Forwards Updated LER 80-067/01X-1
Date released: 01/25/2018 Download: ML17209A615


Updated LER 80-067/01X-1:on 801130,discovered That Some Reactor Trip Breakers Would Not Trip on Undervoltage.Caused by Redundant Uv & Shunt Trip Devices Not Tripping or Tripping Sluggishly.Device Armature Realigned
ML17266A394
Person / Time
Site: Saint Lucie 
Issue date: 01/16/1981
From: Pace P
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17266A394 (2)
Forwards Updated LER 80-067/01X-1
ML17209A614
Person / Time
Site: Saint Lucie 
Issue date: 01/16/1981
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17209A614 (1)