EBASCO PLANT SERVICES INC.
AS ubs1diary of ESASCO SERVICES INCORPORATED wo World Trade Center, New York, N.Y. 10048 ST. LUCIE PDÃZ UNIT NO. 2 NUCLEAR POWER PLANT FZ. PIERCE, FLORIDA DOCKET NUMBER 50-389 REACZOR CONZAINMENT BUILDING IÃQMRATI93 LEAKAGE RATE TEST FINAL REPORT Prepared for:
FLORIDA POWER & LIGHT COMPANY Prepared by:
J J Graass
,Senior Enginee Approved by:
P B Dillon Manager Plant Test & Startup Date of Test Completion:
December 2, 1982 BSoaosoiSl BS0Soa PDR ADOCK 05000389
- A ,
TABLE OF CONTENTS
~Pa e INTRODUCTION S RQZ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
~ ~ ~
TEST DISCUSSION A. Description of the Containment B. Description of ILRT Test Instrumentation ................ 4
- l. Temperature Instrumentation ......................... 5
- 2. Humidity Instrumentation ............................ 5
- 3. Pressure Instrumentation ............................ 5 4 ~ Flow Instrumentation ................................ 6 C. Containment Pressurization Equipment D. Description of the Computer Program .....................
E. Description of the Testing Sequence IV. ANALYSIS AND INTERPRETATION ..................... ~ ~ ... ~ . ~ o ~ ~ .
V. FIGURES ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ I~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
14-18
- 1. RTD Location and Volume ................................. 14
- 2. RHD Location and Volume 15
- 3. Flow Diagram for Pressure Sensing & Controlled Leakage .. 16
- 4. Flow Diagram for Pressurization System .................. 17
- 5. Test Sequence ........................................... 18 VI. APPENDICES (COMPUTER GENERATED REPORT)
A. Reduced Pressure ILRT
- 1. Temperature Stabilization
- 2. Integrated Leakage Rate Test (ILRT)
- 3. Verification Controlled Leakage Rate Test B. Peak Pressure ILRT
- 1. Temperature Stabilization
- 2. Integrated Leakage Rate Test (ILRT)
- 3. Verification Controlled Leakage Rate Test
)4~ M I. INTRODUCTION A series of two preoperational Type "A" Integrated Leakage Rate Tests (ILRT) were performed on the primary containment structure of the Florida Power & Light Company St Lucie Plant Unit No. 2 Pressurized Water Reactor.
These ILRT tests were performed in conjunction with the ASME Section III, Class MC, Containment Overload Test.
The ILRT tests were performed using the "Absolute Method" of testing in accordance with the Code of Federal Regulations, Title 10, Part 50, Appendix J
- 'Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors; and in accordance with ANSI N45.4 - 1972, American National Standard Leakage-Rate Testing of Containment Structures for Nuclear Reactors. The first ILRT test was performed at a containment pressure equivalent to one-half of the peak accident internal pressure. The purpose of this test was to obtain a measured leakage rate to be used in determining the acceptance criteria should a reduced pressure periodic leakage rate program be elected for future testing. The second ILRT test was performed at a pressure in excess of the calculated peak containment internal pressure related to the design basis accident and specified in the Final Safety Analysis Report (FSAR) and the Technical Specifications.
This report describes and presents the results of these preoperational Type "A"
~
leakage rate tests, including the supplemental test method utilized for verification. ~
II.
SUMMARY
To prepare the containment and associated systems penetrating the containment for the Type "A" ILRT, Type "B" Local Penetration leakage rate tests and Type "C" Local Containment "C" Isolation Valve leakage rate tests were performed. These Type "B" and Type tests, collectively called Local Leakage Rate Testing (LLRT), are described in Section 6.2 of the FSAR. One containment isolat'ion valve exhibiting high leakage, I-V-25-20, could not be repaired prior to the ILRT and was blanked for the test. This valve is a twenty-four inch check valve installed in the Vacuum Relief System.
Prior to pressurization of the containment vessel all containment systems and isolation valves were lined up to simulate accident conditions as described in Section 6.2 of the FSAR.
Pressurization of the containment vessel was performed to support the Containment Overload Test sequence as defined by Chicago Bridge 6 Iron Company (CB&I) the containment vessel supplier. This test sequence was performed as
,specified by the ASME,Code, Section III for Class MC Vessels and included solution film tests for welded joints and pressurization of the containment to
,the overload test pressure of 50 psig. During the high pressure solution film test, ILRT leak survey teams found excessive leakage through 3/8 inch solenoid valve 2I-SE-05-lE and blanked the valve. This valve is the outboard Containment Isolation Valve for the Safety Injection Tank Sample system.
The containment vessel was depressurized to 23 psig to allow performance of the low pressure ILRT. After an extended containment atmosphere stabilization period, containment leakage rate data was acquired for a twenty-four hour period. The simple mass point leakage rate was calculated as -0.006%/day. The fitted mass point leakage rate for the same period was -0.010%/day with an upper confidence level (UCL) calculated as
-0.009%/day. The acceptance criteria for the low pressure ILRT is that measured leakage plus uncertainties be less than .265%/day (.75 times the low pressure design leakage). The supplementary verification Controlled Leakage Rate Test (CLRT) results verified the measured leakage within the allowable acceptance band.
The containment was then repressurized to slightly above 44 psig 'to allow performance of the high pressure ILRT. The containment atmosphere was allowed to stabilize and the accumulation of containment leakage rate data was initiated. The period of data acquisition was extended beyond twenty-four hours due to a power failure on "the ILRT test instrumentation. The simple mass point leakage rate was calculated as 0.026%/day. The fitted mass point leakage rate for the same period was 0.024%/day with a UCL calculated as 0.026%/day. The acceptance criteria for the high pressure ILRT is that
~ ~
measured leakage plus uncertainties be less than 0.375%/day (.75 times the containment design leakage). The high pressure CLRT results verified the measured leakage within the allowable acceptance band.
Subsequent to the ILRT, repairs and LLRT measurements were made on the two penetrations which were blanked during the ILRT. The as-left leakage values for these valves were added to the ILRT measured leakage. The local leakages measured for these valves were less than 0.00003%/day and, therefore, nondetectable compared to the results quoted above. LLRT measurements were also performed on the three piping penetrations which were in service during the ILRT. The local leakages measured for these valves were less than 0.00002 percent/day and, therefore, nondetectable compared to the ILRT results quoted above.
III. TEST DISCUSSION A. Descri tion of the Containment The containment vessel completely encloses the entire reactor and reactor coolant system to ensure no leakage of radioactive materials to the environment in the unlikely event of a loss of coolant accident.
The containment system design incorporates a free-standing containment vessel surrounded by a low leakage concrete shield building. A four-foot annular space is provided between the outer wall of the containment vessel and the inner wall of the shield building to allow filtration of containment vessel leakage during accident conditions to minimize off-site doses.
The free-standing containment vessel is a two-inch thick right circular cylinder with a one-inch thick hemispherical dome and two-inch thick ellipsoidal bottom. The overall vessel dimensions are 140-foot diameter by 232-foot high. The vessel wall thickness is increased to a minimum of four inches adjacent to all penetrations and openings. The vessel is fabricated of
.ASME-SA 516 Grade 70 fully killed pressure vessel quality steel plate. The net free volume of the containment vessel is 2.5 x 10 6 cubic feet.
The containment vessel structure includes one personnel airlock, one emergency escape lock, one fuel transfer tube, one equipment maintenance hatch and one seal-welded construction hatch. All process piping and electrical penetrations are welded directly to the containment vessel nozzles with the
~
exception of the main steam, main feedwater and fuel transfer tube penetrations. These penetrations are provided with testable multiple ply expansion bellows to allow for thermal growth or building differential motion.
The containment vessel is designed and constructed in accordance with the requirements for Class MC vessels contained in Section III of the ASME code. The containment vessel is code stamped for a design internal containment pressure of 44 psig at a temperature of 264'F. The containment vessel and all penetrations are designed to limit leakage to less than 0.5 percent by weight of the contained air per day at the above design conditions.
The calculated peak accident pressure for the design basis accident for the St Lucie Plant Unit No. 2 is 43.4 psig.
B. Descri tion of ILRT Test Instrumentation The containment system was equipped with instrumentation to permit leakage rate determination by the "absolute method." Utilizing this method, the actual mass of dry air within the containment is calculated. The leakage
ate becomes the time rate of change of this value. The mass of air (Q) is calculated according to the Perfect Gas Law as follows:
(P-Pv) V RT where: P Containment Total Absolute Pressure Pv Containment Water Vapor Pressure V Containment Net Free Volume R Gas Constant T - Containment Absolute Temperature The primary measurement variables required are containment absolute pressure, containment relative humidity and containment temperature as a function of time. During the supplementary verification test, containment bleed-off flow is also recorded.
The Instrument Selection Guide or ISG is used to determine the ability of the instrumentation system to measure the leakage rate. The calculated ISG for this test met all acceptance criteria for all test instrumentation systems.
- 1. Tem erature Instrumentation Forty precision Resistance Temperature Detectors (RTDs) were located throughout the containment to allow measurement of the volumetrically weighted average air temperature. The location of the temperature detectors n the containment is depicted in Figure 1. Each RTD sensor was supplied with calibrated resistance vs temperature curve accurate to +O.loF. The sensitivity and repeatability of each RTD sensor is less than +0.01oF.
The signal conditioning circuit and readout for the RTD sensors was
,a LGN 914 Numatron digital meter. The signal conditioning circuit and readout were calibrated to a total loop accuracy of +0.3oF. The signal conditioning circuit and readout operating as a total loop with an RTD in the circuit had a repeatability of +0. Ol F, a sensitivity of +0.01oF and a resolution of
+0.0loF.
- 2. Humidit Instrumentation Ten Resistance Humidity Detectors (RHDs) were located throughout the containment to allow measurement of the volumetrically weighted average containment vapor pressure. The location of the RHDs in the containment is depicted in Figure 2. The calibrated accuracy of the RHDs is +2.5 percent RH, the repeatability of the RHDs is +0.25 percent RH and the sensitivity of the RHDs is +0.1 percent RH.
The readout device used for the RHDs was a Fluke 2240C datalogger. The repeatability of this device is +0.01 percent RH while the resolution of the device is +0.01 percent RH.
- 3. Pressure Instrumentation Two precision quartz bourdon tube manometers were used to determine containment absolute pressure. The arrangement of the tubing connections between the manometers and the containment is shown in Figure 3. Either manometer could be used as the primary pressure sensor for leakage rate alculations with the remaining sensor being considered as a backup. The calibrated accuracy of the manometers is +0.015 percent of reading or
+.009psi for the high pressure test. The sensitivity, repeatability and resolution of the manometers is +0.001 psi.
- 4. Flow Instrumentation Two variable area float-type rotameters were used to superimpose leakage during the supplementary CLRT. The piping connection between the rotameters and the containment is shown in Figure 3. One of the rotameters was calibrated for the low pressure test and the other rotameter was calibrated for the full pressure test. The accuracy, repeatability and sensitivity for the two rotameters in units of SCFM and converted to equivalent leakage values is given below:
Equivalent Low Pressure Rotameter Accuracy +0.12 +0.0028 %/day Repeatability +0.03 +0.0007 %/day Sensitivity +0 03
~ +0 ~ 0007 %/day High Pressure Rotameter Accuracy +0.20 +0.0029 %/day Repeatability +0,05 +0.0007 %/day Sensitivity +0.05 +0.0007 %/day C. Containment Pressurization E ui ment The equipment used to pressurize the containment is shown in Figure 4.
The nine oil-free industrial diesel driven air compressors had a total nominal capacity of 10,000 ACFM. The compressed air was then routed to the FP&L ILRT dryer trailer for processing prior to entering the containment vessel. This trailer contained water cooled aftercoolers, moisture separators, deliquescent oil filters, refrigerant air dryers and a final post filter. This equipment assured that clean and dry air was used to pressurize the containment.
D. Descri tion of the Com uter Pro ram The Ebasco ILRT computer program is an interactive Fortran IV program written specifically for fast, easy utilization during all phases of the ILRT and CLRT. Data entry and modifications, if necessary, are readily accomplished by the data acquisition team. In addition to extensive data verification routines, the program calculates, on demand, total time and mass point leak rates as well as the 95 percent Upper Confidence Level for these leakage rate calculations.
Data rejection based upon the Chauvenet criterion may be utilized in the analysis, if required.
Data evaluations are enhanced by the flexible display of either sensor variables or various computed values in tabular or graphical form on the computer terminal. Data is recorded on tape to prevent loss during the testing. All data is stored on the computer systems in use with retrieval capability to any desired data base throughout the testing.
Temperature, pressure and humidity data are entered interactively via the computer terminal at 15~inute intervals. Computer verification and checking routines supplement data verification by the data acquisition team.
Modifications are promptly made when errors are detected. Prior to issuance of this report, further extensive data verification was performed.
Descri tion of the Testi Se uence On November 24, 1982 an inspection of the containment vessel and
.internal components was made to prepare the containment for pressurization.
,.ILRT instrumentation response checks were made to ensure proper operation of all sensors and associated equipment. These sensor response checks determined that RHD 2 and RTD 16 were defective and deleted from the computer alculations.
Penetration 67, valve V-25-20 on the Containment Vacuum Relief System was blanked off for the ILRT due to excessive leakage on the valve determined during LLRT testing.
The containment was declared ready for pressurization and the air compressors started on 2050 hours0.0237 days <br />0.569 hours <br />0.00339 weeks <br />7.80025e-4 months <br /> on November 24, 1982. The sequence of pressure testing for the containment is graphically depicted on Figure 5.
At 2255 containment pressurization was secured at 5.4 psig to allow for the low pressure solution film test portion of the CB&I overload test sequence. During the solution film test, ILRT leak survey teams found and repaired minor leaks on two containment pressure transmitters caused by incomplete construction on the system. The leak survey teams found evidence of leakage on an inboard containment isolation valve on the Containment Process Radiation Monitoring System. A containment entry was made and .valve FCV-26-1 was found open with air to the pneumatic operator isolated. The closing spring on the valve was suspected to be broken or missing and the valve was closed pneumatically with a temporary compressed air bottle. The temporary air bottle was removed and the containment entry was completed.
At 1313 hours0.0152 days <br />0.365 hours <br />0.00217 weeks <br />4.995965e-4 months <br /> on November 25, 1982, after successful completion of the Low Pressure Solution Film Test, containment pressurization to the next plateau was initiated. At 1500 hours0.0174 days <br />0.417 hours <br />0.00248 weeks <br />5.7075e-4 months <br />, containment pressurization was secured at 10.5 psig internal pressure. Due to CB&I Company safety requirements for initial containment pressurization, 1 psi was bled from containment prior to personnel access. This 1 psi depressurization was complete at 1805 hours0.0209 days <br />0.501 hours <br />0.00298 weeks <br />6.868025e-4 months <br />. An internal containment inspection was made for the purpose of detecting containment leakage or evidence of internal pressure-induced structural deformation. No evidence of leakage or damage was found during the internal containment inspection.
Following maintenance on the containment ILRT pressurization equipment, pressurization of the containment to the next test plateau was initiated at 0140 hours0.00162 days <br />0.0389 hours <br />2.314815e-4 weeks <br />5.327e-5 months <br /> on November 26, 1982.
At 22 psig containment internal pressure, a brief halt in the containment pressurization was made to allow preoperational testing of the Containment Ventilation system. This test verifies operation of the Containment Fan Coolers at the equivalent air density to the steam-air mixture
- present in the containment in post-accident situations. The Containment Ventilation System operated successfully and met all design requirements.
Pressurization of the containment vessel above 22 psig was initiated at 600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br />. The pressurization was made in 5 psi steps with a nominal five-minute hold at each step in accordance with the CB&I overload test procedure.
The 50 psig overload test plateau was achieved at 1520 on November 26, 1982. Test pressure was maintained for one-hour in accordance with the CB&I overload test procedure. Depressurization of the containment to the 44 psig High Pressure Solution Film Test plateau was initiated at 1623 hours0.0188 days <br />0.451 hours <br />0.00268 weeks <br />6.175515e-4 months <br />.
The ILRT leak survey teams were deployed during the high pressure Solution Film Test plateau. The teams found the Safety Injection Tank sample line isolation Valve 2I-SE-05-1E, leaking excessively and blanked off the penetration using a cap. The High Pressure Solution Film Test was successfully completed at 44 psig concluding the CB&I overload test procedure and ASME Section III testing.
Depressurization to the Low Pressure ILRT plateau was initiated at 0855 hours0.0099 days <br />0.238 hours <br />0.00141 weeks <br />3.253275e-4 months <br /> on November 27, 1982. The test plateau was reached at 1602 hours0.0185 days <br />0.445 hours <br />0.00265 weeks <br />6.09561e-4 months <br /> at a pressure of 22.9 psig. This pressure is 1.2 psi above the required minimum pressure for the low pressure ILRT. Analysis of the ILRT instrumentation required deletion of RTD-31 from the computer program data base.
An extended containment atmosphere stabilization period prior to the ILRT was completed at 2330 hours0.027 days <br />0.647 hours <br />0.00385 weeks <br />8.86565e-4 months <br /> on November 27, 1982. Twenty-four hours
f ILRT data were accumulated showing stable data with a slightly negative leakage rate. Fitted mass point leakage rate for the primary pressure sensor indicated -0.016%/day leakage while data using the backup sensor indicated a fitted mass point leakage of -0.010%/day with a 95 percent Upper Confidence Level (UCL) calculated at -0.009%/day. The simple mass point leakage rate was calculated as -0.006%/day. The backup sensor data was selected due to three bad data points on the primary sensor caused by jarring of the device while routing temporary tubing in the vicinity. The low pressure ILRT was considered complete at 2330 hours0.027 days <br />0.647 hours <br />0.00385 weeks <br />8.86565e-4 months <br /> on November 28, 1982.
The Supplemental Verification Controlled Leakage Rate Test (CLRT) was initiated by superimposing a bleed-off flow of 11.22 SCFM, equivalent to a superimposed leakage of 0.251X/day. After allowing for a one-hour stabilization period, CLRT data taking was initiated at 0045 hours5.208333e-4 days <br />0.0125 hours <br />7.440476e-5 weeks <br />1.71225e-5 months <br /> on November 29, 1982. After four and one-quarter hours of data taking, the superimposed flow was secured. The fitted mass point leakage rate for the CLRT was 0.260X/day, well within the acceptance criteria.
Pressurization to full pressure was initiated at 0522 on November 29, 1982 with the target pressure of 45.7 psig achieved at 1249 hours0.0145 days <br />0.347 hours <br />0.00207 weeks <br />4.752445e-4 months <br />. This pressure is 2.3 psi above the required test pressure of 43.4 psig to account for the expected pressure decrease due to temperature stabilization. After a five-hour stabilization period, ILRT data taking was initiated. After twelve nd one-half hours of stable leakage rate data, a power surge/failure to the LRT RTD instrumentation readout occurred causing a transient in the data.
The data stabilized at 1215 hours0.0141 days <br />0.338 hours <br />0.00201 weeks <br />4.623075e-4 months <br /> on November 30, 1982 with an offset noticeable from the original data. At that point, data taking for the
.twenty-four hour test was reinitiated with stable data apparent. At the end of the twenty-four hours the fitted mass point leakage rate was indicated as 0.024%/day with a UCL of 0.026%/day. Simple mass point leakage rate was calculated as 0.026%/day.
~ The supplemental high pressure CLRT was initiated by superimposing a bleed-off flow of 18.66 SCFM, equivalent to a superimposed leakage of 0.267%/day. After allowing for a one-hour stabilization period, CLRT data taking was initiated at 1330 hours0.0154 days <br />0.369 hours <br />0.0022 weeks <br />5.06065e-4 months <br /> on December 1, 1982. After four and one-quarter hours of stable data, the superimposed flow was secured. The fitted mass point leakage rate for the CLRT was 0.279X/day, well within the acceptance criteria.
Containment depressurization was initiated at 1801 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.852805e-4 months <br /> on December 1, 1982. At 2055 hours0.0238 days <br />0.571 hours <br />0.0034 weeks <br />7.819275e-4 months <br />, depressurization was halted for slightly over one hour to allow movement of a truck carrying new fuel past the point where containment air was being discharged. At 1325 hours0.0153 days <br />0.368 hours <br />0.00219 weeks <br />5.041625e-4 months <br /> on December 2, 1982 the containment was at atmospheric pressure and a post-test internal inspection was made. The internal inspection showed no evidence of structural deformation or equipment damage other than two or three broken light bulbs.
Subsequent to the ILRT, the RTD instrumentation readout was placed in a post-test calibration. It was noted that a shift had occurred on the device which was identical to the shift noted during the ILRT. The shift was within the calibration accuracy requirements for the device and all other aspects of the readout were satisfactory. The readout was considered operable and the data taken with the device considered satisfactory.
Inspections and repairs were made on three process piping penetrations following the ILRT period. Included were valves V-25-20 (CONTAINMENT VACUUM RELIEF SYSTEM) and 2I-SE-05-1A through 2I-SE-05-1E (SAFETY INJECTION TANK SAMPLE SYSTEM) which exhibited high leakage and the penetrations were blanked either prior to or during the ILRT period. Post-repair LLRT tests were performed with nondetectable leakage resulting. Valve FCV-26-1 (CONTAINMENT PROCESS RADIATION MONITORING SYSTEM), which was found stuck open during the ILRT, was inspected and adjusted by the vendor. Subsequent functional tests and an LLRT test were performed with nondetectable leakage results.
The three penetrations which were in use during the ILRT were subjected to LLRT tests with nondetectable leakage resulting.
IV. ANALYSIS AND INTERPRETATION The AS1K Code Containment Overload Test and Integ'rated Leakage Rate Tests were performed as a portion of the Preoperational Test Program for the St Lucie Plant Unit No. 2 containment between November 24, 1982 and December 1, 1982. Description of the Containment Overload Test to fulfill ASME Section III requirements is covered elsewhere. A successful reduced pressure and peak pressure ILRT program was conducted with the final measured leakage rate at peak pressure reported as 0.024 percent per day. The 95 percent Upper Confidence Level for this measurement was 0.026 percent per day. The acceptance criteria for this test is 0.375 percent per day or 75 percent of the containment design leakage.
The first section of the low-pressure ILRT test plateau was containment atmosphere stabilization. As shown in Appendix A.l, temperature stabilization criteria of 0.5 F/hr rate of change difference between the last hour and the last four hours was met in 4.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br />. The atmosphere stabilization was extended for another 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> to assure adequate mixing of the containme'nt air following depressurization. The ILRT measurements were taken for a 24-hour period and are presented in Appendix A.2.
The Instrument Selection Guide (ISG) was calculated to be 0.00467 rcent per day prior to the Reduced Pressure ILRT and calculated to be 0476 percent per day after the test. The ISG limit was 0.25 x La (0.25 x
.354 percent per day) or 0.0885 percent per day. The difference between the pre- and post-test ISG calculations was due to the deletion of humidity sensor number 2, temperature sensor number 16 and temperature sensor number 31.
The Reduced Pressure Test results yield a -0.010 percent per day fitted I mass point leakage rate with a -0.009 percent per day Upper Confidence Level.
The simple mass point leakage rate was calculated as -0.006 percent'er day.
The negative measured leakage during the Reduced Pressure Test was caused by a combination of factors. First, the predicted maximum probable temperature error was 0.00158 F; however, the calculated maxim'um probable temperature error based on actual test data was 0.016 F. This was due to the manual acquisition of temperature data. Second, the actual containment leakage was so small that slight data taking errors prevented an accurate measurement and essentially masked the true leakage rate.
Given a near'ero leakage, the probability of a measured leakage yielding a negative result does exist. During this test the temperature data created a higher than normal, but acceptable, maximum probable temperature error. This influenced the mass point calculations just enough to cause a slight negative slope. To demonstrate just how small this influence was, if the calculated mean temperature for the last sample was only 31 thousandths of degree higher, the resultant total time leakage would have been positive.
Revision 1 (2!25/83)
( The likelihood of "out gassing" being a contributor to the negative leakage is not supported by the events and facts surrounding the Reduced Pressure Test. "Out gassing" would create a parabolic image in the containment mass plot whereas the latter part of the mass plots would show a trend in the direction of lower mass points. This is because the time spent at a higher containment pressure prior to reducing to a lower containment pressure fox the test was relatively short compared to the ILRT. If "out gassing" were a factor, it surely would be indicated with a mass point trend change within the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test period. Appendix A.2 shows that the mass points maintained a steady direction with no decreasing trend.
Appendix A.2 shows in tabular and graphic form the sensor values and the resultant calculations. The plot entitled, "Containment Air Masses" shows the negative sloped trend of air mass with a slight increase in "scatter" at the end of the test. Again, there is no parabolic trend indicating the possibility of "out gassing". The plot entitled, "Computed Leak Rates" presents the relationship of simple mass point (total time) calculations with fitted mass point calculations. The plot entitled, "Computed Leak Rate Relative to Limits" provides the relationship of measured leakage and UCL (95 percent Upper Confidence Limit) with acceptance criteria. The remaining plots in Appendix A.2 show temperature, pressure and vapor pressure data.
Based upon the above discussions, the issue of a negative leakage rate uring the low pressure ILRT is resolved satisfactorily to Florida Power and Light Company.
Following the Reduced Pressure ILRT, the measured leakage of
-0.010 percent per day was verified by a Controlled Leakage Rate Test (CLRT) which imposed a calibrated leakage of 11.22 SCFM which equates to 0.251 percent per day leakage. The measured results of the CLRT fell well within the criteria band of 0.153 percent per day and 0.330 percent per day and verified the Reduced Pressure ILRT measured results. The formulation of this criteria band is discussed in Appendix A.3 followed by the CLRT tables and plots.
The Peak Pressure ILRT met the temperature stabilization criteria in 4.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br />. A graphic and tabulated presentation of the temperature stabilization is shown in Appendix B.l. Initially, the ILRT began at 1745 hours0.0202 days <br />0.485 hours <br />0.00289 weeks <br />6.639725e-4 months <br /> November 29, 1982. A temperature transient or shift then occurred a day later necessitating a restart of the main portion of the ILRT. The Peak Pressure ILRT continued until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of data and 97 samples were used as a basis for the leakage rate calculations.
The ISG was calculated to be 0.00265 percent per day prior to the test and calculated to be 0.00270 percent per day after the test. The ISG limit is 0.25 x La (0.25 x 0.5) or 0.125 percent per day. The difference between the pre- and post-test ISG calculations is due to the deletion of humidity sensor number 2, temperature sensor number 16 and temperature sensor number 31.
Appendix B.2 shows in tabular and graphic form the sensor values and resultant calculations. The plot entitled, "Containment Air Masses" shows a low frequency process change where mass points are initially above the regression line then continue to cycle below and again above. This presentation is not unusual and is a result of the scale which tends to amplify existing conditions. The data was smooth and possessed no abnormal trends nor outlying points. The plot entitled, "Computed Leak Rates" presents the relationship of simple mass point (total time) calculations with fitted mass point calculations. As expected, the two calculations drew closer as the test progressed. The plot entitled, "Computed Leak Rates Relative to Limits" is the keynote of the test. This plot shows the relationship of the measured leakage with its respective UCL (95 percent Upper Confidence Limit) to the acceptance criteria and notably well below limits. The remaining plots in Appendix B.2 show temperature, pressure and vapor pressure data.
Following the Peak Pressure ILRT, the measured leakage of 0.024 percent per day was verified by a controlled leakage rate test (CLRT) which imposed a calibrated leakage of 18.66 SCFM or 0.267 percent per day. The measured results of the CLRT fell within the criteria band of 0.166 percent per day and 0.416 percent per day. The formulation of this criteria band is discussed in Appendix B.3 followed by the CLRT tables and plots.
