Attachment 1: Method of Evaluation Guidance Extract - Clean Copy (7/05/2017, E-Mail from K. Cummings/Nei to R. Wharton/Nmss/Dsfm 72.48 and Method of Evaluation)
ML17214A699
Person / Time
Site: Nuclear Energy Institute
Issue date: 07/05/2017
From: Cummings K
Nuclear Energy Institute
To: Wharton L
NRC/NMSS/DSFM/IOB
Wharton L
Shared Package
ML17214A697 List:
References
NEI 12-04
Download: ML17214A699 (21)


Text

DEFINITIONS 3.8 D EPARTURE FROM A METHOD OF E VALUATION D ESCRIBED IN THE FSAR (AS UPDATED) USED IN ESTABLISHING THE D ESIGN B ASES OR IN THE SAFETY ANALYSES Definition (§72.48(a)(2)):

Departure from a method of evaluation described in the FSAR (as updated) used in establishing the design bases or in the safety analyses means (i) changing any of the elements of the method described in the FSAR (as updated) unless the results of the analysis are conservative or essentially the same; or (ii) changing from a method described in the FSAR to another method unless that method has been approved by NRC for the intended application.

Discussion:

The I 0 CFR 72.48 definition of "departure... " provides licensees and CoC holders with the flexibility to make changes in methods of evaluation that are "conservative" or that are not important w ith respect to demonstrating that SSCs can perform their intended design functions. See also the definiti on and discussion of "method of evaluation" in Definition 3. 17. Guidance for evaluating changes in methods of evaluation under criterion I 0 CFR 72.48(c)(2)(viii) is provided in Section 6.8.

Conservative vs. Non-Conservative Evaluation Results Gaining margin by revising an element of a method of evaluation is considered to be a non-conservative change and thus a departure from a method of evaluation for purposes of I 0 CFR 72.48. Such departures require prior NRC approval of the revised method. Tn other words, analytical results obtained by changing any element of a method are "conservative" relative to the previous results, if they are closer to design bases limits or safety analyses limits (e.g., applicable acceptance guidelines).

For example, a change in an element of a method of evaluation that changes the result of a cask peak pressure analysis from 45 psig to 48 psig (with design basis limit of 50 psig) would be considered a conservative change for purposes of 10 CFR 72.48(c)(2)(viii).

This is because results closer to limiting values are considered conservative in the sense that the new analysis result prov ides less margin to applicable limits for making future physical or procedure changes without a license or CoC amendment.

Tf use of a modified element of a method of evaluation resulted in a change in calculated cask peak pressure from 45 psig to 40 psig, this would be non-conservative. This is because the change would result in more margin being available (to the design basis limit of 50 psig) for a licensee or CoC holder to make future changes to the cask design or procedures that once again reduce the margin.

"Essentially the Same" Licensees and CoC holders may change one or more elements of a method of evaluation such that results move in the conservative or non-conservative di rection w ithout prior NRC approval, provided the results are "essentially the same" as the previous results from the MOE without the modified element(s). Results are "essentially the same" if they are w ithin the margin of error for the type of analysis being performed. Variation in results due to routine analysis sensitivities or calculational differences (e.g., rounding errors and use of different computational platforms) would typically be within the analysis marg in of error and thus considered "essentially the same."

"Approved by the NRC for the Intended Application" Rather than make a minor change to an existing method of evaluation, a licensee or CoC holder may also adopt a completely new methodology without prior NRC approval provided the new method is approved by the NRC for the intended application. A new method is "approved by the NRC for the intended application" if it is approved for the type of analysis being conducted and the licensee or CoC holder satisfies applicable terms and conditions for its use. More detailed guidance for making this determination is prov ided in Section 6.8.2.

3.15 INPUT P ARAMETERS Definition:

Input parameters are those values derived directly from the physical characteristics of SSCs or processes in the ISFSI facil ity or cask design, including flow rates, temperatures, pressures, dimensions or measurements (e.g., volume, weight, size, etc.), and system response times.

Discussion:

The principal intent of this definition is to distinguish methods of evaluation from input parameters. Changes to methods of evaluation described in the UFSAR (see Definition 3.17) are evaluated under criterion I 0 CFR 72.48( c )(2)(vi ii), whereas changes to input parameters described in the UFSAR are considered changes to the ISFST facility or cask design that would be evaluated under the other seven criteria of I 0 CFR 72.48( c)(2), but not criterion ( c )(2)(vi ii).

There are two cases in which an input parameter is treated as an element within a method of evaluation. For guidance regarding these two cases, refer to Definition 3. 17.

Examples illustrating the treatment of input parameters are provided in Appendix A.

Appendix A also provides examples to describe the specific elements of evaluation methodology that would require evaluation under I 0 CFR 72.48(c)(2)(vi ii) and to clearly distinguish these from specific types of input parameters that are controlled by the other seven criteria of l 0 CFR 72.48(c)(2).

3.17 METHOD OF EVALUATION Definition:

Method of evaluation means the calculational framework used for evaluating behavior or response of the I SF ST facility, cask design, or an SSC.

Discussion:

Examples of elements of methods of evaluation are presented below. Proposed activities involving modifications to such methods of evaluation require evaluation under I 0 CFR 72.48( c)(2)(viii) only for methods of evaluation used either in UFSAR safety analyses or in establishing the design bases, and only if the methods are described, outlined or summarized in the UFSAR. Proposed activities involving modifications to methods of evaluation that are subject to 10 CFR 72.48 include changes to elements of existing methods described in the UFSAR and to changes that involve replacement of existing methods of evaluation with alternative methodologies.

