Forwards LER 81-021/03L-0
Date released: 01/25/2018 Download: ML17209B157


LER 81-021/03L-0:on 810424,during Normal Operation,Channel Mb Containment Pressure Detector Failed.Caused by Force Motor Burnout.Detector Replaced
ML17209B158
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 05/26/1981
From: Pace P
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17209B158 (2)
Forwards LER 81-021/03L-0
ML17209B156
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 05/26/1981
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17209B156 (2)