Ack Receipt of 940419 Response to NRC Info Bulletin Issued 940218 Re Vulnerability of ECCS Suction Strainers in BWRs & Containment Pumps in PWRs to Clogging During Some LOCA Situations.Informs Response to Bulletin Adequate
ML17180A984
Person / Time
Site: Dresden, Quad Cities, LaSalle  
Issue date: 10/24/1994
From: Pulsifer R
Office of Nuclear Reactor Regulation
To: Farrar D
COMMONWEALTH EDISON CO.
References
IEB-93-002, IEB-93-2, TAC-M89284, TAC-M89285, TAC-M89293, TAC-M89294, TAC-M89306, TAC-M89307, NUDOCS 9410280010
Download: ML17180A984 (6)


Text

  • ~

'J' OFC NAME DATE COPY Mr. D. L. Farrar DISTRIBUTION..

Docket File NRC & Local PDRs OGC Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West Ill, Suite 500 1400 OPUS Place

. PD I 11-2 r If CMoore WReckley CPatel JZwolinski JRoe RCapra JS tang Downers Grove, IL 60515 EAdensam

SUBJECT:

ACRS ( 10)

BCl ayton, RII I DRESDEN STATION, UNITS 2 AND 3; LASALLE STATION, UNITS 1 AND 2; QUAD CITIES, UNITS 1 AND 2 - RESPONSE TO NRC BULLETIN 93-02, SUPPLEMENT 1, "DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" (TAC NOS. M89284, M89285, M89293, M89294, M89306 AND M89307)

Dear Mr. Farrar:

This letter acknowledges receipt of your response dated April 19, 1994, to NRC Bulletin 93-02, Supplement 1 (Bulletin). The Bulletin was issued February 18, 1994, to all Boiling Water Reactor (BWR) licensees for action and to all Pressurized Water Reactor (PWR) licensees for information.

The purpose of the Bulletin was to inform BWR and PWR licensees about the vulnerability of ECCS suction strainers in BWRs and containment sumps in PWRs to clogging during the recirculation phase of a loss-of-coolant accident (LOCA), to request that BWR licensees take the appropriate actions to ensure reliability of the ECCS in view of the information discussed in this Bulletin Supplement, and to require that BWR licensees report to the NRC on the requested actions taken.

Your response adequately addressed the actions you have taken to assure the operability of ECCS recirculation. Please retain any records of your actions in response to this Bulletin, as subsequent inspection activities may be conducted in regard to this issue.

Should you have any questions, please contact me at (301) 504-3016 or the lead Project Manager for this. issue, M

.. David Lynch, at (301) 504-30~3.

9410280010 941024 i

PDR ADOCK 05000237 !

Q PDR i -~-

.. ~

Docket Nos~ 50*-237 ;-*50-*249*,- *50-:-254_,

50-26,5*,- 50-373 and 50-374 cc:

see next page

  • See revious concurrence Sincerely, Qf\\ginal Signed By:

.Robert M. Pulsifer, Project Manager Project Ditectorate 111-2 Division of Reactor Projects - Ill/IV Office of Nuclear Reactor Regulation LA: PDIII-2 PM:PDIII-2 PM:PDIII-2 PM: POii l-2 D: POI 11-2 CMOORE*

RPULSIFE JSTANG*

WRECKLEY*

RCAPRA tz~

08/31/94 08 31 94 10/20/94 10 20/94 YES NO YES NO YES/NO YES NO 94 YES NO DOCUMENT NAME:

G:\\CMRCJR\\QUAD\\QC89306.LTR 2 c 0 0 8 5 OFFICIAL RECORD COPY NR'1: Al~ c~rnirER COPY 1 f

.(

OFC NAME DATE COPY Mr. D. L. Farrar DISTRIBUTION Manager, Nuclear Regulatory Services*

  • Docket File NRC & Local PDRs OGC Commonwealth Edison Company PDill-2 r/f JZwolinski JRoe Executive Towers West III, Suite 500 CMoore RCapra 1400 OPUS Place WReckley JStang Downers Grove, IL 60515 CPatel
  • EAdensam ACRS ( 1.0)

BCl ayton, RI II

SUBJECT:

DRESDEN STATION, UNITS 2 AND 3; LASALLE. S*TATION, UNITS 1 AND 2;

~UAD CITIES, UNITS 1 AND 2*- RESPONSE TO NRC BULLETIN 93-02, SUPPLEMENT 1, "DEBRIS PLUGGING OF EMER~ENCY CORE'COOLING SUCTION STRAINERS" (TAC NOS. M89284, M89285, M89293, M89294, M89306 AND M89307)

Dear Mr. Farrar:

This letter acknowledges receipt of your response dated Apri1 19, 1994, to NRC Bulletin 93-02, Supplement 1 (Bulletin). The. Bulletin was issued February 18, 1994, to all Boiling Water-Rea'ctor (BWR) *licensees for action and to all Pressurized Water Reactor (PWR) licensees for information. The purpose of the Bulletin was to inforfu BWR and PWR licensees about the vulnerability of ECCS suction strainers jr:l"*BWRs and containment sumps in PWRs to clogging during the.recirculation phase of a loss-of-coolant accident (LOCA), to request that BWR licensees take the appropriate actions to ensure reliability of the ECCS in view of the information discussed in this Bulletin Supplement, and to require that BWR licensees report to the NRC on the requested actions taken.