Elements of Methodology Example Data correlations

  • Tipover and end drop analysis based on industry-referenced reports Means of data reduction
  • ASME methods for evaluating cask parameters, e.g.,

elastic stress intensity Physical constants or coefficients

  • Heat transfer coefficients, boundary conditions, burnup peaking factors, and cross-section libraries
  • Friction coefficient in a tipover analysis Mathematical models
  • Methods of heat transfer assumed (i.e., conduction, convection, and radiation), mesh size, material performance - elastic or plastic Specific limitations of a
  • Benchmarking and correlation ranges computer program Specified factors to account for
  • Criticality calculation biases, fuel burnup, percent uncertainty in measurements or fuel burnup uncertainty data Statistical treatment of results
  • Vendor-specific analysis approach (e.g., material property testing of composite neutron poison, B-10 content validation from blackness testing, confidence and tolerance limits)

Dose conversion factors and

  • ICRP factors assumed source terms

Methods of evaluation described in the UFSAR subject to criterion 10 CFR 72.48(c)(2)(v ii i) are:

Methods of evaluation used in analyses that demonstrate that design basis limits of fission product barriers are met (i.e., for the parameters subject to criterion I 0 CFR 72.48( c )(2)(vi i)).

Methods of evaluation used in UFSAR safety analyses, including cask and accident analyses typically presented in the accident analyses section(s) of the UFSAR, to demonstrate that consequences of accidents do not exceed 10 CFR 72.1 06 dose limits.

Methods of evaluation used in supporting UFSAR analyses that demonstrate intended design functions w ill be accomplished under design basis conditions that the ISFSI fac ility and cask design are required to withstand, including natural phenomena, environmental conditions, and dynamic effects.

Methods of evaluation used in UFSAR analyses that demonstrate that radioactive doses from normal operations and anticipated occurrences w ill be w ithin the limits of 10 CFR 72. 104.

Methods of evaluation subject to criterion I 0 CFR 72.48( c)(2)(viii) do not include methods used to select fuel for loading into the cask (i.e., decay heat and burnup determinations, and determination of damaged fuel versus undamaged or intact fuel, etc.) unless those methods are described in the UFSAR.

If a methodology permits the licensee or cask certificate holder to establish the value of an input parameter on the basis ofI SFSI facility-or cask design-specific considerations, then that value is an input to the methodology, not part of the methodology. On the other hand, an input parameter is considered to be an element of the methodology if:

The method of evaluation includes a description of how to select the value of an input parameter to yield adequately conservative results. However, if a I icensee or cask certificate holder opts to use a value more conservative than that required by the selection method, reduction in that conservatism should be evaluated as an input parameter change, not a change in methodology.

The development or approval of a methodology was predicated on the degree of conservatism in a particular input parameter or set of input parameters. In other words, if certain elements of a methodology or model were accepted on the basis of the conservatism of a selected input value, then that input value is considered an element of the methodology.

5. 72.48 SCREENING Once it has been determined that I 0 CFR 72.48 is applicable to a proposed activity via the AD process, a screening is performed to determine if the activity should be reviewed against the evaluation criteria of IO CFR 72.48(c)(2).

Engineering, design and other technical information concerning the activity and affected SSCs should be used to perform the I 0 CFR 72.48 screening. The I 0 CFR 72.48 screening is performed to determine whether the activity or part(s) thereof need to be evaluated in accordance with 10 CFR 72.48(c)(2) and Section 6 of this guidance. Refer to Section 1.3 for discussion of the use of the word "change" in the context of I 0 CFR 72.48. A full I 0 CFR 72.48 evaluation is required for a proposed activity or part(s) thereof that involve any one of the fo llowing:

A change to a UFSAR-described design function of an SSC or cask design, A change to a UFSAR-described method of performing or controlling a design

function, A change to a UFSAR-described method of evaluation or use of an alternative method of evaluation for demonstrating that intended design functions will be accomplished, or A test or experiment not described in the UFSAR where an SSC is utilized or control led in a manner that is outside the reference bounds of the design for that SSC or is inconsistent with analyses or descriptions in the UFSAR.

5.1.5.1 Determining if an Activity Involves an MOE The fo llowing step-by-step guidance may be used to determine if a proposed activity involves an MOE:

The discussion that follows is organized into four distinct steps:

Step 1 - Distinguish between input parameters and MOEs Step 2 - Determine if an MOE is "... described, outlined or summarized in the UFSAR."

Step 3 - Determine ifthe MOE is used for one of the three cited purposes Step 4 - Identification of intended design functions under design basis conditions Each of these steps is discussed in detail below.

Step 1 - Distinguish Between Input Parameters and Methods of Evaluation This step involves application of two separate definitions. They are:

Definition 3. 15 - "Input Parameters" Definition 3. 17 - "Method of Evaluation"

The core definitions for each, along with explanatory paragraphs are provided below, with emphasis added:

Input Parameters:

Input parameters are those values derived directly from the physical characteristics of SSCs or processes in the ISFSI facility or cask design, includingflow rates, temperatures, pressures, dimensions or measurements (e.g., volume, weight, size, etc.), and system response times.