The post-ILRT Local Leakage Rate Test results are discussed in Section II.E of this report. The results have no influence on the measured leakages of the ILRT.
To allow the option of performing a reduced pressure ILRT in future periodic ILRT tests, 10CFR50 Appendix J directs that the leakage acceptance criteria for a reduced pressure test to be established by using the results of the preoperational reduced pressure and peak pressure ILRTs. However, the reduced pressure leakage result is negative which when applied in the formula La (Ltm/Lam) yields a negative answer and generates an unreasonable test criteria. Therefore, the reduced pressure ILRT criteria for St. Lucie Unit No. 2 is determined by the alternate formula La(Pt/Pa) 1/2
.5 (21.995/43.99) / ~ 0.354 percent per day.
RTD LOCATION/VOLUME ST. LUCIE UNIT NO. 2 FLORIDA POWER 5 LIGHT COMPANY 3 RTD'S AT EL 194'OLUME 242,055 CU FT 9 RTD'S AT ELEVATION 171'OLUME 458,280 CU FT 10 RTD'S AT ELEVATION 130'OLUME 669,625 CU FT 10 RTD'S AT ELEVATION 84'OLUME 600,925 CU FT 8 RTD'S AT ELEVATION 40'OLUME 534,160 CU FT RHD LOCATION/VOLUME ST. LUCIE UNIT NO. 2 FLORIDA POWER & LIGHT COMPANY 3 RHD'S AT ELEVATION 171'OLUME 1,049,347 CU FT VOLUME 900,640 CU FT
~
4 RHD'S AT ELEVATION 84'>
3 RHD'S AT ELEVATION 40'OLUME 550,013 CU FT FLOW IAGRAM ILRT PRESSURE SENSING & CONTROLLED LEAKAGE INST Pl INSIDE OUTSIDE CONTAINMENT CONTAINMENT 3/8" TUBING 1/2" TUBING (TYP.)
3/8" X 'I/2" EXP.
P QUARTZ 52D BOURDON CONDENSATE POT TUBE MANO- TO ATMOS.
(TYP.)
METER QUARTZ Pl BOURDON Fl VAR IABLE AR EA ROTAMETER TUBE MANO-LLR TEST 1/2" DRAIN 5 TEST METER 1"'PIPE I
Fl P 1" X 1/2" R ED.
520 (TYP.)
LLR TEST 1/2" DRAIN & TEST SEISMIC CLASS I
FLOW IAGRAM ILRT PRESSURIZING 8 RESSURIZING SYSTEM TO ATMOSPHERE TO UNIT NO. 1 ILRT PENETRATION 8" PIPE 8" PIPE I
I SEISMIC CLASS I Pl Pl SPECTACLE I FLANGE ITYP) I I 8" I BLIND 54 REMOVE I
DRIP FOR ILRT I
POT 6" BLIND I 2" BYPASS I %"
%" LLR 5 DRAIN LLR I I I
1" DRAIN OUTDOORS I INSIDE OUTSIDE INSIDE I AUXluARV CONTAINMENT CONTAINMENT I BLDG.
FPSL ILRT DRYER TRAILER F ILTER WATER OUT WATER IN AIC I
REFRIG- WATER OUT I ERANT MOISTURE AIC I DRYER I / SEPAR.
ATOR I AUTO AFTER AIC I DRAIN COOLER I (TYP)
I ale DIESEL DRIVEN POST AUTO INDUSTRIAL FILTER DRAIN WATER IN OIL FREE AIC I ITYP) WATER OUT AIR COMPR ESSORS I (10,000 CFM TOTAL)
I AIC I AFTER I COOLER AIC I
I FILTFR MOISTURE I
REFRIG- SE PAR. AIC ERANT I DRYER WATER IN I
WATER OUT WATER IN AIC I
I
ST. LUCIE PLANT UNIT NO. 2 TEST SEQUENCE Qo 50 QK OL 45 QE 40 QM I
QA 5 PSIG SOAP BUBBLE TEST QB 10 PSIG CONTAINMENT INSPECTION 30 FAN TEST QG Qp OVERLOAD TEST 25 QF QH HIGH PRESSURE SOAP BUBBLE TEST CO QF QF LOW PRESSURE TEMPERATURE I STABILIZATION 20 QG LOW PRESSURE ILRT QH LOW PRESSURE CLRT 15 QI HIGH PRESSURE TEMPERATURE STABILIZATION QB QJ INTERRUPTED TEMPERATURE POINT 10 QK HIGH PRESSURE ILRT I
QA QL HIGH PRESSURE CLRT i !
5 I OM 0EPRESSUR IZATION INTERRUPTION 11-26-82 11-28-82 11-30-82 11-2542 11-27-82 SUN 11-294I2 TUE 12-1-82 FRI THUR SAT MON WED
TEMPERATURE STABILIZATION C D 1615 78.916 1630 79 '56 1645 80.313 1700 80.634 1715 80.857 1730 81.026 1745 81.163 1800 81.289 1815 81.381 1830 81.491 1845 81.562 1900 81.639 1915 81.700 1930 81.761 1945 81.825 .
2000 81.876 2015 81.927 0.753 0.227 0 ~ 526 2030 81.962 0.527 0.201 0.326 2045 82.015 0.426 0.190 0.236 2100 82.059 0.356 0.183 0.173 2115 82.093, 0.309 0.166 0.143 2130 82.133 0.277 0 171 0.106 2145 82.169 0.252 0.154 0.098 2200 82.207 0.223 0.148 0-075 2215 82.230 0.212 0.137 0.075 2230 82 '63 0.193 0.130 0.063 2245 82.288 0.182 0.119 0.063 2300 82.318 0.155 0.111 0.044 2315 82.341 0.145 O.ill 0.034 A = TIME OF DAY IN MILITARY STANDARD B = AVERAGE CONTAINMENT TEMPERATURE F C = AVERAGE DIFFERFNCE IN TEMP. OVER LAS 4 HOURS D = AVERAGE DIFFERENCE IN TEMP. OVER LAST 1 HOUR E = C - D
9 ~ 17 ~
)1 ~
83.90 TEMP ERRTURE STAB IL I ZRT ION c
C4 LLJ cv QJ 82.90 CC'al I
(Z CP 0
CC 5
81.90 le Cl W
Cl a
a 80.90 79-90 78.90
- 16. 5 17 15 18.15 19.15 20.15 21-15 22.15 23.15 TIME HOUR5 (MILITRRY STRNORRD)
V 0
FLORIDA POWER 6c LIGHT COMPANY ST LUCIE PLANT UNIT NO. 2 CONTAINMENT INTEGRATED LEAKAGE RATE TEST LEAKAGE RATE MEASURED USING THE ABSOLUTE METHOD LEAKAGE RATE COMPUTED USING THE MASS POINT METHOD TEST PERIOD STARTED AT 2330 HOURS ON NOVEMBER 27, 1982 TEST CONDUCTED FOR 24.00 HOURS FREE SPACE VOLUME OF .CONTAINMFNT IS 2500000 CU FT CONTAINMENT WAS PRESSURIZED TO 38.04 PSIA INITIAL CONTAINMENT AIR WEIGHT 468786.4 LBS FINAL CONTAINMENT AIR WEIGHT 468812.6 LBS FITTED MASS POINT LEAKAGE RATE IS .010 0 PER DAY UPPER LIMIT OF 95o CONFIDENCE LEVEL IS ~ 009 I PER DAY NRC MAXIMUM ALLOWABLE LEAKAGE RATE IS 0 354 o PER DAY
0 4
DESCRIPTION OF VARIABLES AVG. TEMi CONTAINMENT MEAh'EMPERATURE CALCULATED FROMi VOLUMETRICALLY WEIGHTED RTD SENSOR INDICATIONS.
AVE. PRE- PRIMARY CONTAINMENT PRESSURE INDICATION.
VAP. PRE CONTAINMENT VAPOR PRESSURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RHD SENSOR INDICATIONS.
LEAK SXMi- SIMPLE TOTAL TiME LEAKAGE RATE.
LEAK MAS LEAKAGE RATE COiMPUTED FROM FIRST ORDER REGRESSION OF AXR MASS DATA.
AIR MASS CONTAINMENT AIR MASS.
NOTE FOR TABULAR DATA TABLE VALUES OF ZERO SIGNIFY EITHER.
- i. DATA IS NOT APPLICABLE TO THE CALCULATIOh'R
- 2. SENSOR HAS BEEN DELETED FROM THE SCAN.
NOTE FOR CURVES
- i. TOP ABSCISSA SCALE REPRESENTS SAMPLE NUMBERS.
- 2. AIR i(ASS IS THE CALCULATED CONTAINMENT AIR MASS AND FITTED AIR MASS IS THE LINEAR LEAST SQUARE FIT OF THE AIR MASSES.
- 3. SIMPLE MASS POINT IS THE TOTAL TIME LEAKAGE RATE AND FiTTED MASS POINT IS THE LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MASS DATA.
- 4. UCL XS THE UPPER LIMIT OF THE 95%
CONFIDENCE LEVEL OF AIR MiASS DATA.
rARIABLE TABLE
SUMMARY
SAMPLE DELTA AVG. TEM AVG. PRE VAP. PRE LEAK SIM LEAK MAS AIR MASS NUMBER MINS DEG. F PSIA PSIA PEP. CENT PER CENT POUNDS 1 0 82.380 38.0420 0.3813 0.000 0.000 468786 2 15 82.403 38.0440 0.3814 -0.055 0.000 468789 3 30 82.425 38.0450 0.3816 0.060 0.060 468781 45 82.452 38.0480 0.3819 -0.032 -0.011 468791 5 60 82.484 38.0500 0.3822 0.013 0.006 468784 6 75 82.508 38.0520 0.3825 0.012 O.oil 468784 7 90 82.530 38.0530 0.3828 0.042 0.033 468774 8 105 82.551 38.0550 0.3831 0.026 0.033 468778 9 120 82.569 38.0570 0.3832 0.004 0.021 468785 10 135 82.591 38-0590 0.3834 -0.004 0.010 468788 ll 12 150 165 82.607 82.647 38.0600 38-0620 0.3836 0.3841 0.004 0.034 0.007 0.018 468785 468768 13 180 82.644 38.0630 0.3840 0 '02 0.012 468785 14 195 82.660 38.0640 0.3843 0.011 0.012 468780 15 210 82.674 38.0660 0.3844 -0.008 0;005 468792 16 225 82.700 38.0670 0.3847 0.012 0.007 468777 17 240 82.716 38.0690 0.3849 0.001 0.004 468786 18 255 82.728 38.0690 0.3850 0.014 0.007 468775 19 270 82.746 38.0710 0.3852 0.006 0.006 468781 20 285 82 '62 38.0730 0.3855 -0.003 0.003 468789 21 300 82.774 38.0740 0.3855 -0.004 0.001 468791 22 315 82.788 38.0750 0.3857 -0.002 -0.000 468788 23 330 82.805 38.0760 0.3859 0.003 -0.000 468783 24 345 82.818 38.0770 0.3861 0.004 -0.000 468782 25 360 82.831 38.0780 0.3863 0.005 0.000 468781 26 375 82.843 38.0790 0.3865 0.005 0.001 468781 27 390 82.857 38.0800 0.3867 0.006 0.001 468779 28 405 82.869 38.0810 0.3869 0.006 0.002 468779 29 420 82.884 38.0830 0.3870 -0.002 0.001 468789 30 435 82.899 38-0840 0.3873 0.001 0.001 468785 31 450 82.908 38.0850 0.3873 -0.002 -0.000 468789 32 465 82.916 38.0860 0.3875 -0.004 -0.001 468792 33 480 82.923 38 '870 0 '875 -0.008 -0.003 468799 34 495 82.942 38.0880 0.3877 -0.003 -0.003 468792 35 510 82.957 38.0890 0.3879 -0.002 -0.004 468790 36 525 82.967 38.0900 0.3880 -0.003 -0.004 468792 37 540 82.974 38.0910 0.3882 -0.005 -0.005 468796 38 555 82.988 38.0920 0.3884 -0.004 -0.005 468794 39 570 82.971 38.0930 0.3882 -0.020 -0.008 468823 40 585 82.992 38.0940 0.3885 -0.014 -0.009 46SS14 41 600 83.014 38.0940 0-3889 002 -0 009 F 468791 42 615 83.027 38-0950 0.3890 -0.002 -0.008 468790 43 630 83.031 38.0960 0.3891 -0.005 -0.009 468798 44 645 83.040 38.0970 0.3893 -0.006 -0.009 468800 45 660 83.042 38.0970 0.3894 -0.005 -0.009 468798 46 675 83 '57 38.0980 0.3895 -0.004 -0.009 468795 47 690 83.067 38.0990 0.3897 -0.004 -0.009 468796 48 705 83.077 38 '990 0.3898 0.000 -0.008 468786 49 720 83.076 38.1000 0.3899 -0.005 -0.008 468799 50 735 83.084 38.1000 0.3900 -0.002 -0.008 468790
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA AVG. TEM AVG- PRE VAP. PRE LEAK SIM LEAK MAS AIR MASS NUMBFR KINS DEG. F PSIA PSIA PER CENT PER CENT POUNDS
'51 750 83.095 38.1020 0.3902 -0.007 -0.008 468803 52 765 83.108 38.1020 0.3904 -0.001 -0.007 468790 53 780 83.111 38.1020 0.3905 0.000 -0.007 468786 54 795 83.118 38-1030 0.3906 -0.002 -0.007 468791 55 810 83.128 38.1040 0-3908 -0.002 006 468792 56 825 83.135 38.1040 0 '909 0.000 -0.006 468785 57 840 83.144 38.1050 0-3910 -0.001 -0.006 468788 58 8/5 83.149 38.1050 0.3912 0.002 -0.005 468782 59 870 83.148 38.1060 0.3912 -0.003 -0.005 468795 60 885 83.160 38.1070 0.3914 -0.003 -0.005 468795 61 900 83.170 38.1080 0.3916 -0.003 -0 '05 468795 62 915 83.171 38.1080 0.3916 -0.003 -0.005 468796 63 930 83.173 38.1080 0 '916 -0.002 -0.005 468794 64 945 83.185 38.1090 0.3918 -0.002 -0.005 468794 65 960 83.193 38.1100 0-3919 -0.003 -0.005 468797 65 975 83.i90 38-1100 0-3919 -0.004 -0.005 468799 67 990 83.197 38.1110 0.3920 -0.006 -0.005 468805 68 1005 83.20i 38.1110 0.3922 -0.004 -0.005 468799 69 1020 83.203 38.1110 0.3922 -0 '03 -0.005 468798 70 1035 83.208 38.1120 0.3923 -0.005 -0.005 468805 71 1050 83.207 38'.1120 0.3923 -0.005 -0.005 468805 72 1065 83.195 38.1130 0.3922 -0.012 -0.006 468828 73 1080 83.201 38.1130 0.3923 -0.010 -0.007 468823 74 1095 83.204 38.i130 0.3924 -0.009 -0.007 468818 75 1110 83.202 38.1140 0.3924 -0.013 -0.008 468833 76 1125 83.211 38.1140 0.3926 -0.010 -0.008 468823 77 1140 83.233 38.1150 0.3929 -0.007 -0.008 468812 78 1155 83.225 38.1150 0.3928 -0.009 -0.008 468820 79 1170 83.215 38.1150 0.3928 -0.011 -0.009 468830 80 1185 83.228 38.1160 0.3930 -0.011 -0.009 468828 81 1200 83.250 38.1160 0.3933 -0.005 -0.009 468805 82 1215 83.251 38.1170 0.3934 -0.007 -0.009 468816 83 1230, 83.249 38.1170 0.3934 -0.008 -0.009 468817 84 1245 83.224 38.1170 0.3931 -0.014 009 468842 85 1260 83.249 38.1170 0.3934 -0 '07 -0.009 468817 86 1275 83.242 38-1180 0.3934 -0.012 -0.010 468834 87 1290 83 '51 38.1180 0.3936 -0.009 -0.010 468826 88 1305 83.261 38.1190 0.3938 -0.009 -0.010 468826 89 1320 83.270 38.1190 0.3940 -0.007 -0.010 468816 90 1335 83.267 38.1190 0.3940 -0.008 -0.010 468819 91 1350 .83-271 38.1200 0.3941 -0.009 -0.010 468827 92 1365 83.261 38.1200 0.3940 -0.011 -0.010 468836 93 1380 83.273 38.1200 0 '942 -0.008 -0.010 468824 94 1395 83.281 38.1200 0.3944 -0.006 -0.010 468814 95 1410 83.288 38.1210 0 '944 -0.007 -0.010 468820 96 1425 83.297 38.1210 0.3946 -0.005 -0.010 468810 97 1440 83.295 38.1210 0.3946 -0.006 -0.010 468813 END OF TABLE
VAR1ABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 1 TEMP 2 TEMP 3 TEMP 4 TEMP 5 TEMP 6 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 82.940 82.230 82.990 82.410 82.180 82.070 2 15 82.960 82.250 83.010 82.440 82.210 82.100 3 30 82.980 82.270 83-020 82.450 82.240 82.120 45 82.990 82.300 83.040 82.470 82.260 82.140 5 60 83.020 82.340 83.070 82.490 82.300 82.170 6 75 83.030 82.340 83.080 82.510 82.330 82 '90 7 90 83.050 82.380 83.100 82.540 82.350 82.220 8 105 83.070 82.390 83.120 82.560 82.370 82.240 9 120 83.080 82.430 83.130 82.570 82.400 82.260 10 135 83.100 82.490 83.140 82.580 82.420 82.280 11 150 83.110 82.450 83.150 82.600 82.440 82.290 12 165 83.200 82.530 83.220 82.660 82.510 82.340 13 180 83.140 82 '70 83.190 82.630 82.490 82.330 14 195 83.150 82.490 83.190 82.640 82.500 82.340 15 210 83.160 82.510 83.190 82.650 82.520 82.350 16 225 83.150 82.540 83.210 82.670 82.540 82.370 17 240 83.170 82.550 83.230 82.680 82.550 82.390 18 255 83-200 82.560 83.230 82.700 82.570 82.400 19 270 83.220 82.580 83.240 82.710 82.580 82.420 20 285 83.230 82.590 83.250 82.720 82.590 82-430 21 300 83.230 82.620 83.250 82.730 82.650 82.450 22 315 83.250 82.640 83.280 82.740 82.610 82.460 23 330 83.270 82.650 83-270 82.750 82.630 82.480 24 345 83-260 82.660 83-290 82.770 82.640 82.480 25 360 83.280 82.660 83.290 82.770 82 '50 82.490 26 375 83.290 82.680 83-300 82.790 82.660 82.500 27 390 83-300 82.700 83.310 82.810 82.680 82.510 28 405 83.300 82.710 83.320 82.810 82.700 82.520 29 420 83.320 82.720 83-330 82.820 82.700 82.530 30 83-330 82.740 83-340 82.820 82.710 82.530 31 450 83.340 82.760 83 '40 82.840 82.720 82.550 32 465 83.320 82.750 83.350 82.850 82.730 82.560 33 480 83.340 82.770 83.350 82.850 ,82.740 82.560 34 495 83.330 82.790 83.370 82.870 82.760 82.570 35 510 83.370 82.820 83.380 82.890 82 '60 82.590 36 525 83.380 82.810 83-380 82.890 82.780 82 '90 37 540 83.390 82. 83:0 83.390 82.890 82.790 82-600 38 555 83.400 82.820 83.390 82.910 82.790 82.610 39 570 83.400 82.820 83.390 82.900 82.800 82.610 40 585 83-380 82.810 83.390 82.880 82.780 82.610 41 600 83.420 82.850 83.410 82.920 82.820 82.640 42 615 83.440 82-860 83 '30 82.940 82.830 82.660 43 630 83.440 82.870 83.440 82.940 82.840 . 82.660 44 645 83.440 82.880 83.430 82 '50 82.840 82.660 45 660 83.450 82.870 83.430 82.940 82.850 82.670 46 675 83-450 82.900 83.450 82.960 82.860 82.680 47 690 83.460 82.910 83.450 82.960 82.870 82.690 48 705 83.430 82.920 83-470 82.970 82.880 82.710 49 720 83.470 82.920 83.470 82.980 82.880 82.700 50 735 83-480 82.940 83-470 82.980 82.880 82.720
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 1 TFMP 2 TEMP ~
3 TEMP 4 TEMP 5 TEMP 6 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750, 83.470 82.940 83.480 82.990 82.890 82.730 52 765 83.490 82.950 83 '80 83.000 82.890 82.740 53 780 83.500 82.980 83.480 83.000 82.910 82.740 54 795 . 83.490 82-960 83.490 83-010 82.920 82.750 55 810 83 '10 83.010 83.500 83.030 82.930 82.780 56 825 83.520 82.990 83.510 83.030 82.950 82-770 57 840 83.530 82.990 83 '20 83.040 82.950 82.780 58 855 83.530 83.010 83 '20 83.030 82.950 82.780 59 870 83.530 82.990 83.520 83.040 82.950 82.780 60 885 83.540 83.050 83.520 83 050 F 82-970 82.800 61 900 83.540 83.030 83.530 83.060 82.970 82.810 62 915 83-540 83.030 83.540 83.050 82.970 82.810 63 930 83-550 83.020 83.550 83.070 82.980 82.820 64 945 ,83.550 83-060 83.540 83.070 82.980 82.810 65 960 83.560 83.070 83.550 83.070 82.990 82.830 66 975 83 '60 83.060 83.550 83.070 83-010 82.830 67 990 83.560 83.060 83.550 83.080 83 F 82.830 68 1005 83.570 83 '70 83.560 83.080 000'3.010 82.840 69 1020 83.570 83.050 83.560 83.090 83.010 82.840 70 1035 83.580 83.070 83.570 83.090 83.020 82 '50 71 1050 83.580 83 '50 83.560 83.090 83.020 82.850 72 1065 83.560 83-050 83.550 83.080 83.010 82 '40 73 1080 83.570 83-060 83.550 83.080 83.020 82.850 74 1095 83.570 83 '60 83.550 83.090 83.010 82.840 75 lllo 83-560 83.070 83.560 83.090 83-010 82.860 76 1125 83.590 83.080 83.570 83.110 83.020 82 '60 77 1140 83 '00 83.090 83.590 83.110 83-030 82.890 78 1155 83-590 83-080 83.580 83.120 83 '30 82.880 79 1170 83.580 83.060 83.570 83.100 83.020 82.870 80 1185 83-600 83.080 83.580 83.120 83-030 82.880 81 1200 83 '20 83.090 83.600 83.140 83.040 82.910 82 1215 83.620 83.090 83.600 83-150 83 '50 82.900 83 1230 83 '20 83.090 83 '00 83.140 83 '50 82.910 84 1245 83.590 83.080 83.570 83.110 83.010 82.880 85 1260 83.620 83.090 83 '90 83.140 83.050 82.900 86 1275 83.610 83 080 F 83.590 83.130 83.040 82.900 87 1290 83.620 83.090 83-590 83.150 83-060 82.920 88 1305 83.630 83.110 83.600 83.150 83.060 82.920 89 1320 83.630 83.120 83.620 83.160 83.070 82.940 90 1335 83.630 83.110 83.610 83.150 83.070 82.930 91 ,1350 83.630 83.120 83.610 83.160 83.060 82.930 92 1365 83.630 83.110 83.600 83.150 83.060 82.930 93 1380 83.640 83.130 83 '00 83.160 83.,060 82.940 94 1395 83.640 83.120 83.620 83.170 83.070, 82.950 95 1410 83.650 83.140 83.630 83.170 83.080 82.950 96 1425 83.660 83.140 83.630 83.180 83.100 82.960 97 1440 83.660 83.140 83.630 83.180 83 '90 82.960 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 7 TEMP 8 TEHP DEG.
9 F
TEYiP DEG.
10 F
TEMP DEG.
ilF TEYiP DEG.
12 F
NUMBER MINS DEG. F DEG. F 1 0 82.750 82.470 81.740 82-340 82.200 80.100 2 15 82.780 82.500 81.770 82.380 82.220 80.150 3 30 82.810 82 '20 81.810 82.390 82.250 80.140 4 45 82.840 82.540 81.830 82.420 82.270 80.170 5 60 82.870 82.570 81.910 82.450 82.300 80.210 6 75 82.890 82.600 81.940 82.480 82.310 80.230 7 90 82.930 82.610 81.940 82.490 82.330 80.270 8 105 82.940 82.630 81.960 82.510 82 '70 80.290 9 120 82.960 82.650 81.990 82.530 82.380 80.300 10 135 82.980 82.670 82.010 82.550 82.410 80.320 ll 12 150 165 83.000 83.050 82.680 82.730 82.020 82.060 82.570 82.620 82.420 82.470 80.330 80.380 13 iso 83.040 82.720 82.070 82.630 82.440 80.370'0.400 14 195 83-050 82 '30 82.090 82-650 82-480 15 210 83.070 82.740 82.110 82.660 82.490 80.390 16 225 83.090 82.760 82.130 82.680 82.500 80.420 17 240 83.110 82.780 82.200 82 '90 82-530 80.450 18 255 83.120 82 '90 82.200 82 '10 82.540 80.460 19 270 83.140 82.810 82.230 82.720 82'.570 80.490 20 285 83.150 82.820 82.250 82.740 82.570 80.490 21 300 83.160 82.830 82.260 82 '50 82.590 80.500 22 315 83.180 82.850 82.270 82.770 82.610 80.520 23 330 83.190 82.860 82.290 82.770 82 '20 80.540 24 345 83.200 82.880 82.310 82.810 82 '30 80.550 25 360 83.220 82.880 82.320 82.820 82.650 80.560 26 375 83.230 82.890 82.340 82.820 82.670 80.580 27 390 83.240 82.900 82.340 82.830 82 '90 80.600 28 405 83.260 82.910 82.380 82.850 82.690 80.610 29 420 83.270 82.930 82.410 82-870 82.700 80.620 30 435 83.280 82.940 82.430 82.890 82.720 80-640 31 450 83.280 82.950 82.430 82-900 82.740 80.640 32 465 83.290 82.960 82.450 82.900 82.750 80.660 33 480 83.300 82.960 82-460 82.910 82.760 80.670 34 495 83.310 82-970 82.470 82.930 82-770 80.690 35 510 83.320 82.990 82.480 82.950 82.790 80.700 36 525 83.330 83-000 82.510 82-960 82.800 80.700 37 540 83.340 83 ~ 010 82.510 82.980 82.820 80.720 38 555 83.350 83.020 82 '30 82.970 82.810 80.730 39 570 83.350 83.020 82.520 82-970 82.800 80.720 40 585 83.340 83.010 82-530 82.990 82.820 80.720 41 600 83.360 83.040 82.570 83.010 82.850 80.750 42 615 83.380 83.060 82 '90 83.010 82.860 80.760 43 630 83.390 83.060 82.590 83.020 82.860 80.770 44 645 83.400 83.070 82.610 83.040 82.870 80-780 45 660 83.400 83 '60 82.610 83.030 82.860 80.780 46 675 83.400 83.080 82.630 83-040 82.880 80.800 47 690 83.420 83.090 82.650 83-060 82.900 80.810 48 705 83.430 83.100 82.640 83.070 82.900'2.900 80.820 49 720 83.430 83.100 82.640 83.070 80.820 50 735 83.440 83.110 82.660 83.080 82.920 80.820
0 VARiABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 7 TEMP 8 TEMP 9 TEMP DEG.
10 F
TEHP DEG.
ll F
TEMP DEG.
