'IMqyt'2, 1986 Docket Nos.
50-335 and 50-389 Mr.
C. 0.
Woody Group Vice President Nuclear Energy Florida Power and Light Company P.
0.
Box 14000 Juno Beach, Florida 33408
Dear Mr. Woody:
SUBJECT:
GENERIC LETTER 83-28, Items 4.2. 1 AND 4.2.2, PREVENTATIVE MAINTENANCE PROGRAM FOR REACTOR TRIP BREAKER/MAINTENANCE AND TRENDING By letter dated March 10, 1986, the staff forwarded its safety evaluation on the above subject.
The staff's safety evaluation concluded that the responses were acceptable provided that the licensee confirms that the undervoltage trip (UVT) device roller rivet-armature clearance is measured with the UVT armature down in the energized position.
By letter dated April 14, 1986, you provided additional information.
The staff finds that the response contained in your April 14, 1986 letter to be acceptable, and items 4. 2. 1 and 4. 2. 2 can now be considered completely closed.
Sincerely, cc:
See next page Distribution
[Docket File
, NRC 8. Local PDR PD¹8 Reading PKreutzer ETourigny Gray File OELD ACRS (10)
E. Jordan B. Grimes J.
Partlow N. Thompson, DHFT E.
G. Tourigny, Project Manager PWR Project Directorate ¹8 Division of PWR Licensing-B "See previous concurrence page.
"DPLB: PD¹8 PKreutzer 5/
/86
~DPLB:PD¹8 ETourigny:jch 5/
/86 "DPLB: PD¹8 AThadani 5/
/86 seoS300040 saonm PDR ADOCK Ob000335 P
PDR L.
t ql E
t 1J, i I
I )
(
'i i
L
Docket Nos.
50-335 and 50-389 Mr.
C. 0.
Woody Group Vice President Nuclear Energy Florida Power and Light Company P.
0.
Box 14000 Juno Beach, Florida 33408
Dear Mr. Woody:
SUBJECT:
GENERIC LETTER 83-28, Items 4.2. 1 AND 4.2.2, PREVENTATIVE MAINTENANCE PROGRAM FOR REACTOR TRIP BREAKER/MAINTENANCE AND TRENDING By letter dated March 10, 1986, the staff forwarded its safety evaluation on the above subject.
The staff's saf'ety evaluation concluded that the responses were acceptable provided that the licensee confirms that the undervoltage trip (UVT) device roller rivet-armature clearance is measured with the UVT armature down in the -energized position.
By letter dated April 14, 1986, you provided additional information.
The staff finds that the response contained in your April 14, 1986 letter to be acceptable, and items 4.2. 1 and 4.2.2 can now considered to be completely closed.
Sincerely, cc:
See next page Distribution Docket File NRC 8 Local PDR PD¹8 Reading PKreutzer ETourigny Gray File OELD ACRS (10)
E. Jordan B. Grimes J.
Partlow N.
- Thompson, DHFT E.
G. Touri y, Project Manager PWR Project Directorate ¹8 Division of PWR Licensing-B DPLB: PD+,
DPLB:PD¹8~W PKreutEeP r
ETourigny:jch 5/~ /86 5/a486 DPLB:PD¹8 AThadani 5$~l86
Mo 1
Mr.
C. 0.
Woody Florida Power & Light Company St.
Lucie Plant CC:
Mr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Tallahassee, Florida 32304 Resident Inspector c/o U.S.
NRC 7585 S.
Hwy A1A Jensen Beach, Florida 33457 State Planning
& Development Clearinghouse Office of Planning
& Budget
. Executive Office of the Governor The Capitol Building Tallahassee, Florida 32301 Harold F. Reis, Esq.
Newman & Holtzinger 1615 L Street, N.W.
Washington, DC 20036 Norman A.,Coll, Esq.
McCarthy, Steel, Hector and Davis 14th Floor, First National Bank Building Miami, Florida 33131 Administrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Mr. Weldon B. Lewis, County Administrator St.
Lucie County 2300 Yirginia Avenue, Room 104 Fort Pierce, Florida 33450 Mr. Charles B. Brinkman, Manager Washington - Nuclear Operations Combustion Engineering, Inc.
7910 Woodmont Avenue
- Bethesda, Maryland 20814 Mr. Allan Schubert, Manager Public Health Physicist Department of Health and Rehabilitative Services 1323 Winewood Blvd.
Tal 1 ahassee, Florida 32301 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Executive Director for Operations 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323