The principal intent of this definition is to distinguish methods of evaluation from evaluation input parameters. Changes to methods of evaluation described in the UFSAR are evaluated under criterion I 0 CFR 72.48(c)(2)(viii), whereas changes to input parameters described in the UFSAR are considered changes to the ISFSifacility or cask design that would be evaluated under the other seven criteria of JO CFR 72.48(c)(2),

but not criterion (c)(2)(viii).

Method of Evaluation:

Method of evaluation means the calculational framework used for evaluating behavior or response of the ISFSI facility, cask or an SSC

... an input parameter is considered to be an element of the methodology if:

The method of evaluation includes a methodology describing how to select the value of an input parameter to yield adequately conservative results. However, if a licensee opts to use a value more conservative than that required by the selection method, reduction in that conservatism should be evaluated as an input parameter change, not a change in methodology.

The development or approval of a methodology was predicated on the degree of conservatism in a particular input parameter or set of input parameters. In other words, if certain elements of a methodology or model were accepted on the basis of the conservatism of a selected input value, then that input value is considered an element of the methodology.

There are examples and an extended discussion provided for each of the above elsewhere in this guidance. However, a few points/observations may be useful :

Input parameters are values. Those values are derived from physical characteristics of SSCs or a process.

MOEs are the "calculational framework." The examples in Definition 3. 17 illustrate that MO Es tend to involve some type of mathematical equations or are related to physical constants of nature.

In many cases, a simple inspection of whether the topic of consideration is a value, a constant of nature, or some form of a mathematical expression would be insightful.

The two definitions, 3.1 5 and 3. 17, must be read in their entirety. The stated purpose is to distinguish input parameters from MOEs. This is because the treatment under I 0 CFR 72.48 is entirely different for input parameters and MO Es. The screening criteria are different and, as noted above, the I 0 CFR 72.48 criteria to be answered are mutually exclusive.

Criteria I through 7 are answered for input parameters but not for MOEs.

Criterion 8 is solely for MOEs that require such a review, including the two cases described above in wh ich an input parameter is considered to be an element of the MOE. The remaining three steps described next will determine if a given modification to an MOE requires a I 0 CFR 72.48 review.

Note that any calculational framework cou ld potentially satisfy the meaning of "Method of Evaluation" in Definition 3.17. This creates a possible source of confusion because it is common to use the term "MOE change" to mean that any modification to an MOE requires a I 0 CFR 72.48 evaluation. However, Steps 2 and 3 indicate that two more attributes are required to achieve that status as described in the "Discussion" section of Definition 3.17. They are:

The MOE is described in the UFSAR (Step 2)

The MOE is subject to I 0 CFR 72.48 criterion (c)(2)(viii) review (Step 3)

Step 2 - Determine if an MOE is "... described, outlined or summarized in the UFSAR" The paragraph entitled "Discussion" from Definition 3.17 is provided below, with emphasis added:

Examples of methods of evaluation are presented below. Proposed activities involving modifications to such methods of evaluation require evaluation under JO CFR72.48(c)(2)(viii) only for methods of evaluation used either in UFSAR safety analyses or in establishing the design bases, and only if the methods are described, outlined or summarized in the UFSAR. Proposed activities involving modifications to methods of evaluation that are subject to JO CFR 72.48 include changes to elements of existing methods described in the UFSAR and to changes that involve replacement of existing methods of evaluation with alternative methodologies.

Proposed modifications to such methods of evaluation require evaluation under I 0 CFR 72.48(c)(2)(viii): only for:

evaluations used either in UFSAR safety analyses or in establishing the design bases, and only if the methods are described, outlined or summarized in the UFSAR.

Step #2 simply identifies if the method is"... described, outlined or summarized in the UFSAR."

The intention here is if the MOE was discussed in any fashion, then the MOE is considered to be "described in the UFSAR."

Step 3 - Determine if the MOE is used for one of the three cited purposes The second required feature is that the MOE must be "... used either in UFSAR safety analyses or in establishing the design bases.... "

These purposes correspond to the language used in the defined term of I 0 CFR 72.48(a)(2), which is repeated here:

Departure from a method of evaluation described in the FSAR (as updated) used in establishing the design bases or in the safety analyses Definition 3.17 expands upon the meaning of these purposes. The following phrases explicitly describe these three purposes:

Methods of evaluation described in the UFSAR subject to criterion J 0 CFR 72.48(c)(2)(viii) are:

Methods of evaluation used in analyses that demonstrate that design basis limits of fission product barriers are met (i.e., for the parameters subject to criterion J 0 CFR 72.48(c)(2)(vii))

Methods of evaluation used in UFSAR safety analyses, including confinement and accident analyses, to demonstrate that consequences of normal operations, off-normal events, and accidents do not exceed JO CFR 72. J04 or JO CFR 72.J06 dose limits, as applicable Methods of evaluation used in supporting UFSAR analyses that demonstrate intended design functions will be accomplished under design basis conditions that the ISFSI or cask is required to withstand, including natural phenomena, environmental conditions, and dynamic effects.

The three purposes can be summarized as MOEs:

I. Results demonstrate that design basis limits of fi ssion product barriers are met

2. Used to calculate consequences (on-site and off-site accident dose)
3. That demonstrate intended design functions will be accomplished under design basis conditions Items 1 and 2 above should be self-evident to any I 0 CFR 72.48 evaluator involved in such activities. Item 3 includes two embedded terms, each with their own extended source of guidance. Identification of this usage is the subject of Step 4.

