Appendix A NOTICE OF VIOLATION Commonwealth Edison Company Docket No. 50-237 As a result of the inspection conducted from June 6 through July 2, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violation was identified:
Technical Specification 3.7.A.1 requires that suppression pool water volume be maintained between a maximum of 115,655 cubic feet (-1.5 inches indicated) down to a minimum of 112,000 cubic feet (-5.0 inches indicated).
This is also in precautions and limits in HPCI Test Procedure DOS 2300-6 and ADS Test Pro-cedure DOS 250-5.
Contrary to the above, on May 11, 1981, while testing HPCI and ADS systems on Unit 2, the suppression pool (TORUS) level was allowed to rise to 1.5 inches indicated.
This is 3.0 inches in excess of the allowable level and was reduced to within the L.C.O. within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> upon discovery.
This is a Severity Level V violation (Supplement 1).
Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:
(1) cor-.
rective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.
Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.
Consideration may be given to extending your response time for good cause shown.
Dated iJUL 3' o' 1is'st R. F. Heishman, Ac {ng Director Division of Resident and Project Inspection 8108170389 810730 PDR ADOCK 05000010 Q