h APPENDIX A NOTICE OF VIOLATION Florida Power and Light Company St. Lucie License No. DPR-67 T

Based on the NRC inspection April 8 through ll, 1980, certain of your activities were apparently not conducted in full compliance with NRC requirements as indica-ted below.

These items have been categorized as described in correspondence to you dated December 31, 1974.

A.

As required by Criterion V of Appendix B to 10 CFR 50 and as implemented by Section 5.0 of the FPL Topical Quality Assurance Report, "Activities affecting quality shall be prescribed by documented instructions, procedures, drawings...

and shall be accomplished in accordance with these instructions, procedures and drawings".

Paragraph 5.4.3.1 of FPSL procedure QI 9 PR/PSL-2, the implementing Quality Instruction for the control of NDE, and paragraph 8 of ASNT SNT-TC-1A require a yearly eye examination for NDE personnel.

Contrary to the above, on April 11,

1980, NDE records revealed that for the site Ievel III examiner, an eye examination had not been administered within the required yearly time framers This is a deficiency.

80 07'0 7 0F~>