Step 4 - Identification oflntended Design Functions under Design Basis Conditions.

Design function is a critical concept that is used throughout this guidance (Definiti on 3. 10).

There are two points to be made here:

I. The definiti on for design function is rather lengthy and is heavily oriented around design bases functions and those functions that support or impact design bases functions.

2. The term design bases functions comes from NET 97-04, which is endorsed in Regulatory Guide 1.186.

This discussion will not expand further on the meaning of these two critical terms, design function and design bases functions, other than to note that a complete understanding of both is required to fully understand the identification ofMOEs subject to review under 10 CFR 72.48. The meanings of design function and design bases functions are included in Definition 3. 10.

5.1.5.2 Software Revisions Associated with an MOE This section discusses a revision to existing software that implements an MOE. A change to the software that implements an MOE does not necessarily cause a departure from an MOE, requiring prior NRC approval. Therefore, it is critical to understand the scope and type of changes that were made.

NOTE: This discussion does NOT address the replacement of, or implementation of new, MO Es or software.

Step 1 - Does the Software Need to be Considered?

The first step in determining the impact of the software revision is to determine if the software tits the definition of an MOE and is, therefore, within the scope of consideration. A discussion of the identification of applicable MOEs is included in Section 5.1.5. 1.

Step 2 - Performing the Screening Review lf the software does meet the criteria for an MOE, then the next step is to understand the scope and type of modification(s) involved. There are many elements to a software package. Determining exactly which elements are being revised is critical. Examples of elements of methodology are given in Definition 3.17. A simple statement regarding the "revision," "version" or "modification" identifier as the basis for a I 0 CFR 72.48 screening response is inadequate.

One CoC holder/I icensee may use several "versions" of a computer code revision to address errors and minor improvements, thereby saving a new revision for major modeling updates, while another vendor/licensee may change "revisions" of a computer code to address a number of minor errors without changing any analytical modeling. Use of a later version or release of a computer code that is already part of an MOE described in the UFSAR would be evaluated as a change to an element of a method of evaluation.

5.1.5.3 Additional Concerns A proposed activity involving an MOE is a change (i.e., screens in) if the modification is not in strict accordance with the constraints and limitations outlined in an NRC Safety Evaluation Report (SER), vendor/licensee topical report, or the UFSAR (hereafter referred to as "source documents"). A proposed activity to replace an MOE with an alternate MOE (i.e., different software package) always screens in.

The technical description of the MOE in the source documents defines any constraints and limitations on use of the MOE. For example, if a source document for a lattice physics analytical model describes its application to a particular fuel design (e.g., Westinghouse I 5x 15), the specific reference to the Westinghouse I 5x 15 fuel design shall be viewed as a constraint or limitation on the use of the analytical model unless the source document states that the analytical model may be used for other fuel designs.

For a proposed modification to an element of an MOE, it is essential to identify and understand the details of the modification. For each modification, the pertinent constraints and limitations associated with the MOE, if any, need.to be identified.

Modifications to more than one element may need to consider the cumulative impact of all the modifications on the constraints and limitations. ln these cases, the modifications to the MOE may be a "replacement MOE" rather than a "modification to an element of an MOE."

The I 0 CFR 72.48 screening should identify if a proposed modification to one or more elements of an MOE that is not consistent with the constraints and limitations affects an element of the MOE or effectively causes the MOE to

become an alternative MOE. This distinction is necessary to correctly apply the Evaluation guidance in Section 6.8.

Modifications to an element of an MOE that are administrative, such as changing input/output descriptive labels, changing output table titles, adding/deleting intermediate output results, re-sequencing output tables, adding non-executable comments in the computer coding, etc., would not be considered changes and would not require a I 0 CFR 72.48 evaluation. Note that although these types of modifications to an MOE might be considered editorial or administrative and not require a 72.48 screening (per Subsection 4.3 of this guidance), it is recommended that a I 0 CFR 72.48 screening be performed to provide the explanation that the changes are indeed editorial or administrative and have no impact on the MOE.

Modifications to MOEs that are within the constraints and limitations require case-specific consideration to determine if the modification is a change to an element of an MOE or a different MOE. Typical constraints and limitations may include the following:

Breathing rate of3.47 E-4 m3/sec from an NRC regulatory guide for inhalation dose calculations Use of dose conversion factors from an ICRP standard Fractional release values for confinement analysis from NUREG-1536 Heat transfer correlations Analysis performed "consistent with" a cited topical report.

Neutron absorber blackness is "appropriately modeled."

A subroutine iterates to a specified convergence limit A boundary condition is set to a specified value.

Cross sections were obtained by collapsing the library from "x" groups to "y" groups.

If the pertinent constraints and limitations for an MOE are not known or cannot be identified, then the modification to the element of the MOE is considered to be adverse and screens in.

If a source document identifies that a particular feature is included in an MOE, but does not describe how the feature is modeled, a modification to the specific modeling of the feature is not adverse because the modification is consistent with the terms (and level of detail) of the approved MOE. A full I 0 CFR 72.48 evaluation would not be required. However, if a source document states that a particular feature is modeled, a modification to eliminate that feature would not

be consistent with the description in the source document and would be adverse, requiring a full I 0 CFR 72.48 evaluation.

