ML17180A824

From kanterella
Jump to navigation Jump to search
Summary of 940526 Meeting W/Util in Rockville,Md Re Core Shroud Cracking Specific to Dresden & Quad Cities & to Generically Discuss Rv Internals Cracking in BWR Plants.List of Attendees Encl
ML17180A824
Person / Time
Site: Dresden, Quad Cities  
Issue date: 07/07/1994
From: Stang J
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17180A825 List:
References
NUDOCS 9407150087
Download: ML17180A824 (6)


Text

..

).

July 7, 1994

  • Docket Nos. 50-237, 50-249 and 50-254, 50-265 A;r (l

"~

I OFC NAME DATE COPY LICENSEE:

Commonwealth Edison Company (CECo)

FACILITIES:

Dresden, Units 2 and 3, and Quad Cities, Units 1 and 2

SUBJECT:

MEETING

SUMMARY

OF MAY 26, 1994 On May 26, 1994, in a public meeting, the NRC staff met with representatives from CECo and the Boiling Water Reactor Owners Group (BWROG) to discuss the core shroud cracking specific to Dresden and Quad Cities, and generically discuss reactor vessel internals cracking in boiling water reactor (BWR) plants. A list of attendees is enclosed (Enclosure 1).

The meeting was divided into morning and afternoon sessions.

The morning session was transcribed. is a copy of the transcript.

The morning session was a high level discussion between senior NRC and CECo and industry management.

During the session, CECo discussed the core shroud inspection at the Dresden and Quad Cities Stations and the extent of cracking found during the inspection.

In addition, the licensee discussed the aspects of safe operation with degraded core shroud and repair options to the shroud. is a copy of CECo's handout.

The BWROG addressed on a generic basis, cracking of core shroud and other BWR reactor vessel internals. is a copy of the BWROG's handout.

The afternoon session was a specific discussion on the result of the Dresden and Quad Cities core shroud inspection and the licensee's options on restarting without repairing the shroud and the possible repair option.

The NRC staff identified a concern that asymmetric depressurization could create lateral loading on the core shroud resulting in displacement, rotation, or local deformation of the shell that could open a pre-existing crack.

CECo indicated in the meeting that an evaluation concerning this would be provided to the staff for review.

Enclosures:

1. Attendance List
2.

Transcript

3.

CECO Handout

4.

BWROG Handout cc w/enclosures:

See next page Original signed by:

John F. Stang, Project Manager Project Directorate III-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation D:PDIII-2 RCAPRA f-v-/

1 I 7 /94 I

/94 YES/NO I

/94 YES/NO 9407150087 940707 PDR ADOCK 05000237

\\

T PDR

DISTRIBUTION (all enclosures)

,-- Docket Fll e..

~- NRC &- -Local-PDRs PDIII-r/f BCl ayton, RII I CPatel JStang MEETING

SUMMARY

OF MAY 26, 1994 DISTRIBUTION (Enclosure 1 only)

WRussel/FMiraglia RZimmerman JRoe JZwolinski CMoore OGC EJordan ACRS(lO)

BMcCabe, EDO DMcDonald PRush VMcCree RCapra TCollins RHermann EHackett WBeecher MMcBrearty KBattige BKoo MMitchell KWichman DBrinkman JStrosnider BS heron AThadani JTaylor RJones DKirkpatrick PMil ano CPoslusny TGreene OS keen ACubbage MRubin MMayfield AHiser MRazzague

)

Mr. D. L. Farrar**

C.ommonwea 1th Edi son Company cc:

Michael I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. G. Spedl Plant Manager Dresden Nuclear Power Station 6500 North Dresden Road Morris, Illinois 60450-9765 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station 6500 North Dresden Road Morris, Illinois 60450-9766 Chairman Board of Supervisors of*

Grundy County Grundy County Courthouse Morris, Illinois 60450 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Mr. D. L. Farrar Manager, Nuclear Regulatory Services Commonwealth Edison Company Executive Towers West III, Suite 500 1400 OPUS Place Downers Grove, Illinois 60515 Dresden Nuclear Power Station Unit Nos. l and 3

I

)

Mr. D. L. Farrar Commonwealth Edison Company cc:.

