ML17195A044
| ML17195A044 | |
| Person / Time | |
|---|---|
| Site: | Dresden |
| Issue date: | 12/06/1983 |
| From: | Spessard R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Reed C COMMONWEALTH EDISON CO. |
| References | |
| NUDOCS 8312120275 | |
| Download: ML17195A044 (1) | |
Text
--_
- .** l
¥ Docket No. 50-237 Commonwealth Edison Company ATTN:
Mr. Cordell Reed Vice President
- Post Office Box 767 Chicago, IL 60690 DEC 6 rns3
SUBJECT:
DRESDEN NUCLEAR POWER STATION, UNIT 2 CONTAINMENT INTEGRATED LEAK RATE TEST FREQUENCY
References:
- 1.
Letter dated June 13, 1979, from B. B. Stephenson to H. R. Denton 2.. Letter dated July 7, 1983, from D. J. Scott to H. R. Denton Gentlemen:
We have reviewed the resul.ts of the Type A, B and. C leak rate tests submitted by References 1 and 2.
Our review indicates that the last two consecutive Type A tests at Dresden Unit 2 were failures and, pursua*nt to 10 CFR 50, Appendix J, Section III.A.6.(b), a Type A test should be performed during each plant shutdown for refueling.until two consecutive Type A tests 111eet the acceptance criteria of Appendix J.
Accordingly, unless you request and are granted an exemption from this requirement by NRR, we expect you to conduct a Type A tes.t during your upcoming refueling outage.
We will* gladly.discuss any questions you have concerning t.his matter.
Sincerely, r>
~~~=~*Q r:a:31212o~i75-e31206 PDR ADOCK 0500023.7 P
,.--~
.1 I
R. L. Spessard, Director Division of Engineering
- cc:
D. L. -Farrar,* Director
.:.of Nuclear Licensing D~ J. Scott, Station Superintendent DMB/Document Control Desk *,(RIDS)
Resident Inspector, Rill Phyllis Dunton, Attorney General's Office, Environmental Control Division Robert A. Gilbert, NRR Francis Jape, RI!
Walter R. Butler, NRR
~
- c==*--,_"='o-c~-=--"--~-~-~-, _ _,__
RIII 6?.$.a!
R~J..l;o RI~
lreYes/ld
~==-Walke.r. _
S~eter Spessard 12 / s/ 83 12 / ;J /B'f ~= -"
0 -=tcZ t.0,/ 8~ -~~ ____ 1:~ ~3=~-
0
-~ J~