See Section 6.8 for guidance on completing the I 0 CFR 72.48 evaluation to determine if a departure from a method of evaluation is involved.

6.8 DOES THE ACTIVITY RESULT IN A DEPARTURE FROM A METHOD OF EVALUATION USED lN ESTABLISHING THE DESIGN BASES OR lN THE SAFETY ANALYSES?

The TSFST or cask UFSAR contains design and licensing basis information for an TSFSJ facility or spent fuel storage cask design, including descriptions of how regulatory requirements for design are met (such as the requirements governing normal operations and off-normal events), and the adequacy of structures, systems, and components provided for the prevention of accidents and the mitigation of the consequences of accidents. Analytical methods are a fundamental part of demonstrating how the design meets regulatory requirements and why the TSFSI facility 's or cask's response to accidents and events is acceptable. As such, in cases where the analytical methodology was considered to be an important part of the conclusion that the ISFSI facility or cask met the required design bases, these analytical methods were described in the UFSAR and received varying levels ofNRC review and approval during licensing.

Because I 0 CFR 72.48 provides a process for determining if prior NRC approval is required before making changes to the ISFSI facility or spent fuel storage cask design as described in the UFSAR, changes to the methods of evaluation (MOEs) described in the UFSAR also fall under the provisions of the I 0 CFR 72.48 process, specifically criterion (c)(2)(viii). In general, licensees or cask certificate holders can make changes to MOEs without first obtaining a license amendment or cask CoC amendment in one of two ways:

I.

Changing one or more elements of the MOE, provided the results are essentially the same as, or more conservative than, previous results.

2.

Using a new or different MOE, if the MOE has been approved by the NRC for the intended application.

The responsibility and authority for performing the I 0 CFR 72.48 review for a cask design approved under a CoC can be either the general licensee or the CoC holder. 10 CFR 72.48 responsibility and authority for a specific license are solely the specific licensee's. Tn both cases, however, it is typically the cask design authority that utilizes MOEs to perform the safety analyses or establish the cask design basis and would have the need to modify an element of an MOE or use a new or different MOE. As such, the licensee and cask design authority must coordinate efforts closely to ensure roles and responsibilities are clearly delineated and information is shared appropriately to ensure a complete and comprehensive I 0 CFR 72.48 review is performed for any change to an MOE.

If the 10 CFR 72.48 screening for the proposed activity concludes that a change to an MOE is not involved, then the I 0 CFR 72.48 screening should reflect that I 0 CFR 72.48(c)(2)(viii) is not applicable. Tfthe 10 CFR 72.48 screening determines that the

proposed activity involves only a change to an MOE, then the I 0 CFR 72.48 evaluation should reflect that criteria 10 CFR 72.48(c)(2)(i-vii) are not applicable.

If a proposed activity (e.g., a physical modification or procedure change) also involves a modified MOE element or a new or different MOE to analyze that physical modification or procedure change, the MOE change should be evaluated first, against 10 CFR 72.48(c)(2)(viii), before the physical modification or procedure change is evaluated against 10 CFR 72.48(c)(2)(i) through (vii). This is recommended because ifthe MOE change requires NRC approval, the licensee or CoC holder may wish to reconsider the physical modification or procedure change. If the MOE change is determined not to require NRC approval, these two separate evaluations may be documented in the same, or separate overall I 0 CFR 72.48 reviews, at the discretion of the licensee or CoC holder.

The first step in applying this criterion is to identify the MOEs that are affected by the change. This is accomplished during application of the screening criteria as described in Section 5.1.5.

Next, the licensee or cask CoC holder must determine whether the change constitutes a departure from a method of evaluation that would require prior NRC approval. As discussed further below, for purposes of evaluations under this criterion, the following changes are considered a departure from a method of evaluation described, outlined, or summarized in the UFSAR and used in the safety analysis or establish design bases:

Changes to any element of an MOE that yield resu Its that are not conservative or not essentially the same as the results from the analyses of record.

Use of a new or different MOE that is not approved by NRC for the intended application.

By way of contrast, the following changes are not considered departures from a method of evaluation:

Departures from methods of evaluation that are not described, outlined or summarized in the UFSAR (such changes will have been screened out as discussed in Section 5.1.5);

Use of a new NRC-approved methodology (e.g., new or upgraded computer code) to reduce uncertainty, provide more precise results, or other reason, provided such use is (a) based on sound engineering practice, (b) technically appropriate for the intended application, and (c) within the limitations of the applicable SER. The basis for this determination should be documented in the licensee or cask CoC holder evaluation.

See Subsection 6.8.2 for additional guidance on interpreting whether an MOE is approved for the intended application.

Use of a methodology revision that is documented as providing results that are essentially the same as or more conservative than either the previous revision of the

same methodology or with another methodology previously accepted by NRC through issuance of an SER.

Use of a methodology that is described in the UFSAR, but has not been specifically approved by the NRC either through a Topical Report review or through endorsement in the storage system or I SF SI SER to evaluate the impact of a modification to the ISFSI faci lity, cask design, or procedures. For example, the UFSAR describes the methodology, inputs, assumptions, and results of the heat transfer evaluations of the storage system. The methodology was never submitted to the NRC for approval in a Topical Report, and the storage system SER does not indicate whether the NRC has endorsed or approved the methodology. In this case, use of the methodology described in the UFSAR to evaluate the impact of a modification to the ISFSI faci lity, cask design or procedure would be acceptable and appropriate.

