ML17206A929

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 76-06, Stress Corrosion Cracks in Stagnant,Low Pressure Stainless Piping Containing Boric Acid Solution at Pwrs, Which Was Omitted from IE Info Notice 79-19
ML17206A929
Person / Time
Site: Turkey Point, Saint Lucie  
Issue date: 07/18/1979
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
References
NUDOCS 7908030009
Download: ML17206A929 (2)


Text

~gg Rfgg In Reply Refer To:

RII:JPO 50-335, 50-389 50-250, 50-251

.. 8r-+ra zy UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTAST., N.W., SUITE 3100 ATLANTA,GEORGIA 30303 JUL 1 8 l979 I

+> O/A,g/

Plorida Power and Light Company Attn:

R. E. Uhrig, Vice President Advanced Systems and Technology P. 0, Box 529100 Miami, florida 33152 Gentlemen:

The attached enclosure, Circular 76-06, was inadvertently omitted in the July 17, 1979 issue of Information Notice 79-19.

Sincerely, James P. O'Reilly Director

Enclosure:

Circular 76-06 gg 08080O

~

~

q ~ 4

\\

Florida Poser nand Light Cocpany Plant Hanager Post Office Box 33450 Ft. Pierce, Florida Assistant gA Hanager Ft. Pierce, Florida Plant Manager H. E. Yaeger, 00 Post Office Box 01310 HiaNlq Florida 33]01