 from Mode 5 without the conditions of LCO 3.6.6.2 being met.
Shield building integrity was not being maintained due to a door that was left open and unattended.
RESPONSE
1.
Florida Power Light Company concurs with the violation.
2.
Procedural deficiency and personnel error in paperwork review by the operators involved were the cause of the finding.
3.
Shield Building integrity was immediately established.
The shift was conuseled on the need for an accurate and thorough review of shift paperwork prior to mode changes.
Additionally, shift meetings were held by the Operations Supervisor on November 30,
- 1987, December 7,
- 1987, and January 19,
- 1988, to discuss the details of this report.
The need for thoroughness and accuracy in review of paperwork and operator responsibilities was also emphasized.
4 ~
OP1-0030120, Pre-start Check-Off, will be
- revised, adding a
sign-off signifying that vital areas are revitalized prior to entry into Mode 4.
This will ensure that the Shield Building door and all similar areas are locked or controlled prior to required mode changes.
5.
Implementation of these measures will be completed by March 31, 1988.
GRM/016.IR