ATTACHMENT3 ADMINISTRATIVEPROCEDURE NO. 0005725 REVISION 6 "DUTIES & RESPONSIBILITIES OF SHIFT TECHNICALADVISOR" 8510180096 85101'1 PDR ADQCK 05000335
'P PDR
I'
~
)T I
Page 1 of 18 FLORIDA POWER
& LIGHT COMPANY ST ~ LUCIE PLANT ADMINISTRATIVE PROCEDURE NO ~ 0005725 REVISION 6
1.0 TITLE
DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR 2 <<0 APPROVAL:
Reviewed by the Facility Review Group Approved. by J. H. Barrow (for)
Janua 20 1981 Plant Manager Janua 26 1981 Revision 6 Reviewed by F R G Approved by y A 'vo3
3.0 SCOPE
Plant Manager cX 19'9 K5 3.1
~por oee:
This procedure provides guidelines for the performance of the duties and responsibilities of the Shift Technical Advisor (STA) ~
3.2 Dis cus sion
.'UREG 0578 - "TMI Lessons Learned Task Force Status Report and Short-Term Recommendations" establishes the requirements for the STA position and for the performance of two functions:
l.
Accident Assessment Function The primary task of the STA is to provide an independent, dedicated concern for the safety of the St. Lucie Plant.
He is to provide advice to the Nuclear Plant Supervisor (NPS) during off-normal and emergency situations on actions to be taken to terminate or mitigate the consequences of such events'.
Operating Experience Assessment Function The STA, along with other St. Lucie Plant staff members and Nuclear Energy Department staff, will provide the Operating Experience Assessment Function required by the NRC in accordance with Administrative Procedure 0005724 'he STA's daily tasks and routine are also discussed in this plant procedure.
S OPS aaaaaaaaaaaaaaaaa F08
)IEIF9RMN,VNN OlB,'l This document is not controlled. Before use, verify information with e contro'lied doc ment.
DATE DOCT PROCEDURE DOCN AP0005725 SYS COMP COMPLETED ITM 6
Page 2 of 18 t
'ST ~ LUCIE PLANT ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR
3.0 SCOPE
(continued) 3.3
~duthotit 1 ~
NUREG 0578 2 ~
NUREG 0737 3.
Unit 1 and Unit 2 Technical Specifications
3.4 Definitions
1.
Shift Technical Advisor an individual with a bachelor's degree or equivalent in a scientific or engine'ering discipline who has been trained and qualified in accordance with Administrative Procedures 0005722 and 0005723 Plant Abnormal Occurrence Event - Events or conditions of a more significant nature which may include but are not limited to:
A.
Any event which meets the notification or reporting criteria of AP 0010721, "NRC Required Non-Routine Notifications and Reports".
/R6 B.
Any event or equipment failure of serious or immediate consequence even though not reportable under the criteria
- given by 3.4.2.A.
/R6 C.
Any procedure or operational error resulting from a fundamental misunderstanding of plant performance or safety requirements
~
D.
Entry into any action statement of Appendix A of the Technical Specifications other than for a planned surveillance or planned maintenance.
/R6 3 ~
Non Routine Event Events or condition of a less significant nature which may include but are not limited to:
A.
Equipment or component failures not included in 3.4.2.A.
/R6 BE Any recurrent component or equipment failures.
C.
Any departure from normal plant operating conditions.
D.
Entry into any action statement of the unit Tech. Specs. for any reason.
/R6 ED Any event or condition deemed of interest by the STA or NPS ~
Page 3 of 18 ST ~ LUCIE PLANT ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES PuVD RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR
4.0 PRECAUTIONS
4.1 The reportability requirements of 10 CFR 50'2 shall be met within the time frames noted in AP0010721, "NRC Required Non-Routine Notifications and Reports".
An effective and'timely review of,
"STA Abnormal Occurrence Report" is essential to meeting the appropriate on shift reporting requirements.
/R6 5+0 RESPONSIBILITIES:
5.1 The STA Group Lead Engineer has overall responsibility for staffing, implementing, coordinating, evaluating, and reviewing the STA program.