12 F
NUMBER MINS DEG. F DEG. F DEG. F 51 750 83.450 83 '30 82.670 83.080 82-930 80.840 52 765 83.460 83.130 82.690 83.100 82.940 80.840 53 780 83.470 83.140 82.690 83.110 82.950 80.850 54 795 83.470 83.150 82.710 83.110 82.950 80.850 55 810 83.480 83.160 82.720 83.120 82-960 80-870 56 825 83 '90 83.180 82.730 83.130 82.970 80.870 57 840 83.490 83.180 82.740 83.150 82.970 80.880 58 855 83.500 83 '80 82.750 83.140 82.980 80.890 59 870 83.500 83.190 82.760 83.140 82.970 80.890 60 885 83.520 83.190 82.760 83.150 82.980 80.900 61 900 83.520 83.200 82.770 83.160 82.980 80.900 62 915 83.520 83.200 82.780 83-170 82.990 80.910 53 930 83.530 83.200 82.790 83-170 83.000 80.920 64 945 83.540 83-210 82.790 83.180 83.010 80.920 65 960 83.550 83 '20 82.800 83.190 83.020 80.920 66 975 83.550 83.220 82.810 83.190 83.020 80.930 67 990 83.550 83.230 82.820 83.180 83.020 80.940 68 1005 83.560 83.230 82.830 83.190 83.030 80.960 69 1020 83.560 83.230 82.830 83.200 83 050 F 80.950 70 1035 83.560 83.240 82.830 83 '10 83.030 80.930 71 -
1050 83.570 83.240 82.840 83.200 83-030 80.950 72 1065 83.550 83.230 82.820 83 180 F 83-020 80.940 73 1080 83.570 83.230 82.830 83.200 83.030 80.940 74 1095 83.560 83.220 82.840 83.190 83-030 80.930 75 lllo 83.570 83.230 82.830 83.200 83-040 80.950 76 1125 83.580 83.240 82.830 83.210 83.040 80.960 77 1140 83.600 83.260 82.870 83-230 83-070 80.970 78 1155 83 '00 83.260 82.860 83.220 83.060 80.970 79 1170 83.580 83.240 82.840 83 '20 83.050 80.960 80 1185 83.590 83.250 82.870 83.230 83.060 80.980 81 1200 83.620 83.270 82.880 .83 '40 83.080 81.000 82 1215 83.620 83.270 82.880 83.240 83.090 81.000 83 1230 83.620, 83.270 82.880 83-250 83.090 80.990 84 1245 83.590 83 ~240 82.860 83.220 83-060 80.960 85 1260 83.620 83.270 82.890 83.240 83-080 80.980 86 1275 83.620 83 '60 82.890 83.240 83.070 80.990 87 1290 83.630 83 '70 82.900 83.240 83-100 81.000 88 1305 83.630 83.270 82.920 83.250 83.110 81.000 89 1320 83.640 83.280 82.940 83-260 83-120 81.020 90 1335 83.640 83.270 82.930 83.270 83-090 81.010 91 1350 83 '40 83.270 82.930 83.260 83-100 81.010 92 1365 83.640 83.270 82.920 83.250 83.110 81.020 93 1380 83.640 83.280 82.940 83 '60 83.100 81.030 94 1395 83 '60 83.290 82.960 '3.270 83.120 81.030 95 1410 83.660 83.300 82.960 83.290 83-120 81.020 96 1425 83.670 83.300 82.960 83.290 83 '20 81.030
' 97 1440 83.670 83.310 82.970 END OF TABLE 83-280 83.130 81.040
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 13 TEMP 14 TEMP 15 TEMP 16 TEMP DEG.
lj F
TEMP DEG.
18 F
NUMBER ??INS DEG. F DEG. F DEG. F DEG. F 1 0 82.310 82.140 82.480 DELETED 82.250 82.280 2 15 82.330 82.180 82-500 DELETED 82-300 82.300 3 30 82.340 82.200 82.520 DELETED 82-310 82.300 4 45 82.370 82.210 82.550 DELETED 82-360 82.330 5 60 82.400 82.250 82.580 DELETED 82.380 82.380 6 75 82.440 82 '80 82.610 DELETED 82.410 82.380 7 90 82.460 82.280 82.640 DELETED 82.430 82.390 8 105 82.470 82.310 82.660 DELETED 82.450 82.420 9- 120 82.500 82.320 82.680 DELETED 82.470 82.450 10 135 82.510 82.350 82.700 DELETED 82.490 82 '50 ll 12 150 165 82.530 82 '60 82.360 82.390 82.720 82.760 DELETED DELETED 82.510 82-550 82.470 82.510 13 180 82.570 82.390 82.770 DELETED 82.550 82.500 14 195 82.580 82.420 82.770 DELETED 82.550 82.520 15 210 82.590 82.430 82.790 DELETED 82.580 82.520 16 225 S2.61O 82.450 82.810 DELETED 82 '40 82.550 17 240 82.640 82.470 82.830 DELETED 82.650 82.580 18 255 82.650 82.480 82.840 DELETED 82.620 82.580 19 270 82.670 82.500 82.870 DELETED 82.650 82-600 20 285 82.690 82.510 82.870 DELETED 82.690 82-620 21 300 82.700 82.530 82.880 DELETED 82.710 82.630 22 315 82.720 82.540 82.910 DELETED 82.720 82.650 23 330 82.710 82.560 82.930 DELETED 82 '30 82-650 24 345 82.730 82.580 82.940 DELETED 82.740 82.690 25 360 82.740 82.590 82.960 DELETED 82.780 82-680 26 375 82.770 82.610 82.960 DELETED 82.790 82.700 27 390 82.780 82.620 82.970 DELETED 82-800 82.710 28 405 82.780 82.620 82.990 DELETED 82.800 82.720 r9 420 82.800 82.650 83.000 DELETED 82.840 82.730 30 435 S2.82O 82.660 83.020 DELETED 82.850 82.770 31 450 '82.820 82.670 83.030 DELETED 82.870 82.770
- 32. 465 82.840 82 '70 83.030 DELETED 82 880 F 82.780 33 480 82.840 82.680 83.050 DELETED 82.880 82 '90 34 495 82.870 82.720 83.070 DELETED 82.900 82.810 35 510 82.870 82.730 83.080 DELETED 82.900 82.820 36 525 82.900 82.740 83.100 DELETED 82.940 82.830 37 540 82.900 82.740 83.110 DELETED 82.920 82.830 38 555 82.910 82.760 83.110 DELETED 82.970 82.850 39 570 82.910 82.750 83.100 DELETED 82.960 82.830 40 585 82.920 82.770 83.120 DELETED 83.000 82.850 41 600 82.940 82.790 83.130 DELETED 83.010 82.870 42 615 82.960 82.800 83.150 DELETED 83.010 82.890 43 630 82.960 82.820 83.160 DELETED 82.980 82.890 44 645 82.980 82.820 83.170 DELETED 83.020 82.890 45 660 82.970 82.810 83.170 DELETED 83.020 82.890
'70 '40 j
46 675 83.000 82.820 83 DELETED 83 82.910 47 690 83.000 82.840 83.-190 DELETED 83.050 82.920 48 705 83.000 82.860 83.200 DELETED 83.070 82.940 49 720 83.000 82.850 83.210 DELETED 83.060 82.930 50 735 83 000
~ 82.860 83.210 DELETED 83.080 82.940
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 13 TEMP 14 TEMP 15 TEMP 16 TEMP 17 TEMP 18 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 83.010 82-870 83.220 DELETED 83 100 F 82.950 52 765 83.020 82.890 83.230 DELETED 83.090 82.950 53 780 83.040 82.900 83.230 DELETED 83-110 82.970 54 795 83.040 82.900 83.240 DELETED 83.110 82.970 55 810 83-040 82.910 83.240 DELETED 83.120 82.990 56 825 '3-060 82.910 83.260 DELETED 83.130 83.000 57 840 83.060 82.920 83.270 DELETED 83.140 83.020 58 855 83-070 82.930 83.260 DELETED 83.140 83.000 59 870 83-070 82.930 83.270 DELETED 83.140 83.020 60 885 83.080 82.940 83.280 DELETED 83.160 83.020 61 900 83.090 82.960 83.290 DELETED 83.160 83.020 62 915 83.090 82.950 83.290 DELETED 83.170 83.030 63 930 83-080 82.960 83.300 DELETED 83.160 83.050 945 83.090 82.960 83.310 DELETED 83.180 83.050 960 83.110 82.970 83.310 DELETED 83.180 83.050 66 975 83.110 82.970 83.300 DELETED 83.190 83.060 67 990 83.120 82.980 83.310 DELETED 83 '00 83.070 68 1005 83 '30 82.990 83.320 DELETED 83.190 83.070 69 1020 83.130 82.990 83-330 DELETED 83.190 83.070 70 1035 83.120 82.990 83.320 DELETED 83.200 83.060 71 1050 83.130 82.990 83-320 DELETED 83.200 83.070 72 1065 83.120 82.990 83.320 DELETED 83.190 83.070 73 1080 83.120 83.000 83.330 DELETED 83.190 83.070 74 1095 83.130 82.990 83.330 DELETED 83.200 83-070 75 1110 83.140 82.990 83.330 DELETED 83.200 83.070 76 1125 83.140 83.000 83.340 DELETED 83.220 83.090 77 1140 83.160 83.030 83.360 DELETED 83.240 83.110 78 1155 83.160 83.030 83-350 DELETED 83.220 83.100 79 1170 83.140 83.010 83.340 DELETED 83.220 83.090 80 1185 83.150 83.020 83.350 DELETED 83.220 83.100 81 1200 83.190 83.040 83.380 DELETED 83.240 83.130 82 1215 83.190 83.040 83.370 DELETED 83.240 83.130 83 1230 83.190 83.040 83.380 DELETED 83.250 83.130 84 1245 83.180 83.010 83.350 DELETED 83.190 83.100 85 1260 83.190 83.040 83.380 DELETED 83.230 83.120 86 1275 83.190 83.030 83.360 DELETED 83.230 83.120 87 1290 83.200 83.020 83.370 DELETED 83.240 83.130 88 1305 83.210 83.050 83.380 DELETED 83.250 83.150 89 1320 83.220 83.050 83.390 DELETED 83.250 83.160 90 1335 83.210 83.060 83.390 DELETED 83.250 83.150 91 1350 83.220 83.060 83.400 DELETED 83.270 83.150 92 1365 83.220 83.050 83.390 DELETED 83.250 83.150 93 1380 83.230 83.060 83.400 DELETED 83.250 83.170 94 1395 83.240 83.070 83-410 DELETED 83.270 83.160 1410 83.240 83.070 83.410 DELETED 83.270 83.180 96 1425 83.250 83.080 83.410 DELETED 83.280 83-180 97 1440 83 '40 83.080 83.410 DELETED 83.280 83-150 END OF TABLE
0 VARIABLE TABLE
SUMMARY
SAMPLE DEr TA TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP 24 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 82.450 79.090 82.460 82.540 82.940 82.420 2 15 82.470 79 '30 82.480 82.560 82.950 82.440 3 30 82.500 79-140 82.520 82.590 82.980 82.460 4 45 82.520 79.170 82.530 82.620 82.990 82.500 5 60 82.560 79.200 82.560 82.650 83 '20 82.520 6 75 82.590 79.220 82.580 82.680 83.050 82.550 7 90 82 '10 79.250 82.600 82.700 83.080 82 '70 8 105 82.630 79 '80 82.630 82.730 83.090 82.600 9 120 82.650 79.280 82.660 82.730 83.100 82.600 10 135 82.670 79.310 82.670 82.760 83.120 82.640 il 12 150 165 82 '80 82.730 79.320 79-340 82.690 82.700 82.780 82.810 83.130 83.3.90 82.650 82.680 13 180 82.730 79.370 82.710 82.800 83.190 82.680 14 195 82.740 79.380 82.750 82.820 83 '10 82.690 15 210 82.760 79.400 82.780 82.840 83 '10 82.710 16 225 82.780 79.410 82.760 82.860 83.240 82.740 17 240 82.810 79-410 82.790 82.880 83.260 82.750 18 255 82.820 79.440 82.810 82.900 83.280 82.780 19 270 82.830 79-460 82.820 82.900 83.290 82.780 20 285 82.840 79-460 82.840 82.930 83.310 82.810 21 300 82.860 79.490 82.830 82.930 83 '30 82.820 22 315 82.880 79.490 82.870 82.970 83.330 82.830 23 330 82.890 79 500 82.890 82.970 83.350 82.850 24 345 82.910 79.520 82.900 82.980 83.360 82.870 25 360 82.920 79.520 82.900 82.990 83.380 82.870 26 375 82.940 79-540 82.930 83.000 83.390 82.890 27 390 82.940 79.550 82.930 83.030 83.410 82.910 28 405 82.970 79.570 82.940 83.060 83.420 82.930 29 420 82.980 79.570 82.960 83.050 83.440 82.940 30 435 83.000 79 '600 82-970 83.060 83 '50 82.940 31 450 83.000 79.610 82.980 83.070 83.470 82.960 32 465 83.010 79-610 82.990 83.080 83.480 82.970
~ 79.630 82-980 83.080 83.480 82.970 3 480 83.020 34 495 83.040 79.630 83-010 83.100 83.500 83.000 35 510 83.050 79.690 83.000 83.120 83.510 83.010 36 525 83.070 79.660 83-030 83.120 83.530 83.010 37 540 83.070 79.670 83.040 83.150 83.530 83.020 38 555 83.100 79-690 83.080 83-150 83.540 83.040 39 570 83.080 79.660 83.020 83.130 83.510 83.020 40 585 83.3.00 79-690 83.050 83.160 83.540 83.050 41 600 83.110 79.710 83.080 83.170 83.560 83.060 42 615 83.130 79.720 83.050 83.190 83.570 83.080 43 630 83.130 79.730 83-080 83.200 83.590 83.080 44 645 83.140 79.730 83.100 83.180 83.580 83.100 45 660 83 '40 79.730 83.120 83-200 83.590 83.100 46 675 83.150 79.750 83.130 83.220 83.600 83.110 47 690 83.160 79.770 83.140 83.220 83 '10 83.130 48 705 83.180 79.770 83.140 83.250 83.630 83.120 49 720 83.180 79.770 83.150 83.240 83.630 83.130 50 735 83.180 79.790 83.150 83.240 83.630 83.140
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP '4 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 83.200 79.790 83.160 83.260 83.640 83.150 52 765 83.210 79.800 83.230 83.260 83.670 83.160 53 780 83.210 79.810 83.200 83.270 83.680 83.180 54 795 83.220 79.810 83.190 83.280 83.700 83.180 55 810 83.230 79.820 83.190 83.290 83.700 83.190 56 825 83.240 79.820 83.210 83.290 83.700 83.200 57 840 83.250 79.840 83.230 83.300 83.710 83.200 58 855 83.250 79.830 83.230 83.300 83-710 83.200 59 870 83.250 79.840 83.220 83.310 83.710 83.210 60 885 83.270 79-850 83.230 83.320 83.720 83.220 61 900 83.270 79.860 83.250 83.320 83-730 83.220 62 915 83.270 79.870 83.250 83.320 83.730 83.250 63 930 83.280 79-870 83.210 83.340 83 '30 83.240 64 945 83.290 79.890 83.240 83.350 83.730 83.260 65 960 83 '90 79-880 83.240 83.360 83 '50 83.260 66 975 83.290 79.890 83 '50 83.350 83 '40 83.260 67 990 83.300 79.890 83.250 83-370 83.750 83.260 68 1005 83.300 79.890 83.240 83.360 83.750 83.260 69 1020 83.310 79.900 83.270 83 '80 83.780 83.280 70 1035 83.310 79.900 83.290 83-390 83.770 83.270 71 1050 83.310 79 '00 83.270 83.360 83.750 83.270 72 1065 83.300 79.890 83.260 83 '60 83.740 83.250 73 1080 83.310 79.900 83.270 83 '60 83.750 83.270 74 1095 83.320 79.900 83 '70 83 '60 83.750 83.280 75 lliO 83 '10 79.900 83.270 83.370 83 '50 83-280 76 1125 83.320 79.920 83-250 83.400 83,.780 83.290 77 1140 83.340 79.930 83.270 83.400 83.800 83 '20 78 1155 83.340 79.930 83.280 83.390 83.790 83.310 79 1170 83.320 79.910 83.310 83.390 83.770 83.280 80 1185 83-340 79.920 83.280 83.410 83 '90 83.300 81 1200 83.360 79.940 83.310 83-420 83.810 83.310 82 1215 83.370 79-950 83.340 83.410 83.810 83.330 83 1230 83.370 79.960 83-340 83.420 83.800 83.330 84 1245 83.330 79.920 83.290 83.390 83.770 83.300 85 1260 83-370 79.950 83.340 83.420 83.790 83.320 86 1275 83.360 79.940 83.290 83.410 83.790 83.320 87 1290 83.370 79.950 83.330 83.420 83.790 83 '20 88 1305 83 '70 79.950 83.330 83.430 83.800 83.340 89 1320 83.380 79.970 83-370 83.430 83.810 83.350 90 1335 83.380 79.970 83-340 83.430 83.800 83.340 91 1350 83.390 79.960 83.350 83.450 83.810 83.340 92 1365 83.380 79.960 83-310 83.420 83 '90 83.330 93 1380 83.390 79.980 83.350 83.430 83 810 F 83.340 94 1395 83.390 79.960 83.360 83.460 83.810 83-350 95 1410 83.410 79.980 83.390 83.460 83 '30 83.360 96 1425 83.410 79.990 83.390 83.480 83.820 83.370 97 1440 83.4iO 79.990 83.370 83.470 83.840 83.370 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEMP 30 NUMBER MINS DEG. F DEG. F . DEG. F DEG. F DEG. F DEG. F 1 0 82-580 82.450 82.470 82.900 82.250 81.770 2 15 82.600 82.460 82.500 82.900 82.260 81.800 3 30 82 '10 82-480 82.520 82.930 82.280 81.820 45 82.650 82.520 82.560 82.920 82.310 81.840 82.580 82.580 82.980 82.330 81.860 5
6 '5 60 82.670 82.720 82.590 82.600 83.020 82.360 81.900 7 90 82.720 82.610 82.630 83.040 82.380 81.910 8 105 ~
82.760 82-630 82.650 83.050 82.410 81.940 9 120 82.760 82.640 82.670 83.070 82.420 81.950 10 135 82.790 82.680 82.700 83-080 82.460 81.980 11 150 82.810 82 '80 82.710 83.110 82.490 82.000 12 165 82-840 82.720 82.750 83.140 82 '00 82.030 13 180 82.850 82.720 82.750 83.140 82.520 82.020 14 195 82-860 82-740 82.780 83.170'3.170 82.530 82.050 15 210 82.880 82.750 82.790 82.540 82.060 16 225 82.910 82.780 82.810 83.200 82.570 82.080 17 240 82.920 82-800 82.830 83-200 82.610 82.100 18 255 82.930 82.810 82.840 83.210 82.610 82.110 19 270 82.950 82.830 82.860 83.220 82.620 82.120 20 285 82.960 82-850 82-880 83.260 82.620 82.130 21 300 82.980 82-860 82.890 83.260 82.630 82 '40 22 315 82.990 82.870 82.910 83.280 82.640 82.160 23 330 83-010 82.900 82.920 83.300 82.670 82.180 24 345 83-030 82.910 82.930 83.310 82.670 82.200 25 360 83-030 82.920 82.940 83.300 82.670 82.200 26 375 83.050 82.940 82.960 83.330 82.710 82.220 27 390 83.070 82.960 82.970 83 '50 82.710 82.230 28 405 83.100 82.960 82.990 83-350 82.740 82.250 29 420 83.100 82.990 83.000 83.370 82.740 82.260 30 435 83.120 83-000 83.020 83.390 82.760 82-280 31 450 83.120 83.000 83.030 83.380 82.770 82.290 32 465 83.130 83.010 83.040 83.400 82.780 82.290 33 480 83.140 83-040 83-050 83.400 82.780 82.310 34 495 83.160 83.050 83-070 83.430 82.810 82.320 35 510 83. 170 . 83.060 83.080 83.440 82.820 82.350 36 525 83.190 83-090 83.090 83.450 82.830 82.340 37 540 83-190 83.080 83.090 83.460 82.840 82 '50 38 555 83-210 83.090 83.100 83.470 82.850 82.360 39 570 83.180 83-070 83.080 83.440 82.830 82.340 40 585 83.220 83.110 83.110 83.490 82.860 82.370 41 600 83 '40 83.120 83.130 83.490 82.880 82.390 42 61S 83.250 83.150 83.150 83.500 82.910 82.400 43 630 83.260 83.140 83.160 83 '10 82.900 82.410 44 645 83.260 83.160 83.160 83.520 82.910 82.420 45 660 83.260 83.150 83.170 83.530 82-910 82.430 46 675 83.280 83.160 83.180 83.530 82.920 82.440 47 690 83.280 83.180 ~ 83.200 83 '40 82.930 82-450 48 705 83.290 83.180 83.200 83.570 82.940 82-450 49 720 83-290 83.190 83.200 83.560 82.940 82.450 50 735 83.320 83.190 83.210 83.550 82 '40 82.450
0 YARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEMP 30 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. DEG. F 51 750 83 '20 83-200 83.220 83.570 82.960 82.470 52 765 83.340 83.230 83.220 83.580 82.960 82.480 53 780 83.340 83.250 83.220 83.580 82.950 82.480 54 795 83.350 83.260 83.240 83.590 82.970 82.490 55 810 83 '70 83.260 83.240 83 '00 82.980 82.500 56 825 83 '60 83.250 83.260 83.620 83.000 82.520 57 840 83.370 83.260 83.260 83.610 83.000 82.510 58 855 83.370 83.280 83.270 83.620 83.020 82.520 59 870 83.370 83.280 83.270 83.620 83.020 82.520 60 885 83.390 83.310 83.280 83.650 83.030 82.530 61 900 83.430 83.290 83.290 83.640 83-030 82.540 62 915 83.4'0 83.300 83.300 83.640 83.040 82.540 63 930 83.420 83.300 83.300 83.640 83 '40 82.540 64 945 83.430 83.330 83.310 83.660 83-050 82.560 65 960 83.430 83-340 83.310 83.670 83.060 82.560 66 975 83.430 83.340 83.310 83.660 83.050 82.560 67 990 83.430 83.340 83.320 83.680 83.070 82.570 68 1005 83.440 83 '50 83.320 83.670 83.070 82.570 69 1020 83.430 83.330 83.320 83.670 83.060 82.580 70 1035 83.440 83.350 83.320 83.670 83-060 82.580 71 1050 83.440 83.330 83.320 83.680 83.060 82.570 72 1065 83 '20 83.320 83.300 83.660 83-050 82.560 73 1080 83.440 83.320 83.320 83.670 83.060 82.570 74 1095 83.440 83.360 83.320 83.680 83.070 82.570 75 1110 83.450 83.370 83.320 83.670 83-070 82.580 76 1125 83.470 83.340 83.330 83-680 83.080 82.580 77 1140 83.490 83.370 83.350 83.700 83.090 82.600 78 1155 83.480 83.370 83.340 83.700 83.090 82.600 79 1170 83.460 83.360 83.330 83.700 83.080 82.590 80 1185 83.470 83.360 83-340 83.700 83.090 82-600 81 1200 83.490 83.390 83.370 83.740 83.130 82.630 82 1215 83.510 83.390 83.370 83.740 83.120 82.630 83 1230 83.490 83.380 83.360 83 '30 83.120 82.630 84 1245 83.470 83.370 83.340 83.720 83.100 82.600 85 1260 83.510 83.390 83.360 83.730 83.110 82.620 86 1275 83.490 83.390 83.360 83.720 83.110 82.620 87 1290 83.500 83.390 83.360 83.720 83-130 82.630 88 1305 83.510 83.400 83.370 83.740 83.130 82.640 89 1320 83.510 83.400 83.380 83.740 83.140 82.640 90 1335 83.510 83.420 83.390 83.740 83.140 82.640 91 1350 83.520 83.410 83.390 83 '50 83.140 82.640 92 1365 83.500 83.400 83.370 83.740 83.140 82.640 93 1380 83.520 83.430 83.390 83 '60 83.150 82.640 94 1395 83.520 83.410 83.390 83.760 83-150 82.650 95 1410 83.530 83.420 83.400 83.770 83.160 82 '60 96 1425 83.550 83.440 83 '10 83.770 83.160 82.670 97 1440 83.550 83.440 83.410 83.780 83.160 82.670 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA EMP 31 TEMP 32 TEMP 33 TEMP 34 TEMP 35 TEMP 36 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 DELETED 82.260 82.110 82.210 82.180 82.450 2 15 D"LETED 82.290 82.120 82.220 82.190 82.480 3 30 DELETED 82.320 82 '50 82.260 82.230 82.510 4 45 DELETED 82.350 82.180 82.280 82.260 82.540.
