March 13, 1997 Ms. Irene Johnson~ Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

RESPONSE TO OCTOBER 9, 1996, REQUEST FOR INFORMATiON PURSUANT TO 10 CFR 50.54(f) REGARDING ~l)EQUACY AND AVAJLABILITY OF DESl§N BASES INFORMATION (TAC NOS. Wt]-5'69, M9].570, M9,7562, M97563, M97,,-5"86, M975.87, M97604, M97605, M97632,. M97633, M97662 AND M97663)

~/

Dear Ms. Johnson:

We have received 'your February '6, '"1997, respons~7 fotfA~)lont1~~1dwood_,

Dresden, LaSalle, Quad Cities and Zion to our October. 9, 1996 1, r~~quest for information pursuant to 10 CFR 50.54(f) regarql>Ufg_i~d£rquijt1§.i't~tJOa*vailability of design bases information.

No additional information is needed at this time.

The. NRC staff is currently evaluating yo4r responses.

Should it be determined that additional information is needed to complete the evaluations, I will notify you.

If you have any questions, pl~ase cont.'act me at (301) 415-1395.,

,. Sincerely,

{~ ' **,, : ;. t '.. :.,*. *

~*-*

I..

J

~ *i

__ *.* ' ~

... ORI.GINAL SIGNED BY:

~'

. **Robert A. Cap'ra.:*Project D'i rector

  • Project,Directorat~ 111-2
  • Divisipn"of Reactof Projects - Jll/IV Office of Nuclear R~actor Regulation I

Docke.t Nos. STN 50-A-54,.STN. 50*..,455*~

STN 50-4.5'6, STN 50-457*~ 50~2-37;;***

50-24~. 50-~73, 50~374, 50~254~

50-2.6'5' 50-295' 50-304.. -

~"'*. '..

cc:

See next page

  • DISTRIBUTION:

tnotket *r.tli:!:: **

...._.... "~*T -

.. : \\; J>UBllC-/

  • J. Roe, JWR G. Dick R. Assa C. Shiraki P. H"iland, Riii R. Capra :.

J. Stang D. Skay OGC 015Bl8

'i E. Adensam EGAl

c. Moore (6)

D.. Lynch

  • L. Rossbach ACRS, T2E26 S. Bailey PDill-2 r/f (6)

R. Lanksbury, Riii

  • R. Pulsifer K. Thomas M. Dapas, Riii

. l>,

  • DOCUMENT NAME:

ALPLANTS\\10CFR54F.DBA in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy

. *NAME.

SBAI LEY RCAPRA DATE. '.

03/l3/97 03//J /97

-~9.-7()4:(1.0194 970313.*

\\ l

~~ICIAL RECORD COPY I

. -~DR ADOCK_ 0500~5~!... J...

,I'

~.. _.......

~ -

1P&

/

March 13, 1997 Ms. Irene Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers ~est III

. 1400 Opus Place, Suite 500 Downers Grove, IL 60515

SUBJECT:

RESPONSE TO OCTOBER 9,- 1996, REQUEST FOR INFORMATION PURSUANT TO 10 CFR 50.54(f) REGARDING ADEQUACY AND AVAILABILITY OF DESIGN BASES INFORMATION (TAC NOS. M97569, M97570, M97562, M97563, M97586, M97587, M97604, M97605, M97632, M97633, M97662 AND M97663)

Dear Ms. Johnson:

We have received your Fe_bruary* 6,

  • 1997, respon*ses for Byro*n, Braidwoo~,
  • Dresden,. LaSalle, Quad Cities and Zion to our October 9, 1996, request for i~formation pursuant to 10 CFR 50.54(f) regarding adequaty and availability of design bases information.

No additional information is needed at this time.

The NRC staff is currenily evaluating your responses.

Should it be determined that additional information is needed to complete the evaluations, I will notify** you.

If you have any questions, please contact me at (301) 415-1395.

