ML17221A503
| ML17221A503 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 11/12/1987 |
| From: | Tourigny E Office of Nuclear Reactor Regulation |
| To: | Woody C FLORIDA POWER & LIGHT CO. |
| Shared Package | |
| ML17221A504 | List: |
| References | |
| TAC-66367, NUDOCS 8711200147 | |
| Download: ML17221A503 (4) | |
Text
/
1 Docket No. 50-389 November 12, 1987 Mr. C. 0.
Moody Group Vice President Nuclear Fnergy Florida Power and Light Company P.O.
Box 14000 Juno Beach, Florida 33408
Dear Mr. 11Ioody:
SUBJECT:
LARGE BREAK LOCA REANALYSIS (TAC k'66367)
In your letter dated August 25, 1987, you pr ovided the results of the St.
Lucie Plant, Unit 2 large break LOCA reanalysis that was performed by Combustion Engineering to reflect the use of a recent NRC-approved large break LOCA evaluation model and the numerical change of a few input parameters.
The staff has completed its review of the submittal.
As a result of this review, the staff concludes that the St. Lucie Plant, Unit 2 is in compliance with the criteria of 10 CFR 50.46 and Appendix K to 10 CFR Part 50, and that the large break LOCA reanalysis is acceptable.
Our safety evaluation is enclosed.
Sincerely,
Enclosure:
As stated cc w/enclosure:
See next page Original signed by
.. Edmond-B..Tour'igny, Pr'oject Manager Project Director ate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation DISTRIBUTION NRC 8 Local PDRs PD22 Reading SVarga GLainas DMilier ETourighy OGC-Beth EJordan JPartlow Gray File ACRS (10) l/Hodges D
11/ g PM:POgg~~
R B
D:
2 ETditr~c(ng:bd
<Wl1o MBerko 11//l/87 11/'f 87 11/ig /87 87ii200i47 87iii2 PDR ADOCK 05000389 P
n II
~
~ FI
gag REJIG~
Vp C
+
i 0
Cy nO t7 +>>*<<~
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 12, 1987 Docket No. 50-389 Nr. C. 0. Moody Group Vice President Nuclear Energy Florida Power and Light Company P.O.
Box 14000 Juno Beach, Florida 33408
Dear Nr. Moody:
SUBJECT:
LARGE BREAK LOCA REANALYSIS (TAC f66367)
In your letter dated August 25,
- 1987, you provided the results of the St.
Lucie Plant, Unit 2 large break LOCA reanalysis that was performed by Combustion Engineering to reflect the use of a recent NRC-approved large break LOCA evaluation model and the numerical change of a few input parameters.
The staff has completed its review of the submittal'.
As a result of this review, the staff concludes that the St. Lucie Plant, Unit 2 is in compliance with the criteria of 10 CFR 50.<6 and Appendix K to 10 CFR Part 50, and that the large break LOCA reanalysis is acceptable.
Our safety evaluation is enclosed.
S incere ly,
~i~~ ~~ 7.
Edmond G. Tourigny, Pro ecg anager Project Directorate II-2 0'ivision of Reactor Projects-I/II Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/enclosure:
See next page
Mr. C. 0.
Woody Florida Power Pi Light Company St. Lucie Plant CC:
Yir. Jack Shreve Office of the Public Counsel Room 4, Holland Building Tallahassee, Florida 32304 Resident Inspector c/o U.S.
NRC 7585 S.
Hwy AlA Jensen
- Beach, Florida 34957 State Planning 5 Development Clearinghouse Office of Planning 8 Budget Executive Office of the Governor:
The Capitol Building Tallahassee, Florida 32301 Harold F. Reis, Esq.
Newman K Holtzinger 1615 L Street, N.M.
Mashington, DC 20036 John T. Butler, Esq.
- Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Nr. Meldon B. Lewis, County Administrator St. Lucie County 2300 Virginia Avenue, Room 104 Fort Pierce, Florida 3345A Yir. Charles B. Brinkman, Yianager Washington - Nuclear Operations Combustion Engineering, Inc.
7910 Moodmont Avenue
- Bethesda, Yiaryland 20814 Jacob Daniel Nash Office of Radiation Control Department of Health arid Rehabilitative Services 1317 Minewood Blvd.
Tallahassee, Florida 32399-0700 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Executive Director for Operations 101 Marietta Street N.M., Suite 290C Atlanta, Georoia 30323