Docket No. 50-249 Commonwealth Edison Company ATTN:

Mr. Cordell Reed Vice Pre.sident Post Office Box 767 Chicago, IL 60690 Gentlemen:

NOV 3 1983.

Thank you for you letter dated August 17, 1983, addressing a cont~rn expressed by members of my staff during a meeting on the Dresden.Statibn, Unit 3, Emergency Core Cooling System suction header snubber removal.

We understand that the calculations. attached to your letter,substantiate that allowable stresses.are not exceeded for the "no-snubber case 11 during a safe-shutdown earthquake.

We have no further que:;;tions at this time.

cc: D. L. Farrar~ Director of Nuclear Licensing D. J. S'tott, Station Superintendent cc w/ltr dtd 8/17/83:

DMB/Document Control Desk (RIDS)

Resident Inspector, RIII W.. G. Guldemond Phyllis Dunton, Attorney General's Office, Environmental Control Division

~

11/1/83--

RIII ~ii

&J*DJJ Walier Sincerely,

  • Original stgn~d.by W. o. Sh11fer" W. D. Shafer, Chief Projects Branch 2