Text
,.* ~*r. Olivero.' Kingsley, Pre!ent Nuclear Generation Group Commonwealth Edison Company Executive Towers West Ill May 18, 1999 *.
1400 Opus Pl~ce. Suite 500 Downers Grove, IL 60515
SUBJECT:
JET PUMP RISER WELD FLAW EVALUATION FOR. DRESDEN NUCLEAR POWER STATION, UNIT 2 (TAC NO. MA1672)
Dear Mr:
Kingsley:
- By letter dated April 11, 1998, Commonwealth Edison Company (ComEd, the licensee).
submitted, for NRC review, the results of the in-vessel visual inspection (IVV!) of the Dresden, Unit 2, jet pumps. This IVVI was conducted by Com Ed during the units 151h refueling outage, D2R15, in accordance with the guidelines of the BWR Vessel Internals.Project Jet Pump Assembly Inspection and Flaw Evaluation Guidelines (BWRVIP-41). The inspection identified an indication in the heat affected zone of the thermal sleeve to riser elbow weld RS-1 of jet pump riser (JPR) 15/16. ComEd's submittal, associated flaw evaluation, and assessment of the impact on operation with the detected flaw was intended to demonstrate that Dresden, Unit 2, could be operated without repair for two fuel cycles. By two letters dated July 10, 1998, and a letter dated November 2, 1998, Com Ed provided additional information.
The staff has complet_ed its review of these submittals and concludes that continued operation of Dresden, Unit 2, without repair of the identified flaw at weld RS-1 of JPR 15/16 is acceptable for two fuel cycles, The staff al.so c;:oncludes that Com Ed's proposal to reexamine the flaw according to the guidelines and schedule of BWRVIP-41. is acceptable. The staffs safety evaluation is enclosed.
This completes our actions with 'respect to TAC No. MA 1672.
- i*
I*
J *,;
~I 1
Sincerely:
.. }*
,'. *-* * *,"\\*,* *.
- )'* dY,; ~; na'l'.,s i~ned 'by "."
- . / *.. *
- Lawren*<::e w., Rossba-ch, Project Manager, Section 2 r-'---::=-=-==-=-=~-:--::-----"--* _, -* __:_-'--'-_..:.:...::.*;;*-.""':.* -.-~.-"*:...:*'..:::;_-:__* ~*-= ;:' Proje,ct.bi.rectorate.111:
- 9905260039 990518
- Divis. ion: of Licensin_ g Proiect-Management PDR ADOCK 05000237 1
J a
- _ Offic;e of Nuclear Reactor*Reg.ulation.
-. ------- -~----* -
- -----.,~*~l--=,1-""
~:.J
'. )
~:.
.:*_* ~ -=--
Docket No.. *sa-*
- *237* - * -* * * *i:.. " ~
. -*....i*
?'-
"L- - -,~!.'J-. ~ ~
EnClosure: Safety*Evaluation *,:
. \\
... ~,:
). '
'*'I.
J
,<"! /
- ~
I cc w/encl: See next page Distribution:
- J. Wermiel
- w. Bateman..
. ~~G'.61i~
M. Ring, Riii PUBLIC C-.;Moore*-
PDlll-2 r/f c* Rossbach J. Zwolinski/S. Black OGG, 015B18 C.Thomas/A. Mendiola ACRS, T2E26 DOCUMENT NAME: G:\\PD3*2\\L TRA 1672.wpd OFFICE PM:PD32 NAME LROSSBAC DATE 04/ 26 /99
- ~.' c:::, '"'11-1 !"flFFICIAL RECORD COPY
~vJ.,-
- 0. Kingsley Commonwealth Edison Company cc:
Commonwealth Edison Company Site Vice President - Dresden 6500 N. Dresden Road Morris, Illinois 60450-9765 Commonwealth Edison Company Dresden Station Manager 6500 N. Dresden Road Morris, Illinois 60450-9765 U.S. Nucle~r Regulatory Commission Dresden Resident Inspectors Office 6500 N. Dresden Road Morris, Illinois 60450-9766
. Regional Administrator *
- U.S. NRC, Region Ill 801 Warrenville Road Lisle, Illinois. 60532-4351 Illinois Department of Nuclear Safety..
Office of Nuclear Facility Safety 1035. Outer Park Drive Springfield, Illinois 62704.
Chairman Grundy County Board Administration Building 1320 Union Street
- Morris, Illinois 60450 Document Control Desk-Licensing Commonwealth Edison Company 1400 Opus Place, Suite 400 Downers Grove, Illinois 60515 Commonwealth Edison Company
.Reg.Assurance Manager-Dresden 6500 N. Dresden Road Morris, Illinois 60450-9765 Mr. David Helwig Senior Vice President Commonwealth Edison Company Executive Towers West Ill 1400 Opus Place, Suite 900 Downers Grove, *111inois 60515 Dresden Nuclear Power St~tion Units 2 and 3 Mr. Gene H. Stanley
. PWR Vice President Commonwealth Edison Company
- Executive Towe rs West Ill 1400 Opus Place, Suite 900 Downers Grove, Illinois 60515 Mr. Christopher Crane
- BWR Vice President..
Commonwealth Edison Company Executive Towe rs West 111 1400 Opus Place, Suite 900 Downers Grove, Illinois 60515 Mr. R. M. Krich Vice President - Regulatory Services Commonwealth Edison Company Executive Towers West Ill.
1400 Opus Place, Suite 500.
Downers Grove, Illinois 60515 Ms. Pamela B. Stroebel Senior Vice President and General *counsel Commonwealth Edison Company
- P.O. Box 767 Chicago,. Illinois 60690-0767
._