ML17200A085

From kanterella
Jump to navigation Jump to search

Request for Additional Information Regarding the Connection of Non-Seismic Boric Acid Recovery System to RWST Seismic Piping
ML17200A085
Person / Time
Site: Indian Point 
Issue date: 07/19/2017
From: Richard Guzman
Plant Licensing Branch 1
To: Robert Walpole
Entergy Nuclear Operations
Guzman R
References
CAC MF9578
Download: ML17200A085 (2)


Text

From:

Guzman, Richard To:

"Walpole, Robert W" Cc:

"Mirzai, Mahvash"; Danna, James

Subject:

Indian Point Unit No. 2 - Request for Additional Information re: Connection of Non-Seismic BARS to the RWST (CAC No. MF9578)

Date:

Wednesday, July 19, 2017 8:54:11 AM Mr. Walpole,

By letter dated April 7, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17104A039), Entergy Nuclear Operations, Inc. (Entergy),

submitted a license amendment request (LAR) for Indian Point Nuclear Generating Unit No.

2 (IP2). The amendment would revise Technical Specifications (TS) 3.5.4, Refueling Water Storage Tank (RWST), to allow for the temporary connection between the non-seismically qualified piping of the Boric Acid Recovery System (BARS) to the seismically qualified piping of the RWST for a limited period for filtration until the end of the spring 2018 refueling outage (2R23).

The Nuclear Regulatory Commissions (NRC) staff is reviewing your submittal and has determined that additional information is needed to complete its review. The specific request for additional information (RAI) questions are provided below. The RAI question was provided in draft form to you via e-mail on July 11, 2017. The draft question was sent to ensure that the question was understandable, the regulatory basis for the questions was clear, and to determine if the information was previously docketed.

By e-mail dated July 12, 2017, Ms. Mirzai of your staff stated that a conference call to discuss the draft RAIs was not needed; she indicated that Entergy would provide a response to the RAI questions within 30 days (which would be August 18, 2017).

If you have any questions, please contact me at (301) 415-1030. A copy of this e-mail will be made publicly available in ADAMS.

Thanks,

~~~~~~~~~

Rich Guzman Sr. PM, Plant Licensing Branch I Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Office: O-9C07 l Phone: 301-415-1030

REQUEST FOR ADDITIONAL INFORMATION

FOR PROPOSED LICENSE AMENDMENT REGARDING THE

CONNECTION OF NON-SEISMIC BORIC ACID RECOVERY SYSTEM

TO THE REFUELING WATER STORAGE TANK

ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING, UNIT NO. 2

DOCKET NO. 50-247

By letter dated April 7, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17104A039), Entergy Nuclear Operations, Inc. (Entergy),

submitted a license amendment request (LAR) for Indian Point Nuclear Generating Unit No.

2 (IP2). The amendment would revise Technical Specifications (TS) 3.5.4, Refueling Water Storage Tank (RWST), to allow for the temporary connection between the non-seismically qualified piping of the Boric Acid Recovery System (BARS) to the seismically qualified piping of the RWST for a limited period for filtration until the end of the spring 2018 refueling outage (2R23).

The NRC staff is reviewing your submittal and has determined that additional information is needed to complete its review. The specific information requested is addressed below.

According to the LAR, the non-seismic BARS will be connected to valve 725 through a 2-inch adapter plate which is on the discharge of the refueling water purification pump and is part of the RWST piping to the Spent Fuel Pool (SFP) purification loop.

If any portion of the non-seismic BARS ruptured, is there a possibility of water inventory loss in the SFP? Please explain in detail.