ML17194A063

From kanterella
Jump to navigation Jump to search
Errata & Addenda Sheet 5,replacing Pages V/VI,3-1/3-2,4-10, 4-12,4-13 & 4-14 to LOCA Analysis Rept for Dresden Units 2 & 3 & Quad Cities 1 & 2 Nuclear Power Stations
ML17194A063
Person / Time
Site: Dresden, Quad Cities  
Issue date: 05/31/1981
From:
GENERAL ELECTRIC CO.
To:
Shared Package
ML17194A064 List:
References
NEDO-24146A-ERR, NEDO-24146A-ERR-05, NEDO-24146A-ERR-5, NUDOCS 8108070126
Download: ML17194A063 (2)


Text

A tla.c.4 14.te" f I NUCL.fA,,_ ENERGY IUSINESS G"0U' *GENERAL ELECT,.IC CO~ANY SAN JOSE. CAL.IFO.-NIA 9512fl GENERAL. ELECTRIC APPLICABLE TO:

'UIL.ICATtON NO NED0-24146A T. I. l. NO* 79NED273 TtTL.f LOCA ANALYSIS REPORT FOR DRESDEN UNITS 2, 3 AND QUAD CITIES 1,2 NUCLEAR POWER STATION ISSUE OATE April 1979 REFERENCES ITEM (5£CTtO,.,., PACE PARACRAP"1, L..IN[)

1.

Page v/vi Replace with Page 3-1/3-2 Replace with Page 4-10 Replace with IRRATA Ancl ADDENDA SHEET NO DATE May 1981 NOTE: CorrKt all copin of rN applicable publication as ip<<ifi<<J t.low.

INSTRUCTIONS CCOARECTtONS AND ADD*TtONS) new page v/vi.

new pages 3-1 and 3-2.

new page 4-10.

Page 4-12 Replace with new page 4-12.

Page 4-13 Add new page 4-13.

Page 4-14 Add new page 4-14.

'AGE 1 of 1

NED0-24146A Table 4G MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT:

Dresden 2,3/Quad Cities 1,2 FUEL TYPE:

8DRB265L Average Planar Exposure MAPLHGR PCT Oxidation (MWd/t)

(kW/ft)

(oF)

Fraction 200 11.6 2189 0.035 1,000 11.6 2188 0.034 5,000 11.8 2198 0.034 10,000 11.9 2196 0.033 15,000 11.9 2198 0.034 20,000 11 *.7 2195

o. 034*

25,000 11.3 2154 0.030 30,000

10. 7 2075' 0.023 35,000

. 10.2 2002 0.018 l

40,000 9.6 1913 0.013 Table 4H MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT:

Quad Cities 1 FUEL TYPE:

Barrier LTA Average Planar Exposure MAPLHGR PCT Oxidation (MWd/t)

(kW/ft)

(oF)

Fraction 200 11.6 2171 0.032 i,000 11.6 2178 0.033 5,000 12.0 2198 0.034 10,000 12.1 2195 0.033 15,000 12.0 2200 0.033 20,000

11. 7 2187 0.032 25,000 11.0 2115 0.056 30,000 10.5 2029 0.042 4-10