APPENDIX A NOTICE OF VIOLATION Florida Power and Light Company St.
Lucie 1
Docket No. 50-335 License No.
DPR-67 As a result of the inspection conducted on October ll - November 24, 1981 and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980),
the following violation was identified.
Technical Specification 6.8. l.c requires that written procedures shall be established, implemented and maintained covering surveillance and test activities of safety-related equipment.
Contrary to the above, the surveillance procedure for local leak rate testing of containment isolation valves was inadequate in that the procedure did not always provide an atmospheric vent path downstream of the valve under test, did not provide for demonstration that other pressure sources which could affect the test were in fact isolated and not leaking into the test area, and did not address-all valves requiring alignment in order to conduct a
valid test.
This is a Severity Level V Violation (Supplement I.E.).
Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, i'ncluding:
(1) admission or denial of the alleged viola-tion; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.
Consideration may be given to extending your response time for good cause shown.
Under the authority of Section 182 of the Atomic Energy Act of
- 1954, as
- amended, this response shall be submitted under oath or affirmation.