/R6 5.2 The Technical Staff Training Coordinator is responsible for developing, implementing, and documenting the STA Training Program in accordance with Administrative Procedures 0005722 and 0005723.
5.3 Each STA shall be responsible for,performing the accident assessment and operating experience assessment functions described in paragraphs 8.2 and 8.3 ~
5.4 The STA is responsible to the STA Group Lead Engineer.
During off-normal reactor plant conditions, the STA shall advise the Nuclear Plant Supervisor (NPS) in the Control Room or Technical Support Center (TSC).
5.5 The Technical Staff STA Group will be composed of personnel assigned
'o the STA Group Lead Engineer.
The STA Group Lead Engineer reports to the Technical Supervisor.
/R6 5.6 The STA position is required to be manned when either Unit is in Modes 1-4.
6+0
REFERENCES:
6.1 NUREG 0578, "TMI Lessons Learned Task Force Status Report and Short-Term Recommendations" 6.2 USNRC letter of September 13,
- 1979, "Follow-up Actions Resulting from the NRC Staff Reviews Regarding the Three Mile Island Unit 2 Accident" 6.3 6.4 USNRC Information Notice 80-06 and Supplement f71, "Notifications of Significant Events at Operating Power Reactor Facilities" FPL letter of December 27, 1979, revised March 7, 1980, from A. D. Schmidt to CD M. Wethy, "Duties and Responsibilities of Nuclear Plant Supervisors and Shift Technical Advisors"
/R6 6.5 NUEEG 0737
~
Page 4 of 18 ST ~ LUCIE PLANZ ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFC TECHNICAL ADVISOR 7eO RECORDS AND NOTIFICATIONS:
7.1 STA Turnover Check Sheet Attachment l.
7.2 Guidelines for Report of Plant Abnormal Occurrences.
7.3 Personnel error checklist " Attachment 3.
7.4 Notifications of incidents to NRC - Attachment 4 ~
/R6
Page 5 of 18 ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR 8+0 INSTRUCTIONS:
8.1 alifications and Trainin 1 ~
The STA shall have a bachelor's degree or equivalent in a scientific or engineering discipline.
2.
The STA shall be trained in'.
A.
The response and analysis of the plant for transients and accidents'E Details of the"design, function, arrangement, and operation of plant systems including the capabilities of instrumentation and controls in the Control Room.
3 ~
The STA initial qualification shall be certified in writing by the Technical Staff Training Coordinator and the Plant Manager.
/R6 8.2 Accident Assessment Function 1 ~
The primary task of the STA is to provide an independent dedicated concern for the safety of the St. Lucie Plant.
This is accomplished by providing diagnostic support to Operations personnel during off-normal events and by advising the NPS on actions to terminate or mitigate the consequences of such events.
2.
The role of the STA is to serve in an advisory capacity only and not to assume any command or control functions.
3 ~
"To accomplish this function, the STA should physically remain within an area which will allow him to be available to the Control Room, preferably immediately, but at the most within ten minutes.
4 ~
The STA should remain in the Control Room during the course of an accident in order to assess vital core parameters to ensure safety of the reactor.
He should not become involved with administrative and phone calling duties 5.
An off-shift STA will act as liason between the Control Room and TSC when the TSC is activated and manned.
6.
The STA is responsible for making the notifications (or ensuring the notifications are made) for the events as specified in AP0010721, "NRC Required Non-Routine Notifications and Reports"
~
/R6 The NRC Duty Officer will have a form similar to Attachment 4
from which he will ask questions.
It may be helpful, but is not
- required, to complete this attachment prior to making required notifications.
Page 6 of 18 ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR
8.0 INSTRUCTIONS
(cont inued) 8.2 (continued) 6.
(continued)
NOTE For some events, the NRC Duty Officer will request an open line of continuous communications be maintained to the, NRC Operations Center.
This communications channel shall be closed onl when authorized b
the NRC.
7 The STA may be relieved of his accident assessment responsibilities only by a qualified STA.
8.3 0 eratin Ex erience Assessment Function 1 ~
The plant operating experience assessment function is performed as a joint effort between members of the plant Technical Staff, the Nuclear Energy Staff and the STA.
2.
The following are guidelines for the STA in the performance of his responsibilities:
NOTE Except where noted, initialing to indicate review of each of the below documents is not re uired.