5 60 DELETED 82.360 82.200 82.310 82.280 82.550 6 75 DELETED 82.400 82.240 82.330 82.310 82.580 7 90 DELETED 82.420 82.260 82.360 82.330 82.610 8 105 DELFTED 82.450 82.270 82.370 82.350 82.630 9 120 DELETED 82.460 82.300 82.380 82.370 82-640 10 135 DELETED 82.480 82.320 82.410 82.400 82.670 11 150 DFLETED 82.500 82.340 82.430 82.420 82.690 12 165 DELETED 82.530 82.370 82.470 82.450 82.710 13 180 DELETED 82.530 82.380 82.470 82.450 82.720 14 195 DELETED 82.550 82.390 82.480 82.470 82.740 15 210 DELETED 82.560 82.400 82.490 82.480 82.750 16 225 DEr ETED 82.600 82.430 82.520 82.510 82.800 17 240 DELETED 82.610 82 '60 82.540 82.520 82.790 18 255 DELETED 82.620 82.470 82.540 82.550 82-820 19 270 DELETED 82.630 82.490 82.570 82.560 82.840 20 285 DELETED 82.660 82.500 82.580 82.580 82.850 21 300 DELETED 82.670 82.510 82.610 82.620 82.850 22 315 DELETED 82.680 82.520 82.610 82.600 82.870 23 330 DELETED 82.700 82.540 82.620 82.640 82.920 24 345 DELETED 82.710 82.560 82.630 82.640 82.910 25 360 DELETED 82.710 82.560 82.630 82.640 82.920 26 375 DELETED 82.730 82.590 82.650 82.660 82.940 27 390 DEr ETED 82 '50 82.600 82.650 82.670 82.950 28 405 DELETED 82.770 82 '10 82.670 82.680 82.970 29 420 DELETED 82.790 82.640 82 '80 82.700 82-980 30 435 DELETED 82.810 82.640 82 '90 82.710 83.000 31 450 DELETED 82.800 82.650 82-700 82.720 83 ~ 010 32 465 DELETED 82.810 82.650 82.700 82 '30 83.020 33 480 DELETED 82.810 82.670 82.710 82.740 83.020 34 495 DELETED 82.830 82.680 82 '30 82.780 83 '40 35 510 DELETED 82.850 82.700 82 '40 82-790 83.050 36 525 DELETED 82.850 82.700 82.740 82 '80 83-050 37 540 DELETED 82.860 82.710 82.750 82.790 83-070 38 555 DELETED 82.880 82.740 82.760 82.810 83.080 39 570 DELETED 82.860 82.700 82.780 82.780 83.050 40 585 DELET"D 82.900 82.740 82.790 82.820 83.100 41 600 DELETED 82.910 82.750 82.790 82.860 83.110 42 615 DELETED 82.920 82.770 82.810 82.850 83.120 4~ 630 DELETED 82.930 82.780 82.810 82.860 83.140 44 645 DELETED 82.920 82.780 82.820 82.900 83.140 45 660 DELETED 82.930 82.790 82.820 82.880 83.140 46 675 DELETED 82.940 82.800 82.830 82.970 83.150 47 690 DELETED 82.950 82.820 82.850 82.890 83.160 48 705 DELETED 82.960 82.820 82.850 82.910 83.170 49 720 DELETED 82.960 82.830 82.850 82.890 83.160 50 735 DELETED 83.000 82-840 82.870 82.910 83.190
VARIABLE TABLE SUMYiARY (CONTINUED)
SAMPLE DELTA TEMP 31 TEYiP 32 TEMP 33 TEYiP 34 TEMiP 35 TEMP 36 NUMBER MENS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 DELETED 82.990 82.840 82.880 82.920 83.190 52 765 DELETED 82.990 82.850 82.890 82.930 83.210 53 780 DELETED 82.990 82.850 82.900 82.930 83.190 54 795 DELETED 83.000 82 '60 82.910 82.940 83.190 55 810 DELETED 83.020 82.870 82.900 82.940 83.210 56 825 DELETED 83.020 82.830 82.920 82.960 83.230 57 840 DELETED 83.030 82.880 82.920 82.960 83.230 58 855 DELETED 83.030 82.890 82.930 83.030 83.240 59 870 DELETED 83.020 82.890 82.920 82.970 83.230 60 885 DELETED 83.040 82.910 82.940 82.980 83.250 61 900 DELETED 83.050 82.910 82.950 82.980 83.240 62 915 . DELETED 83.060 82.920 82.950 82.990 83.260 63 930 DELETED 83.060 82.920 82.950 82.990 83.260 64 945 DELFTED 83.060 82-930 82.980 83.000 83.290 65 960 DELETED 83.070 82.930 83.020 83.000 83.280 66 975 DELETED 83.070 82.930 82.980 83.000 83.270 67 990 DELETED 83.070 82.940 82.980 83.010 83.290 68 1005 DELETED 83.080 82.940 82.990 83.010 83.290 69 1020 DELETED 83.080 82.950 82.980 83.030 83.300 70 1035 DELETED 83.090 82.940 82.970 83.030 83.290 71 1050 DELETED 83 080
~ 82.940, ,82.970 83.020 83.290 72 1065 DELETED 83.070 82.930 82.960 83.010 83.280 73 1080 DELETED 83.080 82.930 82.960 83.020 83.290 74 1095 DELETED 83.090 82.940 82.980 83.030 83.290 75 1110 DELETED 83.090 82.950 82.750 83.020 83.300 76 1125 DEi ETED 83.100 , 82.950 82.760 83.030 83.300 77 1140 DELFTED 83.110 82.970 82.840 83.050 83.320 78 1155 DELETED 83.110 82.960 82.850 83.030 83.300 79 1170 DELETED 83.100 82.960 82.820 83.030 83.290 80 1185 DELETED 83.110 82.960 82.850 83.040 83.310 81 1200 DELETED 83.140 82.990 82.900 83.070 83.340 82 1215 DELETED 83.130 82.990 82.900 83.070 83.330 83 1230 DELETED 83.130 82.980 82.910 83.060 83.320 84 1245 DELETED 83. 120 82.960 82.900 83.040 83.310 85 1260 DELETED 83.130 82.990 82.920 83.060 83.320 86 1275 DELETED 83.130 82.980 82.930 83.060 83.320 87 1290 DELETED 83.120 82.980 82.940 83.060 83.330 88 1305 DELETED 83.140 83.000 82.960 83.070 83.350 89 1320 DELETED 83.140 83-010 82.970 83.090 83-340 90 1335 DELETED 83 150
~ 83.010 82.980 83.070 83-340 91 1350 DELETED 83.150 83.010 82.990 83.090 83.340 92 1365 DELETED 83.130 82.990 82.970 83.070 83.330 93 1380 DELETED 83.140 83.010 82.990 83.080 83.360 94 1395 DELETED 83.160 83 '20 83.010 83.100 83.370 95 1410 DELETED 83.160 83 '20 83.010 83 110 F 83.370 96 1425 DELETED 83 '70 83 '40 83.030 83.110 83.380 97 1440 DELETED 83.170 83.030 83.030 83.100 83-360 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 37 TEMP 38 TEMP 39 TEMP 40 PRES 1 HUM 1 NUMBER MINS DEG- F DEG. F DEG. F DEG. F PSIA FRACTION 1 0 82.190 82 '60 81.850 82.120 38.042 0.686 2 15 82.220 82.640 81.880 82.130 38.044 0.686 3 30 82.230 82.690 81.900 82.150 38.045 0. 686 4 45 82 '70 82.730 81.940 82.190 38.048 0.686 5 60 82.350 82.760 81.950 82.210 38.050 0. 686 6 75 82.330 82.780 81.990 82.240 38.052 0-685 7 90 82.360 82.810 82.010 82.270 38.053 0 '85 8 105 82.370 82.800 82 040 F 82.290 38.055 0.685 9 120 82.380 82.880 82.050 82-300 38.057 0.685 10 135 82.410 82.840 82.080 82.330 38.059 0.685 11 150 82.450 82.870 82.100 82.350 38.060 0.685 12 165 82.460 82.890 82.130 82.380 38.062 0.685 13 180 82.460 82.910 82.140 82.390 38.063 0.685 14 195 82.470 82.920 82.160 82 '20 38.064 0.685 15 210 82.500 82.950 82.180 82.430 38 '66 0.685 16 225 82.560 83.030 82.200 82.460 38.067 0.685 17 240 82.550 82.970 82.220 82.460 38.069 0.685 18 255 82.560 82.970 82.230 82.480 38.069 0-685 19 270 82 600 F 83.000 82.250 82.500 38.071 0.685 20 285 82.600 83.070 82.260 82.510 38.073 0.685 21 300 82-620 83.010 82.280 82.520 38.074 0 ~ 685 22 315 82.620 83.030 82.290 82.550 38.075 0.684 23 330 82.660 83.070 82.310 82.570 38.076 0.685 24 345 82.670 83.060 82.320 82.590 38.077 0.685 25 360 82.660 83.260 82.320 82.600 38.078 0.685 26 375 82-700 83.090 82.330 82.620 38.079 0.685 27 390 82.750 83.110 82.370 82.630 38.080 0.685 28 405 82-720 83.110 82.380 82.640 38.081 0.685 29 420 82.730 83.130 82.390 82.660 38.083 0.685 30 435 82 '30 83.150 82.400 82.680 38.084 0.685 31 450 82.750 83.150 82.410 82.700 38.085 0.685 32 465 82.780 83.160 82.430 82.710 38.086 0.685 33 480 82.770 83.170 82.420 82.700 38.087 0.685 34 495 82-790 83.190 82.450 82.730 38.088 0.684 35 510 82.810 83.210 82.460 82.740 38.089 0.684 36 525 82 810 F 83.220 82.490 82.750 38.090 0.684 37 540 82.820 83.240 82.490 82.770 38.091 0.685 38 555 82.830 83-240 82.510 82.790 38.092 0.684 39 570 82.800 83.210 82.480 82.750 38.093 0-684 40 585 82.850 83.250 82.520 82.790 38.094 0.684 43: 600 82.870 83.270 82.540 82.810 38.094 0-684 42 615 82 '70 83.280 82.550 82.830 38.095 0.685 43 630 82.860 83.290 82.530 82.820 38.096 0.685 44 645 82.880 83.300 82.560 82.830 38.097 0.684 45 660 82.870 83.310 82.560 82.850 38.097 0 ~ 685 46 675 82-900 83.290 82.590 82.860 38.098 0.685 47 690 82.910 83.330 82.600 82.870 38.099 0.685 48 705 82 '10 83.370 82.590 82.890 38.099 0.685 49 720 82.920 83.320 82.610 82.880 38.106 0.685 50 735 82 '20 83.320 82.600 82.880 38.100 0.685
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAHPLE DELTA TEMP 37 TEMP 38 TEMP 39 TEMP 40 PRES 1 HUH 1 NUMBER HINS DEG. F D"G. F DEG. F DEG. F PSIA FRACTION 51 750 82.930 83.340 82.620 82.900 38.102 0.685 52 765 ,82.930 83.420 82.630 82.900 38.102 0.685 53 780 82.920 83.380 82.620 82.900 38.102 0.685 54 795 82.930 83.390 82.640 82.910 38.103 0.685 55 810 82.950 83.370 82.650 82.910 38.104 0-685 56 825 82.970 83.330 82.660 82.930 38.104 0.685 57 840 82.970 83.400 82.660 82.930 38 '05 0 ~ 685 58 855 82.960 83.420 82.660 82.940 38.105 . 0.685 59 870 82.940 83.410 82.670 82.940 38.106 0.685 60 885 82.970 83.350 82.670 82.960 38.107 0.686 61 900 82.970 83.530 82 '90 82.960 38.108 0.686 62 915 82.970 83.420 82.690 82.960 38.108 0.686 63 930 82.970 83.380 82.690 82.970 38.108 0 ~ 686 64 945 83.010 83.430 82 '00 82.970 38.109 0.686 65 960 82.990 83.430 82.790 82.980 38.110 0. 686 66 975 83.010 83.440 82.590 82.970 38.110 0.686 67 990 83.000 83.470 82.690 82.980 38.111 0.686 68 1005 83.020 83.460 82-710 82.980 38.111 0.686 69 1020 83.030 83.400 82.700 82.980 38.111 0.686 70 1035 83.030 83.510 82.710 82.980 38.112 0.686 71 1050 83-030 83-540 82.710 82.980 38.112 0.686 72 1065 83.000 83.520 82 '00 82.980 38-113 0.686 73 1080 83 '30 83.430 82.710 82.980 38.113 0.686 74 1095 83.030 83-460 82.720 82.980 38.113 0.687 75 1110 83.030 83.450 82.720 82.980 38.114 0.687 76 1125 83.020 83.500 82.710 82.990 38.114 0.687 77 1140 83.050 83.530 82.740 83.010 38."115 0.687 78 1155 83.050 83.470 82.730 83-000 38.3.15 0.687 79 1170 83.050 83.470 82.730 82.980 38-115 0.687 80 1185 83.060 83.530 82.730 83.000 38.116 0.687 81 1200 83.080 83.510 82.750 83.020 38.116 0.687 82 1215 83.080 83-490 82.760 83.010 38.117 0.687 83 1230 83.070 83.500 82.750 83.000 38.117 0.687 84 1245 83.040 83.490 82.720 83.000 38.117 0.688 85 1260 83.070 83-530 82.750 83.010 38.117 0.688 86 1275 83.080 83.480 82.750 83.010 38.118 0.688 87 1290 83.060 83.530 82.750 82.990 38.118 0.688 88 1305 83-080 83.500 82.760 83.020 38.119 0.688 89 1320 83.080 83.500 82.780 83.030 38.119 0.688 90 1335 83.070 83 '20 82.760 83.040 38.119 0.688 91 1350 83.090 83.520 82.770 83.030 38.120 0.688 92 1365 83.080 83.510 82.760 83.010 38.120 0.688 93 1380 83-070 83.500 82.770 83.040 38.120 0.688 94 1395 83.090 83.540 82.770 83.040 38.120 0.688 95 1410 83.090 83.530 82.770 83.050 38.121 0.688 q6 1425 83.100 83.580 82.800 83.050 38.121 0.688 97 1440 83.110 83.550 82.780 83.060 38.121 0.689 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUYi 2 HUM 3 HUM 4 HUM 5 HUYi 6 7 NUMBER MINS FRACTION FRACTION FRACTION FRACTION FRACTIOh'UMFRACTIOh' 0 DELETED 0.702 0.683 0.694 0.692 0.683 2 15 DELETED 0.701 0.683 0.694 0.692 0.683 3 30 DELETED 0.701 0.683 0.693 0.692 0 '83 45 DELETED 0.701 0.683 0.693 0.692 0.682 5 60 DELETED 0.701 0.683 0.693 0.692 0.682 6 75 DELETED 0.701 0.683 0.694 0.692 0.682 7 90 DELETED 0.701 0.683 0.694 0.692 0.682 8 105 DELETED 0.701 0.683 0.694 0.692 0.682 9 120 DELETED 0.701 0.683 0.693 0.691 0.683 lo 135 DELETED 0.701 0.683 0.693 0.691 0.682 ll 12 150 165 DELETED DELETED 0.701 0.701 0 '83 0.683 0.693 0.694 0.692 0.691 0.682 0.682 13 180 DELETED 0.701 0.683 0.693 0.691 0.682 14 195 DELETED 0.701 0.683 0.694 0.691 0.682 15 210 DELETED 0.701 0.683 0.693 0.691 0.682 16 225 DELETED 0.701 0.682 0.693 0.691 0.682 17 240 DELETED 0.701 0.683 0.694 0.691 0 '83 18 255 DELETED 0.701 0.683 0.694 0.691 0.682 19 270 DELETED 0.701 0.683 0.693 0-691 0.682 20 285 DELETED 0.701 0.682 0.694 0.691 0.682 21 300 DELETED 0.701 0.683 0.693 0.691 0.682
'22 315 DELETED 0-701 0.683 0.693 0.691 0 '82 23 330 DELETED 0.701 0-682 0.694 0.691 0.682 24 345 DELETED 0.701 0.683 0.693 0-692 0.682 25 360 DELETED 0.701 0.683 0.693 0.691 0.682 26 375 DELETED 0.701 0-683 0.693 0.691 0.682 27 390 DELETED 0.701 0.683 0.694 0.691 0.682 28 405 DELETED 0.701 0.683 0.693 0.691 0.682 29 420 DELETED 0.702 0.683 0.693 0.691 0.682 30 435 DELETED 0.702 0.683 0.694 0-691 0.682 31 450 DELETED 0.702 0.683 0.694 0.691 0.682 32 465 DELETED 0.702 0.683 0.694 0.691 0.682 33 480 DELETED 0.701 0 '83 0.694 0.691 0.682 34 495 DELETED 0.701 0.683 0.694 0.691 0.682 35 510 DELETED 0.701 0 '83 0.694 0 '91 0.682 36 525 DELETED 0.701 0-683 0.694 0.691 0.682 37 540 DELETED 0.701 0.683 0.694 0.691 0.682 38 555 DELETED 0.701 0.683 0.694 0.691 0.682 39 570 DELETED 0.701 0.683 0.695 0.691 0.682 40 585 DELETED 0.702 0.683 0.694 0.690 0.682 41 600 DELETED 0.702 0.682 0.694 0.691 0-682 42 615 DELETED 0.701 0.682 0.694 0.691 0.682 43 630 DELETED 0.702 0.682 0.694 0.691 0.682 44 645 DELETED 0.702 0.682 0.694 0.691 0.683 45 660 DELETED 0.702 0.682 0.695 0.691 0.682 46 675 DELETED 0.702 0 '82 0.694 0.691 0.683 47 690 DELETED 0.702 0.682 0.694 0.691 0.682 48 705 DELETED 0.702 0.683 0.694 0.691 0.683 49 720 DELETED 0.702 0.683 0.694 0.691 0.683 50 735 DELETED 0.702 0.683 0.695 0.691 0.683
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA HUM 2 HUMi 3 HUM 4 HUM 5 HUM 6 HUM 7 NUMBER MiINS FRACTION FRACTION FRACTION FRACTION FRACTION FRACTION 51 750 DELETED 0.702. 0 '83 0.695 0-691 0.683 52 765 DELETED 0.702 0.683 0.695 0.691 0-683 53 780 DELETED 0.702 0.683 0.695 0.691 0.683 54 795 DELETED 0.703 0 '83 0.695 0.691 0.683 55 810 DELETED 0.703 0.683 0-695 0.691 0.683 55 825 DELETED 0.702 0.683 0 '95 0.691 0.683 57 840 DELETED 0.702 0.683 0.696 0.691 0.683 58 855 DELETED 0.703 0.683 0-695 0.691 0.683 59 870 D r ETED 0.703 0 '83 0-696 0.691 0.683 60 885 DELETED 0.703 0 '83 0.696 0.691 0.684 61 900 DELETED 0.703 0 '83 0.695 0.692 0.684 62 915 DELETED 0.702 0.683 0.695 0.692 0-684 63 930 D"LETED 0.702 0 '83 0 '96 0.691 0.683 64 945 DEL"TED 0.702 0 '83 0.696 0.692 0.684 65 960 DELETFD 0.703 0.683 0.696 0.692 0.684 66 975 DELETED 0.703 0 '83 0.696 0 '92 0.684 67 990 D"LETED 0.703 0.683 0.696 0.692 0.684 68 1005 DELETED 0.703 0.683 0.697 0.692 0.684 69 1020 DELETED 0 '03 0.683 0.697 0.692 0.684 70 1035 DELETED 0.703 0.683 0.697 0.692 0.684 71 1050 DELETFD 0.703 0-684 0.696 0.692 0.685 72 1065 DELETED 0.703 0.684 0 '96 0.692 0.685 73 1080 DELETED 0.703 0.684 0.696 0.692 0.685 74 1095 DELETED 0.703 0 '84 0.697 0.692 0.685 7P ljlo DELETED 0.703 0.684 0.697 0.692 0.684 76 1125 DELETED 0.703 0-684, 0.697 0.692 0.685 77 1140 DELETED 0.703 0.685 0-697 0.692 0.685 78 1155 DELETED 0.703 0.684 0.697 0.691 0.685 79 1170 DELETED 0.703 0.685 0.698 0.692 0.685 80 1185 DELETED 0.703 0.684 0.698 0 '93 0.685 81 1200 DELETED 0.704 0-685 0.697 0.692 0.685 82 1215 DELETED 0.704 0.685 0 '97 0.692 0.685 83 1230 DELETED 0.704 0.685 0 '97 0.692 0.685 84 1245 DELETED 0.704 0-685 0 '97 0.693 0.686 85 1260 DELETED 0.704 0.685 0.697 0.693 0.686 86 1275 DE'TED 0.704 0.685 0.698 0.693 0.686 87 1290 DELETED 0.704 0-685 0.698 0.693 0.686 88 1305 DELETED 0.704 0.685 0.698 0.693 0.686 89 1320 DELETED 0.704 0.685 0.698 0.693 0.686 90 1335 DELETED 0.704 0.685 0.699 0.693 0.686 91 1350 DELETED 0.704 0.685 0-699 0.693 0.687 92 1365 DELETED 0.705 0.685 0.699 0.693 0.686 93 1380 DELETED 0.705 0-686 0.699 0 '93 0.686 94 1395 DELETED 0.705 0 '86 0.699 0.693 0.687 95 1410 DELETED 0.705 0 '86 0.699 0.693 0.687 96 1425 DELETED 0.705 0.686 0.698 0.693 0.687 97 1440 DELETED 0.705 0 '86 0.699 0.692 0.687 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 8 HUM 9 HUM ip NUMBER MINS FRACTION FRACTION FRACTION 1 0 0.701 0.711 0.701 2 15 0.700 0.711 0.701 3 30 0.700 0.710 0.701 45 0.700 0.710 0.700 5 60 0.700 0.710 0.701 6 75 0.700 0.710 0.700 7 90 0.700 0.710 0.700 8 105 0.700 0.710 0.701 9 120 0 '00 0.710 0.700 10 135 0.700 0.710 0.700 ll 12 150 165 0.700 0.700 0.710 0.710 0.700 0.700 13 180 0.699 0.710 0.700 14 195 0.700 0.710 0.700 15 210 0.699 0.710 0.700 16 225 0.700 0.710 0-700 17 240 0-699 0.710 0.700 18 255 0-699 0.710 0.700 19 270 0.699 0 '09 0.700 20 285 0.699 0.710 0 '00 21 300 0.699 0.709 0.700 22 315 0 '99 0.710 0.700 23 330 0.699 0.710 0.700 Pi 4 345 0.699 0.709 0.700 25 360 0.699 0.710 0.700 26 375 0.700 0.709 0.700 27 390 0.699 0.710 0.700 28 405 0.699 0. 710'.710 0.700 29 420 0-699 0.700 30 435 0-699 0.710 0.700 31 450 0-699 0.710 0.700 32 465 0.700 0.710 0.700 33 480 0.699 0.710 0.700 34 495 0.700 0.710 0.700 35 510 0.699 0.710 0.700 36 525 0.699 0.710 0 ~ 700 37 540 0.700 0.710 0.700 38 555 0.700 0.710 0.701 39 570 0.700 0.710 0.700 40 585 0.701 0.710 0.700 41 600 0.701 0.711 0.701 42 615 0.701 0.711 0.701 43 630 0.701 0.711 0.700 44 645 0.702 0. 711 0.700 45 660 0.701 0.711 0.701 46 675 0.701 0. 73;1 0.701 47 690 0.701 0.711 0.701 48 705 0.701 0.711 0.701 49 720 0.701 0.711 0.701 50 735 0.702 0.711 0.701
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA UM 8 HUM 9 HUM 10 NUMBER MINS RACTION FRACTION , FRACTION 51 750 0.702 0.711 0.701 52 765 0.702 0.711 0.701 53 780 0.702 0.711 0.701 "54 795 0 '02 0.711 0.701 55 810 0.702 0.712 0.701 56 825 0.702 0.712 0.701 57 840 0.702 0.712 0.701 58 855 0.703 0.712 0.702 59 870 0-703 0.712 0.701 60 885 0.703 0.712 0.702
, 61 900 0.702 0.712 0.702 62 915 0.702 0.712 0.702 63 930 0-702 0.712 0.702 64 945 0.702 0.712 0.702 65 960 0.702 0.712 0.702 66 975 0.702 0 '12 0.702 67 990 0-703 0.712 0.702 68 1005 0.703 0.712 0.702 69 1020 0.702 0.712 0.703 70 1035 0.702 0.713 0.702 71 1050 0.703 0.712 0.702 72 1065 0 '03 0.713 0.703 73 1080 0.703 0.713 0.703 74 1095 0.703 0.713 0.703 75 1110 0.703 0.713 0.703 76 1125 0.703 0.713 0.703 77 1140 0.703 0.713 0.703 78 1155 0.704 0.713 0.703 79 1170 0.703 0.713 0.703 80 1185 0.703 0.713 0.703 81 1200 0.703 0.713 0.703 82 1215 0.704 0.713 0.703 83 1230 0.704 0.713 0.703 84 1245 0.704 0.714 0.704 85 1260 0.703 0.714 0.704 86 1275 0.704 0.714 0.704 87 1290 0.704 0.714 0.704 88 1305 0 '04 0.714 0.704 89 1320 0.704 0.714 0.704 90 1335 0.704 0.714 0.704 91 1350 0.705 0.714 0.704 92 1365 0.705 0.714 0.704 93 1380 0.704 0.714 0.704 94 1395 0.705 0.714 0.705 95 1410 0.704 0.715 0.705 96 1425 0.705 0.715 0.705 ej 97 1440 0.705 0.715 0-705 END OF TABLE
469040.
17 ~ 33 ~
CONTRINNENT AIR NRSSES Bra vRSs 6S ~ 81 '7 13 c
~
F ITTEO RIR NRSS 04 cv X
IC 468960. 4 CQ al I
Cl IL Ck 5
I5 468880.
lal CS al ch
~4 CZ C) 468800. 8 6 EE 6 g UJ 468720.
468640.
240. 480. 720. 960. 1200. 1440. 1680.
TINE IN MINUTES
I 17 ~ 33 ~ 97 113.
0.1200 COMPUTED LERK RRTES ol SIMPLE HRSS POINT LERK RATE FITTEO HASS POINT LEAK RATE Q K
I I
a 0- CC CL n 5 CI CJ 0.0400 Cl kal Cl ss a
8Q@ 8
~~) a o.oooo
-0.0400 0800 1440.
240 ~ 480. 720. 960. 1200 1680 ~
TINE IN NINUTES
0.9000 7 ~ 33 ~
COMPUTED LERK RRTES 65 RELRTIVE
'1 '7 FITTED tiRSS POINT LEAK RRTE TO LIMITS 113.
c 95% CONF IDENCE L IHI T ( UCL ) CV Ol DESIGN BASIS LERKRGE RRTE NRC NRXINUN ALLOWABLE LEAKAGE RATE K EC s
0.7000 CC 4
OC ssl I
o 0- CJ n
0.5000 O.3OOO 0 1000
-0.1000 0 ~ 240. 480. 720. 960. 1200. 144Q. 168Q.
TINE IN MINUTES
7 ~ 33 ' ~ 6S. 81 97 13 s4.oooo VOLUMETR I CRLLY NEI BHTEO CONTR INMENT TEMPERRTURE QJ UJ 83.6000 CC
~4 CC 5
C) tJ 83.2000 a.
ID lal C) sl O
~4 82.8000 UJ CL CE UJ 82.4000 CL 1JJ l.
82.0000 240. 480. 720. 960. 1200 1440. 1680 TINE IN MINUTE5
I 0
f.s
38.2000 7 ~ 33 ~ 65 ~
RVERRBE CONTRINNENT PRESSURE 81 '7 113.
EV (Z 04 o
(Q K Ct' Q
38.1600 CL'al I
O CJ
%4 0
EL I5 38.1200 lal CO W
a EC 38.0800 C3 38 0400 38 0000 240 '80. 720. 960. 1200. 1440. 1680.
TINE IN NINUTES
0 0
7 ~ 33 ~ 65 ~ 81 97 13 ~
0 4120 VQLUNETR I CRLLY HEI BHTEO VRPQR PRESSURE C4 CI~
CN Ig 0.4040
>>I I
NC7
~4 I
z~
,I 0.3960
'W a
0.3880 5 II 1l 0.3800 0.3720 4 240. 480. 720. 960. 1200. 1440. 1680.
TINE IN NINUTES
FLORZDA POWER 8 LIGHT COMPANY
,ST LUCIE PLANT UNIT NO. 2 CONTAINMENT INTEGRATED LEAKAGE RATE TEST SUPPLEMENTAL VERIFICATION TEST LEAKAGE RATE MEASURED USING THE ABSOLUTE METHOD LEAKAGE RATE COMPUTED USING THE YiASS POINT METHOD TEST PERIOD STARTED AT 45 HOURS ON NOVEMBER 29, 1982 TEST CONDUCTED FOR 4.25 HOURS FREE SPACE VOLUME OF CONTAINMENT IS 2500000 CU FT CONTAINMENT WAS PRESSURIZED TO 38.12 PSIA INITIAL VERIFICATION AIR WEIGHT 468923.0 LBS FINAL VERIFICATION AIR WEIGHT 468720.0 LBS FITTED MASS POINT LEAKAGE RATE IS 0 '60 +o PER DAY LC = 0.260 LAM = .010 LO = 0-251 LO + LAM - 0 '5 LA < LC < LO + LAYi + 0-25 LA 0.251 + -.010 - 0.089 < 0.260 0.251 + -.010 + 0.089 0.153 < 0.260 0 330 LC =FITTED CLRT MASS POINT LEAKAGE RATE LAM =FITTED ILRT MASS POINT LEAKAGE RATE LO =SUPERIMPOSED LEAKAGE DURING VERIFICATION TEST LA =NRC MAXIYiUYi ALLOWABLE LEAKAGE RATE
DESCRIPTION OF VARIABLES AVG. TEM CONTAINMENT MEAN TEMPERATURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RTD SENSOR INDICATIONS.
AVF. PRE- PRIMARY CONTAINMENT PRESSURE INDICATION.
VAP. PRE CONTAINMENT VAPOR PRESSURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RHD SENSOR INDICATIONS.
LEAK SIM- SIMPLE TOTAL TIME LEAKAGE RATE.
LEAK MAS LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MASS DATA.
AIR MASS CONTAINMENT AIR MiASS.
NOTE FOR TABULAR DATA TABLE VALUES OF ZERO SIGNIFY EITHER.
- 1. DATA IS NOT APPLICABLE TO THE CALCULATION OR
- 2. SENSOR, HAS BEEN DELETED FROMi THE SCAN.
NOTE FOR CURVES
- 1. TOP ABSCISSA SCALE REPRESENTS SAMPLE NUMBERS.
- 2. AIR MASS IS THE CALCULATED CONTAINMENT AIR MASS AND FITTED AIR MASS IS THE LINEAR LEAST SQUARE F1T OF THE AIR MASSES.
