Responds to NRC Re Violations Noted in IE Insp Rept 50-335/81-31.Corrective Actions:Qc Inspectors Reinstructed in Requirements for Hanger Insps & Review Conducted of Anchor Bolts in Backfit Stores
ML17212B362
Person / Time
Site: Saint Lucie 
Issue date: 01/13/1982
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17212B361 List:
References
L-82-14, NUDOCS 8202050427
Download: ML17212B362 (6)


Text

USNRC REGION:.'TI hHTA, OI:.OR "Il'P.JQlo F'l: 5.

P.O. BOX 529100 MIAMI,FL 33152 gyle~

Q

)A FLORIDA POWER & LIGHTCOMPANY January 13, 1982 L-82-14 Mr. James P. O'Reil ly, Regional Administrator, Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

Re:

St. Lucie Unit 1

Docket No. 50-335 J

8 Florida Power 8 Light Company has reviewed the subject inspection report and a response is attached.

There is no proprietary information in the report.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8 Technology REU/PLP/ras cc:

Harold F. Reis, Esquire 8202G50427 820gg7 PDR ADOCK 05000335 PDR~

PEOPLE... SERVING PEOPLE

1 n

r

ATTACHMENT RE.

ST.

LUCIE UNIT 1 DOCKET NO. 50-335 IE INSPECTION REPORT 81-31 FINDINGS 10 CFR 50, Appendix B

Criterion V requires that activities affecting quality shall be pr escr ibed by documented instructions, procedures or drawings and accomplished in accordance with these instructions procedures and drawings.

1.

Florida Power and Light Company guality Instruction 10.23, Revision I, paragraph 4.3.5, requires that expansion anchors shall be seated to at least the minimum embedment depth as noted in the manufacturers instructions, or applicable design document; EBASCO specification FLO 9110-AS-13 Table 4.03( 1) requires a

minimum embedment depth of 6.5 inches for 3/4 inch diameter expansion anchor bolt.

Contrary to the above.

the 3/4 inch diameter expansion anchor bolts for pipe restraint CH-3-10A were installed, inspected and gC accepted with an embedment depth of appoximately 2 1/2 inches.

2.

Florida Power and Light Company equality Instruction

10. 14, paragraph
5. 2.3. 4, requires gC verification that the pipe hanger assembly is i n accordance with approved drawings.

Contr ary to the

above, gC inspected and accepted pipe hanger CCH-169 was not in accordance with approved detail drawing in that it had a

fastener arrangement that differed from the arrangement required by the detailed drawing.

RESPONSE

1.

FPL concurs with the findings.

2.

These findings were caused by personnel error.

3.

As corrective

action, non-conformance reports were issued for these
items, and they were properly dispositioned.

4.

As corrective action to prevent future

problems, quality control inspectors have been reinstructed in the requir ements for hanger inspections.

In addition a

review was conducted of anchor bolts in backfit stores for proper length.

Anchor bolts 3/4" by 5 1/2 have been determined unsuitable for use at this time.

A review of plant changes using the 5

1/2" anchor bolts was conducted.

This review identified potential problems in two additional hangers.

These potential problems have been properly dispositioned.

5.

Full compliance was achieved January 7, 1982.

j

~

~

'I

~

STATE OF FLORXDA

)

. )

COUNTY OF DADE

)

SS

~

Robert E. Uhhi being first duly sworn, deposes and says:

That he is Vice President of Florida Power Light Company, the herein; That he has executed the foregoing document; that the state-ments made in this said document are true and correct to the best of his knowledge., information, and belief, and that he is authorized to execute the document on behalf of said Robert E. Uhrig Subscribed and sworn to before me this 3

day of I

J 19~/

~NOTARY'PUBLIC, 'nd for the County of Dade, State of Florida

'I Notary Public, State of Florida at Large My CommMiion Expires October 30, 1983 My COmmiSSiOn eXpireS-,

M nerd Bondin Aoen

I

~

~

~

V L /

('-

lL t'g

~r h