TABLE 4.2.1 (Cont.)

NOTES:

7.

Fun*ctional tests will be conducted before startup at the end of each refueling. outage or after maintenance is performed on a particular Safety/Relief Valve.

8.

If the number of position indicators is reduced to one indication on one or more valves, continued operation is permissible; however if the reactor is in a cold shutdown condition for more than seventy-tWo hours, it may not be started up until all posit~on indication is restored.

In the event that all position indication is lost on one or more valves and such indication cannot be returned in thirty days, an orderly shutdown shall be initiated, and the reactor shall be depressurized to le*ss than 90 psig in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

45

TABLE 4.2.1 (Cont.)

DRP-25 NOTES:

7.

Functional tests will be conducted before startup at the end of each refueling outage or after maintenance is performed on a particular Safety/Relief Valve.

8.

If the number of position indicators is reduced to one indication.on one or more valves, continued operation is permissible; however if the reaGtOr is in a cold shutdown condition.for more than seventy-two hours, it may not be started up until all position indication is restored.

In the event that all position indication is lost on one or more valves and such indication cannot be returned in thirty days, an orderly shutdown shall be initiated, and the*reactor shall be depressurized to ~ess than.90 psig in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

45

Notes QUAo.:.cITIES DPR-29

l.

Instrument channels required during power operation to monitor postaccident conditions:

2:

Provisions are made for local sampling and monitoring of drywell atmosphere:

3.

In the event any of the instrumentation becomes inoperable for more than 7 days during reactor operation, initiate an orderly shutdown and be in the cold shutdown condition within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

4.

From and after the date that one of these parameters is reduced to one indication, continued operation is not permissible beyond thirty days unless such instrumentation is sooner made operable:

In the event that all "indication of these parameters is disabled and such indication cannot be restored in six (6) hours, an orderly shutdown shall be initiated and the reactor shall be in a cold shutdown condition in twenty-four (24) hours:

5.

If the number of position indicators is reduced to one indication on one or more valves, continued operation is permissible; however if the reactor is in a cold shutdown condition for more than seventy-two (72) hours, it may not be started up until all position indication is restored~

In the event that all position indicaion is lost on one br more valves and such indication cannot be returned in thirty days, an orderly shutdown shall be initiated; and the reactor shall be depressurized to less than 90 psig in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

3.2/4.2-l5a

QUAD-CITIES DPR-30 Notes I

.~.

1:

Instrument channels required during power operation to monitor postaccident conditions:

2.

Provisions are made for local sampling and*monitoring of drY.well atmosphere.

3.

In the event any of the instrumeAtation becomes inoperable for more than 7 days during reactor operati6n, initiate an orderly shutdown and be in the cold shutdown condition within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

4.

From and after the date that one of these parameters is reduced to one indication, continued operation is not permissible beyond thirty days unless such instrumentation is sooner made operable:

In the event that all indication of these parameters is disabled and such indication cannot be restored in six (6) hours, an orde.~ly shutdown shall be initiated and the reactor shall be in a cold shutdown conditio~ in twenty~four (24) hours:

5.

If the ~umber of position indicators is reduced to one indication on one or more valves~ continued operation is permissible; however "if the reactor is in a cold shutdown condition for more than seventy~two (72) hours, it may not be started up until all position indication is restored.

In the event that all position indicaion is lost on one or more valves and such indication cannot* be returned in thirty days, an orderly shutdown shall be initiated, and the reactor shall be depressurized to.less than 90 psig in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

3.2/4.2-15a