Subsection 6.8.1 provides guidance for making changes to one or more elements of an existing MOE. Subsection 6.8.2 provides gu idance for adopting an entirely new MOE to replace an existing one.

It should be noted that the NRC staff, in reviewing dry cask storage designs, does not generically approve methodologies described or referenced in UFSARs. "Generic" approval as used here, means approval for use by any licensee or CoC holder. Instead, the NRC states in its SERs, following the guidance in the Standard Review Plan, that the design has been found to be acceptable in each review discipline area for the particular licensing action reviewed and approved (i.e., initial ISFSI license, cask CoC, or amendment thereto). See Subsection 6.8.2. 1 for additional guidance on NRC approval of methods.

If, however, CoC holders or licensees choose to submit detailed methodologies to the NRC for generic review and approval as part of applications for design approval or as separate topical reports, the staff may document NRC endorsement or approval in appropriate SERs on a broader basis. Such endorsements or approval wi ll faci litate CoC holders and licensees to use the I 0 CFR 72.48 process that deals with approved methodologies.

6.8.1 Guidance for Changing One or More Elements of a Method of Evaluation The definition of "departure... " provides licensees and CoC holders with the flexibility to make changes under I 0 CFR 72.48 to elements of MO Es whose results are "conservative" or that are not important with respect to the demonstrations of performance that the analyses provide. Changes to elements of MO Es that yield conservative results or results that are essentially the same over the entire range of use for the method would not be departures from approved MOEs.

The guidance is summarized in the following table.

Mar in Results Prior NRC A roval Lost Conservative No

Gained Non-Conservative Yes

- Same Essentially The Same No One common use of this part of the MOE evaluation is the adoption of a later version of a computer code previously used as an MOE as described in the TSFST or cask FSAR. In such cases, the MOE user must first verify and validate the updated computer code as acceptable for use and code users are qualified as required by the governing Quality Assurance program. Then, the MOE user must use the updated computer code to analyze one or more benchmark cases that had been analyzed using the previous version of the computer code. The results of old and new sets of benchmark cases are then compared to determine if the updated computer code produces resu lts that are conservative, non-conservative, or essentially the same for the same benchmark case(s).

To determine if the new results are conservative, non-conservative or essentially the same, the guidance in Sections 6.8. 1.1 and 6.8.1.2 is appl ied.

6.8.1.1 Conservative versus Non-Conservative Results Gaining margin by changing one or more elements of an MOE is considered to be a non-conservative change and thus a departure from an MOE for purposes of I 0 CFR 72.48.

Such departures require prior NRC approval of the revised MOE. Analytical results obtained by changing any element of an MOE are "conservative" relative to the previous results, if they are closer to design bases limits or safety analyses limits (e.g., applicable acceptance guidelines). For example, a change from 45 psig to 48 psig in the result of a cask peak pressure analysis (with design basis limit of 50 psig) using a revised MOE would be considered a conservative change when applying this criterion. Jn other words, the revised MOE is more conservative if it predicts more severe conditions given the same set of inputs. This is because results closer to limiting values are considered conservative in the sense that the new analysis result provides less margin to applicable limits for making potential physical or procedure changes without a license/Coe amendment.

In contrast, if the use of a modified MOE resulted in a change in calculated cask peak pressure from 45 psig to 40 psig, this wou ld be a non-conservative change. That is because the change would result in more margin being available (to the design basis limit of 50 psig) for the licensee to make more significant changes to the physical ISFSI facility, cask design, or procedures.

6.8.1.2 "Essentially the Same" Results Licensees or cask CoC holders may change one or more elements of an MOE such that results move slightly in the non-conservative direction without prior NRC approval, provided the revised result is "essentially the same" as the previous result. Results are "essentially the same" if they are with in the margin of error for the type of analysis being performed. Variation in results due to routine analysis sensitivities or calculational differences (e.g., rounding errors and use of different computational platforms) wou ld typically be within the analysis margin of error and thus considered "essentially the

same." For example, when an MOE is applied using a different computational platform (mainframe vs. workstation), results of cases run on the two platforms differed by less than I%, which is the margin of error for this type of calculation. Thus the results are essentially the same, and do not constitute a departure from an MOE that requires prior NRC approval.

The determination of whether a new analysis result would be considered "essentially the same" as the previous result can be made through benchmarking the revised MOE to the existing one, or may be apparent from the nature of the differences between the MO Es.

When benchmarking a revised MOE to determine how it compares to the previous one, the analyses that are done must be for the same set of conditions to ensure that the results are comparable, and the revised MOE should only be used where the benchmarking has demonstrated it to be conservative or essentially the same. Comparison of analysis MO Es should consider both the peak values and time behavior of results, and engineering judgment should be applied in determining whether two MOEs y ield results that are essentially the same.

6.8.2 Guidance for Changing from One Method of Evaluation to Another 6.8.2.1 NRC Approval of Methods The definition of "departure... " provides licensees and CoC holders with the flexibility to make changes under I 0 CFR 72.48 from one MOE to another provided that the new MOE is approved by the NRC for the intended application. A new MOE is approved by the NRC for intended application if it is approved for the type of analysis (Defi nition 3.22) being conducted, and the applicable terms, conditions and limitations for its use as defined in the Safety Evaluation Report and FSAR are satisfied.