Mr. Stephen E~ *Shelton Vice President Iowa-Illinois Gas and Electric Company P. O. Box 4350 Davenport, Iowa 52808 Michael-I. Miller, Esquire Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. Guy Camp be 11 Station Manager Quad Cities Nuclear Power Station 22710 206th Avenue North Cordova, Illinois 61242 Quad Cities Resident Inspectors Office U. S. Nuclear Regulatory Commission 22712 206th Avenue North Cordova, Illinois 61242 Chairman Rock Island County Board of Supervisors 1504 3rd Avenue Rock Island County Office Bldg.

Rock Island, Illinois 61201 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Regional Administrator U. S. NRC, Region III 801 Warrenville Road Lisle, Illinois 60532-4351 Quad Cities Nuclear Power Station*

Unit Nos. 1 and 2

Carl Terry Robert A. Pinelli Tony Jaschke Robin Dyle Les England Hwang Choe Gerald Gordon Sam Ranganath Alan Baker A. J. Gi annuzzi Jack Lance David Rogowski Kevin Ramsden D. G. McDonald Phillip Rush V. Mccree Jim Dyer Timothy Collins Brian McCabe Chandu Patel Robert Hermann Ed Hackett Robert Capra Luis Reyes William Beecher Michael McBrearty John Hoffman Richard Smith Thien Do Jack Purkis Ken Battige Bill Koo Matthew Mitchell Keith Wichman Donald Brinkman Herb Massin Irene Johnson Peter Piet Jerry Whitman Tom Spry LIST OF ATTENDEES FOR MEETING ON MAY 26, 1994*

Affiliation Niagara Mohawk BWROG (GPUN)

GE Inspection Svcs.

BWORG/SNC

. BWROG/Entergy GE Nuclear Energy GE Nuclear Energy GE Nuclear Energy GE Nuclear Energy Structural Integ. Assoc.

EPRI CECo/Dresden CECo/NFS NRC/NRR/DRP/PDI-1 NRC/NRR/DE/EMCB NRC/OEDO NRR/PDIII-2 NRR/SRXB NRC/OEDO NRR/PDIII-2 NRC/NRR NRC/NRR/EMCB NRC/NRR NRG NRG NRC/NRR Yankee Atomic SciTech (Tech Sup. to CECo)

CECo/NETS CP&L NRC/NRR/DE/EMCB NRC/NRR/DE/EMCB NRC/NRR/DE/EMCB NRR/EMCB NRR/PDI-1 CECo/SECM Dresden CECo/Nuc. Lie. Director CECo/Licensing Administrator CECo/SEC Dresden CECo/NETS ENCLOSURE 1

~

- t -

Name Affiliation Joe Wi 11 i ams CECo/Dresden Mike Lyster CECo VP.Dresden John Hosmen CECo VP Nuc Eng Bob Walsh CECo/,QC Robert Moravec CECo/QC Jack Strosnider NRR/EMCB Brian Sheron NRR/DE Ashok Thadani NRC/NRR Jim Taylor EDO/NRC W. T. Russell NRC/NRR

,/

Robert Jones NRC/NRR/DSSA John A. Zwolinski NRC/NRR/ADR3 John Stang NRR/PDI II-2 Roy Anderson CP&L Tony Harris CP&L Julien Abramovici GPUN Don Kirkpatrick NRC/NRR/DORS Patrick Milano NRR/NRR/PDII-1 Noman Cole MPR Associates William Campbell CP&L L. Vaughn Wagoner CP&L John ~angdon CP&L Hector Barbeto Bechtel Serch Licensing Kathleen Hart McGraw-Hill Chet Poslusny NRR/PDI-2 Tom Greene NRR/DORS/OEAB David Skeen NRR/DORS/OEAB Amy Cubbage NRR/DSSA/SRXB Mark Rubin NRR/DSSA/SRXB Drew Holland GPU Nuclear Bob Borsum BWNT James J. Raleigh Southern Technical Services Michael Mayfield RES/DE/MEB All en Hiser RES/DE/MEB Muhammad Razzagne SRXB/NRR/NRC Mario Robles ABB-CE Ed Siegel ABB-CE