EMERGENCY PROCEDURE 2-0030132 Rev 0
& LIGHT COMPANY ST.
LlX:IE PIANT UNIT 2 EMERGENCY PROCEDURE NUMBER 2-0030132 REVISION 0 ANTICIPATED TRANSIENT WITHOUT SCRAM (AWS)
November 24, 1981 APPROVAL PLT MGR TOTAL NO.
OF PAGES 5
/.
PQQ ~g+ 8+0/08
~
8201 X3042i F
05000389 PDR
I I
ST. -LU:IE PIANT UNIT 2 EMERGENCY PROCEDURE NEER 2-0030132 (AVOWS) REVISION 0 1 ~ 0 SCOPE This procedure provides instructions to be used in the event of an ATWS-The transients which produce most limiting ATWS consequences are covered by this procedure.
2a 0 SYMPZ04MS The following are symptoms, related to the three transients, which would cause a reactor trip.
Any of these symptoms, not accompanied by insertion of all CEA's, are an indication of ATSW:
SYMPZOM TRIP SIGNAL GENERATED BY:
STUCK LOP LOOP 0 PEN PORV INDICATION/ALARM 2.1 High Przr Pressure Yes Yes No
2.2 TMh.P No No Yes
- 2. 1 Alarms L-20, L-28 2.2 Indications PIA-1, 102A, PIA-1 102B, PIA-1102C, PIA-1102D RPS - Channel 4
EMERGENCY PROCEDURE NUMBER 2-0030132 REVISION 0
ATWS ATWS
- 2. 0 SYMPTOMS:
(Cont. )
TRIP SIGNAL GENERATED BY:
STUCK LOF 2.3 Low RCS Flow Yes Yes No
- 2. 3 Indications PDI<<1101A, PDI-1101B, PDI-1 101C, PDI-1 101D RPS - Channel 6
2.4 Low S/G Level Yes No No
- 2. 3 Alarms L-10, L-18 2.4 Indications LIC-9013A, LIC-9013B, LIC-9013C, LIC>>9013D LIC-9023A, LIC-9023B, LIC-9023C$ LIC-9023D LR-9011, LR>>9021 RPS Channel 7
- 2. 4 Alarms L-3, L-11
- 3. 0 AUT(MATIC ACTIONS:
Some of the followf.ng Automatic Actions will occur during the various transients with the absence of a reactor trip:
NOTE:
Any Automatic Actions that should occur and do not, must be manually initiated.
3.1 Turbine Trip 3.1 If reactor trip SHOULD HAVE occurred 3.2 APW Auto Start
- 3. 3 PORV Actuation 3.4 Main Steam Safety Valves Open 3.5 SBCS Actuation 3.6 Generator OCB's Open 3.2 5X S/G level, narrow range 3.3 RCS pressure 9 2400 PSIA 3.4 S/G pressure greater than 975 PSIG 3.5 Turbine Trip or High S/G pressure
4l
EMERGENCY PROCEDURE NUMBER 2-0030132 REVISION 0
ATWS ATllS 3.0 AUTCMATIC ACTIONS:
(Cont.)
3.7 SEAS and CIAS
- 3. 8 CSAS 3.7 RCS pressure 1600 PSIA Containment pressure 5 PSIG 3.8 Containment pressure 10 PSIG 4 ~ 0 IMMEDIATE OPERATOR ACTIONS HOTE:
Following steps do not necessarily need to be performed in order.
4.1 Trip Turbine 4-2 Ensure AFW Flow 4.3 Trip Reactor AHD IF CEA S DOH T DROP 4-4 Open RTB's AHD IF CPA S DON T IKOP 4~1 RTGB 201
- 4. 5 RTGB 204 4.6 Emergency Borate by opening MV 2514 and starting BA pumps 2A and 2B
- 4. 6 RTGB 205 4.7 Stop M/G sets either at M/G set or at breaker 2-40212 and 2-4051 1 4-8 Return to 2-0030130, Reactor Trip/
Turbine Trip, Immediate Operator Actions to determine type of transient and further action required.
4-7 Locally in RAB
S S
EMERGENCY PROCEDURE NUMBER 2-0030132 REVISION 0
ATMS Arws 5 ~ 0 SUBSE UENT ACTIONS:
I None 6 ~ 0 DISCUSSION:
Tris procedure starts and ends
~doric a transient.
For this reason, there is no subsequent action.
The last immediate action is to refer to the Reactor Trip/Turbine Trip procedure and from there determine the course of action to take.
7.0 REFERENCES
7.1 Memorandum from Frank Schroeder to Robert L. Tedesco, dated June 23, 1980 7.2 CE Emergency Procedure Guidelines, CEN-152
- 7. 3 St. Lucie O'I Off-Normal 03rereeiag Procedures 8 0 RECORDS R
UIRED:
8.1 Normal Log Entries 9 0 APPROVAL:
Reviewed by the FacQ.ity Review Group Approved by Plant Manager Rev
~
reviewed by Facility Review Group Approved by Plant Manager 19 19 19 19 "L A S T P A G E" EP 2-0030132 REV 0 TOTAL NOe OF PAGES 5