PLANT SYSTEMS 3 4.7.6 FLOOD PROTECTION LIMITING CONDITION FOR OPERATION 3.7.6.1 Flood protection shall be provided for the facility site.

APPLICABILITY: At al 1 times.

ACTION:

With either a Hurricane Watch or a Hurricane Warning issued for the facility site, perform the St. Lucie Plant Beach Survey Procedure pursuant to Specification" 4.7.6.1.1 below.

SURVEILLANCE RE UIREMENTS

4. 7. 6. 1. 1 The St. Lucie Plant Beach Survey Procedure shall be conducted at least once per year between the dates of May 25 and June 7 and within 30 days following the termination of either a Hurricane Watch or a Hurricane Warning for the facility site.

A Special Report containing the results of these surveys shall be prepared and submitted to the Commission pur-suant to Specification 6.9.2 within 30 days following the completion of the survey.

The Special Report shall include an evaluation of the facility flood protection if, as evidenced by this survey program, the beach dune described in Specification

5. 1.3 is lost.

4.7.6.1.2 The St. Lucie Mangrove Photographic Survey Procedure shall be conducted at least once per 12 months and shall be a color infrared photograph(s),

or equivalent, of the mangrove area between the facility and the FPSL east property line.

The results of these surveys shall be included in the Annual Operating Report for the period in which the survey was completed.

This report shall include an evaluation of the facility flood protection if the survey indicates deterioration, either man-made or natural, of this mangrove area.

4.7.6. 1.3 Meteorological forecasts shall be obtained from the National Hurricane Center in Miami, Florida at least once per 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> during either a.Hurricane Watch or a Hurricane Warning.

a300 I 8204 87I ".820409 I PDR ADGCK 05000335

", P,'

P.DR,

~i" p.,'/4 7-19 4-9-82

c'

STATE OF FLORIDA

)

)

COUNTY OF DADE

)

ss J.

W. Williams, Jr.,

being first duly sworn, deposes and says:

That he is Vice President Lignt Company, the herein;

~of Florida Power That he has executed the foregoing document; that the state-ments made in this said document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said J.

W. Williams, Jr.

Subscribed and sworn to before me this day of

r. ~

'NOTARY, PUBLIC, in and for the County of Dade, State of Florida Notary Public, State of Rorida at Large M

Commiss o E pires October 30,.1983 g ncy

OO ag

( ~ f gl F

cr P

l' t>>