Your response adequately addressed the actions you have taken to assure the operability of ECCS recirculation.

We will await your report on completion of the requested actions.

Please retain sny records of your actions in response to this Bulletin, as subsequent inspection activities may

.be conducted in regard to this issue.

Should you have any questions, please contact me at (301) 504-3025 or the lead Project Manager for this issue, M. David Lynch~ at (301) 504-3023.

Docket Nos. 50-237, 50-249, 50-254, 50-265, 50-373 and 50-374 cc:

see next page Sincerely, Chandu P. Patel, Project Manager Project Directorate 111-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regul~tion PM: POii 1-2 D: POii 1-2 RCAPRA I

/94

  • I /94 YES/NO YES/NO

. ~*

OFC NAME DATE COPY October 24, 1994

  • Mr. O. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place DISTRIBUTION Docket File POI 11-2 r/f CMoore WReckley CPatel ACRS{IO}

NRC & Local PDRs OGC JZwolinski JRoe RCapra JStang Downers Grove, IL 60515 EAdensam

SUBJECT:

BCl ayton, Rll I DRESDEN STATION, UNITS 2 AND 3; LASALLE STATION, UNITS 1 AND 2; QUAD CITIES, UNITS 1 AND 2 - RESPONSE TO NRC BULLETIN 93-02, SUPPLEMENT 1, "DEBRIS PLUGGING OF EMERGENCY CORE COOLING SUCTION STRAINERS" (TAC NOS. M89284, M89285, M89293, M89294, M89306 AND M89307}

Dear Mr. Farrar:

This letter acknowledges receipt of your response dated April 19, 1994, to NRC Bulletin 93-02, Supplement 1 {Bulletin}.

The Bulletin was issued February 18, 1994, to all Boiling Water Reactor {BWR} licensees for action and to all Pressurized Water Reactor {PWR} licensees for information.

The purpose of the Bulletin was to inform BWR and PWR licensees about the vulnerability of ECCS suction strainers in BWRs and containment sumps in PWRs to clogging during the recirculation phase of a loss-of-coolant accident {LOCA), to request that BWR licensees take the appropriate actions to ensure reliability of the ECCS in view of the information discussed in this Bulletin Supplement, and to require that BWR licensees report to the NRC on the requested actions taken.

Your response adequately addressed the actions you have taken to assure the operability of ECCS recirculation. Please retain any records of your actions in response to this Bulletin, as subsequent inspection activities may be conducted in regard to this issue.

Should you have any questions, please contact me at (301} 504-3016 or the lead Project Manager.for this issue, M. David Lynch, at (301} 504-3023.

Sincerely, Original Signed By:

Robert M. Pulsifer, Project Manager Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-237, 50-249, 50-254, 50-265, 50-373 and 50-374 cc: see next page s

  • ee prev1ous concurrence LA: POI 11-2 PM: POii I-2 PM: POii I-2 PM: POI II-2 CMOORE*

RPULS I FE~_;{;(' JSTANG*

WRECKLEY*

08/31/94 08/31/94 10/20/94 10/20/94 YES/NO YES/NO YES/NO YES/NO DOCUMENT NAME:

G:\\CMRCJR\\QUAD\\QC89306.LTR OFFICIAL RECORD COPY D: PDII I-2 RCAPRA !._c----

JO ;Z9/94 rY"ES)o I /94 YES/NO

Mr. D. L. Farrar Commonwealth Edison Company cc:

Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. G. Spedl Plant Manager Dresden Nuclear Power Station 6500 North Dresden Road Morris, Illinois 60450-9765 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, Illinois 60450-9766 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Chairman Grundy County Board Administration Building 1320 Union Street Morris, Illinois 60450 Dresden Nuclear Power Station Unit Nos. 2 and 3

~.

(

Mr. D. L. Farrar Commonwealth Edison Company cc:

Phillip P. Steptoe, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60603 Assistant Attorney General 100 West Randolph Street Suite 12 Chicago, Illinois 60601 Senior Resident Inspector LaSalle County Station U. S. Nuclear Regulatory Commission 2605 N. 21st Road Marseilles, Illinois 61341-9756 Chairman LaSalle County Board of Supervisors LaSalle County Courthouse Ottawa, Illinois 61350 Attorney General 500 South 2nd Street Springfield, Illinois 62701 Chairman Illinois Commerce Commission Leland Building 527 East Capitol Avenue Springfield, Illinois 62706 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 LaSalle Station Manager LaSalle County Station Rural Route 1 P.O. Box 220 Marseilles, Illinois 61341 LaSalle County Station Unit Nos. 1 and 2 Robert Cushing Chief, Public Utilities Division Illinois Attorney General's Office 100 West Randolph Street Chicago, Illinois 60601 Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690

1

\\

Mr. D. L. Farrar Commonwealth Edison Company cc:

Mr. Stephen E. Shelton Vice President Iowa-Illinois Gas and Electric Company P. 0. Box 4350 Davenport, Iowa 52808 Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. Guy Campbell Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Quad Cities Resident Inspectors Office U. S. Nuclear Regulatory Commission 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Quad Cities Nuclear Power Station Unit Nos. 1 and 2

\\