- 3. SIMPLE MASS POINT IS THE TOTAL TIME LEAKAGE RATE AND FITTED MASS POINT IS THE LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MASS DATA.
- 4. UCL IS THE UPPER LIMIT OF THE 95%
CONFiDENCE LEVEL OF AIR MASS DATA.
VARIABLE TABLE
SUMMARY
SAMPLE DELTA AVG. TEM AVG. PRE VAP. PRE LEAK SIM LEAK MAS AIR MASS NUMBER MINS DEG. F PSIA PSIA PER CENT PER CENT POUNDS 1 0 83.158 38.1190 0.3932 0.000 0.000 468923 2 15 83-154 38.1180 0.3932 0.185 0.000 468914 3 30 83.154 . 38.1170 0.3932 0.219 0.219 468902 45 83.160 38.1170 0.3933 0.192 0.198 468895 5 60 83.161 38.1160 0.3934 0.217 0.213 468881 6 75 83.165 38.1150 0-3935 0.245 0.238 468863 7 90 ~ 83.171 38.1150 0.3937 0.230 0.238 468856 8 105 83.171 38.1140 .0-3936 0.232 0.238 468844 9 120 83.173 38.1130 0.3938 0.242 0.243 468828 10 135 83.182 38.1120 0.3939 0.266 0.258 468806 ll 12 150 165 83.182 83.183 38.1120 38.1110 0.3940 0.3941 0.242 0.245 0.255 0.254 468805 468791 1 3 180 83.185 38.1100 0.3941 0.249 0.255 468777 14 195 83.192 38.1100 0.3943 0.244 0.254 468768 15 210 83.200 38.1090 0.3944 0.256 0.257 468748 16 225 83.201 38.1080 0.3944 0.259 0.259 468734 17 240 83.205 38.1070 0.3946 0.265 0.263 468716 18 255 83.201 38.1070 0.3945 0.244 0.260 468720 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 1 TEYiP 2 TEYiP 3 TEMP 4 TEYiP 5 TEMP 6 NUYiBER YiINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 83.520 82.990 83.500 83.060 82.970 82.830 2 15 83.520 83.030 83.500 83-050 82.950 82.830 3 30 83 '20 82.990 83.500 83.050 82.950 82.830 4 45 83 '20 82.990'2.990 83.500 83.060 82 '40 82.840 60 83.520 83.500 83.050 82.940 '82.840 6 75 83.530 83.000 83.510 83.060 82.940 82.840 7 90 83.540 83 ~ 010 83.510 83-060 82.940 82.840 8 105 83.530 83.000 83.510 83-060 82.940 82.850 9 120 83.540 83.000 83.510 83-060 82.940 82.850 10 135 83.540 83.010 83-520 83-070 82.950 82.860 ll 12 150 165 83.540 83.540 83.020 83-010 83.520 83.520 83.070 83.070 82.940 82.940 82.860 82.860 13 180 83 '40 83.020 83.520 83.080 82.940 82.860 14 195 83.550 83.050 83.520 83.080 82.930 82.870 15 210 83.560 83-030 83.540 83-100 82.940 82.880 16 225 83.560 83-040 83.540 83.090 82.920 82-880 17 240 83 '30 83-050 83-540 83.090 82.930 82.880 18 255 83'550 83.050 83-540 83-100 82.920 82.880 END OF TABLE
VAR1ABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 7 TEMP 8 TEMP 9 TEMP 10 TEMP ll TEMP 12 NUMBER MINS DEG. r DEG. F DEG- F DEG. F DEG. F DEG. F 1' 0 83.540 83 '70 82.850 83.140 82.990 80-890 15 83.530 83.170 82.850 83.150 82.990 80 '90 3 30 83 '30 83.170 82.840 83.140 82.990 80 '90 4 45 83.540 83.160 82.850 83.150 82.990 80.900 60 83.540 83.170 82.850 83.140 82.990 80.900 6 75 83.540 83.170 82.850 83.150 83.010 80.900 7 90 83.550 83.170 82.860 83.160 83.010 80.910 8 10S 83.550 83.180 82.870 83.160 83.020 80.910 9 120 83.550 83.180 82.870 83.160 82.990 80.910 10 135 83.560 83.180 82.870 83.180 83.020 80.920 ll 12 150 165 83.560 83.560 83.190 83.180 82.870 82.890 83.190 83.180 83.020 83.010 80.910 80.920 13 180 83 '60 83.180 82.880 83.190 83.020 80.930 14 195 83.560 83.190 82.890 83.180 83.030 80.930 15 210 83 '80 83.200 82.900 83.170 83.030 80.950 16 225 83.570 83.200 82.910 83.190 83.040 80.940 17 240 83 '80 83-200 82.910 83.180 83.050 80 '40 18 255 83 '70 83.200 82.910 83.190 83 '40 80.940 END OF TABLE
r Qi VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 13 TEMP 14 TEMP 15 TEMP 16 TEMP 17 TEMP 18 NUMBER MiNS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 83.100 82.940 83.280 DELETED 83.130 83.030 2 15 83.110 82.940 83-270 DELETED 83.140 83.040 3 30 83.110 82.940 83-270 DELETED 83.140 83.040 45 83.120 82.950 83.280 DELETED 83.150 83.040 5 60 83.110 82 '50 83-270 DELETED 83.140 83.040 6 75 83 110 F 82.960 83.280 DELETED 83.150 83.050 7 90 83.120 82.970 83.290 DELETED 83.160 83 '50 8 105 83.130 82.970 83.,290 DELETED 83.150 83.050 9 120 83.120 82.970 83.300 DELETED 83.160 83-060 10 135 83.130 82.970 83.300 DELETED 83.170 83.060 11 150 83.140 82.970 83.300 DELETED 83.160 83.060 12 165 83.140 82.980 83.310 DELETED 83.160 83.070 13 180 83.140 82.980 83.300 DELETED 83.170 83.070 14 195 83.140 82.980 83.310 DELETED 83.170 83.080 10 210 83.160 82.990 83.330 DELETED 83.200 83.090 16 225 83.150 82.990 83.320 DELETED 83.200 83.090 17 240 83 '50 83.000 83.330 DELETED 83.210 03.100 18 255 83.160 82.990 83.340 DELETED 83.200 83.090 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP 24 NUMBER HINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 83.270 79.850 83.230 83.320 83.710 83.230 2 15 83.270 79.840 83-230 83.330 83.690 83.210 3 30 83.270 79 '40 83.230 83.320 83.690 83.210 4 45 83.280 79.850 83.250 83.340 83 '90 83.230 5 60 83.270 79.850 83.240 83 '30 83.700 83.230 6 75 83.290 79.850 83.240 83.340 83.700 83.220 7 90 83.280 79.870 83 '50 83.340 83.700 83.240 8 105 83-280 79.860 83.230 83-340 83.710 83.230 9 120 83.290 79.860 83.260 83.340 83.710 83.250 10 135 83.300 79.860 83.280 83.350 83 '20 83.250 ll 12 150 165 83.300 83.300 79.870 79.870 83.260 83.240 83.360 83.350 83.720 83.720 83.260 83.250 13 180 83.300 79.870 83.270 83.350 83.720 83.260 14 195 83 '10 79.880 83.300 83.350 83.730 83.260 15 210 83.320 79.890 83.280 83.360 83.740 83.270 16 225 83.310 79.890 83.280 83.350 83.750 83.270 17 240 83.320 79.880 83.270 83.390 83-750 83.280 18 255 83.320 79.890 83.230 83.380 83.750 83.280 END OF TABLE
VARIABLE'ABLE
SUMMARY
SAMPLE DELTA TEMP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEMP 30 NUMBER MENS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 83.410 83.290 83.270 83.630 83.020 82.530 2 15 83.390 83-280 83.260 83.630 83.000 82.520 3 Qp 83.390 83.290 83.260 83.630 83.020 82.520 4, 45 83.400 83.290 83.270 83.630 83.020 82.520 5 60 83 '00 83.320 83.260 83.640 83.020 82.530 6 75 83.400 83.340 83.260 83.640 83.020 82.530 7 90 83.410 83.310 83.270 83.650 83.030 82.540 8 105 83.420 83.330 83.270 83.640 83.030 82.540 9 120 83.410 83.330 83.260 83.550 83.040 82.540 10 135 83.420 83.320 83.280 83.660 83.040 82.550 11 150 83.420 83.350 83.280 83.660 83.040 82.560 12 165 83.420 83.350 83.280 83.660 83.050 82.560 13 180 83.430 83.340 83.290 83.660 83.050 82.560 14 195 83.430 83.320 83.290 83.670 83.060 82.570 15 210 83.440 83.330 83.300 83 '70 83.080 82.570 16 225 83.440 83.370 83.300 83.680 83-060 82.570 17 240 83.450 83.350 83.310 83.680 83.070 82.570 18 255 83.440 83.340 83.300 83.680 83.050 82.570 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 31 TEMP 32 TEMiP 33 TEMP 34 TEMP 35 TEMP 36 NUMBER Mi INS DFG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 DELETED 83.030 82.890 82.920 82.960 83.230 2 15 DELETED 83.030 82.880 82.900 82.960 83.230 3 30 DELETED 83.030 82.880 82-910 82.970 83.230 4 45 DELETED 83-030 82.850 82.910 82.970 83.250 60 DELETED 83 '40 82.890 82.930 82.990 83.230 6 75 DELETED "83.040 82.900 82.930 82.990 83.250 7 90 DELETED 83-050 82.900 82.940 82.980 83.240 8 105 DELETED 83.040 82.910 82.940 82.980 83.240 9 120 DELETED 83-050 82.900 82.950 82.990 83.240 10 135 DELETED 83.050 82.910 82.970 83.000 83.260 11 150 DELETED 83.060 82.920 82.950 82.990 83.240 12 165 DELETED 83.050 82.910 82.970 83.000 83.260 13 180 DELETED 83.060 82.920 82.970 83.000 83.270 14 195 DELETED 83.080 82.930 82.960 83.010 83.270 15 210 DELETED 83-070 82.940 82.980 83-020 83.280 16 225 DELETED 83.080 82.940 82.990 83-020 83.270 17 240 DELETED 83.080 82.940 82.990 83.020 83.290 18 255 DELETED 83 ~ 080 82.940 82 '90 83.020 83.280 END OF TABLE
VARIABLE TABLE
SUMMARY
SAYiPLE DELTA TEYiP 37 TEYiP 38 TEMP 39 TEMP 40 PRES 1 HUM NUMBER MINS DEG. F DEG. F DEG. F DEG. F PSIA FRACTION 1 0 82 '70 83.410 82.660 82.910 38.119 0.689 2 15 82.960 83.400 82.640 82-910 38.118 0.689 3 30 82.970 83-390 82.650 82.920 38.117 0.689 4 45 82.970 83.430 82.650 82.920 38.117 0.689 5 60 82.960 83.440 82.660 82.930 38.116 0.689 6 75 82.980 83.400 82.670 82.920 38.115 0.690 7 90 82.980 83.430 82.680 82.920 38.115 0.690 8 105 82.970 83.460 82.670 82.920 38.114 0.690 9 120 82.980 83.440 82.660 82.930 38.113 0.690 10 135 82.980 83.470 82.670 82-940 38.112 0.690 ll 12 150 165 82.990 82.980 83.430 83-440 82.680 82.680 82.940 82.940 38.112 38.111 0.690 0-690 13 180 83.000 83.420 82.650 82.940 38 110 F 0.690 14 195 83.010 83.450 82.690 82.950 38-110 0.690 15 210 83.030 83.440 82.690 82.950 38.109 0.690 16 225 83.010 83.450 82.710 82.960 38.108 0.690 17 240 83.040 83.450 82.710 82 '60 38.107 0 '90 18 255 83.030 83.430 82.700 82 '60 38.107 0.691 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 2 HUM 3 HUM 4 HUM 5 HUM 6 HUM 7 NUMBER MINS FRACTiON FRACTION FRACTION FRACTION FRACTION FRACTION 1 0 DELETED 0.705 0.686 0.699 0.694 0.688 2 15 DELETED 0.706 0-687 0.700 0 '95 0.688 3 30 DELETED 0.706 0.687 0.699 0.695 0 '88 4 45 DELETED 0.706 0.687 0.699 0.695 0.688 5 60 DELETED 0.706 0.687 0.699 0.695 0.688 6 75 DELETED 0.706 0 '87 0.700 0.695 0.688 7 90 DELETED 0.706 0.687 0.700 0.696 0.688 8 105 DELETED 0.706 0.687 0-700 0.695 0.688 9 120 DELETED 0.706 0.687 0.700 0.695 0.688 10 135 DEi ETED 0.706 0.687 0.699 0.696 0 '88 11 150 DELETED 0.706 0.687 0.700 0.696 0.689 12 165 DELETED 0.706 0.688 0.700 0.696 0.688 13 180 DELETED 0.706 0.687 0.700 0.695 0.689 14 195 DELETED 0.707 0.688 0.701 0.696 0.689 15 210 DELETED 0.707 0.688 0.700 0.696 0.689 16 225 DELETED 0.707 0.688 0.700 0.696 0.690 17 240 DELETED 0.707 0.688 0.701 0.696 0.689 18 255 DELETED 0.707 0.688 0.701 0.696 0.689 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 8 HUM 9 HUM io NUMBER MINS FRACTION FRACTION FRACTION 1 0 0.706 0.715 0.705 2 15 0.705 0.715 0.705 3 30 0.705 0-715 0.705 4 45 0.706 0.715 0.705 5 60 0.705 0.715 0.706 6 75 0.705 0.715 0.706 7 90 0.706 0.715 0.706 8 105 0.705 0.716 0.706 9 120 0.706 0.716 0.706 10 135 0.706 0.716 0.706 11 150 0.706 0 '16 0.706 12 165 0.706 0.716 0.706 13 180 0.706 0.716 0.706 14 195 0.707 0.716 0.706 15 210 0.706 0.716 0.706 16 225 0.706 0.716 0.706 17 240 0.707 0.716 0.707 18 255 0.706 0.716 0.707 END OF TABLE END OF REPORT ON CONTAINMENT LEAK RATE TEST TO NRC
9 ~ 17 LONTRINNENT RIR NRSSES '69040.
AIR NASS FITTED AIR MASS CV N
CS K
5 (a 468960. IC E
co 5 CJ 0
5 (Q 468880 Cp Cl CC'0 CS lat CI O
468800.
468720 468640' 60 ~ 120. 180 240 300 360. 420.
TINE IN MINUTES
9 ~ 17 ~ 21 '.
29 ~
0.4100 CQNPVTED LERK RATES SIMPLE MASS POINT LERK RATE Cal Ol FITTEO MASS POINT LEAK RRTE QJ tC 5
0.3600 0- IC I
I C7 0
CC n 5 0.3100 aal a
aal 5
O Ia.
0.2600 0 2100 0 1600 60 ~ 120. 180. 240. 300. 360. 420.
TIME IN MINUTES
9 ~ 17 25 29 0.6000 COMPUTED LERK RRTES RELRTIVE TQ LIMITS FITTED CLRT t1RSS POINT LEAKAGE RATE PIRXINUN RCCEPTABLE NINIHVH RCCEPTRBLE UJ 0.5000 n
0.4000 0 3000 0.2000 0.1000 0 ~ 60 ~ 120. 180. 240. 300. 360. 420.
TINE IN MINUTES
0 0
0
5 ~ 9 ~ 17 83.z4oo VOLUMETR I CRLLY HEI BHTED CONTR I NMENT TEMP ERRTURE
'LJ c
Ol t4 m
LLJ 83.2200 cal I
I C)
CE EJ X'C 5
QJ CI LLJ 83.2000 Ihl LLJ n aX
~4 5
83 1800 UJ CZ IJJ 83.1600 Q
UJ 83.14OO 420.
120. 180. 240. 300 360 ~
TIME IN MINUTE5
5 ~ 9 ~ 3 ~ 17 9 ~
38.1240 RVERRBE CONTRINNENT PRESSURE CS K
38.1200 ~C l4 I
I iC CJ 5
CR 38 1160
~
Ol QS sal 5
D a
38-1120 o 38.1080 38 1040 0 60 ~ 120. 180. 240. 300. 360. 420.
TINE IN MINUTES
5 ~ 9 ~ 7 0 5 0.3960 VOLUNETRICRLLY WEIGHTED VRPOR PRESSURE CC (Q
CL 0.3952 0.3944 0.3936 0.3928 0.3920 60 '20. 180. 240 300. 360. 420.
TINE IN MINUTES
U TEMPERATURE STABILIZATION 1300 91.404 1315 90.828 1330 90.335 1345 89.940 1400 89.619 1415 89.340 1430 89 '87 1445 ~
88.867 1500 88.703 1515 88-558 1530 88.402 1545 88-271 1600 88.148 1615 88.041 1630 87 937 1645 87-828 1700 87.736 0.917 0. 412 0.505 1715 87.640 0.797 0.401 0.396 1730 87 '41 0.699 0.396 0.303 1745 87.443 0-624 0.385 0-239 1800 87 330 0.572 0.406 0-166 1815 87-237 0.526 0.403 0.123 1830 87 '79 0.477 0.362 0.115
'845 87.3.11 0 '39 0.332 0.107 1900 87.010 0.423 0.320 0.103 1915 86.916 0.411 0.321 0.090 1930 86.850 0.388 0.329 0.059 A = TIME OF DAY IN MILITARY STANDARD B = AVERAGE CONTAINMENT TEMPERATURE F C = AVERAGE DIFFERENCE IN TEMP. OVER LAST 4 HOURS D = AVERAGE DIFFERENCE IN TEMP. OVER LAST 1 HOUR E = C - D
17 ~
)l ~
96.00 TENPERRTURE STABILIZATION CL s.
94.00 ~C CL'al I
I CS 92 00 90.00 88.GO 86 4 00 g 00 14 ~ 00 15.00 16.00 17.GO 18.00 19.00 20 0
~
TINE HOURS ( NIL I TRRY STRNDRRD )
FLORIDA POWER E( LIGHT COMPANY ST LUCIE PLANT UNIT NO. 2 CONTAINMENT INTEGRATED LEAKAGE RATE TFST LEAKACE RA E MEASURED USING THE ABSOLUTE METHOD LEAKAGE RATE COMPUTED USING THE MASS POINT METHOD TEST PERIOD STARTED AT 1215 HOURS ON NOVEMBER 30'982 TEST CONDUCTED FOR 24.00 HOURS FRFE SPACE VOLUME OF CONTAINMENT IS 2500000 CU FT CONTAINMENT WAS PRESSURIZED TO 59.68 PSIA INITIAL CONTAINMENT AIR WEIGHT 734034.8 LBS FINAL CONTAINMENT AIR WEIGHT 733849.6 LBS FITTED MASS POINT LEAKAGE RATE. IS 0.024 % PER DAY UPPER LIMIT OF 95 o CONFIDENCE LEVEL IS 0 '26 +o PER DAY NRC MAXIMUM ALLOWABLE LEAKAGE RATE IS 0.500 -o PER DAY
DESCRIPTION OF VARIABLES AVG. TEM CONTAINMENT MEAN TEMPERATURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RTD SENSOR INDICATIONS.
AVE. PRE PRIMARY CONTAINMENT PRESSURE INDICATION.
VAP. 'PRE CONTAINMENT VAPOR PRESSURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RHD SENSOR INDICATIONS.
LEAK SIM SIMPLE TOTAL TIME LEAKAGE RATE.
LEAK MAS LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MiASS DATA.
AIR MASS CONTAiNMiENT AIR MASS.
NOTE FOR TABULAR DATA TABLE VALUES OF ZERO SIGNIFY EITHER.
- i. DATA iS NOT APPLICABLE TO THE CALCULATION OR
- 2. SENSOR HAS BEEN DELETED FROM THE SCAN.
NOTE FOR CURVES
- i. TOP ABSCISSA SCALE REPRESENTS SAMPLE NUMBERS.
- 2. AIR MASS IS THE CALCULATED CONTAINMENT AIR MASS AND FITTED AIR MASS IS THE LINEAR LEAST SQUARE FIT OF THE AIR MASSES.
- 3. SIMPLE MASS POINT IS THE TOTAL TIME LEAKAGE RATE AND FITTED MASS POINT IS THE LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MASS DATA.
- 4. UCL IS THE UPPER LIMIT OF THE 95%
CONFIDENCE LEVEL OF AIR MASS DATA.
0 VARIABLE TABLE
SUMMARY
SAMPLE DELTA AVG- TEM AVG. PRE VAP ~ PRE LEAK SIM LEAK MAS AIR MASS NUMBER MINS DEG. F PSIA PSIA PER CENT PER CENT POUNDS 1 0 84.890 59.6850 0 4420 F 0.000 0.000 734035 2 15 84.865 59.6830 0.4418 -0.158 0.000 734047 3 30 84.866 59 '810 0.4419 0.109 0.109 734018 45 84.865 59.6800 0.4419 0-118 0.144 734008 5 60 84.830 59-6780 0.4415 0.002 0.053 734034 6 75 84.831 59.6760 0.4416 0.072 0.069 734007 7 90 84.827 59.6750 0.4415 0.071 0.075 734002 8 105 84.811 59-6730 0.4412 0.060 0.071 734002 9 120 84.784 59.6720 0.4411'.4412 0.011 0.042 734028 10 135 84.791 59-6700 0.061 0.050 733993 ll 12 150 165 84.774 84.777 59.6690 59.6680 0.4411 0.4414 0.040 0.061 0.045 0.051 734004 733984 13 180 84.765 59.6670 0.4412 0.049 0.050 733990 14 195 84.755 59.6650 0.4415 0.059 0.054 733976 15 210 84.738 59.6640 0.4414 0.046 0.051 733986 16 225 84.732 59 '630 0.4413 0.044 0.049 733984 17 240 84.731 59.6610 0.4415 0.063 0.053 733957 18 255 84.723 59.6610 0-4416 0.052 0.053 733967 19 270 84.709 59-6590 0.4414 0.052 0.053 733963 20 285 84.690 59.6580 0.4411 0.037 0.049 733981 21 300 84.697 59.6570 0.4412 0.051 0.049 733957 22 315 84.691 59-6550 0.4410 0.057 0.051 733943 23 330 84.687 59.6540 0.4410 0.059 0.053 733936 24 345 84.685 59-6530 0.4410 0.061 0.055 733927 25 360 84.671 59.6520 0.4408 0.054 0.055 733936 26 375 84.662 59-6500 0.4406 0.058 0-056 733925 27 390 84.655 59.6500 0.4404 0.049 0.055 733937 28 405 84.649 59.6480 0.4404 0.056 0.055 733920 29 420 84.649 59.6470 0.4405 0.060 0.056 733907 30 435 84.640 59.6460 0.4403 0.057 0-057 733909 31 450 84.636 59.6450 0.4403 0.058 0.057 733901 32 465 84.623 59-6440 0 '402 0.053 "
0.057 733910 33 480 84.616 59-6430 0.4401 0.052 0.056 733907 34 495 84.608 59.6420 0.4400 0.051 0.055 733907 35 510 84.604 59.6410 0.4399 0.051 0.055 733901 36 525 84.596 59-6400 0.4399 0.051 0.054 733898 37 540 84.585 59.6390 0.4397 0.048 0.053 733904 38 555 84.578 59.6380 0.4397 0.047 0.053 733901 39 570 84.574 59.6370 0.4397 0.048 0.052 733894 40 585 84.575 59 '360 0.4397 0.052 0.052 733880 41 .600 84.571 59.6350 0.4398 0.053 0.052 733873 42 615 84.559 59.6340 0.4395 0.050 0.052 733879 43 630 84.553 59.6340 0.4395 0.046 0.051 733888 44 645 84.546 59.6330 0.4393 0.045 0.050 733887 45 660 84.542 59.6320 0.4393 0.046 0.049 733881 46 675 84.536 59.6310 0.4393 0.046 0.049 733877 47 690 84.534 59.6310 0.4392 0.044 0.048 733880 48 705 84.527 59.6300 0.4392 0.044 0.047 733878 49 720 84.523 59.6290 0.4392 0.045 0.047 733870 50 735 84.517 59.6290 0.4390 0.041 0.046 733880
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA AVG. TEH AVG. PRE VAP. PRE LEAK SIH LEAK MAS AIR MASS NUMBER MINS DEG. F PSIA PSIA PER CENT PER CENT POUNDS 51 750 84.509 59.6280 0.4389 0.040 0.045 733880 52 765 84.510 59.6270 0.4390 0.043 0.045 733865 53 780 84.504 59.6260 0.4388 0.043 0.044 733863 54 795 84.496 59.6260 0.4387 0.039 0.044 733875 810 84-500 59.6250 0.4388 0.043 0.043 733857 56 825 84.491 59.6250 0.4387 0.039 0.043 733870 57 840 84.494 59.6240 0.4387 0.043 0.042 733852 58 855 84.482 59.6230 0.4387 0.041 0.042 733857 59 870 84.476 59.6230 0.4384 0.037 0.041 733869 60 885 84.474 59.6220 0.4385 0.039 0.041 733858 61 900 84.469 59.6230 0.4385 0.034 0.040 733877 62 915 84.467 59.6210 0.4385 0.038 0.039 733855 63 930 84.461 59.6210 0.4384 0.036 0.039 733864 64 945 84.461 59.6200 0.4383 0.038 0.038 733852 65 960 84.459 59.6200 0.4383 0.037 0.038 733855 66 975 84.454 59 '190 0.4383 0.037 0.037 733850 67 990 84.450 59.6190 0.4382 0.035 0.037 733857 68 1005 84.450 59.6180 0.4382 0.037 0.037 733845 69 1020 8".449 59.6180 0.4382 0.036 0.036 733846 70 1035 84.443 59.6180 0.4382 0.034 0-036 733854 71 1050 84.442 59.6170 0.4382 0.036 0.035 733843 72 1065 84.435 59.6170 0.4381 0.033 0.035 733854 73 1080 84.435 59 '170 0.4381 0.033 0.034 733853 74 1095 84.435 59.6160 0.4381 0.035 0.034 733841 75 1110 84.432 59.6160 0.4380 0.033 0.034 733847 76 1125 84.432 59.6150 0.4380 0.035 0.033 733835 77 1140 84.430 59.6150 0 4379 F 0.034 0.033 733838 78 1155 84.427 59.6150 0.4380 0.033 0.033 733842 79 1170 84.423 59.6150 0.4379 0.031 0.032 733847 80 1185 84.420 59.6140 0.4378 0.032 0.032 733840 81 1200 84.417 59.6140 0.4378 0.031 0.031 733844 82 1215 84.417 59.6140 0.4378 .0.031 0.031 733845 83 1230 84.416 59.6140 0.4377 0.030 0.031 733846 84 1245 84.411 59.6140 0.4376 0.028 0.030 733855 85 1260 84.412 59.6140 0.4378 0.029 0.030 733851 86 1275 84.410 59.6140 0.4377 0.028 0.029 733855 87 1290 84.407 59.6140 0.4376 0.027 0.029 733859 88 1305 84.404 59.6140 0.4377 0.026 0.028 733864 89 1320 84.406 59.6140 0.4377 0.026 0.028 733860 90 1335 84.403 59.6140 0.4376 0.025 0.027 733865 91 1350 84.401 59.6140 0.4375 0.024 0.026 733869 92 1365 84.403 59.6140 0.4376 0.024 0.026 733866 93 1380 84.393 59.6130 0.4375 0.024 0.025 733868 94 1395 84.398 59.6130 0.4376 0.025 0.025 733860 95 1410 84.401 59.6130 0.4377 0.025 0.025 733855 96 1425 84.399 59.6120 0.4376 0.026 0.024 733847 97 1440 84.397 59.6120 0.4375 0.025 0.024 733850 END O'P TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 1 TEMP 2 TEMP 3 TEMP 4 TEMP 5 TEMP 6 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 84.640 84.510 84.560 84.000 84.010 84.070 2 15 84.630 84.480 84-540 83.980 83.990 84.060 3 30 84.640 84.490 84.560 83.990 84-010 84.070 4 45 84.650 84.500 84.580 84.010 84-040 84.080 5 60 84.620 84.470 84.550 83.980 84.010 84 '50 6 75 84 '50 84.480 84.560 84.000 84.030 84.080 7 90 84.660 84.490 84.570 84.010 84.040 84.070 8 105 84.650 84.490 84.560 84.010 84.040 84.090 9 120 84.640 84.470 84.560 84.000 84.030 84.060 10 135 84.650 84.470 84.570 84.010 84.040 84.080 11 150 84.660 84.470 84.570 84.020 84.050 84.070 12 165 84.660 84.480 84.580 84.040 84.060 84.090 13 180 84.670 84.480 84.590 84.050 84.070 84.100 14 195 84.660 84.470 84.580 84.040 84.070 84.090 15 210 84.650 84.470 84 '80 84.040 84-070 84.090 16 225 84.630 84.460 84.580 84.040 84.080 84.080 17 240 84.670 84.480 84.590 84.050 84-090 84.110 18 255 84.680 84.480 84.600 84.050 84.090 84.110 19 270 84.670 84.480 84 '90 84.040 84.090 84.110 20 285 84.670 84.470 84.590 84.040 84.090 84.090 21 300 84.680 '84.480 84.600 84.060 84.100 84.100 22 315 84-670 84.480 84.600 84.060 84.100 84.100 23 330 84.680 84.490 84 '00 84.070 84.100 84.110 24 345 84.700 84.530 84.620 84.070 84.120 84.120 25 360 84.680 84.510 84.600 84.070 84.110 84.110 26 375 84.680 84.500 84.600 84.060 84.110 84.090 27 390 84.690 84.500 84.600 84.060 84.110 84.110 28 405 84.680 84.500 84.600 84.070 84.110 84-090 29 "
420 84.690 84.510 84.610 84.090 84.120 84-100 30 435 84 '90 84.470 84.610 84.080 84.120 84.110 31 450 84 '80 84.480 84.610 84.070 84.110 84-090 32 465 84 '90 84-460 84.610 84.080 84.110 84.090 33 480 84.700 84.470 84.610 84.080 84.120 84.090 34 495 84.680 84.460 84.610 84.080 84.110 84 '90 35 510 84.680 84.450 84.620 84.090 84.110 84.090 36 525 84.680 84.450 84 '10 84.080 84.120 84 080
~
37 540 84.680 84.480 84.600 84-080 84.120 84-090 38 555 84.680 84.440 84.580 84.080 84.110 84 '90 39 570 84.670, 84.470 84.570 84.090 84.110 84.090 40 585 84.680 84.480 84-580 84.100 84.120 '84.100 41 600 84 '80 84.440 84.570 84.090 84.130 84.090 42 615 84.680 84.430 84.570 84.090 84.120 84.'090 43 630 84.680 84.430 84.570 84.090 84.110 84.090 44 645 84 '80 84.440 84.560 84.080 84.120 84.080 45 660 84.680 84.430 84.560 84.090 84.120 84.080 46 675 84-680 84-410 '84.570 84.090 84.120 84.070 47 690 84.680 84.420 84.570 84.090 84.110 84.080 48 705 84.680 84.420 84.560 84.090 84.120 84.070 49 720 84.670. 84.390 84.560 84.090 84.110 84.080 50 735 84.670 84.420 84.550 84.090 84.110 84.070
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 1 TEMP 2 TEMP 3 TEMP 4 TEMP 5 TEMP 6 NUMBER MENS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F Sl 750 84.660 84.400 84.560 84.090 84.110 84.070 52 765 84.670 84-410 84.570 84.080 84.110 84.070 53 780 84.670 84.390 84.570 84.080 84.110 84.060 54 795 84.670 84.390 84-550 84.080 84.110 84.060 55 810 84.670 84 '80 84.560 84.090 84.110 84.070 56 825 84.660 84.380 84-570 84.080 84.120 84.070 57 840 84.670 84.370 84.570 84.100 84.120 84.090 58 855 84.660 84.360 84.560 84-080 84.110 84.060 59 870 84.670 84.370 84.570 84.090 84.120 84-050 60 885 84.670 84.370 84.570 84.090 84 110 F 84.060 61 900 84.670 84.370 84 '80 84.090 84.120 84.050 62 915 84.670 84.340 84-580 84.090 84.110 84.060 63 930 84.670 84.350 84.570 84.090 84.110 84.060 64 945 84.670 84.360 84-570 84.090 84.110 84.050 65 960 84-670 84.350 84.580 84.090 84.110 84.060 66 975 84.640 84.350 84.580 84.090 84.110 84.050 67 990 84.670 84.340 84.580 84.080 84.110 84.040 68 1005 84.670 84.350 84.580 84.090 84.100 84.050 69 1020 84.640 84.360 84.580 84.080 84.110 84.050 70 1035 84.660 84.330 84.580 84.090 84.110 84.050 71 1050 84.660 84.350 84-580 84.090 84.110 84.060 72 1065 84.620 84.330 84.570 84.090 84.100 84.050 73 1080 84.620 84.320 84.580 84.090 84-jjo 84.050 74 1095 84.620 84.330 84.580 84.090 84.100 84.050 75 1110 84.660 84.320 84.580 84.090 84.110 84.050 76 1125 84.650 84.330 84.580 84.090 84.100 84.050 77 1140 84.660 84.330 84-590 84.100 84.100 84.060 78 1155 84.660 84.330 84-580 84.090 84.100 84.050 79 1170 84.660 84.320 84.580 84.090 84.090 84.050 80 1185 84.660 84.330 84-590 84.090 84-100 84.040 81 1200 84.660 84.330 84.580 84.090 84.090 84.050 82 1215 84.660 84.330 84.580 84.090 84-090 84.050 83 1230 84.650 84.320 84.590 84.090 84-090 84.050 84 1245 84.650 84.320 84-580 84.090 84-090 84.050 85 1260 84.660 84.320 84.580 84.100 84.090 84.050 86 1275 84.660 84.310 84-580 84.100 84.100 84.040 87 1290 84.660 84.310 84.580 84.090 84-100 84.050 88 1305 84.660 84.310 84.580 84.100 84-090 84.050 89 1320 84.660 84.300 84-580 84.090 84-090 84.050 90 1335 84.660 84.310 84.580 84.100 84.100 84.050 91 1350 84.660 84.310 84-580 84-090 84.100 84.060 92 1365 84.670 84.270 84.590 84.100 84.100 84.070 93 1380 84.660 84.300 84.580 84-100 84.100 84-050 94 1395 84.660 84.300 84 '90 84.090 84.110 84.060 95 1410 84.660 84-300 84.590 84.110 84.110 84.070 96 1425 84-670 84.300 84.590 84.100 84.110 84.090 97 1440 84.670 84.300 84-580 84.110 84.120 84.060 END OF TABLE
VARZABLE TABLE
SUMMARY
SAYiPLE DELTA TEMP 7 'EMP 8 TEMP 9 TEMP 10 TEMP DEG.