A.
Operator's Logs During each shift the STA should review and be cognizant of equipment out'of service, jumpers and disconnected leads, shift turnover sheets, surveillance/special testing in progress,'and the RCO log book entries for the preceding shift.
Periodically, the STA shall review and sign the contents of the Licensed Operator required reading books ~
B.
Licensee Event Reports (LER's), IE Bulletins, Circulars and
- Notices, and Pertinent NRC or Industrial Assessments of Operating Experience The STA will review the output of the Operational Experience Feedback Program (AP 0005724) and other information as directed by the STA Group Lead Engineer.
/R6 C.
Surveillance Testing - The STA should be aware of operations surveillance testing on his shift and of any unsatisfactory results.
D Radiological Conditions The STA should be cognizant (on a shift basis) of the radiological conditions existing in the plant including any gaseous or liquid releases in progress.
Page 7 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES hND RESPONSIBIa.ITIES OF THE SHIFT TECHNICS ADVISOk
8.0 INSTRUCTIONS
(continued) 8.3 (continued) 2.
(continued)
E.
General Plant Conditions The STA should be alert to and responsive toward any of the following:
Plant efficiency Maintenance items Housekeeping Procedures Quality Assurance Problems noticed in any of these areas should be brought to the attention of the appropriate department head.
F.
Reactor/Turbine Trips, Transients and Abnormal Occurrences 1.
The STA should immediately assess all reactor trips, transients and abnormal occurrences occurring on his shift with regard to safety.
This assessment should include, but not be limited to:
(a)
Sequence of events (b)
Causes (c)
Plant response (d)
Corrective action taken to ensure plant safety (e)
Violations of Technical Specifications and/or Safety Limits (f)
Procedural inadequacies/equipment out of service (g)
NRC required notification G.
Reports The STA shall commence preparing a report on all unusual or abnormal events occurring on his shift as soon as practical after termination of the event.
The STA report will fall into three categories:
1.
Non Routine Event Report-
/R6 These events, as defined in 3.4.3 are not significant, and do not require urgent attention.
These may be reported on the STA turnover sheet (Attachment 1) specified in 8.4.1 and will be reviewed in a routine manner.
Sufficient detail should be included in the report to inable a cognizant reviewer not specifically involved to make an independent determination of significance,
- urgency, and followup required.
Page 8 of 18 ST.
LUCIE PLANT ADHINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR
8.0 INSTRUCTIONS
(continued) 8.3 (continued) 2.
(continued)
G.
(continued) 2.
abnormal Occurrence Report.
These events, as defined in 3.4.2 are significant and require immediate or prompt attention and may require reports to NRC.
A report shall be drafted by the STA within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> utilizing the STA Abnormal Occurrence Report (Attachment 2).
/R6 3.
In House Event Report.
In House Event Reports are generated for significant plant events where a widely disseminated detailed report can provide useful operating experience feedback to
'lant personnel.
These events are identified by the STA Group Lead Engineer.
The format and distribution of the report will vary as appropriate to the event.
/R6 8.4 Shift Turnover and Relief 1.
The off-going STA should review applicable plant documents and conditions to determine any off-normal system conditions, non routine events, or trends and shall fillout a Turnover Checklist (Attachment 1).
Particular attention should be given to ensuring potential LER's/reportable items are listed on the Turnover Sheets.
2.
The off-going STA shall verbally pass on to the relieving STA the plant status, emphasizing system off"normal conditions and
- trends, tests in progress, etc.
3.
A tour of the plant should be conducted by the relieving STA as soon as practical after assuming the shift in order'to verify correct equipment operating parameters and status.
4.
Periodically (preferably once per week), all Shift Turnover Sheets shall be reviewed by the STA Grouop Lead Engineer and dispositioned i.n accordance with the Operating Experience Feedback Program AP 0005724.
/R6 5.
In the event of sickness, personal emergency, or other problem which precludes the STA from assuming or completing his scheduled shift, the STA Group Lead Engineer should be informed.
A relief should be arranged to fillthe STA position'ithin at least two (2)hours'R6
Page 9 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AD RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMEhT 1 DATE SHIFT UNIT 1 I.