Methodologies published by the NRC in NUREGs or NUREG-CRs are not necessarily "approved by the NRC for the intended application" because they may lack suitable ISFSI-or cask-specific context. In order to be considered "approved by the NRC for the intended application," such methods must be approved in an SER or otherwise accepted by the NRC as part of the TSFST facility's or cask's licensing basis. 1 NRC approval of an MOE would typically fo llow one of two paths. Some licensees and CoC holders may prepare and obtain NRC approval of topical reports that describe MO Es for the performance of a given type or class of analysis (Definitions 3.22 and 3.7). Through a SER, the NRC would approve the use of the MO Es for a given class of ISFSis or spent fuel storage casks. In some cases, the NRC would accord generic approval of analysis MO Es. Terms, conditions and limitations relating to the application of the MO Es would usually be documented in the topical reports, the SER, and correspondence between the NRC and the MOE owner that is referenced in the SER or associated correspondence.

1 This, and the following discussion is taken from NEl's Q&A with NRC staff on I 0 CFR 50.59, Update 4, dated April 200 I (Reference 3). Specifically, Questions E. 16, E. 19, E.22, E.23, and G.5.

The second path is the acceptance of a specific analysis as part of a I icensing action rather than generic approval of an MOE. In these cases, the NRC's acceptance would typically be part of an TSFSJ or cask design 's licensing basis and limited to a given TSFST or spent fuel storage cask design and a given application. Again, a thorough understanding of the terms, conditions and limitations relating to the application of the MOE is essential. This information should be documented in the original license or CoC application or license or CoC amendment request, the SER, and any correspondence between the NRC and the MOE owner that is referenced in the SER or associated correspondence.

Regardless of the level ofNRC review/approval for a given analysis methodology, methods described in the JSFST UFSAR or the generic cask UFSAR (i.e., the current licensing basis) are considered approved by the NRC for the intended application (Reference 3, Questions E.22 and E.23), but not generically approved for use by all TSFSI licensees or CoC holders.

6.8.2.2 Statements of Consideration The Statements of Consideration (SOC) for the 1999 rulemaking involving I 0 CFR 50.59 and 10 CFR 72.48 were considered in developing this guidance. While the SOC are not considered part of the 10 CFR 50.59 or 72.48 regulations, both NET 96-07, Revision I and NET 12-04 are largely consistent with them. Based on extensive public discussions and comment resolution between the industry and NRC staff, two aspects of the SOC were clarified in NET 96-07, Revision I and endorsed by the NRC in RG

1. I 87. NET l 2-04's predecessor document, NET 96-07, Appendix B included these same clarifications, which were endorsed in RG 3.72 and are further enhanced here (Reference 3, Question G.5):

First, I 0 CFR 54.21 (d) requires that the UFSAR be supplemented for license renewal with summary descriptions of time-limited aging analyses (TLAAs) and aging management programs (AMPs). The SOC state that changes to this license renewal information requires "evaluation" under 10 CFR 50.59(c)(viii). The intent of the SOC discussion was to include TLAA and (as applicable) AMPs within the scope of "design bases and safety analyses" for purposes of I 0 CFR 50.59 criterion 8 so that if associated evaluation methods were described in the UFSAR they would fall within the definition of "methods of evaluation" and thus, the scope of 10 CFR 50.59. The industry guidance reflects that all changes subject to 10 CFR 50.59 may first be screened to determine if evaluation against the eight criteria of I 0 CFR 50.59 is required. Thus, contrary to the SOC, changes to TLAAs and AMPs for license renewal that screen out based on the definitions and guidance in NET 96-07, Revision 1, do not require evaluation under I 0 CFR 50.59. The guidance in NET 12-04 adopts a similar clarification to the SOC for I 0 CFR 72.48 and TSFST license/cask CoC renewals 1*

Second, the SOC state that licensees may adopt a new method of evaluation only if it has been specifically approved by the NRC for the intended plant/application or enjoys "generic" NRC approval. Tn addition to these cases, NET 96-07, Revision I, provides that licensees qualified per Generic Letter 83-11, Supplement I, to perform safety

analyses may adopt methodologies approved by the NRC for other plants provided the methodology is technically appropriate for the application. A similar clarification to the SOC is proposed for I 0 CFR 72.

6.8.2.3 Considerations for Determining if New or Different MOEs may be Considered "Approved by the NRC for the Intended Application" It is incumbent upon the user of a new MOE - even one generically approved by the NRC - to ensure they have a thorough understanding of the MOE in question, the terms of its existing application and conditions/limitations on its use. A range of considerations is identified below that may be applicable to determining whether new MOEs are technically appropriate for the intended application. The licensee/Coe holder should address these and simi lar considerations, as applicable, and document in the I 0 CFR 72.48 evaluation the basis for determining that an MOE is appropriate and approved for the intended application. To obtain an adequate understanding of the MOE and basis for determining that it is approved for use in the intended application, the licensee or CoC holder shou ld consult various sources, as appropriate. These include SERs, topical reports, licensee correspondence with the NRC and licensee or CoC holder personnel fami liar with the existing application of the MOE. If adequate information cannot be found on which to base the intended application of the MOE, the MOE should not be considered "approved by the NRC for the intended application."

When considering the application of an MOE, it is necessary to adopt the MOE in its entirety and apply it consistent with applicable terms, conditions and limitations.