ll F
TEYiP DEG.
12 F
NUMBER YiINS DEG. F DEG. F DEG. F DEG. F 1 0 84.850 84.220 84.990 85.060 84.930 82.910 2 15 84.830 84.200 84.930 85.020 84-890 82.870 3 30 84.840 84.220 84.920 85.010 84.880 82.860 4 45 84.860 84.240 84.910 85.010 84-830 82.860 5 60 84.830 84.210 84.870 84.960 84 '90 82.810 6 75 84.840 84.230 84.880 84.960 84.810 82.800 7 90 84.850 84.240 84.870 84.950 84,810 82.800 8 105 84.840 84.240 84 '50 84.920 84.790 82.770 9 120 84.830 84.220 84.800 84.890 84.750 82.740 10 135 84.840 84.240 84.810 84.880 84.750 82.740 ll 12 150 165 84.840 84.850 84.250 84.250 84.790 84.790 84.870 84.870 84.700 84 '10 82.720 82.710 13 180 84.850 84.260 84.770 84-850 84.670 82.690 14 195 84.850 84-260 84.740 84.840 84.680 82.670 15 210 84.850 84.260 84.720 84.820 84.650 82.660 16 225 84.850 84.270 84.720 84.800 84.650 82.650 17 240 84.850 84.280 84.720 84.800 84 '30 82.640 18 255 84.850 84.280 84.710 84.780 84.620 82.630 19 270 84.850 84.280 84.700 84.770 84.600 82.610 20 285 84.840 84.270 84.680 84.760 84.570 82.590 21 300 84.850 84.290 84.660 84.760 84.580 82.590 22 315 84.850 84.290 84.660 84.760 84.590 82.580 w3 330 84.850 84.290 84.640 84.760 84.580 82.560 24 345 84.860 84.300 84.640 84.750 84.570 82.,560 25 360 84.850 84.290 84.630 84 '30 84-570 82.540 26 375 84.840 84.300 84.610 84.720 84-550 82.520 27 390 84.850 84.300 84.610 84.720 84-530 82.510 28 405 84.840 84.300 84.600 84.710 84.550 82.490 29 420 84.850 84.310 84-600 84.710 84-550 82.500 30 435 84.840 84.310 84.580 84.700 84-530 82.480 31 450 84.840 84.300 84.570 84.700 84.510 82.490 32 465 84.840 84.310 84.570 84 '90 84.520 82.460 33 480 84.840 84.310 84.560 84-690 84.520 82.460 34 495 84.830 84.310 84.540 84 '70 84.510 82.460 35 510 84.840 84.,300 84.520 84.660 84.510 82.440 36 525 84-820 84.300 84.510 84.660 84.490 82.440 37 540 84.820 84.300 84.510 84.660 84.470 82.430 38 555 84.830 84.310 84.490 84.64o 84.470 82.400 39 570 84-820 84-300 84.480 84-640 84.470 82.400 40 585 84.830 84.310 84.490 84-650 84.480 82.400 41 600 84-830 84.310 84.480 84.640 84.460 82.390 42 615 84.820 84.310 84.470 84-630 84.460 82.400 43 630 84 810 F 84.300 84.450 84.620 84-450 82.380 44 645 84.810 84.300 84.430 84.610 84.430 82.370 45 660'75 84.810 84.300 84.430 84.610 84-430 82.360 46 84.810 84.300 84.430 84.,610 84.420 82.350 47 690 84.800 84.310 84.430 84 '10 84.410 82.340 48 705 84.800 84.300 84-400 84.600 84.390 82.340 49 720 84.800 84.310 84.400 84.590 84.410 82.320 50 735 84.790 84.300 84.380 84.580 84.400 82.330
VARIABLE TABLE SUYiMARY (CONTINUED)
SAMPLE DELTA TEHP 7 TEMP 8 TEMP 9 TEMP 10 TEMP 11 TEMP 12 NUYiBER HINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 .84.790 84.300 84.380 84.570 84.370 82.310 52 765 84.800 84.300 84.370 84.570 84.390 82.310,
'53 780 84.790 84.300 84.370 84.580 84-380 82.310 54 795 84.780 84.290 84.370 84.560 84.380 82.300 55 810 84.790 84.300 84 '60 84.560 84.390 82.300 56 825 84.780 84.300 84.350 84.550 84.370 82.300 57 840 84.790 84.310 84.350 84-560 84.370 82.310 58 855 84.770 84.300 84.350 84.540 84.360 82 '00 59 870 84.770 84.290 84.330 84-530 84-370 82.290 60 885 84.770 84.300 84.320 84.530 84.360 82.270 61 900 84.770 84.300 84.310 84.520 84.340 82.280 62 915 84.770 84.300 84.300 84.520 84.350 82.270 63 930 84.750 84.290 84.300 84.510 84.330 82 '60 64 945 84.760 84.300 84.300 84-510 84.340 82.270 65 960 84.760 84.290 '84.290 84.510 84.340 82.260 66 975 84.750 84-300 84.280 84.490 84.320 82.250 67 990 84.750 84.290 84.290 84.500 84.320 82.230 68 1005 84.750 84.290 84.280 84-500 84.320 82.240 69 1020 84.740 84.290 84.270 84.530 84.330 82.240 70 1035 84-740 84.290 84-270 84-490 84.320 82.240 71 1050 84.740 84.290 84.260 84.490 84-320 82.220 72 1065 84-740 84.280 84.240 84.490 84.300 82.230 73 1080 84.740 84.290 84.260 84.500 84.290 82.220 74 1095 84.740 84.290, 84.250 84.490 84.300 82.220 75 lllo 84.740 84.290 84.250 84-490 84-300 82.220 76 1125 84-730 84.290 84.240 84.480 84.300 82.200 77 1140 84.740 84.290 84.240 84.480 84 '10 82.210 78 1155 84.740 84.290 84.230 84.480 84.290 82.200 79 1170 84.730 84.290 84.230 84.480 84.300 82.200 80 1185 84.730 84.290 84.230 84.480 84.300 82.180 81 1200 84.730 84-290 84.220 84-470 84.270 82.200 82 1215 84.720 84.290 84.220 84.470 84.270 82.190 83 1230 84.730 84.290 84.220 84.470 84.290 82.190 84 1245 84.720 84.290 84.220 84.460 84.280 82.180 85 1260 84.720 84.290 84.210 84.460 84.280 82.180 86 1275 84 '20 84.290 84.210 84-460 84.280 82.170 87 1290 84.720 84.290 84.210 84.460 84.270 82.180 88 1305 84.720 84.290 84-200 84.450 84.280 82-3.60 89 1320 84.720 84.290 84 '10 84.450 84.270 82.190 90 1335 84.720 84.300 84-200 84.440 84-270 82.180 91 1350 84.720 84.290 84-200 84 440 F 84-260 82.180 92 1365 84 '30 84-300 84.210 84-450 84.270 82.180 93 1380 84.710 84.290 84.180 84.440 84.250 82.160 1395 84.720 84.300 84.190 84.440 84.260 82.180 95 1410 84.720 84:300 84-190 84-450 84.260 82.180 96 1425 84.730 84.310 84.190 84.440 84.260 82.190 97 1440 84.720 84.310 84.190 84-430 84.250 82.170 END OF TABLE
VARIABLE TABLE
SUMMARY
DEGAS SAMPLE DELTA TEMiP 13 TEMP 14 TFMiP 15 TEMP 16 TEMP 17 TEMP 18 NUIIBER MINS DEG. F F DEG. F DEG. F DEG. F DEG. F 1 0 85. 020 84.870 85.190 DELETED 85.000 84.930 2 15 84.980 84.830 85.150 DELETED 84.970 84.890 3 30 84.970 84.830 85.140 DELETED 84.960 84.890 45 84 '70 84.830 85.140 DELETED 84.970 84.880 5 60 84.920 84 780 F 85.080 DELETED 84.920 84.840 6 75 84.910 84.780 85.070 DELETED 84.910 84.840 7 90 84.910 84.770 85.050 DELETED 84.910 84.830 8 105 84-880 84.750 85.020 DELETED 84.880 84.800 9 120 84.850 84.720 84.970 DELETED 84.850 84.770 10 135 84 '50 84.720 84.970 DELETED 84.850 84.770 ll 12 150 165 84.830 84.830 84.700 84.700 84.960 84.950 DELETED DELETED 84 '40 84.840 84 84
'40
'40 13 180 84.810 84.680 84.930 DELETED 84.820 84.720 14 195 84.790 84.670 84.900 DELETED 84.800 84.710 15 210 84.780 84.650 84.860 DELETED 84. 77.0 84.680 16 225 84.770 84-640 84.850 DELETED 84.760 84.680 17 240 84.760 84.630 84.840 DELETED 84.760 84.660 18 255 84.750 84.620 84.840 DELETED 84.750 84.660 19 270 84.730 84.600 84.810 DELETED 84 '30 84.650 20 285 84-720 84.590 84.780 DELETED 84.710 84.630 21 300 84.720 84.580 84.790 DELETED 84.710 84.640 22 315 84.710 84.570 84.790 DELETED 84.710 84.630 23 330 84.700 84.570 84.770 DELETED 84.700 84.620 24 345 84.700 84.550 84.770 DELETED 84.690 84.610 25 360 84.690 84.530 84.760 DELETED 84.680 84.600 26 375 84.670 84.520 84.760 DELETED 84.670 84.,590 27 390 84.670 84.510 84.750 DELETED 84.670 84.580 28 405 84.660 84.500 84.740 DELETED 84.670 84.570 29 420 84.660 84.500 84.750 DELETED 84-660 84.570 30 435 84.660 84.490 84.750 DELETED 84.650 84.560 31 450 84.650 84.480 84.730 DELETED 84.640 84.560 32 465 84 '40 84.470 84.730 DELETED 84.640 84.550 33 480 84.630 84.470 84.720 DELETED 84.630 84.530 34 495 84.620 84.460 84.720 DELETED 84.620 84.530 35 510 84 '10 84.450 84.720 DELETED 84.610 84.520 36 525 84-600 84.440 84 '10 DELETED 84.610 84.510 37 540 84-580 84.430 84.700 DELETED 84.600 84.510 38 555 84.590 84.420 84.690 DELETED 84.600 84.490 39 570 84.580 84.410 84-690 DELETED 84.580 84.490 40 585 84.580 84.410 84.690 DELETED 84.590 84.490 41 600 84.580 84.410 84.680 DELETED 84.580 84.490 42 615 84.560 84.390 84.670 DELETED 84.570 84.480 43 630 84.560 84.390 84.660 DELETED 84 '70 84.470 44 645 84.550 84.380 84 '60 DELETED 84.550 84.450 45 660 84.540 84.370 84.640 DELETED 84.550 84.460 46 675 84.530 84.360 84.640 DELETED 84.550 84.450 47 690 84.530 84.360 84.640 DELETED 84.540 84.450 48 705 84.520 84.360 84.630 DELETED 84.540 84.430 49 720 84.520 84.360 84.630 DELETED 84.540 84.430 50 735 84.510 84.350 84.620 DELETED 84.530 84.420
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 13 EYiP 14 TEMP 15 TEMP 16 TEMP 17 TEMP 18 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 84.500 84.340 84.620 DELETED 84.520 84.410 52 765 84.510 84-340 84.620 DELETED 84.520 84.410 53 780 84.490 84.330 84.610 DELETED 84.520 84.400 54 795 84.480 84.320 84.600 DELETED 84.500 84.390 55 Sio 84.490 84.320 84.600 DELETED 84.510 84.400 56 825 s4.4so 84.320 84.600 DELETED 84.500 84.390 57 840 84.480 84.320 84.600 DELETED 84.490 84.380 58 855 84.470 84.300 84.580 DELETED 84.490 84.370 59 870 84.460 84.290 84.590 DELETED 84.480 84.370 60 885 84.460 84.300 84.580 DELETED 84.480 84.370 61 900 84.450 84.290 84.580 DELETED 84.470 84.360 62 915 84.450 84.280 84.570 DELETED 84.470 84-360 63 930 84.450 84-280 84.560 DELETED 84.470 84-360 64 945 84.450 84.280 84.570 DELETED 84.460 84.340 65 960 84.440 84.280 84.560 DELETED 84.460 84.350 66 975 84.440 84.270 84.560 DELETED 84.460 84.340 67 990 84.430 84.260 84-550 DELETED 84.450 84.340 68 1005 84.430 84.260 84.550 DELETED 84.450 84.340 69 1020 84.430 84.260 84 '40 DELETED 84.450 84.330 70 1035 84.420 84.260 84.540 DELETED 84 '40 84.330 71 1050 84.420 84.250 84.540 DELETED 84.440 84.340 i /2 73 1065 1080 84.420 84.410 84-250 84.240 84.530 84 '40 DELETED DELETED 84.430 84.430 84.320 84.320 "74 1095 84.410 84.250 84.530 DELETED 84.430 84.320 75 1110 84.410 84.250 84 '30 DELETED S4.420 84.320 76 1125 84.400 84.240 84.530 DELETED 84.430 84.320 77 1140 84.410 84.250 84.530 DELETED 84.430 84.320 78 1155 84.400 84.240 84-520 DELETED 84.420 84.310 79 1170 84.400 84.230 84.520 DELETED 84.410 84.310 80 1185 84.400 84.230 84.510 DELETED 84.410 84.310 81 1200 84.390 84.230 84.520 DELETED 84.410 84.300 82 1215 84.380 84.220 84.510 DELETED 84.410 84.300 83 1230 84-380 84.220 84.510 DELETED 84.410 84.300 84 1245 84.380 84.220 84.500 DELETED 84.400 84.300 85 1260 84.380 84.220 84.510 DELETED 84.400 84.300 86 1275 84.380 84.210 84.510 DELETED 84.400 84.290 87 1290 84-380 84.210 84-510 DELETED 84.400 84.290 88 1305 84.370 84.210 84.500 DELETED 84.390 84-290 89 1320 84.370 84.210 84.500 DELETED 84.400 84-290 90 1335 84.370 84.210 84.490 DELETED 84.390 84.280 91 1350 84.360 84.210 84.500 DELETED 84.390 84.290 92 1365 84.370 84.210 84-500 DELETED 84.390 84.280 93 1380 84.350 84.200 84.490 DELETED 84.380 84.270 94 1395 84.360 84.200 84.480 DELETED 84.390 84.280 95 1410 84.360 84 '00 84.490 DELETED 84.390 84.270 96 1425 84.360 84.200 84-490 DELETED 84.390 84.280 97 1440 84.360 84.190 84.490 DELETED 84.390 84.270 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA, TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP 24 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 84.950 81.490 84.930 85.010 85.360 84.830 2 15 84.940 81.480 84.890 84.980 85.340 84.810 3 30 84.940 81.480 84 '90 85.010 85.340 84.810 4 45 84-950 81.500 84.940 84.990 85.370 84.830 5 60 84.920 81.460 84.880 84.960 85.320 84.790 6 75 ,84.920 81.460 84.900 84.970 85.330 84.790 7 90 84.930 81.480 84.880 84.980 85.330 84 800
~
8 105 84.910 81-450 84.890 84.950 85.310 84.800 9 120 84-890 81.440 84.890 84.920 85.280 84.770 10 235 84.900 81.440 84.890 84.950 85.310 84.790 ll 12 150 165 84.890 84.900 81.440 81.450 84.870 84.870 84.930 84.940 85.310 85.300 84.770 84.780 13 180 84.890 81.440 84.880 84.940 85.300 84.760 14 195 84-880 81.430 84.870 84.930 ,85-290 84.760 15 210 84.860 81.410 84.860 84.910 85.280 84.760 16 225 84.860 81.420 84.890 84.900 85.270 84.770 17 240 84-870 81.420 84.860 84.900 85.280 84.770 18 255 84.850 81.4 0 84.840 84.910 85-270 84.750 19 270 84.840 81.400 84.830 84.890 85.260 84-750 20 285 84.830 81.390 84.820 84.870 85-230 84.730 21 300 84.840 81.390 84.810 84-890 85.270 84 '30 22 315 84 '30 81.390 84.820 84.870 85.250 84.740 23 330 84.830 81.390 84-820 84.870 85.250 84.740 24 345 84.830 . 81.380 84.820 84-880 85.250 84.750 25 360 84.820 81.370 84.800 84.880 85.250 84.740 .