Docket Nos. STN.50-454, STN 50-455, STN 50~456~ STN* 50-457, 50-237, 50-249, 50-373~ 50-314, 50-254, 50~265, 50-295, 50-304 cc:

See next page DISTRIBUTION:

J. Roe, JWR G. Dick

  • R. Assa Docket File R.. Capra J. Stang D. Skay C~ Shiraki

. OGC 015Bl8 P. Hiland, RIII E. Adensam EGAl Sincerely, ORIGINAL SIGNED BY:

Robert A.

C~pra, Project Director Project Directorate 111-2 Division of Reactor Projects - *111;1v Office of Nuclear Reactor Regulation

-PUBLIC C. Moore (6)

D. Lynch L. Rossbach ACRS, T2E26 S. Bailey POI 11-2 r /f ( 6)

R. Lanksbury, Riii R. Pulsifer K. Thomas M. Dapas, Riii

  • DOCUMENT NAME:

ALPLANTS\\10CFR54F.DBA in the box: *"C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy PM:PDIIl-2 D:PDill-2 C.

NAME SBAILEYR RCAPRA DATE 03/13/97 03//J /97 OFFICIAL RECORD COPY

UNITED STATES NUCLEAR REGULATORY COMMISSION WASH!NGTON, D.C. 20555--0001 March 13; 1997 Ms.* Ireni Johnson, Acting Manager Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West II.I 1400 Opus Place, Suite 500 Downers Grove, IL 60515

  • suBJECT:

RESPONSE TOOCTOBER 9, 1996, REQUEST FOR INFORMATION PURSUANT TO 10 CFR 50.54(f)" REGARDING ADEQUACY AND AVAILABILITY OF DESIGN BASES INFORMATION (TAC NOS. M97569, M97570, M97562, M97563, *M97586; M97587, M97604, M97605, M97632, M97633, M97662 AND M97663)

Dear Ms. Johnson:

We have r.eceived your February 6, 1997, responses for Byron, Braidwood, Dresden, LaSalle, Quad Cities and Zion to our October 9, 1996, request for info~mation pursuant to 10 CFR 50.54(f) regarding adequacy and availability of design bases information~ No additional information* is needed at this time.

The. NRC staff is currently evaluating your responses.. Should it be determined that ~dditional information is needed to complete the e~aluations, I will notify you:

If* you hav~ any questions, please contact me. at (301) 415~13~5.

Sincerely,

~,,_/a'{~

~ocket Nos. STN 50-454~ STN 50~455, STN 50-456, STN' 50-457, 50-237, 50-249, 50-373, 50~374, 50-254, 50-265, 50-295, 50-304 cc: See next page Robert A. Capra, Project Oirector Project Directorate 111-t DiVision of Reactor Project~ - Ill/IV Office of Nuclear Reactor Regulation

\\,

I. Johnson cc:

Michael I. Mi 11 er, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 Regional Administrator, Region III U.S. Nuclear Regulatory Co11111ission 801 Warrenville Road

Illinois Department of Nuclear Safety Office uf Nuclear Facility S~fety 1035 Outer Park Drive Springfield, Illinois 62704 Document Control Desk-Licensing Commonwealth Edison Company 1400 Opus Place, Suite 400 powners Grove, Illinois

~0515 Mr. William P. Poirier,*Diredor Westinghouse Electric Corporation E~ergy Systems Business Unit Post Office Box 355~ Bay 236 West Pittsburgh, Pennsylvania 15230. *

.Joseph Gallo*

Gallo & Ross 1250 Eye St., N.W.

  • Suite 302° *

. Washington, DC 20005 Howard A.

L~arner, Environmental law and Policy Center of the Midwest 203 North LaSalle Street Suite 1390

Chicago, Ill~nois 60601 U.S. Nuclear Regulatory Commission Byron.Resident Inspectors Office 4448 North German Church Road Byron, Illinois 61010-9750 Ms. Lorraine Creek Rt. 1, Box 182 Manteno, Ill_inois 60950 Commonwealth Edison Company Chairman, Ogle County Board Post Office Box 357 bregon~ Illinois 61061
  • Mrs. Phillip B. Johnson
  • 1907 Stratford Lane Roikford, Illinois 61107 George L. Edgar Morgan, Lewis and Bochius 1800 M Street~ N.W.

