ML17192A695

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-15, Axial (Longitudinal) Oriented Cracking in Piping. No Written Response Required
ML17192A695
Person / Time
Site: Dresden, Quad Cities, Zion  Constellation icon.png
Issue date: 04/21/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
References
NUDOCS 8005210324
Download: ML17192A695 (1)


Text

l CENTRAL FlLES APR 21 1980 Docket Nos. 50-10,~ 50-249, 50-254, 50-265, 50-295, 50-304, Commonwealth Edison Company ATTN:

Mr. Cordell Reed Vice President Post Office Box 767 Chicago, IL 60690 Gentlemen:

This Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the infor-mation for possible applicability to their facilities.

No specific action or response is requested ft this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Enclosure:

Information Notice No. 80-15 cc w/encl:

Mr. D.. L. Peoples, Director of Nuclear Licensing Mr. B. B. Stephenson, Station Superintendent Mr. N. Kalivianakis, Station Superintendent Mr. N. Wandke, Station Superintendent Central Files RIII Fior;i_~jp 4/21/80 Sincerely, James G. Keppler Director Director, NRR/DPM Director, NRR/DOR PDR Local PDR r

'NSIC TIC

~

Mr. Dean Hansell, Office of Assistant Attorney General Kl;~ler