26 375 84.810 81.360 84.810 84.860 85.250 84.720 27 390 84.800 81.360 84.810 84.850 85.230 84.720 28 405 84.800 81.350 84.800 84.850 85.230 84.710 29 420 84.800 81.350 84.790 84.860 85.240 84.710 30 435 84.790 81.350 84.800 84.840 85.240 84.710 31 450 84.790 81.330 84.780 84.900 85.240 84.720 32 465 8.4- 780 81.330 84-790 84.830 85.210 84.700 33 480 84.770 81.340 84-740 84.820 85.210 84.700 34 495 84,770 81.330 84.750 84.820 85.200 84.680 35 510 84.760 81.330 84.730 84.840 85-210 84.680 36 525 84 '60 81.330 84.760 84.810 85.200 84.680 37 540 84-750 81.310 84.760 84.800 85.190 84.670 38 555 84.740 81.300 84.720 84.800 85.190 84.670 39 570 84.730 81.300 84.710 84.790 85 '80 84.650 40 585 84.740 81.300 84.720 84.790 85.170 84.650 41 600 84.740 81.310 84.720 84.830 85.200 84.650 42 615 84.730 81.300 84.710 84.800 85.170 84.640 43 630 84.720 81.290 84.710 84.780 85.160 84.630 44 645 84.710 81.270 84.690 84.810 85.160 84.630 45 660 84.710 81.270 84.700 84.750 85.150 84.620 46 675 84.700 81-260 84.670 84 '50 85.140 84.620 47 690 84.700 81-260 84.690 84.760 85.140 84.610 48 . 705 84.690 81.250 84-660 84.750 85.140 84.620 49 720 84.690 81.250 84.660 84.730 85.130 84.610 50 735 84.670 81.260 84 '60 84.730 85.130 84.610
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP 24 NUMBER MINS DEG. F DEC. F DEG. F DEG. F DEG. F DEG. F 51 750 84.660 81.240 84.680 84.710 85.120 84.600 52 765 84-660 81-250 84.650 84.710 85.120 84.600 53 780 84.660 81.240 84.660 84.710 85.110 84.590 54 795 84.650 81.230 84.660 84.700 85.100 84.580 55 810 84.650 81.230 84.660 84.710 85.100 84.590 56 825 84.640 81.230 84.620 84.690 85.090 84.580 57 840 84.640 81.230 84.650 84.700 85.100 84.580 58 855 84.630 81.220 84.630 84.680 85.090 84.570 59 870 84.630 81.220 84.620 84.680 85.070 84.560 60 885 84.630 81.200 84.590 84.680 85-080 84.560 61 900 84.630 81.210 84.610 84.670 85.070 84.560 62 915 84.620 81.200 84.610 84.670 85 '60 84.560 63 930 84.620 81.210 84.590 84.660 85.060 84.550 64 945 84.610 81.210 84.600 84.660 85.060 84.540 65 960 84.610 81.190" 84.600 84.660 85.060 84.540 66 975 84.610 81.190 84.640 84.640 85.060 84.540 67 990 84.600 81.180 84.590 84.640 85.050 84.530 68 1005 84.600 81.180 84.590 84.640 85.040 84.530 69 1020 84.600 81.190 84.590 84.640 85.040 84.530 70 1035 84.600 81.170 84.580 84.640 85.030 84.530 71 1050 84.600 81.170 84.570 84.640 85.030 84.520 72 1065 84.590 81.170 84.590 84.620 85.030 84.520 73 1080 84.580 81.160 84.580 84.640 85.040 84.520 74 1095 84.590 81.170 84.580 84.630 85.030 84.530 75 1110 84.580 81.170 84.570 84.620 85.020 84.510 76 1125 84.580 81.170 84.580 84.620 85.040 84.530 77 1140 84.580 81.170 84.570 84-620 85.020 84.490 78 1155 84.570 81.160 84.570 84.620 85.020 84.500 79 1170 84.560 81.160 84.570 84.600 85.010 84-490 80 1185 84.560 81.160 84.560 84.610 85.010 84.490 Sl 1200 84-560 81-150 84.550 84 '30 85.000 84.490 82 1215 84.560 81.-150 84.570 84.600 85.010 84.500 83 1230 84.560 81.150 84.580 84.610 85.000 84.480 84 1245 84.550 81.150 84.560 84.600 85.000 84 '80 85 1260 84.550 81.150 84.560 84.590 85.000 84.480 86 1275 84.550 81.150 84.560 84.590 85.010 84.470 87 1290 84-540 81.150 84.560 84.590 84-990 84.480 88 1305 84.540 81.140 84.560 84.590 85.000 84.490 89 1320 84.540 81.140 84.550 84.590 85.000 84.490 90 1335 84.540 81.130 84.540 84.610 85.000 84.470 91 1350 84 '30 8'30 84.540 84.600 85 000 F 84.470 92 1365 84.540 81.120 84.550 84.580 84.990 84.470 93 1380 84.530 81.120 84.500 84.580 84.990 84.470 94'5 1395 84.530 81-140 84.540 84-580 84.980 84.470 1410 84.540 81.130 84.550 84 '80 84.990 84.480 96 1425 84-530 81.130 84-510 84.580 84.990 84.470 97 1440 84.530 81.130 84.550 84.580 84.980 '4.470 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEMP 30 NUMBER MINS DEG. F DEG- F DEG. F DEG. F DEG. F DEG- F 1 0 85 '30 84.950 84.960 85.210 85.020 84.520 2 15 85.020 84.940 84.950 85.200 85.000 84.500 3 30 85.020 84 '40 84.950 85.210 84.990 84.490 45 85 '30 84.950 84-960 85.220 84.980 84.480 5 60 85 000 F 84.930 84 '30 85.190 84.940 84.440 6 75 85.000 84.930 84.930 85.190 84.930 84
'30'4.410 7 90 85.010 84.930 84.930 85.180 84.910 8 105 85.000 84 '20 84.920 85.180 84.890 84.390 9 120 84.970 84 '90 84.900 85 '50 84.860 84.360 10 135 84.990 84.910 84-910 85.170 84.860 84.350 ll 12 150 165 84.960 84.980 84.890 84.890 84-900 84-910 85.160 85.170 84.830 84.830 84.330 84.330 13 180 84.970 84.890 84.910 85.160 84.810 84.310 14 195 84.970 84.890 84.890 85.150 84.780 84.290 15 210 84.960 84.880 84.880 85.140 84.760 84.270 16 225 84.960 84.870 84.880 85.1'40 84.760 84.260 17 240 '4.960 84.880 84.880 85.150 84.750 84.240 18 255 84.960 84.880 84.880 85.140 84.750 84.230 19 270 84.950 84-860 84-870 85.130 84.720 84.220 20 285 84.920 84.840 84.850 85.110 84.700 84.200 21 300 84.930 84.850 84.860 85.130 84.700 84.200 22 315 84.930 84.840 S4.S60 85.120 84.690 84-200 23 330 84.930 84.840 84.860 85 '20 84.680 84.200 24 345 84.920 84.840 84.850 85.110 84.660 84.180 25 360 84.920 84.820 84.840 85.110 84.650 84.160 26 375 84.910 84.810 84.840 85.100 84.640 84.150 27 390 84.900 84.810 84.830 85.090 84.620 84.140 28 405 84.900 84.810 84.830 85.090 84.620 84.130 29 420 84.900 84-790 84.830 85.090 84-600 84.120 30 435 84.890 84 '80 84.830 85.080 84.590 84.130 31 450 84.900 84.800 84.850 85.090 84.580 84.100 32 465 84.870 84.760 84.810 85.080 84.570 84.090 33 480 84.870 84.770 84.800 85 '60 84.550 84.090 34 495 84.860 84.760 84-800 85 '60 84.540 84.060 35 510 84.860 84.760 84.810 85.060 84.530 84.060 36 525 84.860 84.740 84.790 85.060 84.520 84-040 37 540 84.840 84.730 84.770 85.050 84.500 84.020 38 555 84.830 84.730 84.770 85-050 84.500 84.020 39 570 84.830 84.730 84.770 85.040 84.490 84.010 40 585 84.840 84.730 84.760 85.030 84.490 84.010 41 600 84.830 84.730 84.760 85.030 84.480 84.000 42 615 84.820 84.710 84.750 85.020 84.480 83.990 43 630 84-810 84.710 84.750 85.020 84.460 83.990 44 645 84-800 84.710 84.740 85. 010 84.460 83.970 45 660 84.790 84.690 84.740 85.000 84.450 83.960 46 675 84.810 84-690 84.730 85.000 84.440 83.960 47 690 84.790 84.690 84.730 85.000 84.440 83.950 48 705 84.780 84.690 84.730 84.990 84.430 83.950 49 720 84.780 84.690 84.710 84.990 84.430 83.940 50 735 84.770 84.680 84.710 84.990 84.410 83.920
0 VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEYiP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEYiP 30 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 51 750 84.760 84 '80 84 '10 84.980 84.400 83.910 52 765 84.760 84.660 84.710 84.990 84.410 83.920 53 780 84.760 84.660 84.700 84.980 84.410 '3.920 54 795 84.750 84.650 84-690 84-960 84.390 83.900 55 810 84.740 84.660 84 '90 84.960 84.390 83.910 56 825 84.730 84-660 84-680 84.950 84.380 83.900 57 840 84.740 84.650 84.680 84.950 84.400 83.900 58 855 84 '30 84.640 84.670 84.940 84.370 83.900 59 870 84.710 84.620 84.660 84.940 84.360 83.880 60 885 84.720 84.630 84.670 84.940 84.350 83.880 61 900 84.710 84.620 84.660 84.940 84.340 83.880 62 915 84.700 84.630 84.670 84.930 84.350 83.870 63 930 84.700 84.620 84.640 84.920 84.350 83.860 64 945 84 '00 84 '20 84.650 84.920 84.340 83.870 65 960 84.700 84.610 84.650 84.920 84.340 83.870 66 975 84.690 84.610 84.640 84.920 84.340 83-870 67 990 84.690 84.590 84-650 84.910 84.330 83.850 68 1005 84.690 84.600 84 '40 84.910 84 '40 83-850 69 1020 84.690 84.590 84.630 84.900 84.330 83.850 70 1035 84.680 84.590 84.630 84.900 84.330 83.840 71 1050 84.680 84 '80 84.630 84.900 84.330 83.840 72 1065 84.670 84-580 84.640 84.920 84.320 83.830 73 1080 84.670 84.590 84.620 84.900 84.330 83.830 74 1095 84.670 84.590 84.620 84.910 84.320 83.830 75 1110 84.660 84.560 84.620 84.890 84.310 83.820 76 1125 84 '70 84 '70 84.610 84.890 84.320 83.820 77 1140 84.660 84.580 84.610 84.890 84.300 83.810 78 1155 84.660 84 '80 84.620 84.890 84-300 83.810 79 1170 84.650 84.570 84.610 84.880 84.310 83.810 80 1185 84 '50 84 '70 84.610 84.880 84-290 83.800 81 1200 84.640 84.570 84.600 84.870 84.300 83.800 82 1215 84.650 84.570 84.600 84.880 84-290 83.800 83 1230 84.640 84.570 84.600 84.880 84 '90 83-800 84 1245 84.640 84.560 84.600 84.870 84.280 83 F 800 85 1260 84.640 84.560 84.600 84.870 84.280 83.800 86 1275 84.640 84.560 84.590 84.860 84.280 83.800 87 1290 84.640 84.560 84.600 84.860 84.270 83-790 88 1305 84.630 84.550 84.590 84.870 84.270 83.790 89 1320 84.640 84-560 84.590 84.860 84.270 83.790 90 1335 84.630 84.540 84.590 84.860 84-270 83.780 91 1350 84.630 84.550 84.590 84.860 84-270 83.780 92 1365 84.630 84.540 84.590 84.850 84 '70 83 '80 93 1380 84.620 84.540 84.580 84.850 84.260 83.770 94 1395 84.620 84.540 84.590 84.850 84.260 83 '80 95 1410 84.620 84.550 84.590 84.860 84.270 83.780 96 1425 84.620 84.540 84.580 84.860 84-260 83.780 97 1440 84 '20 84.540 84.590 84-850 84.260 83.780 END OF TABLE
VARIABLE TABLE SUYMARY DEGAS SAMPLE DELTA TEMP 31 TEMP 32 TEYiP 33 TEMP 34 TEiMP 35 TEMP 36 iVUYiBER KINS DEG. F F DEG ~ F DEG. F DEG. F DEG. F 1 0 DELETED 85.050 84.910 85.040 85.000 85.250 2 15 DELETED 85.020 84 880 F 85.030 84.960 85.220 3 30 DELETED 85.020 84.880 85.030 84.970 85.220 45 DELETED 85.000 84.870 84.970 84.960 85.210 5 60 DELETED 84.970 84.830 84.960 84.930 85.180 6 75 DELETED 84.960 84.810 84.940 84.910 85.160 7 90 DELETED 84.940 84.790 84.920 84.900 85.150 8 105 DELETED 84.930 84.780 84.920 84.870 85.130 9 120 DELETED 84.890 84.740 84.860 84.840 85.100 lo 135 DELETED 84.900 84.740 84.870 84.850 85.100 11 150 DELETED 84.870 84.710 84.860 84.810 85.060 12 165 DELETED 84.860 84.710 84.840 84.810 85.070 13 180 DELETED 84.850 84.690 84-840 84.780 85.040 14 195 DELETED 84.830 84.680 84.820 84.780 85.030 15 210 DELETED 84.800 84.650 84.790 84 '50 85.000 16 22S DELETED 84.790 84.640 84.720 84.740 85.000 17 240 DELETED 84.780 84.630 84.710 84.730 84.990 18 2S5 DELETED 84.760 84.620 84.710 84 '20 84.970 19 270 DELETED 84.740 84.600 84.690 84.690 84.950 20 285 DELETED 84.710 84.570 84.660 84.660 84.920 21 300 DELETED 84.720 84.570 84.670 84.660 84-940 22 3'5 DELETED 84.700 84.560 84.660 84.650 84.920 23 330 DELETED 84.690 84.550 84.650 84.640 84.910 24 345 DELETED 84.680 84.530 84.680 84.620 84-890 25 360 DELETED 84.660 84.520 84 '30 84.600 84.870 26 375 DELETED 84.650 84.510 84.630 84 '90 84.870 27 390 DELETED 84.640 84.490 84.620 84.580 84.850 28 405 DELETED 84.630 84.480 84.590 84.570 84.850 29 420 DELETED 84.630 84.460 84.570 84.560 84.830 30 435 DELETED 84.620 84.470 84.560 84.550 84.820 31 450 DELETED 84.660 84.450 84.550 84.540 84.810 32 465 DELETED 84.600 84.440 84.520 84.510 84.800 33 480 DELETED 84.580 84.420 84.530 84.500 84.780 34 495 DELETED 84.570 84.410 84.540 84.490 84.770 35 510 DELETED 84.560 84.390 84.540 84.480 84.760 36 525 DELETED 84.550 84.380 84.520 84.470 84.760 37 540 DELETED 84.530 84-370 84.470 84.450 84.730 38 555 DFLETED 84.530 84.360 84.460 84.440 84.730 39 570 DELETED 84.520 84.350 84.460 84.430 84.720 40 585 DELETED 84.520 84.350 84.460 84.430 84.710 41 600 DELETED 84. 510 84.340 84.450 84.420 84.710 42 615 DELETED 84.500 84.330 84.430 84.410 84.700 43 630 DELETED 84.490 84; 320 84.440 84.400 84.690 44 645 DELETED 84.320 84.430 84.390 84.680 84 '30 84.480'4.470 45 660 DELETED 84.310 84.390 84.670 46 675 DELETED 84 '70 84.300 84.420 84.390 84.670 47 690 DELETED 84.460 84.300 84.430 84.370 84-660 48 705 DELETED 84.450 84.300 84.440 '4.370 84.660 49 720 DELETED 84.450 84.290 84.430 84.360 84.650 50 735 DELETED 84.440 84.280 84.430 84.360 84.640
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 31 TEMP 32 TFMP 33 TEMP 34 TEMP 35 TEMP 36 NUMBER MINS DEG. F DHG. F DEG. F DEG. F DEG. F DEG. F 51 750 DELETED 84.440 84.280 84.400 84.350 84.640 52 765 DELETED 84.440 84.280 84.390 84.350 84.640 53 780 DELETED 84.430 84.260 84.380 84-340 84.630 54 795 DELETED 84.420 84.260 84.400 84.330 84.610 55 810 DELETED 84.420 84.260 84.370 84.340 84.620 56 825 DELETED 84.410 84.250 84.370 84.330 84.600 57 840 DELETED 84.410 84.250 84.370 84.330 84.610 58 855 DELETED 84.400 84.250 84.380 84.320 84.600 59 870 DELETED 84.390 84.230 84.350 84.310 84.590 60 885 DELFTED 84.390 84.230 84.360 84 '10 84.590 61 900 DELETED 84.380 84 '20 84.360 84.300 84.580 62 915 DELETED 84.380 84.220 84.360 84.300 84.580 63 930 DELETED 84.370 84 '20 84.350 84.290 84.570 64 945 DELETED 84.370 84.210 84.350 84.280 84.570 65 960 DELFTED 84 '70 84.210 84.350 84.280 84.570 66 975 D"LETED 84.370 84.200 84.320 84.270 84.560 67 990 DELETED 84.360 84.220 84.340 84.270 84.560 68 1005 D"LETED 84.350 84.190 84.340 84.270 84.560 69 1020 DELETED 84.360 84.200 84.330 84.270 84.560 70 1035 DELETED 84.350 84.190 84.340 84.270 84.550 71 1050 DELETED 84.350 84.190 84.320 84.260 84.550 72 1065 DEi ETED 84.340 84.180 84.310 84.250 84.540 73 1080 DELETED 84.340 84.180 84.310 84.260 84.540 74 1095 DELETED 84.350 84.180 84 '10 84.260 84.540 75 ilo DELETED 84.340 84.170 84.320 84.260 84.530 76 1125 DELETED 84.330 84.170 84.320 84-260 84.540 77 1140 DELETED 84.330 84.170 84.320 84.240 84.530 78 1155 DELETED 84.330 84.160 84 '20 84.240 84.530 79 1170 D"LETED 84.320 84.160 84.340 84.230 84.530 80 1185 DELETED 84.320 84.160 84.320 84.230 84.530 81 1200 DFLETED 84.310 84.150 84.320 84.230 84.520 82 1215 DELETED 84.310 84.160 84.330 84-230 84.510 83 1230 DELETED 84.310 84.150 84 '20 84.230 84.520 84 1245 DELETED 84.300 84.150 84.300 84.230 84-510 85 1260 DELETED 84.300 84.150 84 '10 84.230 84.510 86 1275 DELETED 84.310 84.140 84.310 84.220 84.510 87 1290 DELETED 84.300 84.140 84.300 84.210 84.500 88 1305 DELETED 84.300 84.140 84-300 84.220 84.500 89 1320 DFLETED 84.300 84.140 84.300 84.220 84.510 90 1335 DELFTED 84.290 84.140 84.310 84.210 84.500 91 1350 DELETED 84.290 84-130 84-290 84.210 84.500 92 1365 DELETED 84.290 84.120 84.290 84.210 84.500 93 1380 DELETED 84.280 84.120 84-290 84.210 84.490 94 1395 DELETED 84.290 84.130 84.290 84.210 84.500 95 1410 DELETED 84.290 84-130 84.300 84.210 84.500 96 1425 DELETED 84.290 84.120 84.290 84.210 84.490 97 1440 DELETED 84.280 84.120 84.300 84.200 84.490 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 37 TEMP 38 TEMP 39 TEMP 40 PRES 1 HUM 1 NUMBER MINS DEG. F DEG. F DEG. F DEG. F PSIA FRACTION 1 0 84.980 85.420 84.640 84.930 59.685 0.707 2 15 84-960 85.390 84.630 84.910 59.683 0.708 3 30 84.950 85.390 84 '40 84.910 59.681 0.708 4 45 84.940 85.360 84.600 84.880 59.680 0.709 5 60 84.910 85.350 84.590 84.850 59.678 0.710 6 75 84-890 85.340 84.580 84.840 59.676 0 ~ 711 7 90 84-880 85.300 84.560 84.850 59.675 0.712 8 105 84.850 85.290 84 '40 84.810 59 '73 0.712 9 120 84.820 85.260 84.510 84.790 59.672 0.713 10 135 84-830 85.250 84.510 84.800 59.670 0.714 ll 12 150 165 84.790 84.790 85.220 85.230 84.480 84.480 84.760 84 '60 59-669 59.668 0.715 0.715 13 180 84.760 85 '00 84-460 84.730 59.667 0.716 14 195 84.760 85-190 84.440 84.730 59.665 0.718 15 210 84.740 85.160 84.430 84.710 59.664 0.719 16 225 84.710 85.150 84.410 84.700 59.663 0.720 17 240 84.710 , 85.140 84.410 84.700 59.661 0.720 18 255 84-700 85.140 84.380 84.670. 59.661 0.722 19 270 84.670 85.110 84-370 84.650 59.659 0.723 20 285 84.650 85.080 84 '40 84.620 59.658 0.725 21 300 84-660 85.080 84.350 84.620 59.657 0.726 22 315 84.640 85.070 84.330 84.610 59.655 0.727 23 330 84.640 85.070 84.320 84.600 59.654 0.728 24 345 84-620 85 '60 84.300 84.580 59.653 0.728 25 360 84.610 85.030 84.280 84.560 59.652 0.729 26 375 84.600 85.030 84-270 84.550 59.650 0.729 27 390 84.580 85.010 84.260 84.520 59.650 0.729 28 405 84.570 85.000 84.250 84.520 59.648 0.730 29 420 84.550 84.990 84.250 84.520 59.647 0.730 30 435 84.550 84.980 84.200 84.500 59.646 0.730 31 450 84.540 84.960 84.210 84.480 59.645 0.731 32 465 84.530 84.950 84 '00 84.460 59.644 0.731 33 480 84.510 84.940 84.190 84.450 59.643 0.731 34 495 84.500 84.910 84-180 84.430 59.642 0.731 35 510 84.500 84.910 84.160 84.430 59.641 0.731 36 525 84.490 84-910 84-150 84.420 59.640 0.732 37 540 84.460 84.880 84.140 84.400 59.639 0.732 38 555 84.460 84.870 84.130 84.400 59.638 0.732 39 570 84.520 84.880 84.110 84.380 59.637 0.732 40 585 84.450 84.880 84.110 84.370 59.636 0 '32 41 600 84.440 84.870 84.090 84.370 59.635 0.732 42 615 84.430 84 '40 84.050 84.350 59.634 0.732 43 630 84.420 84.830 84.080 84.340 59.634 0.732 44 645 84.410 84.820 84.070 84.350 59.633 0.732 45 660 84.410 84.840 84.070 84.340 59-632 0.732 46 675 84.410 84.810 84-050 84.330 59.631 0.732 47 690 84.400 84-830 84.040 84.320 59.631 0.732 48 705 84.390 84-800 84.030 84.310 59.630 0.733 49 720 84.380 84.800 84.050 84.310 59.629 0.732 50 735 84.380 84.790 84.050 84.290 59.629 0.733
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA TEMP 37 TEMP 38 TEMP 39 TEMP 40 PRES 1 HUM 1 NUMBER MINS DEG. F DEG. F DEG. F DEG. F PSIA FRACTION 51 750 84.370 84.770 84.020 84.280 59.628 0.733 52 765 84.380 84.770 84.030 84.280 59.627 0.733 53 780 84.360 84.770 84.010 84.280 59.626 0.733 54 795 84.350 84.760 84.010 84.280 59-626 0.733 55 810 84.350 84.760 84.050 84.270 59.625 0.733 56 825 84.350 84.750 84.000 84.270 59 '25 0.733 57 840 84.350 84.750 84.010 84.260 59.624 0 733
~
58 855 84.330 84.730 83.980 84.250 59.623 0.733 59 870 84.330 84.730 83.980 84 '30 59.623 0.733 60 885 84.330 84.730 83.970 84.240 59.622 0.733 61 900 84.310 84.720 83.960 84.220 59.623 0.733 62 915 84.310 84.720 83.970 84.220 59.621 0.733 63 930 84.310 84-710 83.960 84.220 59 '21 0.733 64 945 84.310 84.710 83.960 84.220 59.620 0.733 65 960 84.300 84.720 83.950 84.220 59.620 0.734 66 975 84.300 84.710 83.950 84.220 59.619 0.733 67 990 84.300 84.710 83.960 84.200 59.619 0.734 68 1005 84.290 84.700 83.960 84.220 59.618 0.733 69 1020 84.290 84.700 83.970 84.220 59.618 0.734 70 1035 84.290 84.700 83.930 84.210 59.618 0.734 71 1050 84.290 84.700 83.950 84.200 59.617 0.734 72 1065 84.280 84.690 83.950 84.200 59.617 0.734 73 aoso 84.270 84.690 83.950 84.200 59.617 0.734 74 1095 84.270 84.690 83.940 84.200 59.616 0.734 75 1110 84.270 84.680 83.930 84.200 59.616 0.734 76 1125 84.270 84.690 83.950 84.180 59.615 0.734 77 1140 84.260 84.680 83.930 84.170 59.615 0.734 78 1155 84.270 84-680 83.940 84.180 59.615 0.734 79 1170 84.280 84.670 83.930 84.180 59.615 0.734 80 1185 84.250 84.670 83.920 84.170 59.614 0.734 81 1200 84.250 84.660 83.910 84.170 59.614 0.734 82 1215 84.250 84.680 83.920 84.160 59.614 0.734 83 1230 84.250 84.680 83.910 84 '50 59 '14 0.734 84 1245 84.240 84.660 83.910 84.150 59.614 0.734 85 1260 84.240 84.680 83.910 84.160 59.614 0.734 86 1275 84.240 84.660 83.910 84. 160 59.614 0.734 87 1290 84.240 84.650 83.900 84.160 59.614 0.734 88 1305 84.240 84-650 83.870 84.140 59.614 0.734 89 1320 84.240 84.660 83.900 84.150 59.614 0.734 90 1335 84.230 84.660 83.890 84.150 59.614 0.734 91 1350 84.230 84.650 83 880 F 84.150 59.614 0.734 92 1365 84.220 84-650 83.930 84.150 59.614 0.734 93 1380 84.220 84 '30 83.880 84.150 59.613 0.734 94 1395 84.230 84-660 83.880 84.130 59.613 0.734 95 1410 84.230 84.640 83.880 84.150 59.613 0.734 96 1425 84.220 84.640 83.870 84.140 59.612 0.734 97 1440 84.220 84.640 83.880 84.140 59.612 0.734 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 2 HUM 3 HUM 4 HUM 5 HUM 6 HUM 7 NUMBER MINS FRACTION FRACTION FRACTION FRACTION FRACTIOh'.713 FRACTIOh'.705 1 0 DELETED 0.719 0.700 0.714 2 DELETED 0.720 0.701 0.714 0.714 0.706 3 30 'DELETED 0.721 0.702 0.717 0.715 0.706 4 45 DELETED 0.722 0.703 0.716 0.716 0.707 5 60 DELFTED 0.722 0 ~ 704 0.718 0.717 0.708 6 75 DELETED 0.723 0.705 0.718 0.718 0.709 7 90 DELETED 0.724 0.706 0.719 0 ~ 718 0.710 8 105 DELETED 0.724 0.707 0.720 0.719 0.711 9 120 DELETED 0.725 0.709 0.721 0.721 0.712 10 135 DELETED 0 ~ 726 0.710 0.723 0.721 0.713 ll 12 150 165 DELETED DELETED 0.727 0.727 0.710 0 ~ 712 0.724 0.724 0.723 0.724 0.714 0.715 13 180 DELETED 0.728 0.7'3 0.725 0.725 0.716 14 195 DELETED 0.729 0.714 0.727 0.726 0.717 15 210 DELETED 0.730 0.716 0.727 0.727 0.718 16 225 DELETED 0.731 0.718 0.729 0.728 0.719 17 240 DELETED 0.732 0.719 0.730 0.730 0.721 18 255 DELETED 0.733 0.721. 0.731 0.731 0.722 19 270 DELETED 0.734 0.722 0.733 0.733 0.723 20 285 DELETED 0.735 0.723 0.734 0.734 0.724 21 300 DELETED 0.736 0.724 0.735 0.733 0.725 22 315 DELETED 0.737 0.725 0.735 0.734 0.725 23 330 DELETFD 0-738 0.725 0. 736 0.734 0.726 24 345 DELETED 0 738
~ 0.725 0.736 0.735 0. 727 25 360 DELETED 0.739 0.726 0.737 0.735 0.727 26 375 DELETED 0.740 0.726 0.737 0.736 0.727 27 390 DELETED 0.740 0.726 0.737 0.736 0.728 28 405 D"LETED 0.741 0.727 0.738 0.736 0.728 29 420 DELETED 0.741 0.727 0.739 0.736 0.729 30 435 DELETED 0.742 0.727 0.738 0.736 0.729 31 450 DELETED 0.743 0.728 0.739 0.737 0 ~ 729 32 465 DELETED 0.743 0.728 0.739 0.737 0.730 33 480 DELETED 0.743 0.728 0.739 0.737 0.730 34 495 DELETED 0.743 0.728 0.740 0.737 0.730 35 510 DELETED 0.744 0.728 0.740 0.737 0.731 36 525 DELETED 0.744 0.728 0.741 0.737 0.731 37 540 DELETED 0.744 0.728 0.741 0.737 0.730 38 555 DELETED 0.744 0.728 0.741 0.738 0.731 39 570 DELETED 0.744 0.728 0.741 0.738 0.731 40 585 DELETED 0.744 0-728 0.741 0.738 0.731 41 600 DELETED 0.745 0.728 0.741 0.738 0.731 42 615 DELETED .0. 745 0.728 . 0.741 0.738 0.732 43 630 DELETED 0.745 0.728 0.741 0.738 0.731 44 645 DELETED 0.745 0.729 0.741 0.738 0.731 45 660 DELETED 0.745 0.729 0.741 0.738 0.732 46 675 DELETED 0.745 0.729 0.741, 0.738 0.732 47 690 DELETED 0.745 0.729 0.742 0.738 0.732 48 705 DELETED 0.745 0.729 0.742 0.738 0.732 49 720 DELETED 0.745 0.729 0.742 0.739 0.732 50 735 DELETED 0.745 0.729 0.742 0.739 0.732
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA HUMi 2 HUM 3 HUMi 4 HUM 5 HUM 6 HUM 7 NUMBER MINS FRACTION FRACTION FRACTION FRACTION FRACTION FRACTION 51 750 DELETED 0.745 0.729 0.742 0.739 0.732 52 765 DELETED 0.745 0.729 0.742 0.739 0.732 53 780 DELETED 0.745 0.729 0.742 0.739 0.732 54 795 DELETED 0.745 0.729 0.742 0.739 0.732 55 810 DELETED 0.746 0.729 0.742 0.739 0.732 56 825 DELETED 0.746 0.730 0.742, 0.739 0.732 57 840 DELETED 0.746 0.730 0.742 0.739 0.733 58 855 DELETED 0.746 0.730 0.743 0.739 0.733 59 870 DELETED 0.746 0.729 0.742 0.739 0.732 60 885 DELETED 0.746 0.730 0.743 0.739 0.732 61 900 DELETED 0.746 0.730 0.743 0.739 0.733 62 915 DELETED 0.746 0 '30 0.742 0.739 0.733 63 930 DELETED 0.746 0.730 0.743 0.739 0.733 64 945 DELETED 0.746 0.730 0.742 0.740 0.733 65 960 DFLETED 0.746 0.730 0.742 0.740 0.733 66 975 DELETED 0.746 0.730 0.743 0.-739 0.733 6/ 990 DELETED 0.746 0.731 0.743 0.739 0.733 68 1005 DELETED 0.746 0.730 0.743 0.740 0.733 69 1020 DELETED 0.746 0.730 0.'43 0.740 0.733 70 1035 DELETED 0.746 0.730 0-743 0.740 0.733 71 1050 DELETED 0.746 0.730 0.743 0.740 0.733 72 1065 DELETED 0.746 0.730 0.743 0.740 0.733 73 1080 DELETED 0.746 0.730 0.743 0.740 0.733 74 1095 DELETED 0.746 0.731 0.743 0.740 0.733 75 1110 DELETED 0.746 0.730 0.743 0.740 0.733 76 1125 DELETED 0.746 0.730 0.743 0.740 0.733 77 1140 DELETED 0-746 0.730 0.743 0.740 0.733 78 1155 DELETED 0.746 0.731 0.743 0.740 0.733 79 1170 DELETED 0.746 0.730 0.743 0.740 0.733 80 1185 DELETED 0.746 0.730 0.743 0.740 0.733 81 1200 DELETED 0.746 0.731 0.743 0.740 0.733 82 1215 DELETED 0.746 0.731 0 '43 0.740 0.733 83 1230 DFLETED 0.746 0.731 0.743 0.740 0.733 84 1245 DELETED 0.746 0.730 0.743 0.740 0.733 85 1260 DFLETED 0.746 0.731 0.743 0.740 0.733 86 1275 DELETED 0.746 0-731 0.743 0.741 0.733 87 1290 DELETED 0-746 0.731 0.744 0.740 0.733 88 1305 DELETED 0-746 0.731 0.743 0.741 0.734 89 1320 DELETED 0.746 0.731 0.743 0.740 0.734 90 1335 DELETED 0.746 0.731 0.744 0.740 0.734 91 1350 DEr ETED 0.746 0.731 0.743 0.740 0.733 92 1365 DELETED 0.746 0.731 0.743 0.740 0.734 93 1380 DELETED 0.746 0.731 0.744 0.740 0.734 94 1395 DELETED 0.746 0.731 0.744 0.741 0.734 95 1410 DELETED 0.746 0.731 0.744 0.741 0.734 96 1425 D"LETED 0.746 0.731 0.744 0.740 0.734 97 1440 DELETED 0.746 0.731 0.743 0.740 0.734 END OF TABLE
VARIABLE TABLE
SUMMARY
SAYiPLE DELTA HUM 8 HUM 9 HUM 10 NUMBER MINS FRACTION FRACTION FRACTION 1 0 0.790 0.803 0.783 2 15 0.790 0.803 0.780 3 30 0.791 0.802 0.780 4 45 0.790 0.800 0.778 5 60 0.790 0.800 0.777 6 75 0.788 0-800 0.776 7 90 0.788 0.798 0-774 8 105 0.787 0.798 0.771 9 120 0.786 0.798 0.770 10 135 0 ~ 784 0.796 0.769 ll 12 150 165 0.785 0.784 0.796 0.795 0.767 0.768 13 180 0.783 0.794 0.766 14 195 0.784 0.793 0.765 1 0 210 0.783 0.793 0.764 16 225 0.780 0.792 0.762 17 240 0.779 0.791 0.763 18 255 0.773 0.791 0.765 19 270 0.771 0.789 0.766 20 285 0.768 0.787 0.764 21 300 0.769 0.784'.784 0.764 22 315 0.766 0.762 23 330 0.764 0.784 0 ~ 762 24 345 0.763 0.784 0.762 25 360 0.763 0.782 0 ~ 762 26 375 0.762 0.780 0.761 27 390 0.762 0.778 0 ~ 761 28 405 0.762 0.777 0.761 29 420 0.762 0.777 0.761 30 435 0.762 0.775 0.761 31 450 0.761 0. 775. 0.761 32 465 0.761 0.775 0.761 33 480 0.761 0.774 0.760 34 495 0.761 0.774 0 ~ 761 35 510 0.761 0.773 0.760 36 525 0.761 0.773 0.761 37 540 0.761 0.773 0-760 38 555 0.761 0. 173 0.761 39 570 0. 761 0.773 0.761 40 585 0.760 0.773 0.761 41 600 0-761 0.773 0.761 42 615 0.761 0.772 0 761
~
43 630 0.760 0.772 0.761 44 645 0.761 0.772 0.760 45 660 0.760 0.772 0.760 46 675 0.760 0.772 0.761 47 690 0.760 0.772 0.760 48 705 0.760 0.772 0.760 49 720 0.760 0.772 0.761 50 735 0 ~ 760 0.772 0.760
VARIABLE TABLE
SUMMARY
(CONTINUED)
SAMPLE DELTA HUM 8 HUM 9 HUMi 10 NUMBER MINS FRACTION FRACTION FRACTION 51 750 0.760 0.771 0.760 52 765 0 '60 0.771 0.760 53 780 0.760 0.771 0.760 54 795 0.760 0.771 0.760 55 810 0 '60 0.771 0.761 56 825 0.760 0.771 0.760 57 840 0.760 0.771 0.760 58 855 0 '60 0.771 0.761 59 870 0.760 0.771 0.760 60 885 0.760 0.771 0.760 61 900 0.760 0.771 0.760 62 915 0 '60 0.771 0.761 63 930 0.760 0.771 0.760 64 945 0.760 0.771 0.760 65 960 0 '60 0.771 0.760 66 975 0.760 0.771 0.760 67 990 0.760 0.770 0.760 68 1005 0.760 0.770 0.760 69 1020 0.760 0.771 0.760 70 1035 0 '60 0.771 0.760 .