SUMtfARY OF SHIFT EVENTS UNIT 2 I.
SUMMARY
OF SHIFT EVENTS II.
COMPONENTS/SYSTEMS UNDER TEST II.
COMPONENTS/SYSTEMS UNDER TEST III.
MAJOR EQUIPMENT PLACED OUT OF SERVICE THIS SHIFT III.
MAJOR EQUIPMENT PLACED OUT OF SERVICE THIS SHIFT IV.
ENTRY INTO AN ACTION STATEMENT IV.
ENTRY INTO AN ACTION STATEMENT V.
POTENTIAL LER'S (REQUIRES COMPLETION OF ATTACHMENT 2)
V.
POTENTIAL LER'S (REQUIRES COMPLETION OF ATTACHMENT 2)
VI.
PLANNED/SCHEDULED EVOLUTIONS VI.
PLANNED/SCHEDULED EVOLUTIONS VII.
ADDITIONAL INFORMATION VII.
ADDITIONAL INFORMATION OFF-GOING STA ON-COMING STA
~..
~
Page 11 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMENT 2 STA ABNORMAL OCCURRENCE REPORT (continued)
IV.
APPAREiNT CAUSE:
(Describe the principal cause of the event, along with any contributing factors
~ )
V.
CORRECTIVE ACTIONS:
(Describe any immediate corrective actions taken and any long term corrective actions recommended as a result of the event.)
VI ~
OThER CONSIDERATIONS:
Describe any other special considerations that apply to the event, such.
as the following:
unexpected or unexplained aspects of plant behavior.
inadequate performance of systems or components procedural deficiencies radiological releases or exposures personnel errors previous similar events
/R6
Page 12 of 18 t
ST ~ LUCIE PLANT ADMINISTRATIVE PROCEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPOiNSIBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMENT 2 STA ABNORMAL OCCURRENCE REPORT (continued)
VII'EPORTABILITY EVALUATION:
Check for reportability in AP //0010721, "NRC Required Vi on-Routine Notifications and Reports",
EPIP 83100021E "Duties and Responsibilities of the Emergency Coordinator",
and the applicable unit Tech. Specs.)
(check)
( This event is reportable under the following criteria:
(list specific paragraph)
For the following reason(s):
IS
')
OFF SITE PHONE NOTIFICATIONS UNUSUAL EVENT ALERT SITE AREA EMERGENCY GENERAL EMERGENCY 10 CFR 20.402/.403 10 CFR 50 ~ 72 10 CFR 73 ~ 71 TECH ~ SPEC ~ 6 ~ 7 ~ 1
'* Courtesy call to Mr. Jack Crlen5ak (NRC)
B)
WRITTEN REPORTS LICENSEE EVENT REPORT SPECIAL REPORT SAFETY LIMIT VIOLATION REPORT 10 CFR 21 REPORT RADIOLOGICAL EVENZ REPORT SECURITY EVENT REPORT NOTIFICATION TIME 911 STATE NRC
- after required notifications.
DUE DATE
/R6
Page 13 of 18 t
ST ~ LUCIE PLANT ADMINISTRATIVE PR CEDURE NO ~ 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMENT 2 STA ABNORMAL OCCURRENCE REPORT (continued)
VII.
(continued)
(check)
A review of the above documents indicates that this event is not reportable.
For difficult rule interpretations; the event was specifically evaluated against the following criteria:
and was determined not to be reportable for the following reasons:
VIII~
PERSONNEL ON SHIFT:
(List names of key personnel involved with event who may be able to'upplement the information in this report:
IX~
SUP PORTING DATA Attach a copy of all applicable log entries, computer printouts, recorder charts, etc.
A)
The minimum documentation for a rector trip transient is: (check)
Sequence-of-Events Printout.
Reactor Power Pressurizer Pressure Pressurizer Level Post Trip Review OP/3 0030119 Tave Tref H
T C
T S/G Levels
/R6
Page a4 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AND RESPOhSIBI'TIES OF
'1HE SHIFT TECHNICAL ADVISOR ATTACHMENT 2 STA ABNORMAL OCCURRENCE REPORT (continued)
IX.