Washington, DC

  • 20036 Attorney Gene~al 500 South Second Street Springfield, *Illinois 62701*

EIS Review Coordinator u:s. Environmental Protection Agency 77 W. Jackson Blvd.

Chicago, Illinois.. 60604-3590 Commonwealth Edison Company Byron Sta.ti on Manager 4450 North German Church Road Byron, 11 l i noi s 61010 Kenneth Graesser, Site ~ice Pr~sident Byron Station Commonwealth Edison Station 4450 N. German.Church Road Byron, Illinois 61010 U.S. Nuclear Regulatory Conunission

. Braidwood Resident Inspectors Office R~r~l Route #1,. Box 79 Braceville,* Illinois 6.0407 Mr. Ron Stephens Illinois Emergericy Services and Disaster Agency 110 East Adams Street Springfield, Illino.is* 62706 Chairman Will County Board of Supervisors Will County Board Courthouse Joliet, Illinois 60434

J_

{~.

't

~...

Conmonwealth Edison Company Braidwood Station Manager Rt. 1, Box 84

~Braceville, Illinois 60407 Ms.* Bridget Little Rorem Appleseed Coordinator 117 North Linden Street

Essex, Illi~ois 60935.

Mr:. H. G. Stan 1 ey.

Sit~ Vice President Braidwood Station *

.. Conmonwea 1th *Edi son C~mpany RR l, Box 84.

Bracemille, )L 60407

  • Site Vice President Dresden Nuclear Power Station

~500 North Dresden Road Morris, 111.inois. 60450-9765 *

. Station Man~ger

-Dresden Nuclear Power Station 6500 North Dresden Road Morris, 1111 noi s.

  • 6()450-9765 U.S. Nuclear Regulatory *Commission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, 111 i no is
  • 60450-9766
    • Richard J. Singer Manager - Nuclear MidAmerican Energy Company.

907 Walnut Street P~O. Box 657..

Des Moines, Iowa 50303

.*. Brent E. Gale, Esq.

Vice President ~ Law and MidAmerican Energy Company

  • Regulatory Affairs One RiverCenter Place 106 East Seco.nd Street P.O. Box 4350.

Davenport, Iowa 52808 Chairman Rock Island County Board

  • of Supervisors 1504 3rd Avenue Rock Island County Office-Bldg.

Rock Island, Illinois 61201 Chairman Grundy County Board Administration Building 1320 Union Street Morris, 111.inois 60450 Mr.. l. William Pearce Statiori Manager Quad Cities Nuclear Power Station 22110 206th Avenue North.

  • Cordova, Illinoi_s 612'2 U.S. Nuclear Regulatory Comlniss'io*n Qua_d Cities Resident Inspectors Office 22712 206th Avenue North Cordova, Illinois 61242 Phillip P. Steptoe, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603
  • Assistant Attorney General.

100 West Randolph Stree(

Suite 12 Chicago, Illinois 60601 U.S. Nuclear Regulatory Commission. *

.Resident Inspectors Office LaSalle Statfon 2505:-N.. 21st Road

'Marseilles, Illinois 61341-9756 Chairman LaSalle County Board of Supervisors LaSalle County Courthouse Ottawa, Illinois 61350 Chairman 11lfoois Commerce Commission.

Leland Building 527 East Capitol Avenue

)

LaSalle Station Manager LaSalle County Station Rural Route 1 P.O. Box 220 Marseilles, Illinois 61341 Robert Cushing Chief, Public Utilities Division Illinois Attorney General's Office 100 West Randolph Street Chicago, Illinois 60601 Dr. Cecil Lue-Hing Director of Research and Development Metropolitan Sanitary District of Greater Chicago 100 East Erie Street

. Zion, Illinois 60099 U.S. Nuclear Regulatory Commission*

  • Zion. Resident Inspectors Office.

105 Shiloh Blvd.

Zion, Illinois 60099 Station Manager Zion Nuclear. Power Station 101 Shiloh Blvd.