UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 Docket Nos. 50-237 and 50-249 Mr. Thomas J. Kovach Ncclear Licensing Manager Commonwealth Edison Company - Suite 300 OPUS West III 1400 Opus Place Downers Grove, Illinois 60515

Dear Mr. Kovach:

January 28, 1992

SUBJECT:

INSERVICE INSPE<:TION PROGRAM UPDATE, DRESDEN UNITS 2 AND 3 (TAC NOS. M80350 AND M80351)

By letter dated April 25, 1991, Commonwealth Edison Company (CECo) requested approval to use the 1989 Edition of Section XI of the ASME Code and the Articles for Repair, Pressure Testing, and Replacement of the 1989 Addenda for the inservice inspection program update for Dresden Nuclear Power Station, Units 2 and 3.

Based on the requirements of 10 CFR 50.55a(g)(4)(ii), the code edition and addenda to which the updated program should comply is the 1986 Edition.

However, 10 CFR 50.55a(g)(4)(iv) states, in part, that inservice examinations of components and system pressure tests muy meet the requirements set forth in subsequent editions and addenda of Section XI that are incorporated in paragraph (b) of 10 CFR 50.55a subject to limitations and modifications listed in paragraph (b) and subject to Co1TU11ission approval.

CEC0 1s request is based partially on information supplied by the staff regarding the status of proposed rulemaking for 10 CFR 50.55(a) in which the 1989 Edition of Section XI has been incorporated and the fact that the third ten-year inservice inspection interval for Dresden Nuclear Station, Units 2 and 3, begins March 2, 1992.

It should be noted that the proposed rulemaking does not incorporate the 1989 Addenda of Section XI in paragraph (b) of 10 CFR 50.55(a).

Based on the review of CEC0 1s request, the staff concluded that approval should be granted to use the 1989 Edit~on of Section XI of the ASME Code for the updated inservice ir.spection program for Dresden Nuclear Station, Units 2 and

3. Cur conclusion was based on the fact that the subject edition has been reviewed by the staff and has been accepted for incorporation in paragraph (b) of 10 CFR 50.55a in the proposed rulemaking.

In addition, the staff agrees with CEC0 1s comment that the 1989 Edition of Section XI clarifies some of the requirements contained in the 1986 Edition. Its use for the updated ten-year inservice inspection program for Dresden Nuclear Station, Units 2 and 3, would, therefore, benefit both the licensee and the NRC by eliminating unclear requirements.

The review of the Addenda of Section XI has not been completed by the staff f'l/~4;~.

and is not part of the proposed rulemaking.

For this reason, the staff can neither approve nor recommend its use in the updated program.*

(

92~205021*4'~ ~§855~37

'\\,.

~

f.Q \\

fllfttIDlfil IX:~m Ft: ~IC!iU'W'IC~ ~fM!>>V

\\

PDR ADOCK.v,. -. PDR

/

µ r Bwtfd~ rtrn.. tb \\'Wl;U~ m f!:n tlDUlr t1

',_ - f> __.

\\\\o

~ *'

Thomas If you have any questions regarding the staff resolution of this request, please contact Mr. Byron L. Siegel at (301) 504-3019.

cc:

See next page DISTRIBUTJON Docket Fi le JZwo l inski OGC ACRS(lO).

NRC & Local PDRs RBarrett PDIII-2 gray GJohnson Sincerely, Or19'naJ Signed ~yt Richard J. Barrett, Director Project Directorate III-2 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation PDIII-2 r/f BBoger CMoore BSiegel BC 1 ayton, RII I CY Cheng

~Tl-2.f)pM/PDIII-2

~~\\

Vt-~s; ege l

\\ I~ /92

~-. I/ 1.() /92 EMCB (l~/P~

CYCheng / RBarrett oGrA.ltdi

.AjU~tl1.i

. ' 12"" /92 I I *J/92 I /11/92 DOCUMENT NAME:

INSERVICE INSPECTION UPDATE

Mr. Thomas J. Kovach Commonwealth Edison Company cc:

Michael I. Miller, Esq.

Sidley and Austin One First National Plaza Chicago, Illinois 60690 Mr. J. Eenigenburg Plant Superintendent Dresden Nuclear Power Station Rural Route #1 Morris, Illinois 60450 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station Rural Route #1 Morris, Illinois 60450 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Regional Administrator Nuclear Regulatory Commission, Region III 799 Roosevelt Road, Bldg. #4 Glen Ellyn, Illinois 60137 Illinois Department of Nuclear Safety Office of Nuclear Facility Safety 1035 Outer Park Drive Springfield, Illinois 62704 Robert Neumann Office of Public Counsel State of Illinois Center 100 W. Randolph Suite 11~300 thicago, Illinois 60601 Dresden Nuclear Power Station Unit Nos. 2 and 3

°

t*.

J Thomas ** If you have any questions regarding the staff resolution of this request, please contact Mr. _Byron L Siegel at (301) 504-3019.

cc:

See next page DISTRIBUTION Docket File JZwo l inski OGC ACRS(lO)

NRC & Local PDRs RBarrett

. PDII I-2 gray GJohnson Sincerely, Orislnai Signed ayr Richard J. Barrett, Director Project Directorate III-2 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation PDIII-2 r/f BBoger

  • CMoore BSiegel BClayton, RIII CY Cheng WTI-2

~~~

.i)rM/PDIII-2

~~Siegel EMCB CNJVP~

OG~

~~

\\ /'f'/92 r 11°192 CYCheng J RBarrett r I ij/92 1 Ir' /92 DOCUMENT NAME:

INSERVICE INSPECTION UPDATE