SUPPORTING DATA:
(continued)
B)
For plant transients which do not result in a reactor trip obtain the recorder data in IX.A and additional data as appropriate:
Megawatts Feed/Steam Flow S/G Press Others:
C)
For non plant transient events consider such documents as RCO Logs, PWO's, lxP Surveys, Chemistry Logs, EPIP Checklists, etc.
List Attachments:
X.
D)
For events reportable under 10 CFR 50.73 which involve a personnel error send an Attachment f/3 "Personnel Error Checklist" to the applicable department head(s) for review, comment and approval.
The STA should provide draft comments on this attachment.
Attachment 83 sent a~ot Applicable This event has been entered into the in house event data base for tracking:
li.E 8 Prepared by:
Shift Technical Advisor Date Copies:
STA Logbook (w/o strip charts)
STA Group Lead Engineer (w/o strip charts)
Technical Staff Supervisor (w/o strip charts)
IHE File
/R6
Page 15 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT 'TECHNICAL ADVISOR
,ATTACHMENT 3 PERSONNEL ERROR CHECKLIST TO:
FROM:
Department Head Shift Technical Advisor DATE The information requested by this checklist is required for all Licensee Event Reports involving a personnel error by 10 CFR 50.73.
The occurrence described below is being evaluated as a potential LER.
Please fillout this checklist to provide the Shift Technical Advisor all the information necessary for the report.
The STA should provide draft comments for the Department Head review, comment and approval.
EVENT:
UNIT:
DATE:
TIME:
/R6
Page 1 6 of 18 ST. LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005 72 5, REVISION 6 DUTIES AND RESPO NS IBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMEL>T 3 PERSONNEL ERROR CHECKLIST (continued)
What was the type of personnel involved (i.e.; contractor, utility-licensed operator, utility non-licensed
- operator, other utility personnel)?
2.
~ Was the error a cognitive error (i.e.; failure to recognize the actual plant condition, failure to realize which systems should be functioning, failure to recognize the true nature of the event) or a procedural error?
3.
Was the error contrary to an approved procedure:
4.
Was the error the direct result of an error in an approved procedure?
5 ~
Was the error associated with an activity or task that was not covered by an approved procedure?
6.
Were there any unusual characteristics of the work location (i.e ~; heat, noise) that directly contributed to the error?
7 ~
What was the cause of this personnel error?
/R6
Page 17 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DUTIES AND RESPONSIBILITIES OF THE SHIFT TECHNICAL ADVISOR ATTACHMENT 3 PERSONNEL ERROR CHECKLIST (continued) 8.
tRat corrective actions have you taken to prevent this type of error in the future?
9.
Do you plan any further corrective actions in your department to prevent this type of error in the future?
List anticipated completion dates'0.
Do you recommend any further corrective actions from other departments (operator 'training, procedure clarifications, etc)2 Department Head:
Date:
(Please forward to STA Group when complete)
Page 18 of 18 ST.
LUCIE PLANT ADMINISTRATIVE PROCEDURE NO. 0005725, REVISION 6 DI.TIES AND RESPONSIBILITIES OF 'iHE SHIFT TECHNICAL 'r'd)VISOR Date ATTACHMENT 4 SIGNIFICANT EVENT REPORT (for NRC Notification)
Time Facility Name Florida Power
& Li ht St. Lucie Unit Caller Name 1.
Description of Event (a plicable Unit)
,Classification of Event Reactor Systems Status Pressure Flow (Pumps on)
PZR or RX Level Temperature ECCS Operating/Operable Cooling Mode Power Level Any Radioactive Relase or Increase Release?
Path Monitored?
Stopped Release Rate Steam Plant Status:
~/G Levels Equip. Failures Feedwater Source/Flow Electrical Dist. Status:
Normal Off-Site Power Sources Available?
Major Busses/Loads Lost Safeguards Busses Power Source'/G Running?
Personnel Casualties/Contamination?
2.
Consequences of Event:
Loaded?
Actual and Potential Safety Hazards:
Tech.
Spec. Violations?
State Notified?
3.
Cause of Event:
Press Release Planned?
Corrective Actions taken:
Planned:
4.
bRC contact name:
/R6