Mixing attributes of new and existing MO Es is considered a change to an element of an MOE and must be evaluated as such per the guidance in Section 6.8.1. A new or different MOE may be considered approved for the intended application under another license, CoC, or amendment thereto, with certain conditions. The following guidance is adapted from Attachment 4 to Reference I, recognizing that Reference I applies to power plant licensees and power reactors.

The guidance for determining when a new or different MOE, which has not been generically approved by the NRC, is "approved for the intended application," per criterion (viii) of I 0 CFR 72.48, would include the following restrictions:

The new or different MOE must be used only by the same design authority as the originally approved MOE.

There must be a Generic Letter (GL) 83-11, Supplement I-type qualification process for the user of the new method (Reference 2). (Note that GL 83-11 is intended for power plant licensees who wish to perform safety analyses that had customarily been performed by nuclear steam supply system vendors. Cask design authorities should have this type of qualification process embedded in their NRC-approved QA programs required as part of the cask design approval.)

The licensee or CoC holder is able to identify all conditions and limitations under which the MOE received NRC approval. Conditions and limitations include, among other things, the type of analysis, the manner in which the analysis was applied, the physical configuration of the ISFSI facility or cask design, and any licensing basis restrictions. The licensee or CoC holder must assure that all limitations and restrictions are applicable to the ISFSI facility or cask design in question and the MOE is then applied within all conditions and limitations. For example:

o An MOE that is approved for one ISFSI facility or cask design for a particular transient cannot be applied to another ISFSI facility or cask design for a different transient because it was not approved for the other transient.

o A licensee or CoC holder is not permitted to adopt different aspects of different approved MOEs (i.e., mix and match) because the MOE is not being applied in the manner it was approved.

o An MOE that is approved for a particular JSFSI facility or cask design cannot be applied to another ISFSI facility or cask design that has relevant design differences because the method was not approved for the different design configuration.

The licensee or CoC holder is not permitted to adopt less restrictive licensing basis analysis assumptions even if they have been approved for a different ISFSI facility or cask design (e.g., it is not acceptable to credit not-important-to-safety components in accident analyses, or assume different iodine partitioning even if it is approved for another ISFSI fac ility or cask design).

6.8.2.4 Additional Considerations The fo llowing questions highlight important additional considerations for determining that a particular application of a different MOE is technically appropriate for the intended application, w ithin the bounds of what has been found acceptable by NRC, and does not require prior NRC approval.

Is the application of the MOE consistent with the ISFSI fac ility's or cask design's licensing basis (e.g., NUREG-1 536, NUREG-1 567, or other ISFSI or cask design-specific commitments)? Will the MOE supersede an MOE addressed by other regulations or the ISFSI or cask Technical Specifications?

Is the MOE consistent with relevant industry standards?

If application of the new MOE requires exemptions from regulations or ISFSI-or cask-specific commitments, exceptions to relevant industry standards and guidelines, or is otherwise inconsistent with an ISFSI fac ility's or cask's licensing basis, then prior NRC approval may be required. The

applicable change process must be fo llowed to make the ISFSI facility's or cask's licensing basis consistent with the requirements of the new MOE.

If a computer code is involved, has the code been installed in accordance with applicable software Quality Assurance requirements? Has the ISFSI-or cask design-specific model been adequately qualified through benchmark comparisons against test data, empirical data, or approved engineering analyses? Is the application consistent with the capabilities and limitations of the computer code? Has industry experience with the computer code been appropriately considered?

The computer code installation and ISFSI or cask design-specific model qualification is not directly transferable from one organization to another. The installation and qualification should be in accordance with the licensee's or cask CoC holder's Quality Assurance program.

Is the ISFSI facility or cask design for which the MOE has been approved designed and operated in the same manner as the ISFSI fac ility or cask design to which the MOE is to be applied? Is the relevant equipment the same? Does the equipment have the same pedigree? Are the relevant failure modes and effects analyses the same? If the ISFSI fac ility or cask design is designed and operated in a similar, but not identical, manner, the fo llowing types of considerations should be addressed to assess the applicability of the MOE:

How could those differences affect the MOE?

Are additional sensitivity studies required?

Should additional single failure scenarios be considered?

Are analyses of limiting scenarios, effects of equipment failures, etc., applicable for the specific ISFSI or cask design?

Can analyses be made while maintaining compliance with both the intent and literal definition of the MOE?

Differences in the JSFSI or cask design configurations and licensing bases could invalidate the application of a particular MOE. For example, the licensing basis of older vintage cask designs may not have been required to consider the same isotopes for offsite dose calculations as those in the licensing basis for more recent vintage cask designs. The existence of these differences does not preclude application of a new MOE to an TSFSI fac ility or cask design; however, differences must be identified, understood and the basis documented for concluding that the differences are not relevant to determining that the new application is technically appropriate.

References to be added to NET 12-04:

I.

USNRC Memorandum from E. McKenna to C. Carpenter, "Summary of November 2, 1999 meeting with the Nuclear Energy Institute (NET) on Revision to NET 96-07 on Implementation of I 0 CFR 50.59 - Methods of Evaluation," dated November I 0, 1999 (ML993260078).

2.

USNRC Generic Letter 83-11, "Licensee Qualification for Performing Safety Analyses in Support of Licensing Actions," dated February 8, 1983 and Supplement I, dated June 24, 1999.

3.

Questions and Answers on I 0 CFR 50.59 and NEI 96-07, Revision I, Update 4 - April 200 I (provided).