71 1050 0.760 0.770 0.760 72 1065 0.760 0.770 0 '60 73 1080 0.760 0.770 0.761 74 1095 0.760 0.770 0.760 75 1110 0.759 0.770 0.760 76 1125 0.759 0.770 0.760 77 1140 0.760 0.770 0.760 78 1155 0.759 0.770 0.760 79 1170 0.759 0.770 0.760 80 1185 0.759 0.770 0.760 81 1200 0 '60 0.770 0.760 82 1215 0.759 0.770 0.760 83 1230 0.759 0.770 0.760 84 1245 0.759 0.770 0.760 85 1260 0.759 0.770 0.760 86 1275 0.759 0.770 0.760 87 1290 0.759 0.770 0.760 88 1305 0.759 0.769 0-761 89 1320 0.759 0.770 0.760 90 1335 0.759 0.770 0.760 91 1350 0.759 0.769 0.759 92 1365 0.759 0.769 0.759 93 1380 0.760 0.770 0.760 94 1395 0.759 0.769 0.760 95 1410 0.759 0.770 0.760 96 1425 0.760 0 '69 0.760 97 1440 0.759 0-769 0.760 END OF TABLE
734320.
7 ~ 33 CONTRINMENT RIR MASSES flIR MASS 81 '7 '3 ~
FITTED AIR t!RSS m 734160.
CQ 734000.
CC 733840.
DJ 733680.
C7 C.3 733520. 240. 480. 720. 9SO. 1200. 1440. 1680.
0 2400 17 ~ 33 ~
COMPUTED LERK RRTES 65 ~ 81 '7 113.
SIMPLE NRSS POINT LEAK RATE 00 00 FITTED HRSS PO IHT LEAK RRTE Cl X
Cl CJ 0
CZ EC n 5 Cl 0.0800 CJ lo al w 0.0000
-0.0800
-0.1600 0 ~ 240. 480. 720. 960. 1200. 1440. 1680.
TINE IN MINUTES
1.8000 17 '3 COMPUTED LERK RRTES
~
RELRTIVE TO LIMITS FITTED NRSS POINT LERK RATE 81 '7 113 ~
95% CONFIDENCE L I I I T ( VCL )
DESIGN BASIS LEAKAGE RRTE NRC NRXINVN ALLOHRBLE LERKRGE RRTE 1.2ooa 0-ca 0-0.9000 o.6ooo a.3ooo 0.0000 480. 1680.
240. 720. 960. 1200. 1440 TINE IN MINUTES
7 ~ 33- 65 '1 '13.
VOLUMETRICRLLY WEIGHTED CONTRINMENT TEMPERRTURE 85.0000 84.8000 84.6000 84.4000 84.2000 0 240. 480. 720. 960. 1200. 1440. 1680.
TINE IN NINVTES
59.7100 17- 33 ~
RVERRBE CONTR I NNENT PRE55URE 81 '7 113.
CZ 0
59.6900 DJ 59.6700 (Q
Q 59 6500
~
59 6300 59 6100 0 4 240. 480. 720. 960. 1200. 1440 ~ 1680.
TINE IN MINUTES
17 ~ 33 ~ 81 ~ 97 113.
0.44SO- VOLUNETR I CRLLY WE I GHTEO VRPOR PRESSURE 5
0.4440 aal I
I EJ 0
CC 5
CI 0.4420 sal vJ CL CI Eb
~4 CI 0.4400 0.4380 0.43SO 240. 480. 720. 9SO. 1200. 1440. 1S80.
TINE IN MINUTES
FLORIDA POWER 6 LIGHT COMPANY ST LUCIE PLANT UNIT itO. 2 CONTAINMENT INTEGRATED LEAKAGE RATE TEST SUPPLEMENTAL VERIFICATION TEST LEAKAGE RATE MEASURED USING THE ABSOLUTE METHOD LEAKAGE RATE COMPUTED USING THE MASS POINT METHOD TEST PERIOD STARTED AT 1330 HOURS ON DECEMBER 1, 1982 TEST CONDUCTED FOR 4.25 HOURS FREE SPACE VOLUME OF CONTAINMENT IS 2500000 CU FT CONTAINMENT WAS PRESSURIZED TO 59.61 PSIA INITIAL VERIFICATION AIR WEIGHT 733796.8 LBS FINAL VERIFICATION AIR WEIGHT 733428.7 LBS FITTED MASS POINT LEAKAGE RATE IS 0-279 % PER DAY LC = 0.279 LAM = 0.024 LO = 0.267 LO + LAMi 0.25 LA < LC' LO + LAM + 0.25 LA 0 '67 + 0 '24 0.125 < 0.279 < 0.267 + 0 '24 + 0.125 0.166 < 0.279 < 0.416 LC =FITTED CLRT MASS POINT LEAKAGE RATE LAM =FITTED ILRT MASS POINT LEAKAGE RATE LO =SUPERIMPOSED LEAKAGE DURING VERIFICATION TEST LA =NRC MAXIMUM ALLOWABLE LEAKAGE RATE
DESCRIPTION OF VARIABLES AVG. TEM CONTAINMiENT MEAN TEMPERATURE CALCULATED FROM VOLUMETRICALLY WEIGHTED RTD SENSOR INDICATIONS.
AVE PRE- PRIMARY CONTAINMiENT PRESSURF INDICATION.
VAP. PRE CONTAINMENT VAPOR PRESSURE CALCULATED FROM VOLlJMETRICALLY WEIGHTED RHD SENSOR INDICATIONS.
LEAK SIMi SIMPLE TOTAL TIME LEAKAGE RATE.
LEAK MAS LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSlON OF AIR MASS DATA.
AIR MASS CONTAINMENT AIR MASS.
NOTE FOR TABULAR DATA TABLE VALUES OF ZERO SIGNIFY EITHER.
- 1. DATA IS NOT APPLICABLE TO THE CALCULATION OR
- 2. SENSOR HAS BEEN DELETED FROM THE SCAN.
NOTE FOR CURVES
- 1. TOP ABSCiSSA SCALE REPRESENTS SAMPLE NUMBERS.
- 2. AXR MASS IS THE CALCULATED CONTAINMENT AIR MASS AND FXTTED AIR MASS IS THE LINEAR LEAST SQUARE FIT OF THE AIR MASSES.
- 3. SIMPLE MASS POINT IS THE TOTAL TIME LEAKAGE RATE AND FITTED MASS POINT IS THE LEAKAGE RATE COMPUTED FROM FIRST ORDER REGRESSION OF AIR MASS DATA.
- 4. UCL IS THE UPPER LIMIT OF THE 95%
CONFIDENCE LEVEL OF AIR MASS DATA.
VARIABLE TABLE
SUMMARY
SAMPLE DELTA AVG. TEM AVG. PRE VAP. PRE LEAK SIM LEAK MAS AIR MASS NUMBER MINS DEG. F PSIA PSIA PER CENT PER CENT POUNDS 1 0 84-383 59.6060 0.4374 0.000 0.000 733797 2 15 84.387 59.6040 0.4374 0.418 0 000 F 733765 3 30 84.384 59.6020 0.4373 0.330 0.330 733746 45 84.384 59.6010 0.4374 0.279 0.276 733733 60 84.383 59.5990 0.4373 0.284 0.269 733710 6 75 84.380 59.5970 0.4374 0.284 0.269 733688 7 90 84.378 59.5950 0.4372 0.279 0.268 733669 8 105 84.379 59.5930 0.4373 0.289 0.274 733642 9 120 84.377 59.5910 0.4373 0.289 0.278 733620 10 135 84.374 59.5900 0.4372 0.269 0.271, 733612 ll 12 150 165 84.375 84.376 59.5880 59-5860 0.4372 0.4373 0.276 0.283 0.270 0.273 733586 733559 13 180 84.377 59.5840 0.4372 0.286 0.276 733534 14 195 84.376 59.5820 0.4373 0.289 0.279 733510 15 210 84.374 59.5810 0.4372 0.277 0.277 733501 16 225 84.376 59.5790 0.4373 0.283 0.278 733472 17 240 84-373 59.5770 0.4372 0 '82 0.278 733453 18 255 84.372 59.5750 0.4373 0.283 0.279 733429 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMiPLE DELTA TEHP 1 TEMP 2 TEMP 3 TEHiP 4 TEHP 5 TEMP 6 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG ~ F DEG. F 1 0 84.670 84.270 84,.580 84.110 84.120 84.060 2 15 84.670 84.290 84.580 84.110 84-120 84 '60 3 30 84.670 84.290 84.580 84.120 84.120 84.070 4 45 84'660 84.290 84.580 84.110 84.120 84.070 5 60 84.660 84.290 84.590 84.120 84.130 84.080 6 75 84.670 84.280 84.590- 84.120 84.130 84.070 7 90 84.670 84.280 84.580 84.110 84.130 84.070 8 105 84.670 84.280 84.590 84.120 84.140 84.070 9 120 84.670 84.280 84.580 .84.130 84.140 84.070 10 135 84.670 84.280 84.590 84.130 84.140 84.070 11 150 '4.670 84.280 84.580 84.130 84.140 84 080
~
12 165 84.670 84.280 84.580 84.140 84.150 84.080 13 180 84.680 84.280 84.590 84.140 84.150 84.090 14 195 84 '80 84.280 84.590 84.140 84.150 84.090 15 210 84.680 84.280 84.600 84.140 84.160 84.090 16 225 84.680 84.280 84.600 84.140 84.160 84.090 17 240 84.680 84.280 84.600 84.140 84.150 84.090 18 255 84.670 84.280 84.600 84.140 84.150 84.090 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 7 TEMP 8 TEMP 9 TEMP DEG.
10 F
TEMP DEG.
ll F
TEMP DEG.
12 F
NUMBER MENS DEG. F DEG. F DEG. F 1 0 84.730 84.310 84.170 84.420 84.230 82.140 2 15 84.730 84.320 84.170 84.410 84.240 82.150 3 30 84.730 84.320 84.170 84.420 84.250 82.150 4 45 84.730 84.320 84.160 84.410 84.230 82.140 60 84.730 84.320 84.160 84.410 84.240 82.150 6 75 84.730 84.330 84.160 84.410 84.230 82.150 7 90 84.730 84.320 84.150 84.410 84.230 82.160 8 105 84.730 84.330 84.150 84.400 84.230 82.140 9 120 84.730 84.340 84.140 84-390 84.230 82.140 10 135 84.730 84.330 84.150 84.390 84.220 82.140 ll 12 150 165 84.730 84.740 84.330 84.330 84.140 84.150 84.390 84.400 84.220 84.230 82.140 82.140 13 180 84.740 84.330 84.140 84.400 84.230 82.130 14 195 84.740 84-350 84.150 84-390 84.220 82.140 15 210 84.740 84-350 84.150 84.400 84.220 82.140 16 225 84.740 84.350 84.140 84.390 84.230 82.150 17 240 84.740 84.350 84.140 84.390 84.210 82.130 18 255 84.780 84.340 84.140 84.390 84.200 82.120 END OF TABLE
VARIABLE TABLE SUMYiARY SAMPLE DELTA TEYiP 13 TEMP 14 TEMP 15 TEYiP 16 TEMP 17 TEMP 18 NUMBER MINS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 84.350 84.180 84.470 DELETED 84.370 84.250 2 15 84.340 84.180 84.470 DELETED 84.360 84.250 3 30 84.340 84.180 84.470 DELETED 84-370 84.250 4 45 84.340 84.170 84.470 DELETED 84.370 84.250 5 60 84.330 84.180 84.470 DELETED 84.370 84.260 6 75 84.330 84.170 84.470 DELETED 84-360 84.250 7 90 84-330 84.160 84.460 DELETED 84.360 84.250 8 105 84.330 84.170 84-450 DELETED 84-360 84.240 9 120 84.330 84.170 84-460 DELETED 84.360 84.240 10 135 84.320 84 '60 84.460 DELETED 84.350 84.250 11 150 84.320 84.160 84.460 DELETED 84.360 84.240 12 165 84.320 84.160 84.450 DELETED 84.360 84.240 13 180 84.310 84.160 84.450 DELETED 84.360 84.240 14 195 84.320 84.160 84.450 DELETED 84.360 84.240 15 210 84.320 84.160 84.450 DELETED 84.360 84.240 16 225 84.320 84.160 84.450 DELETED 84.360 84.240 17 240 84.310 84.160 84.450 DELETED 84.360 84.240 ls 255 84.310 84.160 84.440 DELETED 84.350 84.240 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA TEMP 19 TEMP 20 TEMP 21 TEMP 22 TEMP 23 TEMP 24 NUMBER MENS DEG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 84.510 81. 120 84-530 84.560 84.950 84.450 2 3 5 84.510 81.120 84.530 84.570 84.960 84.460 3 30 84.510 81.110 84.540 84.560 84.960 84.460 45 84.510 81.120 84.540 84.560 84 '60 84.460 5 60 84.500 81.110 84.530 84.570 84.960 84.450 6 75 84.510 81.110 84.520 84-560 84.950 84.460 7 90 84.510 81.110 84.530 84.560 84.950 84.450 8 105 84.500 81.110 84.540 84.'560 84.950 84.440 9 120 84.500 81.110 84.520 84.580 84.960 84.450 10 135 84.500 81.110 84-530 84.560 84.950 84.440 ll 12 150 165 84.500 84.500 81.110 81.110 84.510 84.500 84 '50 84.560 84.950 84.960 84 '60 84.450 13 180 84.500 81.110 , 84.520 84.550 84.950 84.450 14 195 84.500 81.110 84.530 84.560 84.940 84.440 15 210 8.4. 500 81.100 84.510 84.550 84.940 84.440 3.6 225 84.500 81.100 84.520 84.560 84.940 84.440 17 240 84.500 81-100 84.530 84.550 84.930 84.440 18 255 84.500 81.100 84.540 84.550 84.960 84.440 END OF TABLE
VARIABLE TABLE
SUMMARY
SAHPLE DELTA T"HP 25 TEMP 26 TEMP 27 TEMP 28 TEMP 29 TEMP 30 NUMBER HIHS DFG. F DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 84.610 84.530 84 '80 84.840 84.250 83-760 2 15 84.610 84.540 84.590 84.840 84.250 83.760 3 "30 84-600 84.530 84.580 84.830 84.240 83-750 4 45 84.600 84.530 84.590 84.840 84.240 83.760 5 60 84.600 84.530 84.590 84.830 84.230 83.750 6 75 84.600 84.530 84.580 84.840 84 '30 83.750 7 90 84.590 84.520 84.580 84.840 84.230 83.750 8 105 84.600 84.530 84.580 84.830 84.230 83.740 9 120 84.600 84 '20 84.580 84.830 84.220 83.730 10 135 84.590 84.520 84.580 84.820 84.220 83.730 ll 12 150 165 84.590 84.590 84.520 84.520 84.590 84.590 84.830 84.830 84.220 84.220 83-740 83.740 13 180 84.600 84 '30 84.590 84.830 84.220 83.740 14 195 84.590 84.530 84.590 84.830 84.210 83.730 15 210 84.580 84.520 84.590 84.830 84.220 83-740 16 225 84.590 84.520 84.590 84.830 84.220 83-740 17 240 84.590 84.520 84.590 84.830 84.220 83-740 18 255 84.590 84.520 84.580 84.820 84.210 83 '40 END OF TABLE
VARiABLE TABLE
SUMMARY
SAMPLE DELTA EMP 31 TEMP 32 TEMP 33 TEMP 34 TEMP 35 TEMP 36 NUMBER HiNS DEG. DEG. F DEG. F DEG. F DEG. F DEG. F 1 0 DELETED 84.260 84.110 84.210 84.190 84.470 2 15 DELETFD 84.270 84.110 84 '80 84.190 84.490 3 30 DELETED 84.260 ~
84.100 84.260 84.180 84.470 45 DELETED 84.260 84.100 84.280 84.180 84.470 5 60 DELETFD 84.260 84.100 84.270 84.180 84.460 6 75 DEL ETED 84.250 84.100 84.260 84.180 84.460 7 90 DELETED 84.250 84.090 84.270 84.150 84.460 8 105 DFLETED 84.250 84-100 84.270 84.180 84.450 9 120 DELETED 84.250 84.090 84.270 84.170 84.450 10 135 DELETED 84-250 84.090 84.260 84.170 84.450 11 150 DELETED 84-250 84.090 84.270 84.170 84.450 12 165 DELETED 84-250 84.090 84.260 84.180 84-450 13 180 DELETED 84.250 84.090 84.280 84.170 84.450 14 195 DELETED 84.240 84.080 84.260 84.160 84.450 15 210 DELETED 84.240 84.080 84.260 84.150 ~
84.450 16 225 DELETED 84.240 84.080 84.270 84.150 84.450 17 240 DELETED 84.240 84.080 84.250 84.160 84-450 18 255 DFLETED 84-230 84.070 84.260 84.160 84.440 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DEi TA TEMP 37 TEMP 38 TEMP 39 TEMP 40 PRES 1 HUM 1 NUMBFR MINS DEG. F DEG. F DEG. F. DEG. F PSIA FRACTION 1 0 84.200 84.620 83 '60 84.120 59.606 0.734 2 15 84.210 84.620 83.870 84.120 59 '04 0.734 3 30 84.210 84.610 83.830 84.110 59.602 0.734 45 84.200 84.610 83 '70 84.120 59.601 0.734 5 60 84.190 84.620 83.850 84.100 59.599 0.734 6 75 84.190 84.620 83.830 84.100 59.597 0.734 7 90 84.190 84.590 83.850 84-120 59.595 0.734 8 105 84.200 84.620 83.840 84.100 59.593 0.734 9 120 84.180 84.600 83.840 84.090 59.591 0.735 10 135 84 '90 84.590 83.840 84 '90 59.590 0.734 ll 12 150 165 84.180 84.190 84.600 84.600 83.830 83.830 84.100 84.090 59.588 59.586 0.734 0.735 13 180 84.190 84.590 83.820 84.100 59.584 0.734 14 195 84.180 84.600 83.820 84.100 59.582 0.734 15 210 84.180 84.590 83.800 84.080 59.581 0.735 lQ 225 84.180 84.590 83-830 84.090 59.579 0.735 17 240 84.190 84.590 83.790 84.090 59.577 0.735 18 255 84.170 84.580 83.820 84.080 59.575 0.735 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 2 HUM 3 HUM 4 HUM 5 HUM 6 HUM 7 NUMBER MINS FRACTION FRACTION FRACTION FRACTION FRACTION FRACTION 1 0 DELETED 0.746 0.731 0.744 0.741 0.734 2 15 DELETED 0.745 0 '31 0.744 0.741 0.734 3 30 DELETED 0.746 0.731 0.744 0.740 0.734 45 DFLETED 0.745 0.731 0.744 0.740 0.734 5 60 DELETED 0.746 0 '32 0.743 0.741 0.734 6 75 DELETED 0.745 0.731 0.744 0.740 0.734 7 90 DELETED 0.745 0.731 0.743 0.740 0.734 8 105 D"LETED 0.746 0.731 0.744 0.741 0.734 9 120 DELETED 0.745 0.732 0.744 0.741 0.734 10 135 DELETED 0.745 0.732 0.743 0.741 0.734 J 1 150 DELETED 0.745 0.732 0.744 0.741 0.734 12 165 DELETED 0.746 0.731 0.744 0.741 0.733 13 180 DELETED 0.745 0.731 0.744 0.741 0.734 14 195 DELETED 0.746 0.732 0.744 0.741 0.734 15 210 DELETED 0.746 0.731 0.744 0.741 0 '34 16 225 DELETED 0.746 0.732 0.744 0.741 0.734 17 240 DELETED 0.746 0.732 0.743 0.741 0.734 18 255 DELETED 0.746 0.732 0.744 0.741 0.734 END OF TABLE
VARIABLE TABLE
SUMMARY
SAMPLE DELTA HUM 8 HUM 9 HUM 10 NUMBER MINS FRACTION FRACTION FRACTION 1 0 0.759 0.769 0.760 2 0.759 0.770 0.760 3 30 0.759 0.769 0.759 45 0 '59 0.769 0.760 60 0.759 0.769 0.760 6 75 0.760 0.769 0.760 7 90 0 '59 0.769 0.760 8 105 0.759 0.769 0 '60 9 120 0.759 0 '69 0-760 10 135 0.759 0.769 0-760 ll 12 150 165 0.759 0.759 0.769 0.769 0.760 0.760 1 180 0.759 0.769 0.760 14 195 0 '59 0-769 0-760 15 210 0.759 0.769 0-760 16 225 0.759 0.769 0.760 17 240 0 '59 0 '69 0.760 18 255 0.759 0.769 0.760 END OF TABLE END OF REPORT ON CONTAINMENT LEAK RATE TEST TO NRC
9 ~ 17 '
733920. CONTRINNENT RIR NRSSES RIR HRSS FITTED RIR NRSS Ol CI 5
I O
Cl I
CI 733720.
lal CC 733620.
UJ 733520.
C3 733420. 4 60 '20. 180. 240. 300. 360. 420.
TINE IN MINUTES
9 ~ 17 ~ 21 0.5000 CONPlJTED LERK RRTES SIMPLE NRSS POINT LERK RRTE FITTED NRSS POINT LERK RRTE 0.4500 0-CC Cl 0.4000 QJ CL 0.3500 0 3000 0 2500 4 60 '20. 180. 240. 300. 360. 420.
TIME IN MINUTES
9 ~ 17 ~
0.6000 COMPUTED LERK RRTES RELRTIVE TO LIMITS F I TTEO CLRT l1RSS POINT LEAKAGE RATE r
NRXINUN RCCEPTRBLE N 04 MINIMUMS RCCEPTRBLE 5
0.5000 I
I Cl 0- CJ CC n 5 0.4000 sd O
0.3000 0.2000 60 '20. 180. 240. 300. 360 420 TIME IN MINUTES
5 ~ 9 ~ 17 ~
29 84.3950 tj'OLUMETR ICRLLY WE I GHTEI3 CONTR INMENT TEMPERRTURE c
cv 04 CI 5
84.3900 W
I I
CI 4
CJ (Q
UJ Lit 84.3850 8 CL W LQ ul C) CI O
84.3800 X'4.3750 84.3700 4 60 '20. 180. 240. 300. 360. -420 ~
TINE IN MINUTES
0 1s 5 ~ 9 ~ 17 ~ 1 ~ 29 I $
RVERRBE CQNTRINMENT PRESSURE '9.6150 CC V3 0
59.6070 CJ
~4 CL CC CL 59.5990 59.5910 59.5830 59.5750 0 60 '20. 180- 240 ~ 300. 360. 420.
TINE IN MINUTES
0 9 ~ 7 ~ Pl ~
)5 ~ 9 ~
0.4376 VOLUNETRICRLLY WEIGHTED VAPOR PRESSURE cv Ol CS 0.4375 I
I CI
~4 1d C 5
CI 0 4374 U3 Fl Ld Ch aJ CL O CS 0.4373 CC 0.4372 0.4371 0 60 '20. 180. 240. 300. 360. 420.
TINE IN MINUTES